Abstract

Objectives

Alternative techniques to assess physical exposures, such as prediction models, could facilitate more efficient epidemiological assessments in future large cohort studies examining physical exposures in relation to work-related musculoskeletal symptoms. The aim of this study was to evaluate two types of models that predict arm-wrist-hand physical exposures (i.e. muscle activity, wrist postures and kinematics, and keyboard and mouse forces) during computer use, which only differed with respect to the candidate predicting variables; (i) a full set of predicting variables, including self-reported factors, software-recorded computer usage patterns, and worksite measurements of anthropometrics and workstation set-up (full models); and (ii) a practical set of predicting variables, only including the self-reported factors and software-recorded computer usage patterns, that are relatively easy to assess (practical models).

Methods

Prediction models were build using data from a field study among 117 office workers who were symptom-free at the time of measurement. Arm-wrist-hand physical exposures were measured for approximately two hours while workers performed their own computer work. Each worker’s anthropometry and workstation set-up were measured by an experimenter, computer usage patterns were recorded using software and self-reported factors (including individual factors, job characteristics, computer work behaviours, psychosocial factors, workstation set-up characteristics, and leisure-time activities) were collected by an online questionnaire. We determined the predictive quality of the models in terms of R2 and root mean squared (RMS) values and exposure classification agreement to low-, medium-, and high-exposure categories (in the practical model only).

Results

The full models had R2 values that ranged from 0.16 to 0.80, whereas for the practical models values ranged from 0.05 to 0.43. Interquartile ranges were not that different for the two models, indicating that only for some physical exposures the full models performed better. Relative RMS errors ranged between 5% and 19% for the full models, and between 10% and 19% for the practical model. When the predicted physical exposures were classified into low, medium, and high, classification agreement ranged from 26% to 71%.

Conclusion

The full prediction models, based on self-reported factors, software-recorded computer usage patterns, and additional measurements of anthropometrics and workstation set-up, show a better predictive quality as compared to the practical models based on self-reported factors and recorded computer usage patterns only. However, predictive quality varied largely across different arm-wrist-hand exposure parameters. Future exploration of the relation between predicted physical exposure and symptoms is therefore only recommended for physical exposures that can be reasonably well predicted.

Introduction

Work-related upper extremity symptoms are a prevalent and expensive problem among office workers (Blatter et al., 2005; Eltayeb et al., 2009; Hagberg et al., 2007; Van den Heuvel et al., 2007). Better knowledge of exposure-response relationships during computer use can guide efforts to reduce the occurrence of symptoms. The most accepted possible injury mechanism states that individual and occupational factors could increase physical exposure of the worker (e.g. muscle activity, forceful exertions or non-neutral body postures), which over time could result in tissue damage and upper extremity symptoms (Gerr et al., 2004; Punnett and Wegman, 2004; Gerr et al., 2006; Visser and Van Dieën, 2006; Bleecker and Barnes, 2012). The plausibility of this hypothesis should be investigated by relating accurately assessed physical exposure to upper extremity symptoms, preferably in large cohorts with longitudinal data.

Direct measurements of exposures, such as by electromyography (EMG), video analyses and motion caption systems, are considered superior to self-reported measurements because they are more accurate and less subject to bias (Winkel and Mathiassen, 1994). However, such measurements can be expensive, time consuming, and difficult to use at worksites (Hansson et al., 2001; Balogh et al., 2004; Trask et al., 2007; Trask et al., 2014). Therefore, in large longitudinal cohort studies, researchers tend to rely on self-reports of physical exposure. An alternative physical exposure assessment method may be to estimate exposure through the use of prediction models (Chen et al., 2004; Bruno Garza et al., 2014; Heiden et al., 2016).

Recently, the predictive quality of prediction models developed to assess office workers’ neck-shoulder physical exposures (i.e. trapezius muscle activity and shoulder, head, neck, and torso postures) was examined in the PRedicting Occupational biomechanics in OFfice workers (PROOF) study, demonstrating the feasibility of such models (Bruno Garza et al., 2014). These models were based on self-reported individual, psychosocial and work characteristics, software-recorded computer usage patterns, and measurements of anthropometrics and workstation set-up. The results from this study indicated that some of the exposure outcomes could be reasonably well predicted (maximum R2 = 0.59). Compared to neck-shoulder physical exposures, arm-wrist-hand exposures are expected to be more task-related and computer usage characteristics (i.e. % keyboard use, % mouse use, and % idle time) might affect the predictive quality of arm-wrist-hand and neck-shoulder prediction models differently.

Our goal was to develop and evaluate two types of models that predict arm-wrist-hand physical exposures (i.e. muscle activity, wrist postures and kinematics, and keyboard and mouse forces) during computer use. These models differ in the kind of candidate predicting variables that were entered into the model. The first models, using a full set of predicting variables, assessed by self-report, software-recorded compute usage, and additional worksite measurements of anthropometrics and workstation set-up, are aimed at reaching maximum achievable predictive quality (full models). The second models will be build using only predicting variables that are relatively easy to assess, i.e. self-reported factors and software-recorded computer usage patterns (practical models). It was our goal to examine how well both types of models performed in terms of predictive quality compared to direct measurements of physical exposures. Since in epidemiological studies often categorized variables are used, for the practical models we also examined the classification agreement when the predicted exposures of these models were categorized into low, medium, and high. The aims of this study were therefore to:

  • 1. Determine the predictive quality of arm-wrist-hand physical exposures (i.e. muscle activity, wrist postures and kinematics, and keyboard and mouse forces) through prediction models based on the full set of predicting variables (full models).

  • 2. Determine the predictive quality and agreement between predicted and observed exposures if categorized into low, medium, and high, of arm-wrist-hand physical exposures through prediction models based on predicting variables that are relatively easy to assess (practical models).

Methods

Experimental design and selection of participants

This study is part of the PROOF study, in which physical exposures during computer work in a realistic work setting were assessed among 120 office workers (Bruno Garza et al., 2012). Forearm muscle activity, wrist postures, and forces applied to the keyboard and computer mouse were directly measured for ~2 h while the workers performed their own work at their own workstations. Additionally, each worker’s anthropometry and set-up of his/her workstation were measured by an experimenter, characteristics of his/her computer use were recorded using a software program installed on the workers’ computer. Individual, workstation set-up and job characteristics, computer work behaviours, and psychosocial factors were collected via self-report using an online questionnaire.

All office workers were employed at either VU University (across eight different departments) or VU University Medical Center in Amsterdam, The Netherlands. Workers were invited to participate if their main tasks included computer work, they were free of musculoskeletal symptoms in the neck, shoulders, arms, wrists, and/or hands for at least 1 week prior to data collection, worked at least 20 h per week according to their contract, and were comfortable using a computer mouse with their right hand. Before the start of the data collection, participants gave written consent. All protocols and informed consent forms were approved by the Harvard School of Public Health Human Subjects Committee, the Medical Ethics Committee of the VU University Medical Center, and the Ethics Committee of the Faculty of Human Movement Sciences of VU University Amsterdam.

Data collection and data processing

Computer interaction activities (keyboard use, mouse use, and idle time)

Computer input device usage was recorded using computer interaction monitoring software, assessing each participant’s computer activity episodes (i.e. any period within 30 s of pressing a key, clicking a button on the mouse, or moving the mouse) and non-computer activity episodes (i.e. any period without computer input device usage for at least 30 s; Chang et al., 2008; Hwang et al., 2010). We also calculated the percentages of keyboard, mouse, and idle time during computer use. Keyboard activity was defined as a series of keyboard events (key strikes) that had <2 s of inactivity between successive keyboard events. Mouse activity was defined as a series of mouse events (mouse movement, scrolling, or button clicks) with <2 s of inactivity between successive events. Idle time was defined as any period of keyboard or mouse inactivity that lasted at least 2 s but <30 s (Dennerlein and Johnson, 2006; Chang et al., 2008; Yeh et al., 2009).

Physical exposures: wrist extensor muscle activity, wrist postures and kinematics, and forces applied to the computer mouse and keyboard

Left and right extensor carpi radialis (ECR) muscle activity were measured using surface EMG with a wireless logger system (Mega WBA, Mega Electronics LTD, Kupio, Finland). Electrodes (12 mm diameter Ambu Bluesensor N-00-S surface electrodes) were mounted over the muscle bellies with 20 mm inter-electrode spacing (Basmajian, 1989). Data were recorded at 1000 Hz after amplification (bandwidth of 10–500 Hz), then smoothened using a 3-Hz second-order, zero-phase, low–pass Butterworth filter, and down-sampled to 40 samples per second using a mean filtering procedure.

For each participant, three maximum voluntary contractions (MVCs) were collected from the right and left ECR muscle, by radially deviating and extending a fist of his/her hand against resistance applied by the experimenter. There was at least 1 min of rest in between MVCs. Each muscle’s MVC was the highest 1-s average of the EMG amplitudes collected from the three measurements.

Median (P50) wrist extensor muscle activity during computer use was calculated for each participant and normalized to the MVC (% MVC). Static (P10) and peak (P90) muscle activity were not analysed, since these measures were expected to be closely correlated to median muscle activity.

