Clinical research study
From the Society for Clinical Vascular Surgery
Mesenteric artery complications during angioplasty and stent placement for atherosclerotic chronic mesenteric ischemia

Presented at the Thirty-ninth Annual Symposium of the Society for Clinical Vascular Surgery, Orlando, Fla, March 16-19, 2011.
https://doi.org/10.1016/j.jvs.2011.10.122Get rights and content
Under an Elsevier user license
open archive

Objective

The purpose of this study was to describe the incidence, management, and outcomes of mesenteric artery complications (MACs) during angioplasty and stent placement (MAS) for chronic mesenteric ischemia (CMI).

Methods

We retrospectively reviewed the clinical data of 156 patients treated with 173 MAS for CMI (1998-2010). MACs were defined as procedure-related mesenteric artery dissection, stent dislodgement, embolization, thrombosis, or perforation. End points were procedure-related morbidity and death.

Results

There were 113 women and 43 men (mean age, 73 ± 14 years). Eleven patients (7%) developed 14 MACs, including distal mesenteric embolization in six, branch perforation in three, dissection in two, stent dislodgement in two, and stent thrombosis in one. Five patients required adjunctive endovascular procedures, including in two patients each, catheter-directed thrombolysis or aspiration, retrieval of dislodged stents, and placement of additional stents for dissection. Five patients (45%) required conversion to open repair: two required evacuation of mesenteric hematoma, two required mesenteric revascularization, and one required bowel resection. There were four early deaths (2.5%) due to mesenteric embolization or myocardial infarction in two patients each. Patients with MACs had higher rates of mortality (18% vs 1.5%) and morbidity (64% vs 19%; P <.05) and a longer hospital length of stay (6.3 ± 4.2 vs 1.6 ± 1.2 days) than those without MACs. Periprocedural use of antiplatelet therapy was associated with lower risk of distal embolization or vessel thrombosis (odds ratio, 0.2; 95% confidence interval, 0.06-0.90). Patients treated by a large-profile system had a trend toward more MACs (odds ratio, 1.8; 95% confidence interval, 0.7-26.5; P = .07).

Conclusions

MACs occurred in 7% of patients who underwent MAS for CMI and resulted in higher mortality, morbidity, and longer hospital length of stay. Use of antiplatelet therapy reduced the risk of distal embolization or vessel thrombosis. There was a trend toward more MACs in patients who underwent interventions performed with a large-profile system.

Cited by (0)

Competition of interest: Dr Oderich has a consultant agreement for Cook Medical Inc.

The editors and reviewers of this article have no relevant financial relationships to disclose per the JVS policy that requires reviewers to decline review of any manuscript for which they may have a competition of interest.