Background: Postoperative liver failure is a serious complication after major hepatectomy, and perioperative prediction of its incidence using current technology is still very difficult. Near-infrared (NIR) fluorescence imaging allows quantitative assessment of the fluorescent signal from indocyanine green (ICG) in regions of interest on the liver surface. This method might offer a new promising modality for evaluating regional liver reserve. However, data are lacking regarding the relationship between liver function and fluorescent signals on the liver surface after intravenous ICG injection. This study was conducted to obtain the data necessary to apply NIR fluorescence imaging as a modality for measuring liver function. Materials and Methods: This study included 16 patients who underwent open hepatopancreatobiliary surgery between March 2011 and March 2012. After laparotomy, ICG was injected intravenously at 2.5 mg/L of liver volume, then the fluorescence intensity (FI) and signal-to-background ratio (SBR) in the lateral segment of the liver were assessed for 15 min. Intraoperative blood samples were also obtained to measure the plasma clearance rate of ICG (ICGK). Correlations between ICGK, liver volume, and SBR, as well as between ICGK, liver volume, and rate of change of FI were analyzed. Results: The experimental procedure was performed in all 16 patients. The FI of the liver increased rapidly after ICG injection, then became more gradual, reaching a near-plateau after 15 min. A significant correlation was seen between ICGK and the rate of change of FI up to 15 min (|rS| = 0.5725, p < 0.05). Conclusion: This is the first report to show a relationship between liver function and fluorescent signals on the liver surface after intravenous ICG injection. Intraoperative NIR fluorescence imaging with ICG may be useful as a new method for assessing liver function.

1.
Hirano S, Kondo S, Tanaka E, Shichinohe T, Tsuchikawa T, Kato K, et al: Outcome of surgical treatment of hilar cholangiocarcinoma: a special reference to postoperative morbidity and mortality. J Hepatobiliary Pancreat Sci 2010;17:455-462.
2.
Yokoyama Y, Nishio H, Ebata T, Igami T, Sugawara G, Nagino M: Value of indocyanine green clearance of the future liver remnant in predicting outcome after resection for biliary cancer. Br J Surg 2010;97:1260-1268.
3.
Hemming AW, Scudamore CH, Shackleton CR, Pudek M, Erb SR: Indocyanine green clearance as a predictor of successful hepatic resection in cirrhotic patients. Am J Surg 1992;163:515-518.
4.
Fazakas J, Mándli T, Ther G, Arkossy M, Pap S, Füle B, et al: Evaluation of liver function for hepatic resection. Transplant Proc 2006;38:798-800.
5.
Mitsumori A, Nagaya I, Kimoto S, Akaki S, Togami I, Takeda Y, et al: Preoperative evaluation of hepatic functional reserve following hepatectomy by technetium-99m galactosyl human serum albumin liver scintigraphy and computed tomography. Eur J Nucl Med 1998;25:1377-1382.
6.
Kubo S, Shiomi S, Tanaka H, Shuto T, Takemura S, Mikami S, et al: Evaluation of the effect of portal vein embolization on liver function by 99mTc-galactosyl human serum albumin scintigraphy. J Surg Res 2002;107:113-118.
7.
Miyagawa S, Makuuchi M, Kawasaki S, Kakazu T: Criteria for safe hepatic resection. Am J Surg 1995;169:589-594.
8.
Troyan SL, Kianzad V, Gibbs-Strauss SL, Gioux S, Matsui A, Oketokoun R, et al: The FLARE intraoperative near-infrared fluorescence imaging system: a first-in-human clinical trial in breast cancer sentinel lymph node mapping. Ann Surg Oncol 2009;16:2943-2952.
9.
Matsui A, Winer JH, Laurence RG, Frangioni JV: Predicting the survival of experimental ischaemic small bowel using intraoperative near-infrared fluorescence angiography. Br J Surg 2011;98:1725-1734.
10.
Ashitate Y, Stockdale A, Choi HS, Laurence RG, Frangioni JV: Real-time simultaneous near-infrared fluorescence imaging of bile duct and arterial anatomy. J Surg Res 2012;176:7-13.