Left and right wrist flexion-extension and radial-ulnar deviation were measured using twin axis electrogoniometers (Model SG65, Biometrics Ltd, Gwent, UK), which were mounted over the back of the hand and the forearm with the wrist in a neutral position (i.e. hands pronated, middle metacarpal aligned with the midline of the forearm and dorsal aspect of the hand aligned with dorsal aspect of the forearm). Data were recorded at 1000 Hz with the same wireless data logging system used to collect muscle activity. Wrist posture data were filtered through a 5-Hz second-order, zero-phase, low-pass Butterworth filter, down-sampled to 40 Hz, and expressed as deviations from a participant’s neutral posture, which was recorded at the beginning of the data collection.

Median (P50) wrist postures, expressed in degrees, were calculated for each participant. Wrist velocities and accelerations were calculated by digitally differentiating the posture data and expressed in root mean squared (RMS) values. Only data of wrist postures, velocities, and accelerations during computer interactions were used.

Keyboard force was measured by placing each participant’s keyboard on top of a force plate with three miniature compression load cells (ELFF-B4-10L, Measurement Specialties, Hampton, VA, USA) mounted underneath in a triangular pattern (Asundi et al., 2009). Mouse grip force was measured using a modified USB mouse with scroll wheel (Model 3902C693, Microsoft, Inc., Redmond, WA, USA). Three compression load cells (ELW-D1-10L, Measurement Specialties, Hampton, VA, USA) were mounted inside the mouse (Johnson et al., 2000). This force-sensing mouse was designed to be operated with the right hand, measuring thumb forces applied to the mouse. Participants were asked to use this force-sensing mouse instead of their own computer mouse for the duration of the measurements.

Keyboard and the mouse force data were collected with USB backplanes (NI cDAQ-9172; National Instruments: Austin, TX, USA) and sampled at 10000 Hz, then low-pass filtered at 20 Hz (6th order Butterworth filter), down-sampled to 40 Hz. Three maximum voluntary force (MVFs) exertions were collected per participant, with 1 min of rest in between. Maximal keyboard force was measured by requiring a participant to maximally press down the “J” key with their right index finger for 5 s, and maximal mouse force by requiring a participant to maximally squeeze the mouse for 5 s. Maximum forces were measured while a participant adopted the same posture as during actual keyboard or mouse work. MVF values were the highest 1-s averages of the three collected MVFs. For each participant median (P50) keyboard and mouse force were calculated.

Predicting variables: Questionnaire, anthropometry, and workstation set-up

Self-reported factors, including (i) individual factors, (ii) job characteristics, (iii) computer work behaviours, (iv) psychosocial factors (Cohen et al., 1983; Siegrist, 1996; Schreurs and De Ridder, 1997; Karasek et al., 1998; Sluiter et al., 1999; Van Veldhoven and Broersen, 2003; Siegrist et al., 2004), (v) workstation set-up characteristics, and (vi) leisure-time activities, were collected through an online questionnaire (IJmker et al., 2006). Measures of anthropometry (item 12–16, Part 3 of the Supplementary Material, available at Annals of Work Exposures and Health online) and workstation set-up (item 77–92, Part 3 of the Supplementary Material, available at Annals of Work Exposures and Health online) were observed using a tape-measure and collected by the same experimenter for all participants throughout the whole data collection. For the anthropometry measures, definitions of Won and colleagues (2009) were used, while the workstation set-up measures were derived from Marcus and colleagues (2002). All predicting variables were theoretically related to physical exposures or upper extremity symptoms and are listed in Part 3 of the Supplementary Material (available at Annals of Work Exposures and Health online), including the response categories and references.

Prediction models

A: Full models; predictions based on self-reported factors, software-recorded computer usage patterns, and additional worksite measurements of anthropometrics and workstation set-up

Predictions of continuous arm-wrist-hand physical exposures (i.e. ECR muscle activity, wrist postures and kinematics, and keyboard and mouse forces) were calculated from linear regression models (IBM SPSS Statistics 20). In the prediction models, both continuous and categorical variables were used. For continuous variables, effects sizes (e.g., betas and corresponding P values) were modelled per unit of the variable, while for categorical variables effect sizes were modelled across categories. At the start of the selection procedure, we assigned all 98 variables to six different categories (individual characteristics, job characteristics, computer work behaviours, psychosocial factors, workstation set-up, and leisure-time activities, see Part 3 of the Supplementary Material, available at Annals of Work Exposures and Health online). Because we had a large number of predicting variables, we developed the prediction models following a three-step procedure, comparable to the procedure of Bruno Garza and colleagues (2014) for developing neck-shoulder physical exposure prediction models.

Step 1: We determined the univariate associations between all 98 predicting and the physical exposure outcomes. Associations with a two-tailed significance level of P <0.20 were identified and selected for further analyses.

Step 2: Per category, all remaining variables from Step 1 were included in a backward selection procedure with P removal set at P <0.20. This tolerant P value was chosen in order to retain sufficient variables for the final selection step. Prior to this, however, pairwise correlations between all factors within each category were calculated. In cases where two variables were strongly correlated (with a Pearson r ≥ 0.70), only the variable with the largest relative dispersion (i.e. the highest coefficient of variation) within the data set was retained to avoid collinearity, as per earlier work (Heiden et al., 2016).

Step 3: The variables remaining after Step 2 from all six categories were included in another backward selection procedure with a P removal set at P <0.10 for the selection of the final set of variables for each prediction model. A P value of P <0.10 was chosen following the Akaike Information Criterion and the Schwarz Bayesian Criterion. Also, prior to this this step, pairwise correlations between all factors was calculated, while only the variable with the largest relative dispersion within the data set was retained in case of strong correlation.

To determine the predictive quality of the final models, R2 values, absolute, and relative RMS errors were calculated. We calculated the relative RMS error by dividing the RMS error by the range of the observed values and then multiplying by 100 percent (Table 1). Also, beta, standard error, and P value depicting the association of each of the factors with the outcome in each model were outputted. In order to internally validate the final models, a bootstrap procedure was conducted, in which a total of 1000 samples were drawn from the original data set. Average beta, standard error, and P values over these samples from each of the studied associations were estimated.

Table 1.

Prediction models based on self-reported factors, software-recorded computer usage patterns, and anthropometric and workstation measurements, using exposure data of 117 office workers collected during computer work at their own workstation.

R2RMSRelative RMS (%)Individual factorsJob characteristicsComputer work behaviorsPsychosocial factorsWorkstation set-upLeisure-time activitiesTotal number of predicting variables
Wrist muscle activity (%MVC)
 Left ECR0.411.8167, 162838, 41, 465863, 65, 7510
 Right ECR0.402.4191, 1620,2539, 455276979
Wrist Posture (degrees)
 Left flexion-extension0.1610.6136, 742754
 Left radial-ulnar deviation0.347.711818,19,22,2536, 4676, 889
 Right flexion-extension0.2310.51242, 4874, 75, 87, 91987
 Right radial-ulnar deviation0.196.912142, 4756815
Wrist velocity (degrees/s)
 Left flexion-extension0.245.11315183363975
 Left radial-ulnar deviation0.262.8156, 132078, 88, 905
 Right flexion-extension0.386.8111524,2641, 468194, 978
 Right radial-ulnar deviation0.563.2912, 13, 14, 1520,2743, 47, 4857, 6587, 919714
Wrist acceleration (degrees/s2)
 Left flexion-extension0.3871.1132, 1318,1933, 3854, 63979
 Left radial-ulnar deviation0.3835.11513284653, 5478, 86, 88, 909
 Right flexion-extension0.5299.9112, 13, 1518,24,2641, 46548094, 95, 9713
 Right radial-ulnar deviation0.3954.510121947, 4857, 656
Force (%MVF)
 Keyboard0.800.6510, 1467974
 Mouse0.480.41010354649, 57, 6479, 84989
R2RMSRelative RMS (%)Individual factorsJob characteristicsComputer work behaviorsPsychosocial factorsWorkstation set-upLeisure-time activitiesTotal number of predicting variables
Wrist muscle activity (%MVC)
 Left ECR0.411.8167, 162838, 41, 465863, 65, 7510
 Right ECR0.402.4191, 1620,2539, 455276979
Wrist Posture (degrees)
 Left flexion-extension0.1610.6136, 742754
 Left radial-ulnar deviation0.347.711818,19,22,2536, 4676, 889
 Right flexion-extension0.2310.51242, 4874, 75, 87, 91987
 Right radial-ulnar deviation0.196.912142, 4756815
Wrist velocity (degrees/s)
 Left flexion-extension0.245.11315183363975
 Left radial-ulnar deviation0.262.8156, 132078, 88, 905
 Right flexion-extension0.386.8111524,2641, 468194, 978
 Right radial-ulnar deviation0.563.2912, 13, 14, 1520,2743, 47, 4857, 6587, 919714
Wrist acceleration (degrees/s2)
 Left flexion-extension0.3871.1132, 1318,1933, 3854, 63979
 Left radial-ulnar deviation0.3835.11513284653, 5478, 86, 88, 909
 Right flexion-extension0.5299.9112, 13, 1518,24,2641, 46548094, 95, 9713
 Right radial-ulnar deviation0.3954.510121947, 4857, 656
Force (%MVF)
 Keyboard0.800.6510, 1467974
 Mouse0.480.41010354649, 57, 6479, 84989

Predictor numbers refer to Part 3 of the Supplementary Material (available at Annals of Work Exposures and Health online). Numbers printed in bold represent additional worksite measurements of anthropometrics and workstation set-up, which were excluded from selection for the prediction models of Table 2.

