Semin intervent Radiol 2009; 26(1): 010-016
DOI: 10.1055/s-0029-1208378
© Thieme Medical Publishers

Imaging Surveillance following Endovascular Aneurysm Repair

Anand Shah1 , S. William Stavropoulos1
  • 1Division of Interventional Radiology, Department of Radiology, Hospital of the University of Pennsylvania, Philadelphia, Pennsylvania
Further Information

Publication History

Publication Date:
16 March 2009 (online)

ABSTRACT

Endoleaks are unique complications of endovascular aneurysm repair (EVAR) that necessitate lifelong imaging surveillance for the patient. Several imaging modalities may be used to monitor the patient for endoleaks and other complications related to the stent graft. At present, computed tomographic angiography remains the gold standard for the detection of endoleaks. Other modalities that can be used to detect endoleaks include magnetic resonance, ultrasonography, nuclear medicine techniques, and pressure monitoring. In addition, follow-up imaging with digital subtraction angiography is important for endoleak classification and to guide decisions regarding therapy. In this article, we review the classification of endoleaks and discuss the different imaging strategies available for post-EVAR surveillance.

REFERENCES

  • 1 Parodi J C, Palmaz J C, Barone H D. Transfemoral intraluminal graft implantation for abdominal aortic aneurysms.  Ann Vasc Surg. 1991;  5 491-499
  • 2 Greenhalgh R M, Brown L C, Kwong G P, Powell J T, Thompson S G. Comparison of endovascular aneurysm repair with open repair in patients with abdominal aortic aneurysm (EVAR trial 1), 30-day operative mortality results: randomised controlled trial.  Lancet. 2004;  364 843-848
  • 3 Schermerhorn M L, O'Malley A J, Jhaveri A et al.. Endovascular vs. open repair of abdominal aortic aneurysms in the Medicare population.  N Engl J Med. 2008;  358 464-474
  • 4 Veith F J, Baum R A, Ohki T et al.. Nature and significance of endoleaks and endotension: summary of opinions expressed at an international conference.  J Vasc Surg. 2002;  35 1029-1035
  • 5 Stavropoulos S W, Baum R A. Imaging modalities for the detection and management of endoleaks.  Semin Vasc Surg. 2004;  17 154-160
  • 6 Schlosser F J, Gusberg R J, Dardik A et al.. Aneurysm rupture after EVAR: can the ultimate failure be predicted?.  Eur J Vasc Endovasc Surg. 2009;  37 15-22
  • 7 Baum R A, Stavropoulos S W, Fairman R M, Carpenter J P. Endoleaks after endovascular repair of abdominal aortic aneurysms.  J Vasc Interv Radiol. 2003;  14 1111-1117
  • 8 Fearn S, Lawrence-Brown M MD, Semmens J B, Hartley D. Follow-up after endovascular aortic aneurysm repair: the plain radiograph has an essential role in surveillance.  J Endovasc Ther. 2003;  10 894-901
  • 9 Hodgson R, McWilliams R G, Simpson A et al.. Migration versus apparent migration: importance of errors due to positioning variation in plain radiographic follow-up of aortic stent-grafts.  J Endovasc Ther. 2003;  10 902-910
  • 10 Murphy M, Hodgson R, Harris P L et al.. Plain radiographic surveillance of abdominal aortic stent-grafts: the Liverpool/Perth protocol.  J Endovasc Ther. 2003;  10 911-912
  • 11 Manning B J, O'Neill S M, Haider S N et al.. Duplex ultrasound in aneurysm surveillance following endovascular aneurysm repair: a comparison with computed tomography aortography.  J Vasc Surg. 2008;  , September 30 (Epub ahead of print)
  • 12 Bendick P J, Bove P G, Long G W et al.. Efficacy of ultrasound scan contrast agents in the noninvasive follow-up of aortic stent grafts.  J Vasc Surg. 2003;  37 381-385
  • 13 Carrafiello G, Lagana D, Recaldini C et al.. Comparison of contrast-enhanced ultrasound and computed tomography in classifying endoleaks after endovascular treatment of abdominal aorta aneurysms: preliminary experience.  Cardiovasc Intervent Radiol. 2006;  29 969-974
  • 14 AbuRahma A F, Welch C A, Mullins B B, Dyer B. Computed tomography versus color duplex ultrasound for surveillance of abdominal aortic stent-grafts.  J Endovasc Ther. 2005;  12 568-573
  • 15 Ashoke R, Brown L C, Rodway A et al.. Color duplex ultrasonography is insensitive for the detection of endoleak after aortic endografting: a systematic review.  J Endovasc Ther. 2005;  12 297-305
  • 16 Golzarian J, Murgo S, Dussaussois L et al.. Evaluation of abdominal aortic aneurysm after endoluminal treatment: comparison of color Doppler sonography with biphasic helical CT.  AJR Am J Roentgenol. 2002;  178 623-628
  • 17 d'Audiffret A, Desgranges P, Kobeiter D H, Becquemin J P. Follow-up evaluation of endoluminally treated abdominal aortic aneurysms with duplex ultrasonography: validation with computed tomography.  J Vasc Surg. 2001;  33 42-49
  • 18 Elkouri S, Panneton J M, Andrews J C et al.. Computed tomography and ultrasound in follow-up of patients after endovascular repair of abdominal aortic aneurysm.  Ann Vasc Surg. 2004;  18 271-279
