Abstract
Purpose: To demonstrate the use of Nd:YAG laser in clearing the anterior surface of posterior chamber intraocular lenses.
Method: Six cases are presented with the following conditions: haemorrhage, inflammatory deposits, a fibrinous papillary membrane, capsulorhexis shrinkage.
Results: Nd:YAG laser was successful in managing each of these cases.
Conclusion: With careful use Nd:YAG laser clearance of the anterior surface of a posterior chamber intraocular lens can be carried out successfully without damaging the lens.
Similar content being viewed by others
Article PDF
References
Apple DJ, Mamalis N, Loftfield K, et al. Complications of intraocular lenses: a historical and histopathological review. Surv Ophthalmol 1984; 29: 1–54.
Hagan JC, Menapace R, Radax U . Clinical syndrome of endocapsular hematoma: presentation of a collected series and review of the literature. J Cataract Refract Surg 1996; 22: 379–84.
Jaffe GJ, Abrams GW, Williams GA, Han DP . Tissue plasminogen activator for postvitrectomy fibrin formation. Ophthalmology 1990; 97: 184–9.
Amon A, Menapace R . In vivo documentation of cellular reactions on lens surfaces for assessing the biocompatibility of different intraocular implants. Eye 1994; 8: 649–56.
Lesser GR, Osher RH, Whipple D, et al. Treatment of anterior chamber fibrin following cataract surgery with tissue plasminogen activator. J Cataract Refract Surg 1993; 19: 301–5.
Folk JC, Hershey JM, Rivers MB . Lack of effectiveness of tissue plasminogen activator 20 or more days after vitrectomy. Arch Ophthalmol 1991; 109: 614.
Gandham SB, Brown RH, Katz JL, Lynch MG . Neodymium:YAG membranectomy for pupillary membranes on posterior chamber intraocular lenses. Ophthalmology 1995; 102: 1846–52.
Chen HS, Steinmann WC, Spaeth GL . The effect of chronic miotic therapy on the results of posterior chamber intraocular lens implantation and trabeculectomy in patients with glaucoma. Ophthalmic Surg 989; 20: 784–9.
Choun-Ki J, Ah-Jeong S, Jae-Ho K . Capsular opening contraction after continuous curvilinear capsulorhexis and intraocular lens implantation. J Cataract Refract Surg 1996; 22: 585–90.
Young DA, Orlin SE . Capsulorhexis contracture in phacoemulsification surgery. Ophthalmic Surg 1994; 25: 477–8.
Nishi O, Nishi K . Intraocular lens encapsulation by shrinkage of the capsulorhexis opening. J Cataract Refract Surg 1993; 19: 544–5.
Toldos JJM, Roig AA, Benabent EC . Total anterior capsule closure after silicone intraocular lens implantation. J Cataract Refract Surg 1996; 22: 269–71.
Aron-Rosa DS, Aron JJ, Cohn HC . Use of a pulsed picosecond Nd:YAG laser in 6664 cases. Am Intraocular Implant Soc J 1984; 10: 35–40.