Table 1.

Prediction models based on self-reported factors, software-recorded computer usage patterns, and anthropometric and workstation measurements, using exposure data of 117 office workers collected during computer work at their own workstation.

R2RMSRelative RMS (%)Individual factorsJob characteristicsComputer work behaviorsPsychosocial factorsWorkstation set-upLeisure-time activitiesTotal number of predicting variables
Wrist muscle activity (%MVC)
 Left ECR0.411.8167, 162838, 41, 465863, 65, 7510
 Right ECR0.402.4191, 1620,2539, 455276979
Wrist Posture (degrees)
 Left flexion-extension0.1610.6136, 742754
 Left radial-ulnar deviation0.347.711818,19,22,2536, 4676, 889
 Right flexion-extension0.2310.51242, 4874, 75, 87, 91987
 Right radial-ulnar deviation0.196.912142, 4756815
Wrist velocity (degrees/s)
 Left flexion-extension0.245.11315183363975
 Left radial-ulnar deviation0.262.8156, 132078, 88, 905
 Right flexion-extension0.386.8111524,2641, 468194, 978
 Right radial-ulnar deviation0.563.2912, 13, 14, 1520,2743, 47, 4857, 6587, 919714
Wrist acceleration (degrees/s2)
 Left flexion-extension0.3871.1132, 1318,1933, 3854, 63979
 Left radial-ulnar deviation0.3835.11513284653, 5478, 86, 88, 909
 Right flexion-extension0.5299.9112, 13, 1518,24,2641, 46548094, 95, 9713
 Right radial-ulnar deviation0.3954.510121947, 4857, 656
Force (%MVF)
 Keyboard0.800.6510, 1467974
 Mouse0.480.41010354649, 57, 6479, 84989
R2RMSRelative RMS (%)Individual factorsJob characteristicsComputer work behaviorsPsychosocial factorsWorkstation set-upLeisure-time activitiesTotal number of predicting variables
Wrist muscle activity (%MVC)
 Left ECR0.411.8167, 162838, 41, 465863, 65, 7510
 Right ECR0.402.4191, 1620,2539, 455276979
Wrist Posture (degrees)
 Left flexion-extension0.1610.6136, 742754
 Left radial-ulnar deviation0.347.711818,19,22,2536, 4676, 889
 Right flexion-extension0.2310.51242, 4874, 75, 87, 91987
 Right radial-ulnar deviation0.196.912142, 4756815
Wrist velocity (degrees/s)
 Left flexion-extension0.245.11315183363975
 Left radial-ulnar deviation0.262.8156, 132078, 88, 905
 Right flexion-extension0.386.8111524,2641, 468194, 978
 Right radial-ulnar deviation0.563.2912, 13, 14, 1520,2743, 47, 4857, 6587, 919714
Wrist acceleration (degrees/s2)
 Left flexion-extension0.3871.1132, 1318,1933, 3854, 63979
 Left radial-ulnar deviation0.3835.11513284653, 5478, 86, 88, 909
 Right flexion-extension0.5299.9112, 13, 1518,24,2641, 46548094, 95, 9713
 Right radial-ulnar deviation0.3954.510121947, 4857, 656
Force (%MVF)
 Keyboard0.800.6510, 1467974
 Mouse0.480.41010354649, 57, 6479, 84989

Predictor numbers refer to Part 3 of the Supplementary Material (available at Annals of Work Exposures and Health online). Numbers printed in bold represent additional worksite measurements of anthropometrics and workstation set-up, which were excluded from selection for the prediction models of Table 2.

Table 2.

Prediction models based on self-reported factors and software-recorded computer usage patterns (practical models), using exposure data of 117 office workers collected during computer work at their own workstation.

R2RMSRelative RMS (%)Individual factorsJob characteristicsComputer work behaviorsPsychosocial factorsWorkstation set-upLeisure-time activitiesTotal number of predicting variables
Wrist muscle activity (%MVC)
 Left ECR0.431.7152,72838, 41, 4658, 63, 65759711
 Right ECR0.362.519120, 25455271, 76978
Wrist Posture (degrees)
 Left flexion-extension0.1610.6136,742754
 Left radial-ulnar deviation0.307.91119, 22, 2536, 4657767
 Right flexion-extension0.1710.81242, 4874, 75985
 Right radial-ulnar deviation0.186.9121,102542565
Wrist velocity (degrees/s)
 Left flexion-extension0.215.213183363974
 Left radial-ulnar deviation0.083.11623722
 Right flexion-extension0.327.112718, 24, 2641, 465475979
 Right radial-ulnar deviation0.343.711231, 36, 43, 47, 48577
Wrist acceleration (degrees/s2)
 Left flexion-extension0.3174.314433, 38, 4854, 63977
 Left radial-ulnar deviation0.2337.8164,9234654726
 Right flexion-extension0.38111.012218,2441, 485494, 95, 979
 Right radial-ulnar deviation0.3556.01031947, 4857, 656
Force (%MVF)
 Keyboard0.051.21010672
 Mouse0.340.511103546, 4757, 64987
R2RMSRelative RMS (%)Individual factorsJob characteristicsComputer work behaviorsPsychosocial factorsWorkstation set-upLeisure-time activitiesTotal number of predicting variables
Wrist muscle activity (%MVC)
 Left ECR0.431.7152,72838, 41, 4658, 63, 65759711
 Right ECR0.362.519120, 25455271, 76978
Wrist Posture (degrees)
 Left flexion-extension0.1610.6136,742754
 Left radial-ulnar deviation0.307.91119, 22, 2536, 4657767
 Right flexion-extension0.1710.81242, 4874, 75985
 Right radial-ulnar deviation0.186.9121,102542565
Wrist velocity (degrees/s)
 Left flexion-extension0.215.213183363974
 Left radial-ulnar deviation0.083.11623722
 Right flexion-extension0.327.112718, 24, 2641, 465475979
 Right radial-ulnar deviation0.343.711231, 36, 43, 47, 48577
Wrist acceleration (degrees/s2)
 Left flexion-extension0.3174.314433, 38, 4854, 63977
 Left radial-ulnar deviation0.2337.8164,9234654726
 Right flexion-extension0.38111.012218,2441, 485494, 95, 979
 Right radial-ulnar deviation0.3556.01031947, 4857, 656
Force (%MVF)
 Keyboard0.051.21010672
 Mouse0.340.511103546, 4757, 64987

Predictor numbers refer to Part 3 of the Supplementary Material (available at Annals of Work Exposures and Health online).

Table 2.

Prediction models based on self-reported factors and software-recorded computer usage patterns (practical models), using exposure data of 117 office workers collected during computer work at their own workstation.

R2RMSRelative RMS (%)Individual factorsJob characteristicsComputer work behaviorsPsychosocial factorsWorkstation set-upLeisure-time activitiesTotal number of predicting variables
Wrist muscle activity (%MVC)
 Left ECR0.431.7152,72838, 41, 4658, 63, 65759711
 Right ECR0.362.519120, 25455271, 76978
Wrist Posture (degrees)
 Left flexion-extension0.1610.6136,742754
 Left radial-ulnar deviation0.307.91119, 22, 2536, 4657767
 Right flexion-extension0.1710.81242, 4874, 75985
 Right radial-ulnar deviation0.186.9121,102542565
Wrist velocity (degrees/s)
 Left flexion-extension0.215.213183363974
 Left radial-ulnar deviation0.083.11623722
 Right flexion-extension0.327.112718, 24, 2641, 465475979
 Right radial-ulnar deviation0.343.711231, 36, 43, 47, 48577
Wrist acceleration (degrees/s2)
 Left flexion-extension0.3174.314433, 38, 4854, 63977
 Left radial-ulnar deviation0.2337.8164,9234654726
 Right flexion-extension0.38111.012218,2441, 485494, 95, 979
 Right radial-ulnar deviation0.3556.01031947, 4857, 656
Force (%MVF)
 Keyboard0.051.21010672
 Mouse0.340.511103546, 4757, 64987
R2RMSRelative RMS (%)Individual factorsJob characteristicsComputer work behaviorsPsychosocial factorsWorkstation set-upLeisure-time activitiesTotal number of predicting variables
Wrist muscle activity (%MVC)
 Left ECR0.431.7152,72838, 41, 4658, 63, 65759711
 Right ECR0.362.519120, 25455271, 76978
Wrist Posture (degrees)
 Left flexion-extension0.1610.6136,742754
 Left radial-ulnar deviation0.307.91119, 22, 2536, 4657767
 Right flexion-extension0.1710.81242, 4874, 75985
 Right radial-ulnar deviation0.186.9121,102542565
Wrist velocity (degrees/s)
 Left flexion-extension0.215.213183363974
 Left radial-ulnar deviation0.083.11623722
 Right flexion-extension0.327.112718, 24, 2641, 465475979
 Right radial-ulnar deviation0.343.711231, 36, 43, 47, 48577
Wrist acceleration (degrees/s2)
 Left flexion-extension0.3174.314433, 38, 4854, 63977
 Left radial-ulnar deviation0.2337.8164,9234654726
 Right flexion-extension0.38111.012218,2441, 485494, 95, 979
 Right radial-ulnar deviation0.3556.01031947, 4857, 656
Force (%MVF)
 Keyboard0.051.21010672
 Mouse0.340.511103546, 4757, 64987

Predictor numbers refer to Part 3 of the Supplementary Material (available at Annals of Work Exposures and Health online).

