Abstract
Purpose Various materials are used in orbital blowout fracture repair. We describe a series of patients with orbital blowout fractures that were repaired using porous polyethylene (Medpor) sheets.
Methods A non-comparative interventional case series is described of 30 blowout fractures of 30 patients aged 7-60 years (median 29 years) who underwent orbital blowout fracture repair with Medpor sheets. The mean follow-up was 19.1 months (minimum 5 months). The indication for surgery in 6 cases was non-resolving diplopia. The remaining 24 cases had surgery for enophthalmos. Ten cases underwent primary or secondary hydroxyapatite orbital implantation at the same time as orbital floor blowout fracture repair. Data were collected on postoperative motility and diplopia, enophthalmos, cosmesis, complications and re-operations.
Results In no case was diplopia worsened by blowout fracture repair. Where surgery was performed for the correction of enophthalmos, late surgery did not compromise the surgical results. There were no intraoperative complications. The one major complication was a case of recurrent implant infections leading to implant removal. There were 3 minor postoperative complications: 2 cases of postoperative infraorbital anaesthesia and one case of a palpable titanium screw. Re-operations were performed for pre-existent diplopia, lid laxity, socket abnormalities and mid-facial deformities. None of these arose from the blowout fracture repair.
Conclusions The study suggests that in orbital blowout fracture repair Medpor implants are safe and effective with few complications. Late surgery for enophthalmos is technically more difficult but is not associated with poorer functional or cosmetic results.
Similar content being viewed by others
Article PDF
References
Purdy EP . Oculoplastic and orbital applications of porous high-density polyethylene implants. Curr Opin Ophthalmol 1997;8:57–63.
Ousterhout DK, Stelnicki EJ . Plastic surgery's plastics. Clin Plast Surg 1996;23:183–90.
Berghaus A . Porous polyethylene in reconstructive head and neck surgery. Arch Otolaryngol 1985;111:154–60.
Wellisz T . Clinical experience with the Medpor porous polyethylene implant. Aesthetic Plast Surg 1993;17:339–44.
Romano JJ, Iliff NT, Manson PN . Use of Medpor porous polyethylene implants in 140 patients with facial fractures. J Craniofac Surg 1993;4:142–7.
Berghaus A, Mulch G, Handrock M . Porous polyethylene and proplast: their behaviour in a bony implant bed. Arch Otorhinolaryngol 1984;240:115–23.
Spector M, Flemming WR, Sauer BW . Early tissue infiltrate in porous polyethylene implants into bone: a scanning electron microscope study. J Biomed Mater Res 1975;9:537–42.
Rathbun JE . Orbital fractures. In: Stephenson CM, editor. Ophthalmic plastic, reconstructive, and orbital surgery. Boston: Butterworth-Heinemann, 1997:417–36.
Nguyen PN, Sullivan P . Advances in the management of orbital fractures. Clin Plastic Surg 1992;19:87–98.
Browning CW . Alloplast materials in orbital repair. Am J Ophthalmol 1967;63:955–62.
Sewell SR, Pernoud FG, Pernoud MJ . Late reaction to silicone following reconstruction of an orbital floor fracture. J Oral Maxillofac Sug 1986;44:821–5.
Doughterty WR, Wellisz T . The natural history of alloplastic implants in orbital floor reconstruction: an animal model. J Craniofac Surg 1994;5:26–32.
Ono I, Gunji H, Suda K, Kaneko F, Yago K . Orbital reconstruction with hydroxyapatite ceramic implants. Scand J Plast Reconstr Surg Hand Surg 1994;28:193–8.
Allen CS, Shore JW, Westfall CT . Simplified method of sizing implants for orbital fracture repair. Am J Ophthalmol 1995;120:260–1.
Haug RH, Kimberly D, Bradrick JP . A comparison of microscrew and suture fixation for porous high-density polyethylene orbital floor implants. J Oral Maxillofac Surg 1993;51:1217–20.
Choi JC, Fleming JC, Aitken PAS, Shore JW . Porous polyethylene channel implants: a modified porous polyethylene sheet implant designed for repairs of large and complex wall fractures. Ophthalmic Plast Reconstr Surg 1999;15:56–66.
Polley JW, Ringler SL . The use of Teflon in orbital floor reconstruction following blunt facial trauma: a 20-year experience. Plast Reconstr Surg 1987;79:39–43.
Jordan DR, St Onge P, Anderson RL, Patrinely JR, Nerad JA . Complications associated with alloplastic implants used in orbital fracture repair. Ophthalmology 1992;99:1600–8.
Rubin PA, Bilyk JR, Shore JW . Orbital reconstruction using porous polyethylene sheets. Ophthalmology 1994;101:1697–708.
Kreidler JF, Koch H . Endoscopic findings of maxillary sinus after middle face fractures. J Maxillofac Surg 1975;3:10–4.
Westfall CT, Shore JW, Nunery WR, Hawes MJ, Yaremchuk MJ . Operative complications of the transconjunctival inferior fornix approach. Ophthalmology 1991;98:1525–8.
Jordan DR, Allen LH, White J, Harvey J, Pashby R, Esmaeli B . Intervention within days for some orbital floor fractures: the white-eyed blowout. Ophthalmic Plast Reconstr Surg 1998;14:379–90.
Author information
Authors and Affiliations
Corresponding author
Additional information
Presented in part as a poster at the Royal College of Ophthalmologists Congress, Harrogate, May 2000
Rights and permissions
About this article
Cite this article
Ng, S., Madill, S., Inkster, C. et al. Medpor porous polyethylene implants in orbital blowout fracture repair. Eye 15, 578–582 (2001). https://doi.org/10.1038/eye.2001.188
Received:
Accepted:
Issue Date:
DOI: https://doi.org/10.1038/eye.2001.188
Keywords
This article is cited by
-
Delayed onset porous polyethylene implant-related inflammation after orbital blowout fracture repair: four case reports
BMC Ophthalmology (2016)
-
Comparison of Efficacy of Mandible and Iliac Bone as Autogenous Bone Graft for Orbital Floor Reconstruction
Journal of Maxillofacial and Oral Surgery (2015)
-
Retrospective analysis of orbital floor fractures—complications, outcome, and review of literature
Clinical Oral Investigations (2011)
-
Long-term follow-up of blowout fractures of the orbital floor reconstructed with a polyglactin 910/PDS implant
European Journal of Trauma and Emergency Surgery (2011)
-
Retrospective survey of 150 surgically treated orbital floor fractures in a trauma referral centre
European Journal of Plastic Surgery (2009)