Endosc Int Open 2016; 04(03): E360-E370
DOI: 10.1055/s-0042-101023
Original article
© Georg Thieme Verlag KG Stuttgart · New York

Mapping international practice patterns in EUS-guided tissue sampling: outcome of a global survey

Priscilla A. van Riet
Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center Rotterdam, Rotterdam, The Netherlands
,
Djuna L. Cahen
Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center Rotterdam, Rotterdam, The Netherlands
,
Jan-Werner Poley
Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center Rotterdam, Rotterdam, The Netherlands
,
Marco J. Bruno
Department of Gastroenterology and Hepatology, Erasmus MC University Medical Center Rotterdam, Rotterdam, The Netherlands
› Author Affiliations
Further Information

Publication History

submitted 23 October 2015

accepted after revision 05 January 2016

Publication Date:
18 March 2016 (online)

Background and study aims: Although Endoscopic Ultrasound (EUS)-guided tissue sampling is widely used, the optimal sampling strategy remains subject of debate. We evaluated practice patterns within the international endosonographic community.

Patients and methods: An online questionnaire was sent to 400 endosonographers from the United States, Europe, and Asia.

Results: A total of 186 (47 %) endosonographers participated: United States 54 (29 %), Europe 85 (46 %), and Asia 47 (25 %). European (75 %) and Asian (84 %) respondents routinely check coagulation status, whereas US respondents only check on indication (64 %, P = 0.007). While propofol sedation is standard in the United States (83 %), conscious sedation is still widely used in Europe (52 %) and Asia (84 %, P < 0.001). Overall, the 22-gauge needle is most commonly used (52 %). For fine-needle aspiration (FNA) of solid pancreatic lesions, 22-gauge (45 %) and 25-gauge (49 %) needles are used equally. For fine-needle biopsy (FNB) of solid masses, the 25-gauge device is less favored than the 22-gauge FNA device (49 % versus 21 %). The 19-gauge needle is generally used for FNB of submucosal masses (62 %). Rapid on-site pathological evaluation (ROSE) is utilized more often by US (98 %) than by European and Asian respondents (51 %, P < 0.001). Cytolyt (52 %), formalin (15 %) and alcohol (15 %) are used for FNA specimen preservation in the United States and Europe, while saline (27 %) and alcohol (38 %) are widely used in Asia (P < 0.001).

Conclusions: EUS-guided tissue sampling practices vary substantially within the international endosonographic community and differ considerably from recommendations expressed in guidelines. Because the clinical relevance of these variations is largely unknown, the outcome of this survey suggests a need for further studies.