B: Practical models; predictions based on self-reported factors and software-recorded computer usage patterns

For the practical models, that estimated continuous arm-wrist-hand exposures based on self-reported factors and software-recorded computer usage only, we followed the exact same three-step procedure as described above. At the start of this procedure, all 21 manually recorded anthropometry and workstation set-up variables were removed from the complete set of 98 variables. The variables body weight and calculated BMI, for which we used manually recorded data in the prediction models under A, were substituted with self-reported data. Even though the 3-step procedure was exactly the same for the full models and the practical models, the content of these models in terms of predicting variables ending up in the final models is likely to be different, because of the difference in candidate predicting variables that were entered into the models.

Other than for the full models, we classified all observed and predicted physical exposure outcomes from the prediction models based on self-reported factors and software-recorded computer usage patterns into low, medium, and high categories, using tertiles. We then determined the classification agreement between observed and predicted outcomes by calculating the percentage of agreement per group (Table 3).

Table 3.

Agreement of classifying observed and predicted exposures to low, medium, and high tertiles.

LowMediumHigh
% Correctly predicteda% Correctly predicteda% Correctly predicteda
Wrist muscle activity (%MVC)
 Left ECR71.153.861.5
 Right ECR55.346.271.1
Wrist Posture (degrees)
 Left flexion-extension48.735.948.7
 Left radial-ulnar deviation56.443.651.3
 Right flexion-extension38.538.5
 Right radial-ulnar deviation55.336.846.2
Wrist velocity (degrees/s)
 Left flexion-extension50.038.565.8
 Left radial-ulnar deviation71.434.850.0
 Right flexion-extension56.435.161.5
 Right radial-ulnar deviation59.546.261.5
Wrist acceleration (degrees/s2)
 Left flexion-extension47.431.657.9
 Left radial-ulnar deviation46.238.554.1
 Right flexion-extension60.536.864.1
 Right radial-ulnar deviation57.938.556.8
Force (%MVF)
 Keyboard41.026.352.5
 Mouse63.246.264.1
LowMediumHigh
% Correctly predicteda% Correctly predicteda% Correctly predicteda
Wrist muscle activity (%MVC)
 Left ECR71.153.861.5
 Right ECR55.346.271.1
Wrist Posture (degrees)
 Left flexion-extension48.735.948.7
 Left radial-ulnar deviation56.443.651.3
 Right flexion-extension38.538.5
 Right radial-ulnar deviation55.336.846.2
Wrist velocity (degrees/s)
 Left flexion-extension50.038.565.8
 Left radial-ulnar deviation71.434.850.0
 Right flexion-extension56.435.161.5
 Right radial-ulnar deviation59.546.261.5
Wrist acceleration (degrees/s2)
 Left flexion-extension47.431.657.9
 Left radial-ulnar deviation46.238.554.1
 Right flexion-extension60.536.864.1
 Right radial-ulnar deviation57.938.556.8
Force (%MVF)
 Keyboard41.026.352.5
 Mouse63.246.264.1

Observed and predicted exposures based on data of 117 office workers, collected during computer work at their own workstation. Means (SD) and ranges of limits of exposure are given for observed physical exposures. Predictions are based on self-reported factors and software-recorded computer usage patterns. Abbreviation: SD = standard deviation.

a% Observed from total % predicted low, medium, or high.

Table 3.

Agreement of classifying observed and predicted exposures to low, medium, and high tertiles.

LowMediumHigh
% Correctly predicteda% Correctly predicteda% Correctly predicteda
Wrist muscle activity (%MVC)
 Left ECR71.153.861.5
 Right ECR55.346.271.1
Wrist Posture (degrees)
 Left flexion-extension48.735.948.7
 Left radial-ulnar deviation56.443.651.3
 Right flexion-extension38.538.5
 Right radial-ulnar deviation55.336.846.2
Wrist velocity (degrees/s)
 Left flexion-extension50.038.565.8
 Left radial-ulnar deviation71.434.850.0
 Right flexion-extension56.435.161.5
 Right radial-ulnar deviation59.546.261.5
Wrist acceleration (degrees/s2)
 Left flexion-extension47.431.657.9
 Left radial-ulnar deviation46.238.554.1
 Right flexion-extension60.536.864.1
 Right radial-ulnar deviation57.938.556.8
Force (%MVF)
 Keyboard41.026.352.5
 Mouse63.246.264.1
LowMediumHigh
% Correctly predicteda% Correctly predicteda% Correctly predicteda
Wrist muscle activity (%MVC)
 Left ECR71.153.861.5
 Right ECR55.346.271.1
Wrist Posture (degrees)
 Left flexion-extension48.735.948.7
 Left radial-ulnar deviation56.443.651.3
 Right flexion-extension38.538.5
 Right radial-ulnar deviation55.336.846.2
Wrist velocity (degrees/s)
 Left flexion-extension50.038.565.8
 Left radial-ulnar deviation71.434.850.0
 Right flexion-extension56.435.161.5
 Right radial-ulnar deviation59.546.261.5
Wrist acceleration (degrees/s2)
 Left flexion-extension47.431.657.9
 Left radial-ulnar deviation46.238.554.1
 Right flexion-extension60.536.864.1
 Right radial-ulnar deviation57.938.556.8
Force (%MVF)
 Keyboard41.026.352.5
 Mouse63.246.264.1

Observed and predicted exposures based on data of 117 office workers, collected during computer work at their own workstation. Means (SD) and ranges of limits of exposure are given for observed physical exposures. Predictions are based on self-reported factors and software-recorded computer usage patterns. Abbreviation: SD = standard deviation.

a% Observed from total % predicted low, medium, or high.

Results

In the analyses of muscle activity and wrist posture, out of 120 participants, data of 117 participants were included. Seventy-two percent of the participants were female, with a mean (standard deviation) age of 41 (12) years, height of 174 (12) cm, weight of 73 (15) kg, and with a median of 5–10 years in a job with daily computer use. In the analyses of the wrist kinematics, data of 116 participants were included and in the analyses of forces on mouse and keyboard data of 114 participants were included. Data were excluded from the analyses because of technical failures and in one case because the participant had only 5 min of computer interaction time.

A: Full models; quality of predictions based on self-reported factors, software-recorded computer usage patterns, and additional worksite measurements of anthropometrics and workstation set-up

The prediction models for median wrist muscle activity showed R2 values of 0.40 and 0.41 for the right and left ECR, respectively. The predictive quality for wrist postures revealed R2 values ranging between 0.16 and 0.23, except for left wrist radial-ulnar deviation, which had an R2 of 0.34. The models predicting wrist velocity for the right hand showed higher R2 values (0.38 and 0.56 for flexion-extension and radial-ulnar deviation, respectively) compared to the models predicting wrist posture. The predictive quality of the wrist acceleration models was higher than the quality of the wrist velocity predictions, except for right radial-ulnar deviation, which was lower. Keyboard and mouse force prediction models had the highest predictive quality, with R2 values of 0.80 and 0.48, respectively. Keyboard force was predicted by only four predicting variables, of which two were additionally measured anthropometrical factors (i.e. body weight and hand length).

RMS errors for right and left ECR muscle activity were 2.4 %MVC and 1.8 %MVC, respectively. RMS errors for wrist postures ranged from 6.9 to 10.6 degrees, for wrist velocities from 3.2 to 6.8 degrees/s, and for wrist accelerations from 35.1 to 99.9 degrees/s2. The prediction models for keyboard force and mouse force had RMS errors of 0.6 and 0.4 %MVF, respectively. Relative RMS errors ranged from 5 to 24% for the 16 prediction models based on data collected through self-reported factors, software-recorded computer usage patterns, and additional worksite measurements of anthropometrics and workstation set-up.

Of each of the final models, beta, standard error, and P values from the full data set, as well as from the bootstrapping procedure are shown in Part 1 of the Supplementary Material (available at Annals of Work Exposures and Health online). These findings show reasonable consistency, with only small differences in predictive quality of the identified predicting variables.