  • 19 Napoli V, Bargellini I, Sardella S G et al.. Abdominal aortic aneurysm: contrast-enhanced US for missed endoleaks after endoluminal repair.  Radiology. 2004;  233 217-225
  • 20 Insko E K, Kulzer L M, Fairman R M, Carpenter J P, Stavropoulos S W. MR imaging for the detection of endoleaks in recipients of abdominal aortic stent-grafts with low magnetic susceptibility.  Acad Radiol. 2003;  10 509-513
  • 21 van der Laan M J, Bartels L W, Viergever M A, Blankensteijn J D. Computed tomography versus magnetic resonance imaging of endoleaks after EVAR.  Eur J Vasc Endovasc Surg. 2006;  32 361-365
  • 22 Cejna M, Loewe C, Schoder M et al.. MR angiography vs CT angiography in the follow-up of nitinol stent grafts in endoluminally treated aortic aneurysms.  Eur Radiol. 2002;  12 2443-2450
  • 23 Ayuso J R, de Caralt T M, Pages M et al.. MRA is useful as a follow-up technique after endovascular repair of aortic aneurysms with nitinol endoprostheses.  J Magn Reson Imaging. 2004;  20 803-810
  • 24 Lookstein R A, Goldman J, Pukin L, Marin M L. Time-resolved magnetic resonance angiography as a noninvasive method to characterize endoleaks: initial results compared with conventional angiography.  J Vasc Surg. 2004;  39 27-33
  • 25 Cohen E I, Weinreb D, Siegelbaum R et al.. Time-resolved MR angiography for the classification of endoleaks after endovascular aneurysm repair.  J Magn Reson Imaging. 2008;  27 500-503
  • 26 Armerding M D, Rubin G D, Beaulieu C F et al.. Aortic aneurysmal disease: assessment of stent-graft treatment—CT versus conventional angiography.  Radiology. 2000;  215 138-146
  • 27 Rozenblit A M, Patlas M, Rosenbaum A T et al.. Detection of endoleaks after endovascular repair of abdominal aortic aneurysm: value of unenhanced and delayed helical CT acquisitions.  Radiology. 2003;  227 426-433
  • 28 Iezzi R, Cotroneo A R, Filippone A et al.. Multidetector CT in abdominal aortic aneurysm treated with endovascular repair: are unenhanced and delayed phase enhanced images effective for endoleak detection?.  Radiology. 2006;  241 915-921
  • 29 Iezzi R, Cotroneo A R, Filippone A et al.. Multidetector-row computed tomography angiography in abdominal aortic aneurysm treated with endovascular repair: evaluation of optimal timing of delayed phase imaging for the detection of low-flow endoleaks.  J Comput Assist Tomogr. 2008;  32 609-615
  • 30 Stavropoulos S W, Marin H, Fairman R M et al.. Recurrent endoleak detection and measurement of aneurysm size with CTA after coil embolization of endoleaks.  J Vasc Interv Radiol. 2005;  16 1313-1317
  • 31 Chandarana H, Godoy M CB, Vlahos I et al.. Abdominal aorta: evaluation with dual-source dual-energy multidetector CT after endovascular repair of aneurysms—initial observations.  Radiology. 2008;  249 692-700
  • 32 Stolzmann P, Frauenfelder T, Pfammatter T et al.. Endoleaks after endovascular abdominal aortic aneurysm repair: detection with dual-energy dual-source CT.  Radiology. 2008;  249 682-691
  • 33 Macari M, Chandarana H, Schmidt B et al.. Abdominal aortic aneurysm: can the arterial phase at CT evaluation after endovascular repair be eliminated to reduce radiation dose?.  Radiology. 2006;  241 908-914
  • 34 Stavropoulos S W, Clark T WI, Carpenter J P et al.. Use of CT angiography to classify endoleaks after endovascular repair of abdominal aortic aneurysms.  J Vasc Interv Radiol. 2005;  16 663-667
  • 35 Stavropoulos S W, Itkin M, Lakhani P et al.. Detection of endoleaks after endovascular aneurysm repair with use of technetium-99m sulfur colloid and Tc-99m-labeled red blood cell scans.  J Vasc Interv Radiol. 2006;  17 1739-1743
  • 36 Hovsepian D M, Siegel B A, Kimbiris G et al.. Tc-99m sulfur colloid scintigraphy for detecting perigraft flow following endovascular aortic aneurysm repair: a feasibility study.  Cardiovasc Intervent Radiol. 1999;  22 447-451
  • 37 Springer F, Gunther R W, Schmitz-Rode T. Aneurysm Sac pressure measurement with minimally invasive implantable pressure sensors: an alternative to current surveillance regimes after EVAR?.  Cardiovasc Intervent Radiol. 2008;  31 460-467
  • 38 Springer F, Schlierf R, Pfeffer J G et al.. Detecting endoleaks after endovascular AAA repair with a minimally invasive, implantable, telemetric pressure sensor: an in vitro study.  Eur Radiol. 2007;  17 2589-2597
  • 39 Harris P L, Vallabhaneni S R, Desgranges P et al.. Incidence and risk factors of late rupture, conversion, and death after endovascular repair of infrarenal aortic aneurysms: the EUROSTAR experience.  J Vasc Surg. 2000;  32 739-749
  • 40 Hinchliffe R J, Ivancev K. Endovascular aneurysm repair: current and future status.  Cardiovasc Intervent Radiol. 2008;  31 451-459

S. William StavropoulosM.D. 

Associate Professor of Radiology, Division of Interventional Radiology, Department of Radiology

Hospital of the University of Pennsylvania, 3400 Spruce Street, 1 Silverstein, Philadelphia, PA 19104

Email: stav@uphs.upenn.edu

    >