 
  • References

  • 1 Huang JY, Chang KJ. Improvements and innovations in endoscopic ultrasound guided fine needle aspiration. J Hepatobiliary Pancreat Sci 2015; DOI: 10.1002/jhbp.232.
  • 2 Iglesias-Garcia J, Dominguez-Munoz JE, Abdulkader I et al. Influence of on-site cytopathology evaluation on the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration (EUS-FNA) of solid pancreatic masses. Am J Gastroenterol 2011; 106: 1705-1710 DOI: 10.1038/ajg.2011.119. ajg2011119 [pii]
  • 3 Pellise Urquiza M, Fernandez-Esparrach G, Sole M et al. Endoscopic ultrasound-guided fine needle aspiration: predictive factors of accurate diagnosis and cost-minimization analysis of on-site pathologist. Gastroenterol Hepatol 2007; 30: 319-324 13107565 [pii]
  • 4 Erickson RA, Sayage-Rabie L, Beissner RS. Factors predicting the number of EUS-guided fine-needle passes for diagnosis of pancreatic malignancies. Gastrointest Endosc 2000; 51: 184-190 S0016510700797264 [pii]
  • 5 Iwashita T, Nakai Y, Samarasena JB et al. High single-pass diagnostic yield of a new 25-gauge core biopsy needle for EUS-guided FNA biopsy in solid pancreatic lesions. Gastrointest Endosc 2013; 77: 909-915 DOI: 10.1016/j.gie.2013.01.001. S0016-5107(13)00002-3 [pii]
  • 6 Larghi A, Iglesias-Garcia J, Poley JW et al. Feasibility and yield of a novel 22-gauge histology EUS needle in patients with pancreatic masses: a multicenter prospective cohort study. Surg Endosc 2013; 27: 3733-3738 DOI: 10.1007/s00464-013-2957-9.
  • 7 Bang JY, Hebert-Magee S, Trevino J et al. Randomized trial comparing the 22-gauge aspiration and 22-gauge biopsy needles for EUS-guided sampling of solid pancreatic mass lesions. Gastrointest Endosc 2012; 76: 321-327 DOI: 10.1016/j.gie.2012.03.1392. S0016-5107(12)01679-3 [pii]
  • 8 Madhoun MF, Wani SB, Rastogi A et al. The diagnostic accuracy of 22-gauge and 25-gauge needles in endoscopic ultrasound-guided fine needle aspiration of solid pancreatic lesions: a meta-analysis. Endoscopy 2013; 45: 86-92 DOI: 10.1055/s-0032-1325992.
  • 9 Eckardt AJ, Adler A, Gomes EM et al. Endosonographic large-bore biopsy of gastric subepithelial tumors: a prospective multicenter study. Eur J Gastroenterol Hepatol 2012; 24: 1135-1144 DOI: 10.1097/MEG.0b013e328356eae2.
  • 10 Early DS, Acosta RD. Committee ASoP et al. Adverse events associated with EUS and EUS with FNA. Gastrointest Endosc 2013; 77: 839-843 DOI: 10.1016/j.gie.2013.02.018. S0016-5107(13)00176-4 [pii]
  • 11 Dumonceau JM, Polkowski M, Larghi A et al. Indications, results, and clinical impact of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline. Endoscopy 2011; 43: 897-912 DOI: 10.1055/s-0030-1256754.
  • 12 Polkowski M, Larghi A, Weynand B et al. Learning, techniques, and complications of endoscopic ultrasound (EUS)-guided sampling in gastroenterology: European Society of Gastrointestinal Endoscopy (ESGE) Technical Guideline. Endoscopy 2012; 44: 190-206 DOI: 10.1055/s-0031-1291543.
  • 13 Lichtenstein DR, Jagannath S. Standards of Practice Committee of the American Society for Gastrointestinal E et al. Sedation and anesthesia in GI endoscopy. Gastrointest Endosc 2008; 68: 815-826 DOI: 10.1016/j.gie.2008.09.029. S0016-5107(08)02617-5 [pii]
  • 14 Jue TL, Sharaf RN. Committee ASoP et al. Role of EUS for the evaluation of mediastinal adenopathy. Gastrointest Endosc 2011; 74: 239-245 DOI: 10.1016/j.gie.2011.03.1255. S0016-5107(11)01532-X [pii]
  • 15 Khashab MA, Chithadi KV. Committee ASoP et al. Antibiotic prophylaxis for GI endoscopy. Gastrointest Endosc 2015; 81: 81-89 DOI: 10.1016/j.gie.2014.08.008. S0016-5107(14)02077-X [pii]
  • 16 Dietrich CF, Jenssen C. Endoscopic ultrasound-guided sampling in gastroenterology: European society of gastrointestinal endoscopy technical guidelines. Endosc Ultrasound 2013; 2: 117-122 DOI: 10.7178/eus.06.001. EUS-2-117 [pii]
  • 17 Pitman MB, Layfield LJ. Guidelines for pancreaticobiliary cytology from the Papanicolaou Society of Cytopathology: A review. Cancer Cytopathol 2014; 122: 399-411 DOI: 10.1002/cncy.21427.
  • 18 Brugge W, Dewitt J, Klapman JB et al. Techniques for cytologic sampling of pancreatic and bile duct lesions. Diagn Cytopathol 2014; 42: 333-337 DOI: 10.1002/dc.23096.