B: Practical models; quality and classification agreement of predictions based on self-reported factors and software-recorded computer usage patterns

Compared to the full models, the predictive quality of all practical models decreased to some extent. Median muscle activity prediction models were not much influenced and revealed comparable quality for the right and left ECR, with the predicting variables still explaining 36% and 43% of the variance in right and left ECR muscle activity, respectively (Table 2). Regarding wrist postures and kinematics, the R2 values of wrist posture predictions and flexion-extension wrist velocity predictions remained comparable to the full models, the R2 values for wrist radial-ulnar velocity predictions and wrist acceleration predictions reduced. Without the additional worksite measurements of anthropometrics and workstation set-up as predicting variables in the models, keyboard and mouse force did not remain the best predictable outcomes. The predictive quality of keyboard force dropped considerably, i.e. from an R2 value of 0.80 to 0.05, and the quality of mouse force predictions dropped from an R2 value of 0.48 to 0.34.

RMS errors for right and left ECR muscle activity were 2.5 %MVC and 1.7 %MVC, respectively. RMS errors for wrist postures ranged from 6.9 to 10.8 degrees, for wrist velocities from 3.1 to 7.1 degrees/s, and for wrist accelerations from 37.8 to 111.0 degrees/s2. The prediction models for keyboard force and mouse force had RMS errors of 1.2 and 0.5 %MVF, respectively. Relative RMS errors ranged from 10 to 19% for the 16 prediction models based on data collected through self-reported factors and software-recorded computer usage patterns.

Comparing classification of the predicted and observed exposure outcomes in high, medium, and low groups, percentages of agreement varied largely across the different outcomes (Table 3). Range in both the predicted and observed exposures are shown in Table 4, while a typical example of a classification agreement is presented in Table 5. Percentages correctly classified predictions ranged from 33% to 69%. Overall, the highest percentages correctly classified cases were found in the low and high groups, and the lowest percentages in the medium group. In other words, most misclassification appeared in adjacent categories (i.e. low-medium and medium-high categories). The amount of misclassification between the low and high categories was on average 13.6%. The highest percentages of misclassification between the low and high categories were found for left wrist radial-ulnar deviation and for right flexion extension, revealing both 23.1% low-high/high-low misclassification, respectively.

Table 4.

Range in exposure in the low-, medium-, and high-exposure categories; for observed exposures as well as predicted exposures.

LowMediumHigh
Wrist muscle activity (%MVC)
 Left ECRObserved[0.7 to 3.2][3.3 to 5.1][5.2 to 11.9]
Predicted[1.1 to 3.9][4.0 to 5.0][5.0 to 10.8]
 Right ECRObserved[1.2 to 4.2][4.4 to 6.8][6.9 to 14.3]
Predicted[1.8 to 5.1][5.1 to 6.7][6.7 to 12.2]
Wrist posture (degrees)
 Left flexion-extensionObserved[−9.2 to 13.7][14.2 to 23.9][24.2 to 73.8]
Predicted[4.7 to 17.0][17.0 to 21.0][21.0 to 28.1]
 Left radial-ulnar deviationObserved[−48.0 to −2.6][−2.3 to 4.6][4.6 to 22.7]
Predicted[−13.1 to −1.6][−1.5 to 3.5][3.6 to 15.9]
 Right flexion-extensionObserved[0.0 to 22.4][22.8 to 31.1][31.2 to 91.3]
Predicted[16.0 to 25.0][25.0 to 28.6][28.9 to 36.6]
 Right radial-ulnar deviationObserved[−39.3 to 1.1][1.2 to 6.0][6.1 to 19.4]
Predicted[−6.3 to 2.0][2.2 to 4.8][4.8 to 9.7]
Wrist velocity (degrees/s)
 Left flexion-extensionObserved[0.0 to 19.0][19.1 to 23.1][23.2 to 38.4]
Predicted[15.4 to 20.3][20.3 to 22.8][23.0 to 27.7]
 Left radial-ulnar deviationObserved[0.0 to 11.2][11.2 to 14.0][14.0 to 19.1]
Predicted[10.2 to 12.1][12.3 to 12.3][14.2 to 16.1]
 Right flexion-extensionObserved[0.0 to 21.9][22.0 to 26.1][26.2 to 58.8]
Predicted[10.9 to 22.8][23.0 to 26.8][26.8 to 35.9]
 Right radial-ulnar deviationObserved[0.0 to 13.5][13.6 to 16.2][16.3 to 34.7]
Predicted[9.2 to 14.0][14.0 to 15.7][15.7 to 25.3]
Wrist acceleration (degrees/s2)
 Left flexion-extensionObserved[0.0 to 231.2][231.5 to 287.2][293.1 to 525.6]
Predicted[164.5 to 238.0][238.7 to 291.0][291.6 to 398.2]
 Left radial-ulnar deviationObserved[0.0 to 130.3][130.6 to 165.7][166.3 to 232.5]
Predicted[96.7 to 136.0][136.2 to 155.5][155.7 to 204.4]
 Right flexion-extensionObserved[0.0 to 283.9][289.9 to 360.7][366.8 to 926.7]
Predicted[136.7 to 304.4][305.0 to 388.0][390.1 to 549.8]
 Right radial-ulnar deviationObserved[0.0 to 173.2][174.0 to 204.7][205.4 to 539.2]
Predicted[81.7 to 177.2][177.9 to 209.8][210.0 to 369.6]
Force (%MVF)
 KeyboardObserved[0.0 to 0.0][0.0 to 0.1][0.1 to 12.0]
Predicted[−0.3 to 0.2][0.2 to 0.5][0.5 to 1.6]
 MouseObserved[−0.3 to 0.1][0.1 to 0.4][0.4 to 3.9]
Predicted[−0.4 to 0.2][0.2 to 0.5][0.5 to 1.3]
LowMediumHigh
Wrist muscle activity (%MVC)
 Left ECRObserved[0.7 to 3.2][3.3 to 5.1][5.2 to 11.9]
Predicted[1.1 to 3.9][4.0 to 5.0][5.0 to 10.8]
 Right ECRObserved[1.2 to 4.2][4.4 to 6.8][6.9 to 14.3]
Predicted[1.8 to 5.1][5.1 to 6.7][6.7 to 12.2]
Wrist posture (degrees)
 Left flexion-extensionObserved[−9.2 to 13.7][14.2 to 23.9][24.2 to 73.8]
Predicted[4.7 to 17.0][17.0 to 21.0][21.0 to 28.1]
 Left radial-ulnar deviationObserved[−48.0 to −2.6][−2.3 to 4.6][4.6 to 22.7]
Predicted[−13.1 to −1.6][−1.5 to 3.5][3.6 to 15.9]
 Right flexion-extensionObserved[0.0 to 22.4][22.8 to 31.1][31.2 to 91.3]
Predicted[16.0 to 25.0][25.0 to 28.6][28.9 to 36.6]
 Right radial-ulnar deviationObserved[−39.3 to 1.1][1.2 to 6.0][6.1 to 19.4]
Predicted[−6.3 to 2.0][2.2 to 4.8][4.8 to 9.7]
Wrist velocity (degrees/s)
 Left flexion-extensionObserved[0.0 to 19.0][19.1 to 23.1][23.2 to 38.4]
Predicted[15.4 to 20.3][20.3 to 22.8][23.0 to 27.7]
 Left radial-ulnar deviationObserved[0.0 to 11.2][11.2 to 14.0][14.0 to 19.1]
Predicted[10.2 to 12.1][12.3 to 12.3][14.2 to 16.1]
 Right flexion-extensionObserved[0.0 to 21.9][22.0 to 26.1][26.2 to 58.8]
Predicted[10.9 to 22.8][23.0 to 26.8][26.8 to 35.9]
 Right radial-ulnar deviationObserved[0.0 to 13.5][13.6 to 16.2][16.3 to 34.7]
Predicted[9.2 to 14.0][14.0 to 15.7][15.7 to 25.3]
Wrist acceleration (degrees/s2)
 Left flexion-extensionObserved[0.0 to 231.2][231.5 to 287.2][293.1 to 525.6]
Predicted[164.5 to 238.0][238.7 to 291.0][291.6 to 398.2]
 Left radial-ulnar deviationObserved[0.0 to 130.3][130.6 to 165.7][166.3 to 232.5]
Predicted[96.7 to 136.0][136.2 to 155.5][155.7 to 204.4]
 Right flexion-extensionObserved[0.0 to 283.9][289.9 to 360.7][366.8 to 926.7]
Predicted[136.7 to 304.4][305.0 to 388.0][390.1 to 549.8]
 Right radial-ulnar deviationObserved[0.0 to 173.2][174.0 to 204.7][205.4 to 539.2]
Predicted[81.7 to 177.2][177.9 to 209.8][210.0 to 369.6]
Force (%MVF)
 KeyboardObserved[0.0 to 0.0][0.0 to 0.1][0.1 to 12.0]
Predicted[−0.3 to 0.2][0.2 to 0.5][0.5 to 1.6]
 MouseObserved[−0.3 to 0.1][0.1 to 0.4][0.4 to 3.9]
Predicted[−0.4 to 0.2][0.2 to 0.5][0.5 to 1.3]
Table 4.

