The application of extracorporeal membrane oxygenation in adults has been increasing, but infections occurring during extracorporeal membrane oxygenation use are rarely described.

Methods

We retrospectively analyzed the prospectively collected data on nosocomial infection surveillance of 334 patients aged 16 years or more undergoing their first extracorporeal membrane oxygenation for more than 48 hours at a university hospital from 1996 to 2007 for respiratory (20.4%) and cardiac (79.6%) support.

Results

During a total of 2559 extracorporeal membrane oxygenation days, 55 episodes of infections occurred in 45 patients (13.5%), including 38 bloodstream (14.85 per 1000 extracorporeal membrane oxygenation days), 6 surgical site, 4 respiratory tract, 3 urinary tract, and 4 other infections. Stenotrophomonas maltophilia (16.7%) and Candida species (14.6%) were the predominant blood isolates. In stepwise logistic regression analysis, longer duration of extracorporeal membrane oxygenation use (odds ratio 1.003; 95% confidence interval, 1.001–1.005; P = .004), mechanical complications (odds ratio, 4.849; 95% confidence interval, 1.569–14.991; P = .006), autoimmune disease (odds ratio, 6.997; 95% confidence interval, 1.541–31.766; P = .012), and venovenous mode (odds ratio, 4.473; 95% confidence interval, 1.001–19.977; P = .050) were independently associated with a higher risk for infections during extracorporeal membrane oxygenation use. Overall in-hospital mortality was 68.3%, and its independent risk factors included older age (odds ratio, 1.037; 95% confidence interval, 1.021–1.054; P < .001), neurologic complications (odds ratio, 51.153; 95% confidence interval, 6.773–386.329; P < .001), and vascular complications (odds ratio, 1.922; 95% confidence interval, 1.112–3.320; P < .001), but not infections during extracorporeal membrane oxygenation use.

Conclusions

Bloodstream infection was the most common infection during extracorporeal membrane oxygenation use. Duration of extracorporeal membrane oxygenation, mechanical complications, autoimmune disease, and venovenous mode seemed to be independently associated with infections.

CTSNet classification

25
25.1

Abbreviations and Acronyms

APACHE II
Acute Physiology and Chronic Health Evaluation II
CI
confidence interval
CPR
cardiopulmonary resuscitation
ECMO
extracorporeal membrane oxygenation
IABP
intra-aortic balloon pump
OR
odds ratio
VV
venovenous

Cited by (0)

Disclosures: None.