Arrival Time Parametric Imaging: A New Ultrasound Technique for Quantifying Perfusion of Kidney Grafts

Arrival Time Parametric Imaging – Eine neue Ultraschallmethode zur Quantifizierung der renalen Perfusion nach NierentransplantationT. Fischer1 , S. Filimonow1 , J. Rudolph1 , S. Morgera2 , K. Budde2 , T. Slowinski2 , V. Ebeling3 , K. Taymoorian3 , M. Giessing3 , A. Thomas4
  • 1Dept. of Radiology, Charité – Universitätsmedizin Berlin, Campus Charité Mitte
  • 2Dept. of Nephrology, Charité – Universitätsmedizin Berlin, Campus Charité Mitte
  • 3Dept. of Urology, Charité – Universitätsmedizin Berlin, Campus Charité Mitte
  • 4Dept. of Gynaecology, Charité – Universitätsmedizin Berlin, Campus Charité Mitte
Further Information

Publication History

received: 27.12.2005

accepted: 31.8.2006

Publication Date:
21 February 2007 (online)

Zusammenfassung

Ziel: Auswertung einer neuen standardisierten Ultraschallmethode (US) zur Diagnostik der akuten Abstoßung von Nierentransplantaten. Material und Methoden: 22 Nierentransplantatempfänger wurden mittels Ultraschallkontrastmittel (USKM, 1,6 ml SonoVue®) am 6. postoperativen Tag untersucht. Eingesetzt wurde das Ultraschallsystem Aplio 80 (Toshiba™). Es wurde die Zeitdifferenz des ersten Signalintensitätsanstieges zwischen dem Bereich der A. renalis und des Nierenkortex bestimmt. Mittels windowsbasierter Software folgte die farbige Darstellung des zeitlichen Verlaufs der ersten 10 s nach Signalintensitätsgipfel im Bereich der A. renalis. Die resultierenden Bilder wurden mit entsprechender Farb- und Zeitskala versehen 3 Untersuchern vorgelegt. Mittels Analogskala von 1 (normal) bis 5 (pathologisch) wurden die Abbildungen verglichen. Ergebnisse: Zwölf der 22 Patienten zeigten einen komplikationslosen klinischen Verlauf. In der Kontrastmittel-Sonographie zeigte sich eine rasche Anflutung des USKM im Nierenkortex. Die berechnete Zeitdifferenz betrug 1,0 ± 0,4 s (Normalkollektiv). Die subjektive Bewertung der parametrischen Bilder ergab den Wert 1,7 ± 0,8. 8 der 22 Patienten wurden biopsiert und zeigten eine histologisch gesicherte Abstoßung. Die Zeitdifferenz in der Abstoßungsgruppe (2,2 ± 0,7 s, p < 0,05) war im Vergleich zum Normalkollektiv verdoppelt. Der Skalenwert der parametrischen Bilder war pathologisch (3,7 ± 1,6, p < 0,05). Zwei Patienten mit perirenalem Hämatom wiesen ebenfalls hohe Skalenwerte auf ohne Vorliegen einer Abstoßungsreaktion. Schlussfolgerung: Die akute Abstoßung und das perirenale Hämatom gehen mit einem verzögerten Signalanstieg im Nierenkortex einher. Diese Information lässt sich durch eine einzige Aufnahme mit standardisierter Farbdarstellung des zeitlichen Verlaufs der Kontrastmittelanflutung gewinnen.

Abstract

Purpose: Evaluation of a new standardised ultrasound (US) technique for diagnosis of acute rejection of kidney grafts. Materials and Methods: Twenty-two kidney recipients underwent US examination following administration of 1.6 ml US contrast medium (USCM, SonoVue™) 6 days after kidney transplantation. The examinations were performed with the Aplio US system (Toshiba™). The difference in time to the first increase in signal intensity between the renal artery and the renal cortex was determined. Subsequently, the temporal course of contrast enhancement in the area of the renal artery following the first peak was recorded over 10 sec and depicted in colour using a Windows-based software. The resulting colour-time-images were evaluated by three readers who rated the images on an analogue scale from 1 (normal) to 5 (abnormal). Results: 12 of the 22 patients had an uneventful clinical course. US demonstrated rapid inflow of the USCM into the renal cortex. The calculated time difference was 1.0 ± 0.4 sec. The score assigned to the parametric images was 1.7 ± 0.8. 8 of the 22 patients underwent biopsy and showed histologically proven rejection. The time difference in the rejection group was twice as high as in the normal group (2.2 ± 0.7 sec, p < 0.05). The scores were in the abnormal range (3.7 ± 1.6, p < 0.05). Two patients with perirenal haematoma also had high scores, without rejection. Conclusions: Acute rejection and perirenal haematoma are associated with a delayed signal increase in the renal cortex. This information can be provided with a single image with standardised colour display of the temporal course of USCM inflow.