Range in exposure in the low-, medium-, and high-exposure categories; for observed exposures as well as predicted exposures.

LowMediumHigh
Wrist muscle activity (%MVC)
 Left ECRObserved[0.7 to 3.2][3.3 to 5.1][5.2 to 11.9]
Predicted[1.1 to 3.9][4.0 to 5.0][5.0 to 10.8]
 Right ECRObserved[1.2 to 4.2][4.4 to 6.8][6.9 to 14.3]
Predicted[1.8 to 5.1][5.1 to 6.7][6.7 to 12.2]
Wrist posture (degrees)
 Left flexion-extensionObserved[−9.2 to 13.7][14.2 to 23.9][24.2 to 73.8]
Predicted[4.7 to 17.0][17.0 to 21.0][21.0 to 28.1]
 Left radial-ulnar deviationObserved[−48.0 to −2.6][−2.3 to 4.6][4.6 to 22.7]
Predicted[−13.1 to −1.6][−1.5 to 3.5][3.6 to 15.9]
 Right flexion-extensionObserved[0.0 to 22.4][22.8 to 31.1][31.2 to 91.3]
Predicted[16.0 to 25.0][25.0 to 28.6][28.9 to 36.6]
 Right radial-ulnar deviationObserved[−39.3 to 1.1][1.2 to 6.0][6.1 to 19.4]
Predicted[−6.3 to 2.0][2.2 to 4.8][4.8 to 9.7]
Wrist velocity (degrees/s)
 Left flexion-extensionObserved[0.0 to 19.0][19.1 to 23.1][23.2 to 38.4]
Predicted[15.4 to 20.3][20.3 to 22.8][23.0 to 27.7]
 Left radial-ulnar deviationObserved[0.0 to 11.2][11.2 to 14.0][14.0 to 19.1]
Predicted[10.2 to 12.1][12.3 to 12.3][14.2 to 16.1]
 Right flexion-extensionObserved[0.0 to 21.9][22.0 to 26.1][26.2 to 58.8]
Predicted[10.9 to 22.8][23.0 to 26.8][26.8 to 35.9]
 Right radial-ulnar deviationObserved[0.0 to 13.5][13.6 to 16.2][16.3 to 34.7]
Predicted[9.2 to 14.0][14.0 to 15.7][15.7 to 25.3]
Wrist acceleration (degrees/s2)
 Left flexion-extensionObserved[0.0 to 231.2][231.5 to 287.2][293.1 to 525.6]
Predicted[164.5 to 238.0][238.7 to 291.0][291.6 to 398.2]
 Left radial-ulnar deviationObserved[0.0 to 130.3][130.6 to 165.7][166.3 to 232.5]
Predicted[96.7 to 136.0][136.2 to 155.5][155.7 to 204.4]
 Right flexion-extensionObserved[0.0 to 283.9][289.9 to 360.7][366.8 to 926.7]
Predicted[136.7 to 304.4][305.0 to 388.0][390.1 to 549.8]
 Right radial-ulnar deviationObserved[0.0 to 173.2][174.0 to 204.7][205.4 to 539.2]
Predicted[81.7 to 177.2][177.9 to 209.8][210.0 to 369.6]
Force (%MVF)
 KeyboardObserved[0.0 to 0.0][0.0 to 0.1][0.1 to 12.0]
Predicted[−0.3 to 0.2][0.2 to 0.5][0.5 to 1.6]
 MouseObserved[−0.3 to 0.1][0.1 to 0.4][0.4 to 3.9]
Predicted[−0.4 to 0.2][0.2 to 0.5][0.5 to 1.3]
LowMediumHigh
Wrist muscle activity (%MVC)
 Left ECRObserved[0.7 to 3.2][3.3 to 5.1][5.2 to 11.9]
Predicted[1.1 to 3.9][4.0 to 5.0][5.0 to 10.8]
 Right ECRObserved[1.2 to 4.2][4.4 to 6.8][6.9 to 14.3]
Predicted[1.8 to 5.1][5.1 to 6.7][6.7 to 12.2]
Wrist posture (degrees)
 Left flexion-extensionObserved[−9.2 to 13.7][14.2 to 23.9][24.2 to 73.8]
Predicted[4.7 to 17.0][17.0 to 21.0][21.0 to 28.1]
 Left radial-ulnar deviationObserved[−48.0 to −2.6][−2.3 to 4.6][4.6 to 22.7]
Predicted[−13.1 to −1.6][−1.5 to 3.5][3.6 to 15.9]
 Right flexion-extensionObserved[0.0 to 22.4][22.8 to 31.1][31.2 to 91.3]
Predicted[16.0 to 25.0][25.0 to 28.6][28.9 to 36.6]
 Right radial-ulnar deviationObserved[−39.3 to 1.1][1.2 to 6.0][6.1 to 19.4]
Predicted[−6.3 to 2.0][2.2 to 4.8][4.8 to 9.7]
Wrist velocity (degrees/s)
 Left flexion-extensionObserved[0.0 to 19.0][19.1 to 23.1][23.2 to 38.4]
Predicted[15.4 to 20.3][20.3 to 22.8][23.0 to 27.7]
 Left radial-ulnar deviationObserved[0.0 to 11.2][11.2 to 14.0][14.0 to 19.1]
Predicted[10.2 to 12.1][12.3 to 12.3][14.2 to 16.1]
 Right flexion-extensionObserved[0.0 to 21.9][22.0 to 26.1][26.2 to 58.8]
Predicted[10.9 to 22.8][23.0 to 26.8][26.8 to 35.9]
 Right radial-ulnar deviationObserved[0.0 to 13.5][13.6 to 16.2][16.3 to 34.7]
Predicted[9.2 to 14.0][14.0 to 15.7][15.7 to 25.3]
Wrist acceleration (degrees/s2)
 Left flexion-extensionObserved[0.0 to 231.2][231.5 to 287.2][293.1 to 525.6]
Predicted[164.5 to 238.0][238.7 to 291.0][291.6 to 398.2]
 Left radial-ulnar deviationObserved[0.0 to 130.3][130.6 to 165.7][166.3 to 232.5]
Predicted[96.7 to 136.0][136.2 to 155.5][155.7 to 204.4]
 Right flexion-extensionObserved[0.0 to 283.9][289.9 to 360.7][366.8 to 926.7]
Predicted[136.7 to 304.4][305.0 to 388.0][390.1 to 549.8]
 Right radial-ulnar deviationObserved[0.0 to 173.2][174.0 to 204.7][205.4 to 539.2]
Predicted[81.7 to 177.2][177.9 to 209.8][210.0 to 369.6]
Force (%MVF)
 KeyboardObserved[0.0 to 0.0][0.0 to 0.1][0.1 to 12.0]
Predicted[−0.3 to 0.2][0.2 to 0.5][0.5 to 1.6]
 MouseObserved[−0.3 to 0.1][0.1 to 0.4][0.4 to 3.9]
Predicted[−0.4 to 0.2][0.2 to 0.5][0.5 to 1.3]
Table 5.

Typical example of a cross tabulation, showing percentage of agreement between observed and predicted exposures, using data of 117 office workers collected during computer work at their own workstation.

Observed exposureaTotal
LowMediumHigh
Predicted exposureaLowPercentage within Group60.5%30.8%10.5%33.9%
MediumPercentage within Group28.9%38.5%34.2%33.9%
HighPercentage within Group10.5%30.8%55.3%32.2%
TotalPercentage within Group100.0%100.0%100.0%100.0%
Observed exposureaTotal
LowMediumHigh
Predicted exposureaLowPercentage within Group60.5%30.8%10.5%33.9%
MediumPercentage within Group28.9%38.5%34.2%33.9%
HighPercentage within Group10.5%30.8%55.3%32.2%
TotalPercentage within Group100.0%100.0%100.0%100.0%

aLeft wrist flexion-extension acceleration.

Table 5.

Typical example of a cross tabulation, showing percentage of agreement between observed and predicted exposures, using data of 117 office workers collected during computer work at their own workstation.

Observed exposureaTotal
LowMediumHigh
Predicted exposureaLowPercentage within Group60.5%30.8%10.5%33.9%
MediumPercentage within Group28.9%38.5%34.2%33.9%
HighPercentage within Group10.5%30.8%55.3%32.2%
TotalPercentage within Group100.0%100.0%100.0%100.0%
Observed exposureaTotal
LowMediumHigh
Predicted exposureaLowPercentage within Group60.5%30.8%10.5%33.9%
MediumPercentage within Group28.9%38.5%34.2%33.9%
HighPercentage within Group10.5%30.8%55.3%32.2%
TotalPercentage within Group100.0%100.0%100.0%100.0%

aLeft wrist flexion-extension acceleration.

The bootstrapping procedure showed internal consistency of the results, with comparable betas, standard errors, and P values of the final practical models and the bootstrapping procedure (found in Part 2 of the Supplementary Material, available at Annals of Work Exposures and Health online).