  • 19 McQuaid KR, Laine L. A systematic review and meta-analysis of randomized, controlled trials of moderate sedation for routine endoscopic procedures. Gastrointest Endosc 2008; 67: 910-923 DOI: 10.1016/j.gie.2007.12.046. S0016-5107(07)03354-8 [pii]
  • 20 Dewitt J, McGreevy K, Sherman S et al. Nurse-administered propofol sedation compared with midazolam and meperidine for EUS: a prospective, randomized trial. Gastrointest Endosc 2008; 68: 499-509 DOI: 10.1016/j.gie.2008.02.092. S0016-5107(08)00372-6 [pii]
  • 21 Ootaki C, Stevens T, Vargo J et al. Does general anesthesia increase the diagnostic yield of endoscopic ultrasound-guided fine needle aspiration of pancreatic masses?. Anesthesiology 2012; 117: 1044-1050 DOI: 10.1097/ALN.0b013e31826e0590.
  • 22 Aisenberg J, Brill JV, Ladabaum U et al. Sedation for gastrointestinal endoscopy: new practices, new economics. Am J Gastroenterol 2005; 100: 996-1000 DOI: 10.1111/j.1572-0241.2005.50034.x. AJG50034 [pii]
  • 23 Anderson MA, Ben-Menachem T. Committee ASoP et al. Management of antithrombotic agents for endoscopic procedures. Gastrointest Endosc 2009; 70: 1060-1070 DOI: 10.1016/j.gie.2009.09.040. S0016-5107(09)02549-8 [pii]
  • 24 Hernandez LV, Klyve D, Regenbogen SE. Malpractice claims for endoscopy. World journal of gastrointestinal endoscopy 2013; 5: 169-173 DOI: 10.4253/wjge.v5.i4.169.
  • 25 Conklin LS, Bernstein C, Bartholomew L et al. Medical malpractice in gastroenterology. Clinical gastroenterology and hepatology : the official clinical practice journal of the American Gastroenterological Association 2008; 6: 677-681 DOI: 10.1016/j.cgh.2008.02.047.
  • 26 Lee SY, Tang SJ, Rockey DC et al. Managing anticoagulation and antiplatelet medications in GI endoscopy: a survey comparing the East and the West. Gastrointest Endosc 2008; 67: 1076-1081 DOI: 10.1016/j.gie.2007.11.037. S0016-5107(07)03115-X [pii]
  • 27 Fujimoto K, Fujishiro M, Kato M et al. Guidelines for gastroenterological endoscopy in patients undergoing antithrombotic treatment. Dig Endosc 2014; 26: 1-14 DOI: 10.1111/den.12183.
  • 28 Lee YN, Moon JH, Kim HK et al. Core biopsy needle versus standard aspiration needle for endoscopic ultrasound-guided sampling of solid pancreatic masses: a randomized parallel-group study. Endoscopy 2014; 46: 1056-1062 DOI: 10.1055/s-0034-1377558.
  • 29 Hucl T, Wee E, Anuradha S et al. Feasibility and efficiency of a new 22G core needle: a prospective comparison study. Endoscopy 2013; 45: 792-798 DOI: 10.1055/s-0033-1344217.
  • 30 Vanbiervliet G, Napoleon B, Saint Paul MC et al. Core needle versus standard needle for endoscopic ultrasound-guided biopsy of solid pancreatic masses: a randomized crossover study. Endoscopy 2014; 46: 1063-1070 DOI: 10.1055/s-0034-1377559.
  • 31 Alatawi A, Beuvon F, Grabar S et al. Comparison of 22G reverse-beveled versus standard needle for endoscopic ultrasound-guided sampling of solid pancreatic lesions. United European Gastroenterol J 2015; 3: 343-352 DOI: 10.1177/2050640615577533. 10.1177_2050640615577533 [pii]
  • 32 Affolter KE, Schmidt RL, Matynia AP et al. Needle size has only a limited effect on outcomes in EUS-guided fine needle aspiration: a systematic review and meta-analysis. Dig Dis Sci 2013; 58: 1026-1034 DOI: 10.1007/s10620-012-2439-2.
  • 33 Iglesias-Garcia J, Larino-Noia J, Abdulkader I et al. Rapid on-site evaluation of endoscopic-ultrasound-guided fine-needle aspiration diagnosis of pancreatic masses. World J Gastroenterol 2014; 20: 9451-9457 DOI: 10.3748/wjg.v20.i28.9451.
  • 34 Faigel DO, Baron TH, Adler DG et al. ASGE guideline: guidelines for credentialing and granting privileges for capsule endoscopy. Gastrointest Endosc 2005; 61: 503-505 S0016510704027816 [pii]
  • 35 Azad JS, Verma D, Kapadia AS et al. Can U.S. GI fellowship programs meet American Society for Gastrointestinal Endoscopy recommendations for training in EUS? A survey of U.S. GI fellowship program directors. Gastrointest Endosc 2006; 64: 235-241 DOI: 10.1016/j.gie.2006.04.041. S0016-5107(06)01911-0 [pii]
  • 36 Wasan SM, Kapadia AS, Adler DG. EUS training and practice patterns among gastroenterologists completing training since 1993. Gastrointest Endosc 2005; 62: 914-920 DOI: 10.1016/j.gie.2005.08.045. S0016-5107(05)02754-9 [pii]