Rofo 2004; 176(8): 1100-1105
DOI: 10.1055/s-2004-813277
Rapid Communication

© Georg Thieme Verlag KG Stuttgart · New York

Two-Dimensional Parallel Acquisition Technique in 3D MR Colonography

Zweidimensionale parallele Bildgebung in der 3D-MR-KolonographieG. Steidle1 , J. Schäfer2 , H. P. Schlemmer2 , C. D. Claussen2 , F. Schick1
  • 1Sektion für Experimentelle Radiologie (Sektionsleiter: Prof. Dr. Dr. F. Schick), Eberhard-Karls-Universität Tübingen
  • 2Abteilung für Radiologische Diagnostik (Ärztlicher Direktor: Prof. Dr. C.D. Claussen), Eberhard-Karls-Universität Tübingen
Further Information

Publication History

Publication Date:
22 June 2004 (online)

Zusammenfassung

Ziel der Studie: Bestimmung des Einflusses von ein (1D)- und zweidimensionaler (2D) paralleler Akquisitionstechnik (PAT) auf das Kontrast-zu-Rausch-(CNR-)Verhältnis und die Bildqualität bei der helllumigen 3D-MR-Kolonographie. Methoden: An einem 1.5-T-Ganzkörper-MRT-System (MAGNETOM AVANTO®, Siemens AG, Erlangen) wurden in-vitro-Messungen an einem Kolon-Phantom mit einer gespoilten 3D-Gradienten-Echo-(3D-GRE-)Sequenz und einer volumeninterpolierten 3D-GRE-(VIBE-)Sequenz für verschiedene Beschleunigungsfaktoren (PAT-Faktoren) und Auflösungen durchgeführt und jeweils das relative CNR bestimmt sowie die Bildqualität beurteilt. Eine helllumige 3D-MR-Kolonographie mit den PAT-Faktoren 2, 3, 4 und 6 wurde an einem 39-jährigen Probanden durchgeführt und die erhaltenen 3D-Datensätze bezüglich der Bildqualität miteinander verglichen. Ergebnisse: Bei den In-vitro-Messungen ergaben sich für die PAT-Faktoren 1, 2, 3, 4 bzw. 6 mittlere, relative CNR-Werte von 1, 0,81, 0,73, 0,52 und 0,4 bei der 3D-GRE-Sequenz und 1, 0,8, 0,65, 0,45 und 0,3 bei der VIBE-Sequenz. Geringe Einfaltungsartefakte waren bei 2D PAT vor allem für die VIBE-Sequenz zu erkennen. Für die helllumige 3D-MR-Kolonographie konnte bei dem untersuchten Probanden mit Erhöhung des PAT-Faktors bis 6 und einer Reduzierung der Akquisitionszeit auf weniger als 10 s eine ausreichende Bildqualität mit deutlich weniger durch Peristaltik und Pulsationen erzeugten Bildartefakten erreicht werden. Diskussion: Die Verwendung von 2D PAT führt selbst für hohe PAT-Faktoren bis 6 zu einem für Diagnosezwecke akzeptablen CNR-Verlust. Für die 3D-MR-Kolonographie können mit 2D PAT deutlich verkürzte Akquisitionszeiten bei gleich bleibender Auflösung erreicht werden.