Discussion

Summary of main results

By comparison with direct measurements in real-life work-settings, the aim of this study was to develop and evaluate prediction models of arm-wrist-hand exposures during computer use from self-reported factors, software-recorded computer usage patterns, and additional worksite measurements of anthropometrics and workstation set-up. In addition, we aimed to evaluate the differences in predictive quality of models based on self-reported factors and software-recorded computer usage patterns alone (practical models). The practical models, which do not require direct researcher observation, did not perform as well as the full models based on the full set of predicting variables in terms of the R2 values, especially not for wrist velocity, wrist acceleration, and force predictions, but did show overall comparable RMS errors and relative RMS errors. When observed and predicted physical exposures of the practical models were classified into low, medium, and high, classification agreement revealed highest percentage correctly predicted exposures in the low and high categories, with percentages of agreement above what would be expected by chance alone, i.e. above 33.3%. This means that even though the predictive quality of the practical models was in general not large, especially the high and low groups could be correctly classified.

Given the results of the present study, the usability of the reported prediction models as a tool for arm-wrist-hand physical exposure assessment remains uncertain, especially since currently no evaluation standards are available. Based on R2 values that were mainly below 0.20, Svendsen and colleagues (2005) concluded that their task-based exposure predictions were unsuccessful. The R2 values of our prediction models ranged from 0.16 to 0.80 when possible predicting variables from additional measurements of anthropometrics and workstation set-up measurements were included in the selection procedure of the prediction model development, and R2 values ranged from 0.05 to 0.43 without these additional measurements. However, the interquartile ranges were not that different between the full and the practical models, indicating that only for some physical exposures the full models performed substantially better; i.e. for keyboard force, right radial-ulnar deviation, and for right flexion-extension acceleration. The predictive quality of the prediction models in the present paper was better than the models from the above mentioned study, but worse than the prediction models of van der Beek and colleagues (2012), who reported R2 values between 0.77 and 0.92 and concluded that using these models as assessment tool were promising. Relative RMS errors of 11% have been suggested to indicate sufficient validity of exposure assessments (Chen et al., 2004). We found comparable relative RMS errors in our study for many exposure parameters and even higher values for some others (Tables 1 and 2).

Furthermore, examination of the percentages correctly classified low, medium, and high exposures, which might give valuable information regarding the usability of these models in analyses with categorized variables, revealed only satisfactory percentages of correctly classified predicted exposures in the low- and high-exposure categories. Most misclassification was found between low and medium and between medium and high exposures. Hence, large contrasts within a study population, which are important in testing the relation of arm-wrist-hand exposures and symptom development, could be feasible based on differences between low- and high-risk groups. Yet, for the majority of the studied physical exposures seem unlikely that dose-response relationships can be studied by the use of prediction models in epidemiological studies.

The additionally measured anthropometrical variables were included in 12 of the 16 models and workstation set-up variables were included in 9 of the 16 models. Removal of these variables had the largest effect on the quality of keyboard and mouse force predictions, and muscle activity predictions were affected the least. The importance of anthropometry in relation to computer use exposures has been indicated by Won and colleagues (2009), who studied gender differences in exposure during computer use.

When comparing the quality of the arm-wrist-hand exposure predictions evaluated in the present study to the quality of neck-shoulder exposure predictions using models that were developed following the same methods (Bruno Garza et al., 2014), neck-shoulder muscle activity and shoulder, neck, and torso postures can be better predicted than forearm extensor muscle activity and wrist postures, which was contrary to what we expected. We expected that the predictive quality of arm-wrist-hand exposure models would be better than neck-shoulder exposure prediction models because arm-wrist-hand exposures were expected to be more task-related and characteristics of computer use could be included as predictor variables in the present study. It might be that the constraints of computer work reduce variance in task performance and thereby in physical exposure of the arms, wrists, and hands between workers. Furthermore, it was striking that individual factors, especially anthropometry, were more important predicting variables in arm-wrist-hand predictions than in neck-shoulder predictions, and psychosocial factors had notably less predictive value in arm-wrist-hand predictions compared to neck-shoulder predictions. These results might also argue for different approaches of future interventions aiming to reduce arm-wrist-hand and neck-shoulder physical exposures during computer use.

We expected that the variance in arm-wrist-hand physical exposures among office workers would partly be explained by task (i.e. the distribution of keyboard, mouse, and idle time across a work day). However, even though in 10 of the 16 prediction models at least one of the variables % keyboard use, % mouse use, or % idle time were included, the R2 values were still quite low. It is possible that forearm physical exposures during computer work are not to a large extent explained by the variation in computer task, which is in line with findings of Mathiassen and colleagues (2005), and argues for addressing “total computer use” (i.e. including keyboard, mouse, and idle time) in future exposure assessment studies.

Predictive quality varied largely between the models; where some wrist-arm-hand exposures could sufficiently be predicted, for other physical exposures the predictive quality was poor. In future studies, predictions could be improved when the sources of the unexplained variances are understood. In the present study, a wide set of predicting variables was used, covering many different categories of individual and occupational factors usually measured in etiological and epidemiological studies on physical exposures and neck- and upper-extremity symptoms (IJmker et al., 2006). Nevertheless, it is possible that important variables have been overlooked. Differences in predictive quality between physical exposures cannot be fully explained by the number of variables in the models. In general, the models with most predictive quality had the highest number of predictors, but e.g. keyboard force, the physical exposure measure with the highest explained variance (80%) had only four predictors in the full model. In the practical models, without the two physical measures (measured body weight and hand length), the explained variance of keyboard dropped to 5%, In the model for left radial-ulnar velocity, two predicting variables were identified, explaining only 8% of the variance. It is likely that important predicting variables are missed here. Moreover, it may be that workers adopt different postural strategies during the different aspects of computer use that are not captured by the content of the task and the workstation set-up. As such, a lack of variation in our data may also clarify the relatively poor explained variance in some of the models. Future studies could further explore additional metrics that could be measured at the work site in order to further improve predictive quality of the models or explore the use of different models for mouse use, keyboard use, and idle time.

Strengths and limitations

This is the first study exploring arm-wrist-hand physical exposure predictions during computer use as a possible future exposure assessment tool that is less costly and time consuming than direct measurements. For the development of the prediction models, we collected an abundance of data: 98 possible predicting variables and many different arm-wrist-hand exposures. For the latter, we used reliable measurement systems, which continuously collected data for ~2 h, among a large number of office workers performing their normal computer work. The results of this study provide useful information on the predictive quality of prediction models for arm-wrist-hand exposures that can be reached based on a wide range of predicting variables across different categories. This information can be used as a basis to further develop these prediction models, especially those with relatively large predictive quality. In future studies, also the use of common sets of predictors could be further explored to further reduce the number of predicting variables that need to be collected (make the models even more practical), while at the same time taking into account the effect on the predictive quality of the models. The bootstrapping procedure, as shown in Parts 1 and 2 of the Supplementary Material (available at Annals of Work Exposures and Health online), shows reasonable consistency for the identified factors in the final models, suggesting internal validity of the presented findings.

Limitations must be taken into consideration when interpreting the results of this study. First, the results of this study are purely empirical. Since we used a backward selection method predicting variables may have been included in a model by chance, there was a risk of overfitting or included variables may only have fitted the present study population’s data (Harrell, 2001). We intended to limit such possible error by performing a pre-selection, based on the single associations between predictor variables and an outcome. All 98 variables were theoretically related to physical exposures or upper extremity symptoms and using a multiple step approach to reduce the number of predicting variables before conducting a multivariate model. Bootstrapping showed that despite the multiple testing the results were quite robust; however, we did not test the developed prediction models in an external data set. When the presented models would be externally validated, it is likely that the R2 values drop (Harrell, 2001). Furthermore, we would like to note that this study focused on the intensity of exposure only. With regard to musculoskeletal symptoms, duration, and frequency of exposure are other important factors to consider.

Conclusions

As expected, the full prediction models based on self-reported factors, software-recorded computer usage patterns, and additional worksite measurements of anthropometrics and workstation set-up, showed in general a better predictive quality as compared to the practical models based on self-reported factors and software-recorded computer usage patterns only, but results vary largely across different arm-wrist-hand exposure parameters. Future exploration of the relation between predicted physical exposure and symptoms is therefore only recommended for physical exposures that can be reasonably well predicted.

Supplementary Data

Supplementary data are available at Annals of Work Exposures and Health online.

Authors’ Contributions

M.A.H.—Study design, data analyses, interpretation of the data, writing of the manuscript. B.H.W.E.—Study design, data acquisition, data processing, data analyses, interpretation of the data, writing of the manuscript. J.L.B.G.—Study design, data processing, interpretation of the data, revision of the manuscript. P.C.—Data analysis, interpretation of the data, revision of the manuscript. B.M.B.—Study design, interpretation of the data, revision of the manuscript. P.W.J.—Study design, data acquisition, interpretation of the data, revision of the manuscript. J.H.D.—Study design, interpretation of the data, revision of the manuscript. A.J.B.—Study design, interpretation of the data, revision of the manuscript. J.T.D.—Study design, data acquisition, data processing, interpretation of the data, revision of the manuscript.

