Computerized optimization of multiple isocentres in stereotactic convergent beam irradiation

, , , and

Published under licence by IOP Publishing Ltd
, , Citation U Treuer et al 1998 Phys. Med. Biol. 43 49 DOI 10.1088/0031-9155/43/1/004

0031-9155/43/1/49

Abstract

A method for the fully computerized determination and optimization of positions of target points and collimator sizes in convergent beam irradiation is presented. In conventional interactive trial and error methods, which are very time consuming, the treatment parameters are chosen according to the operator's experience and improved successively. This time is reduced significantly by the use of a computerized procedure. After the definition of target volume and organs at risk in the CT or MR scans, an initial configuration is created automatically. In the next step the target point positions and collimator diameters are optimized by the program. The aim of the optimization is to find a configuration for which a prescribed dose at the target surface is approximated as close as possible. At the same time dose peaks inside the target volume are minimized and organs at risk and tissue surrounding the target are spared. To enhance the speed of the optimization a fast method for approximate dose calculation in convergent beam irradiation is used. A possible application of the method for calculating the leaf positions when irradiating with a micromultileaf collimator is briefly discussed. The success of the procedure has been demonstrated for several clinical cases with up to six target points.