Abstract

Purpose: In-vitro and in-vivo examinations to investigate the influence of one (1D)- and two-dimensional (2D) parallel acquisition techniques (PAT) on contrast-to-noise ratio (CNR) and image quality for bright-lumen 3D MR colonography. Materials and Methods: In-vitro measurements were performed on a 1.5 T whole-body MR scanner (MAGNETOM AVANTO®, Siemens AG, Erlangen) with a standard spoiled 3D gradient-echo (3D GRE) sequence and a volume interpolated 3D GRE (VIBE) sequence using a home-built colon phantom. The relative CNR was determined and image quality evaluated for different acceleration factors (PAT factors). A bright-lumen 3D MR colonography with PAT factors 2, 3, 4 and 6 was performed on a 39-year-old volunteer. The 3D data sets were compared with regard to image quality. Results: The mean relative CNR values for the in-vitro measurements were 1, 0.81, 0.73, 0.52 and 0.4 (3D GRE) and 1, 0.8, 0.65, 0.45 and 0.3 (VIBE) for the PAT factors 1, 2, 3, 4 and 6, respectively. Residual aliasing artifacts not affecting image quality in a distinct manner were visible for 2D PAT, especially for the VIBE sequence. Increasing the PAT factor up to 6 and decreasing the acquisition time down to 10 seconds for the bright-lumen 3D MR colonography could achieve adequate image quality with significantly reduced image artifacts caused by peristalsis and pulsations. Discussion: Even for high PAT factors up to 6, 2D PAT only leads to a moderate CNR loss. For a 3D MR colonography, distinct shorter acquisition times can be achieved with identical resolution.

References

  • 1 Lauenstein T C, Rühm S G, Debatin J F. State of the art of MR colonoscopy.  Fortschr Röntgenstr. 2003;  175 334-341
  • 2 Luboldt W, Steiner P, Bauerfeind P. et al . Detection of mass lesions with MR colonography.  Radiology. 1998;  207 59-65
  • 3 Luboldt W, Bauerfeind P, Wildermuth S. et al . Colonic masses: detection with MR colonography.  Radiology. 2000;  216 383-388
  • 4 Saar B, Rosch T, Rummeny E J. Colorectal cancer screening: a challenge for magnetic resonance colonography.  Magn Reson Imaging. 2002;  13 427-434
  • 5 Saar B, Heverhagen J T, Obst T. et al . Magnetic resonance colonography and virtual magnetic resonance colonography with the 1.0-T system: a feasibility study.  Invest Radiol. 2000;  35 512-526
  • 6 Pappalardo G, Polettini E, Frattaroli F M. et al . Magnetic resonance colonography versus conventional colonoscopy for the detection of colonic endoluminal lesions.  Gastroenterology. 2000;  119 300-304
  • 7 Luboldt W, Bauerfeind P, Pelkonen P. et al . 3D-MRI of the colon: methods and initial results.  Fortschr Röntgenstr. 1997;  167 252-256
  • 8 Lauenstein T C, Herborn C U, Vogt F M. et al . Dark lumen MR-colonograph: initial experience.  Fortschr Röntgenstr. 2001;  173 785-789
  • 9 Pruessmann K P, Weiger M, Scheidegger M B. et al . SENSE: Sensitivity Encoding for Fast MRI.  Magn Reson Med. 1999;  42 952-962
  • 10 Griswold M A, Jakob P M, Heidemann R M. et al . Generalized autocalibrating partially parallel aqcuisitions (GRAPPA).  Magn Reson Med. 2002;  47 1202-1210
  • 11 Rofsky N M, Lee F S, Laub G. et al . Abdominal MR imaging with a Volumetric Interpolated Breath-hold Examination.  Radiology. 1999;  212 876-884
  • 12 Walter C, Philippi G, Westerhausen R. et al . High resolution contrast-enhanced 3D MR-angiography of renal arteries using parallel imaging (SENSE).  Fortschr Röntgenstr. 2003;  175 1244-1250
  • 13 Quick H H, Vogt F M, Madewald S. et al . High spatial resolution whole-body MR angiography featuring parallel imaging: Initial Experience.  Fortschr Röntgenstr. 2004;  176 163-169

Günter Steidle

Sektion für Experimentelle Radiologie, Abteilung für Radiologische Diagnostik, Eberhard-Karls-Universität Tübingen

Hoppe-Seyler-Straße 3

72076 Tübingen

Phone: ++ 49/70 71/29-8 77 52

Fax: ++ 49/70 71/29-53 92

Email: guenter.steidle@med.uni-tuebingen.de

    >