Competing Interests

The authors declare that they have no competing interests.

Acknowledgements

This study was funded in part by the CDC/NIOSH grant R01-0H-08781 (PI: Dennerlein). The authors would like to thank Sachin Raina and Patrik Rynell for their contributions to the data collection, and analysis for this study.

References

Asundi
K
,
Johnson
PW
,
Dennerlein
JT
. (
2009
)
Inertia artefacts and their effect on the parameterisation of keyboard reaction forces
.
Ergonomics
;
52
:
1259
64
.

Balogh
I
,
Ørbaek
P
,
Ohlsson
K
et al. ;
Malmö Shoulder/Neck Study Group
. (
2004
)
Self-assessed and directly measured occupational physical activities–influence of musculoskeletal complaints, age and gender
.
Appl Ergon
;
35
:
49
56
.

Basmajian
JV
. (
1989
)
Biofeedback; Principles and practice for clinicians
.
Baltimore, MD
:
Willams & Wilkins
.

Blatter
BM
,
Houtman
I
,
Van den Bossche
S
et al. (
2005
)
Health damage and costs of RSI and psychosocial work load in The Netherlands
. Report on demand of
The Dutch Ministry of Social Affairs and Employment
.

Bleecker
ML
,
Barnes
SK
. (
2012
)
Exposure to keyboard/mouse use = keystrokes + mouse clicks + POSTURE: a missing variable that cannot be overstated
.
Occup Environ Med
;
69
:
301
2
.

Bruno Garza
JL
,
Eijckelhof
BH
,
Johnson
PW
et al. (
2012
)
Observed differences in upper extremity forces, muscle efforts, postures, velocities and accelerations across computer activities in a field study of office workers
.
Ergonomics
;
55
:
670
81
.

Bruno Garza
JL
,
Eijckelhof
BH
,
Huysmans
MA
et al. (
2014
)
Prediction of trapezius muscle activity and shoulder, head, neck, and torso postures during computer use: results of a field study
.
BMC Musculoskelet Disord
;
15
:
292
.

Chang
CH
,
Johnson
PW
,
Dennerlein
JT
. (
2008
)
A wide range of activity duration cutoffs provided unbiased estimates of exposure to computer use
.
J Occup Environ Hyg
;
5
:
790
6
.

Chen
JC
,
Chang
WR
,
Shih
TS
et al. (
2004
)
Using exposure prediction rules for exposure assessment: an example on whole-body vibration in taxi drivers
.
Epidemiology
;
15
:
293
9
.

Cohen
S
,
Kamarck
T
,
Mermelstein
R
. (
1983
)
A global measure of perceived stress
.
J Health Soc Behav
;
24
:
385
96
.

Dennerlein
JT
,
Johnson
PW
. (
2006
)
Different computer tasks affect the exposure of the upper extremity to biomechanical risk factors
.
Ergonomics
;
49
:
45
61
.

Eltayeb
S
,
Staal
JB
,
Hassan
A
et al. (
2009
)
Work related risk factors for neck, shoulder and arms complaints: a cohort study among Dutch computer office workers
.
J Occup Rehabil
;
19
:
315
22
.

Gerr
F
,
Marcus
M
,
Monteilh
C
. (
2004
)
Epidemiology of musculoskeletal disorders among computer users: lesson learned from the role of posture and keyboard use
.
J Electromyogr Kinesiol
;
14
:
25
31
.

Gerr
F
,
Monteilh
CP
,
Marcus
M
. (
2006
)
Keyboard use and musculoskeletal outcomes among computer users
.
J Occup Rehabil
;
16
:
265
77
.

Hagberg
M
,
Vilhemsson
R
,
Tornqvist
EW
et al. (
2007
)
Incidence of self-reported reduced productivity owing to musculoskeletal symptoms: association with workplace and individual factors among computer users
.
Ergonomics
;
50
:
1820
34
.

Hansson
GA
,
Balogh
I
,
Byström
JU
et al. ;
Malmö Shoulder-Neck Study Group
. (
2001
)
Questionnaire versus direct technical measurements in assessing postures and movements of the head, upper back, arms and hands
.
Scand J Work Environ Health
;
27
:
30
40
.

Harrell
WA
,
Spaulding
LM
. (
2001
)
Social psychological models of choice behavior and drivers’ left turns
.
J Soc Psychol
;
141
:
714
22
.

Heiden
M
,
Mathiassen
SE
,
Garza
J
et al. (
2016
)
A Comparison of two strategies for building an exposure prediction model
.
Ann Occup Hyg
;
60
:
74
89
.

Hwang
YH
,
Chen
YT
,
Yeh
JY
et al. (
2010
)
Effects of passive computer use time and non-computer work time on the performance of electronic activity monitoring
.
Ergonomics
;
53
:
1254
62
.

IJmker
S
,
Blatter
BM
,
van der Beek
AJ
et al. (
2006
)
Prospective research on musculoskeletal disorders in office workers (PROMO): study protocol
.
BMC Musculoskelet Disord
;
7
:
55
.

Johnson
PW
,
Hagberg
M
,
Hjelm
EW
et al. (
2000
)
Measuring and characterizing force exposures during computer mouse use
.
Scand J Work Environ Health
;
26
:
398
405
.

Karasek
R
,
Brisson
C
,
Kawakami
N
et al. (
1998
)
The Job Content Questionnaire (JCQ): an instrument for internationally comparative assessments of psychosocial job characteristics
.
J Occup Health Psychol
;
3
:
322
55
.

Marcus
M
,
Gerr
F
,
Monteilh
C
et al. (
2002
)
A prospective study of computer users: II. Postural risk factors for musculoskeletal symptoms and disorders
.
Am J Ind Med
;
41
:
236
49
.

Mathiassen
SE
,
Nordander
C
,
Svendsen
SW
et al. (
2005
)
Task-based estimation of mechanical job exposure in occupational groups
.
Scand J Work Environ Health
;
31
:
138
51
.

Punnett
L
,
Wegman
DH
. (
2004
)
Work-related musculoskeletal disorders: the epidemiologic evidence and the debate
.
J Electromyogr Kinesiol
;
14
:
13
23
.

Schreurs
KM
,
de Ridder
DT
. (
1997
)
Integration of coping and social support perspectives: implications for the study of adaptation to chronic diseases
.
Clin Psychol Rev
;
17
:
89
112
.

Siegrist
J
. (
1996
)
Adverse health effects of high-effort/low-reward conditions
.
J Occup Health Psychol
;
1
:
27
41
.

Siegrist
J
,
Starke
D
,
Chandola
T
et al. (
2004
)
The measurement of effort-reward imbalance at work: European comparisons
.
Soc Sci Med
;
58
:
1483
99
.

Sluiter
JK
,
van der Beek
AJ
,
Frings-Dresen
MH
. (
1999
)
The influence of work characteristics on the need for recovery and experienced health: a study on coach drivers
.
Ergonomics
;
42
:
573
83
.

Svendsen
SW
,
Mathiassen
SE
,
Bonde
JP
. (
2005
)
Task based exposure assessment in ergonomic epidemiology: a study of upper arm elevation in the jobs of machinists, car mechanics, and house painters
.
Occup Environ Med
;
62
:
18
27
.

Trask
C
,
Teschke
K
,
Village
J
et al. (
2007
)
Measuring low back injury risk factors in challenging work environments: an evaluation of cost and feasibility
.
Am J Ind Med
;
50
:
687
96
.

Trask
C
,
Mathiassen
SE
,
Wahlström
J
et al. (
2014
)
Cost-efficient assessment of biomechanical exposure in occupational groups, exemplified by posture observation and inclinometry
.
Scand J Work Environ Health
;
40
:
252
65
.

van den Heuvel
SG
,
Ijmker
S
,
Blatter
BM
et al. (
2007
)
Loss of productivity due to neck/shoulder symptoms and hand/arm symptoms: results from the PROMO-study
.
J Occup Rehabil
;
17
:
370
82
.

van der Beek
AJ
. (
2012
)
World at work: truck drivers
.
Occup Environ Med
;
69
:
291
5
.

van Veldhoven
M
,
Broersen
S
. (
2003
)
Measurement quality and validity of the “need for recovery scale”
.
Occup Environ Med
;
60
(
Suppl. 1
):
i3
9
.

Visser
B
,
van Dieën
JH
. (
2006
)
Pathophysiology of upper extremity muscle disorders
.
J Electromyogr Kinesiol
;
16
:
1
16
.

Winkel
J
,
Mathiassen
SE
. (
1994
)
Assessment of physical work load in epidemiologic studies: concepts, issues and operational considerations
.
Ergonomics
;
37
:
979
88
.

Won
EJ
,
Johnson
PW
,
Punnett
L
et al. (
2009
)
Upper extremity biomechanics in computer tasks differ by gender
.
J Electromyogr Kinesiol
;
19
:
428
36
.

Yeh
JY
,
Liang
HW
,
Hwang
YH
. (
2009
)
The effect of idle time thresholds on computer use time estimations by electronic monitoring
.
Ergonomics
;
52
:
872
81
.

Supplementary data