References

  • 1 Pudszuhn A, Marx C, Malich A. et al . Prospective Analysis of Quantification of Contrast Media Enhanced Power Doppler Sonography of Equivocal Breast Lesions.  Fortschr Röntgenstr. 2003;  175 495-501
  • 2 Dietrich C F. 3D real time contrast enhanced ultrasonography, a new technique.  Fortschr Röntgenstr. 2002;  174 160-163
  • 3 Schlosser T, Pohl C, Veltmann C. et al . Feasibility of the flash-replenishment concept in renal tissue: which parameters affect the assessment of the contrast replenishment?.  Ultrasound Med Biol. 2001;  27 937-944
  • 4 Hohmann J, Skrok J, Puls R. et al . Characterization of focal liver lesions with contrast-enhanced low MI real time ultrasound and SonoVue.  Fortschr Röntgenstr. 2003;  175 835-843
  • 5 Quaia E, Bertolotto M, Calderan L. et al . US characterization of focal hepatic lesions with intermittent high-acoustic-power mode and contrast material.  Acad Radiol. 2003;  10 739-750
  • 6 Basilico R, Blomley M J, Harvey C J. et al . Which continuous US scanning mode is optimal for the detection of vascularity in liver lesions when enhanced with a second generation contrast agent?.  Eur J Radiol. 2002;  41 184-191
  • 7 Radermacher J, Mengel M, Ellis S. et al . The renal arterial resistance index and renal allograft survival.  N Engl J Med. 2003;  349 182-184
  • 8 Restrepo-Schafer I K, Schwerk W B, Muller T F. et al . Intrarenal doppler flow analysis in patients with kidney transplantation and stable transplant function.  Ultraschall in Med. 1999;  20 87-92
  • 9 Martinoli C, Bertolotto M, Crespi G. et al . Duplex Doppler analysis of interlobular arteries in transplanted kidneys.  Eur Radiol. 1998;  8 765-769
  • 10 Takano R, Ando Y, Taniguchi N. et al . Power Doppler sonography of the kidney: effect of Valsalva’s maneuver.  J Clin Ultrasound. 2001;  29 384-390
  • 11 Schwerk W B, Restrepo I K, Prinz H. Semiquantitative analysis of intrarenal arterial Doppler flow spectra in healthy adults.  Ultraschall in Med. 1993;  14 117-122
  • 12 Fischer T, Mühler M, Kröncke T J. et al . Early Postoperative Ultrasound of Kidney Transplants: Evaluation of Contrast Medium Dynamics Using Time-intensity Curves.  Fortschr Röntgenstr. 2004;  176 472-477
  • 13 Wei K, Le E, Bin J P. et al . Quantification of renal blood flow with contrast-enhanced ultrasound.  J Am Coll Cardiol. 2001;  37 1135-1140
  • 14 Girard M S, Mattrey R F, Baker K G. et al . Comparison of Standard and Second Harmonic B-mode Sonography in the Detection of Segmental Renal Infarction with SonographicContrast in a Rabbit Model.  J Ultrasound Med. 2000;  19 185-192
  • 15 Bokor D, Chambers J B, Rees P J. et al . Clinical safety of SonoVue, a new contrast agent for ultrasound imaging, in healthy volunteers and in patients with chronic obstructive pulmonary disease.  Invest Radiol. 2001;  36 104-109
  • 16 Nahar T, Li P, Kuersten B. et al . Detection of resting myocardial perfusion defects by SonoVue myocardial contrast echocardiography.  Echocardiography. 2003;  20 511-517
  • 17 Bouakaz A, Krenning B J, Vletter W B. et al . Contrast superharmonic imaging: a feasibility study.  Ultrasound Med Biol. 2003;  29 547-553
  • 18 Lorriaux C, Pouteil-Noble C, Dijoud F. et al . Clinical Correlation of Acute Rejection According to Banff Classification in Renal Transplantation.  Transplantation Proceedings. 2000;  32 443-444
  • 19 Palomar R, Ruiz J C, Zubimendi J A. et al . Clinical Validation of the Banff 97 Classification for the Diagnosis of Rejection in Kidney Transplant.  Transplantation Proceedings. 2001;  33 3309
  • 20 Waiser J, Schreiber M, Budde K. et al . Prognostic value of the Banff classification.  Transpl Int. 2000;  13 106-111
  • 21 Seeler D, Klinggräff G v, Christl S U. Sonographic Detection of Kidney Infarctions Using Ultrasound Contrast Media.  Ultraschall in Med. 2005;  26 518-523
  • 22 Deeg K H, Wörle K, Wolf A. Doppler Sonographic Estimation of Normal Values for Flow Velocity and Resistance Indices in Renal Arteries of Healthy Infants.  Ultraschall in Med. 2003;  24 312-322

Dr. med. Thomas Fischer

Institut für Radiologie, Charité, Universitätsmedizin Berlin, Campus Charité Mitte

Schumannstraße 20/21

10098 Berlin

Germany

Phone: ++49/30/4 50 52 70 82

Fax: ++49/30/4 50 52 79 11

Email: thom.fischer@charite.de

    >