Imaging guidelines for nuclear cardiology procedures
References (57)
- et al.
Head-to-head comparison of exercise stress testing, pharmacologic stress echocardiography, and perfusion tomography as first-time examination for chest pain in patients without history of coronary artery disease
J Nucl Cardiol
(1998) - et al.
Reliability of enhanced gated SPECT in assessing wall motion of severely hypoperfused myocardinm: echocardiographic validation
J Nucl Cardiol
(1998) - et al.
Comparison of technetium-99m tetrofosmin and thallium-201 single-photon emission computed tomographic imaging for detection of myocardial perfusion defects in patients with coronary artery disease
J Am Coll Cardiol
(1998) - et al.
Risk assessment using single-photon emission computed tomographic technetium-99m sestamibi imaging
J Am Coll Cardiol
(1998) - et al.
Outcome of medical versus invasive treatment strategies for non-high-risk ischemic heart disease
J Nucl Cardiol
(1998) - et al.
Value of gating of technetium-99m sestamibi single-photon emission computed tomographic imaging
J Am Coll Cardiol
(1997) - et al.
Validation of a new counts-based gated single photon emission computed tomography method for quantifying left ventricular systolic function: comparison with equilibrium radionuclide angiography
J Nucl Cardiol
(1997) - et al.
Prognostic value of stress myocardial perfusion single photon emission computered tomography imaging in patients with left bundle branch block
J Nucl Cardiol
(1997) - et al.
Independent and incremental prognostic value of exercise single-photon emission computed tomographic (SPECT) thallium imaging in coronary artery disease
J Am Coll Cardiol
(1993) - et al.
Clinical application of radionuclide angiography
J Nucl Cardiol
(1995)
Rest and treadmill exercise first-pass radionuclide ventriculography: validation of left ventricular ejection fraction measurements
J Nucl Cardiol
One year prognosis of patients with normal planar and single photon emission computerized tomography technetium-99m-labeled sestamibi exercise imaging
J Nucl Cardiol
Combined exercise radionuclide angiocardiography and single-photon emission computed tomography perfusion studies for assessment of coronary artery disease
Semin Nucl Med
Quantitative aspects of myocardial perfusion imaging
Semin Nucl Med
Computer versus visual analysis of exercise thallilum-201 images: a critical appraisal in 325 patients with chest pain
Am Heart J
Quantitative planar thallium-201 stress scintigraphy: a critical evaluation of the method
Semin Nucl Med
Prognostic indicators from radionuclide angiography in medically treated patients with coronary artery disease
Am J Cardiol
Noninvasive diagnosis of pulmonary arterial hypertension in chronic obstructive pulmonary arterial hypertension in chronic obstructive pulmonary disease: right ventricular ejection fraction at rest
Am J Cardiol
Effect of exercise protocol on the left ventricular response to exercise
Am J Cardiol
Value of left ventricular ejection fraction during exercise in predicting the extent of coronary artery disease
J Am Coll Cardiol
Right ventricular function in aortic and mitral valve disease: relation of gated first-pass radionuclide angiography to clinical and hemodynamic findings
Chest
Assessment of single-vessel coronary artery disease: results of exercise electrocardiography, thallium-201 myocardial perfusion imaging and radionuclide angiography
J Am Coll Cardiol
Multiple gated cardiac blood pool imaging for left ventricular ejection fraction: validation of the technique and assessment of variability
Am J Cardiol
Gating provides improved accuracy for differentiating artifacts from true lesions in equivocal fixed defects on technetium-99m tetrofosmin perfusion SPECT
J Nucl Cardiol
Incremental prognostic value of myocardial perfusion single photon emission computed tomography for the prediction of cardiac death, differential stratification for risk of cardiac death and myocardial infarction
Circulation
Equilibrium radionuclide angiocardiography
Automatic quantification of ejection fraction from gated myocardial perfusion SPECT
J Nucl Med
An assessment of factors which influence the effectiveness of the modified in vivo technetium-99m-erythrocyte labeling technique in clinical use
J Nucl Med
Cited by (86)
Prevalence of myocardial perfusion scintigraphy derived ischemia in coronary lesions with discordant fractional flow reserve and non-hyperemic pressure ratios
2022, International Journal of CardiologyImaging of myocardial inflammation with somatostatin receptor based PET/CT - A comparison to cardiac MRI
2015, International Journal of CardiologyPrognostic value of late heart rate recovery after treadmill exercise
2012, American Journal of CardiologyCitation Excerpt :A minority of studies used a 2-day technetium-99m sestamibi protocol in patients weighing >350 lb to improve image quality. Images were interpreted using a 20-segment scoring system in which 0 = normal tracer activity and 4 = no tracer activity.13 Total scores for the stress and rest images determined the summed stress score and summed rest score, respectively, the difference of which represents the combined size and severity of stress-induced perfusion defects.
LV segmentation and mechanics in HCM: Twisting the Rubik's cube into perfection!
2012, JACC: Cardiovascular ImagingSurvival by stress modality in patients with a normal myocardial perfusion study
2011, American Journal of CardiologyCitation Excerpt :Images were acquired with a dual-detector γ-camera (ADAC Vertex, ADAC Laboratories, Milpitas, California; or Siemens e.cam, Siemens Medical Systems, Hoffman Estates, Illinois) with 64 projections for 25 seconds each, covering 180° (elliptical orbit with the ADAC Vertex, body-contoured orbit with Siemens e.cam). SPECT images were interpreted using a semiquantitative 20-segment scoring system in which 0 equals normal tracer activity and 4 equals no tracer activity.5 Total score for the image at rest equals the summed rest score (SRS) and similarly for the stress image's summed stress score (SSS).