Endoscopy 2014; 46(S 01): E541-E542
DOI: 10.1055/s-0034-1377633
Cases and Techniques Library (CTL)
© Georg Thieme Verlag KG Stuttgart · New York

Double-balloon enteroscope-assisted enteral stent placement for malignant afferent-loop obstruction after Roux-en-Y reconstruction

Takashi Sasaki
1   Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
,
Hiroyuki Isayama
1   Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
,
Hirofumi Kogure
1   Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
,
Atsuo Yamada
1   Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
,
Taku Aoki
2   Hepato-Biliary-Pancreatic Surgery Division, Department of Surgery, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
,
Norihiro Kokudo
2   Hepato-Biliary-Pancreatic Surgery Division, Department of Surgery, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
,
Kazuhiko Koike
1   Department of Gastroenterology, Graduate School of Medicine, The University of Tokyo, Tokyo, Japan
› Author Affiliations
Further Information

Publication History

Publication Date:
19 November 2014 (online)

A 64-year old man was admitted to our hospital because of acute cholangitis. He had previously undergone pancreatoduodenectomy with Roux-en-Y reconstruction for a pancreatic neuroendocrine carcinoma ([Fig. 1]). A computed tomography (CT) scan revealed afferent-loop obstruction due to lymph node metastases ([Fig. 2]).

Zoom Image
Fig. 1 Schematic of the Roux-en-Y reconstruction.
Zoom Image
Fig. 2 Computed tomography (CT) scan showing malignant afferent-loop obstruction.

A double-balloon enteroscope (DBE; EN-450T5/W; Fujifilm Medical Systems) was inserted near the stenosis of the afferent loop, from where it was just possible to pass the enteroscope through the stenosis ([Video 1]). A clip was placed on either side of the stenosis and contrast medium was also injected to identify the stenosis ([Fig. 3 a]). The overtube was moved back from the stenosis to take a distance for stent delivery and was fixed by the balloon. The enteroscope was then removed leaving the guidewire (0.035-inch Jagwire; Boston Scientific, Tokyo, Japan) in place.


Quality:
A double-balloon enteroscope was inserted close to the afferent-loop obstruction. After the stenosis had been identified endoscopically and fluoroscopically, the enteroscope was carefully removed. The stent delivery system was advanced over the guidewire via the overtube and an enteral stent was delivered under fluoroscopic guidance.

Zoom Image
Fig. 3 Fluoroscopic views showing: a malignant afferent-loop obstruction; b the stent delivery system being introduced via the overtube; c the enteral stent in place.

A Niti-S D pyloric/duodenal stent (22 mm × 6 cm; TaeWoong Medical, Seoul, South Korea) was advanced along the guidewire via the overtube ([Fig. 3 b]). The stent delivery system was passed easily through the end of the overtube. The self-expanding metal stent (SEMS) was delivered under fluoroscopic guidance using the contrast medium and the clips as landmarks ([Fig. 3 c]). After the SEMS had been placed, the enteroscope was inserted again via the overtube to confirm that the SEMS was correctly positioned. The patient’s cholangitis was successfully controlled by placement of the SEMS.

SEMS placement for malignant small-bowel obstruction is challenging because it is sometimes difficult to approach the stenosis, and it is not possible to pass a stent delivery system through the working channel of an enteroscope. A few reports of the use of an endoscopic approach exist, but none of these have included malignant afferent-loop obstruction following Roux-en-Y reconstruction [1] [2] [3] [4]. SEMS placement via percutaneous transhepatic biliary drainage has been reported, but it carries a risk of biliary leakage [5]. In this case, it was possible to securely deliver the SEMS to the stenosis because the overtube was firmly fixed by the balloon. Therefore, DBE-assisted SEMS placement is a useful procedure in the management of malignant afferent-loop obstruction.

Endoscopy_UCTN_Code_TTT_1AP_2AD

 
  • References

  • 1 Ross AS, Semrad C, Waxman I et al. Enteral stent placement by double balloon enteroscopy for palliation of malignant small bowel obstruction. Gastrointest Endosc 2006; 64: 835-837
  • 2 Lennon AM, Chandrasekhara V, Shin EJ et al. Spiral-enteroscopy-assisted enteral stent placement for palliation of malignant small-bowel obstruction (with video). Gastrointest Endosc 2010; 71: 422-425
  • 3 Lee H, Park JC, Shin SK et al. Preliminary study of enteroscopy-guided, self-expandable metal stent placement for malignant small bowel obstruction. J Gastroenterol Hepatol 2012; 27: 1181-1186
  • 4 Popa D, Ramesh J, Peter S et al. Small bowel stent-in-stent placement for malignant small bowel obstruction using a balloon-assisted overtube technique. Clin Endosc 2014; 47: 108-111
  • 5 Laasch HU. Obstructive jaundice after bilioenteric anastomosis: transhepatic and direct percutaneous enteral stent insertion for afferent loop occlusion. Gut Liver 2010; 4 (Suppl. 01) 589-595