11.
van der Vorst JR, Schaafsma BE, Hutteman M, Verbeek FP, Liefers GJ, Hartgrink HH, et al: Near-infrared fluorescence-guided resection of colorectal liver metastases. Cancer 2013;119:3411-3418.
12.
Tummers QR, Verbeek FP, Prevoo HA, Braat AE, Baeten CI, Frangioni JV, et al: First experience on laparoscopic near-infrared fluorescence imaging of hepatic uveal melanoma metastases using indocyanine green. Surg Innov 2015;22:20-25.
13.
Hutteman M, Mieog JS, van der Vorst JR, Liefers GJ, Putter H, Löwik CW, et al: Randomized, double-blind comparison of indocyanine green with or without albumin premixing for near-infrared fluorescence imaging of sentinel lymph nodes in breast cancer patients. Breast Cancer Res Treat 2011;127:163-170.
14.
Mieog JS, Troyan SL, Hutteman M, Donohoe KJ, van der Vorst JR, Stockdale A, et al: Toward optimization of imaging system and lymphatic tracer for near-infrared fluorescent sentinel lymph node mapping in breast cancer. Ann Surg Oncol 2011;18:2483-2491.
15.
Schaafsma BE, van der Vorst JR, Gaarenstroom KN, Peters AA, Verbeek FP, de Kroon CD, et al: Randomized comparison of near-infrared fluorescence lymphatic tracers for sentinel lymph node mapping of cervical cancer. Gynecol Oncol 2012;127:126-130.
16.
Verbeek FP, van der Vorst JR, Schaafsma BE, Swijnenburg RJ, Gaarenstroom KN, Elzevier HW, et al: Intraoperative near infrared fluorescence guided identification of the ureters using low dose methylene blue: a first in human experience. J Urol 2013;190:574-579.
17.
Verbeek FP, Schaafsma BE, Tummers QR, van der Vorst JR, van der Made WJ, Baeten CI, et al: Optimization of near-infrared fluorescence cholangiography for open and laparoscopic surgery. Surg Endosc 2014;28:1076-1082.
18.
Ohnishi S, Lomnes SJ, Laurence RG, Gogbashian A, Mariani G, Frangioni JV: Organic alternatives to quantum dots for intraoperative near-infrared fluorescent sentinel lymph node mapping. Mol Imaging 2005;4:172-181.
19.
Parungo CP, Ohnishi S, Kim SW, Kim S, Laurence RG, Soltesz EG, et al: Intraoperative identification of esophageal sentinel lymph nodes with near-infrared fluorescence imaging. J Thorac Cardiovasc Surg 2005;129:844-850.
20.
Nagino M, Kamiya J, Nishio H, Ebata T, Arai T, Nimura Y: Two hundred forty consecutive portal vein embolizations before extended hepatectomy for biliary cancer: surgical outcome and long-term follow-up. Ann Surg 2006;243:364-372.
21.
Kwon AH, Ha-Kawa SK, Uetsuji S, Kamiyama Y, Tanaka Y: Use of technetium 99m diethylenetriamine-pentaacetic acid-galactosyl-human serum albumin liver scintigraphy in the evaluation of preoperative and postoperative hepatic functional reserve for hepatectomy. Surgery 1995;117:429-434.
22.
Inoue Y, Machida K, Honda N, Mamiya T, Takahashi T, Kamano T, et al: Impaired hepatic function in segmental biliary obstruction demonstrated with a receptor-binding radiotracer. Ann Nucl Med 1994;8:209-212.
23.
Verloh N, Haimerl M, Zeman F, Schlabeck M, Barreiros A, Loss M, et al: Assessing liver function by liver enhancement during the hepatobiliary phase with Gd-EOB-DTPA-enhanced MRI at 3 tesla. Eur Radiol 2014;24:1013-1019.
24.
Utsunomiya T, Shimada M, Hanaoka J, Kanamoto M, Ikemoto T, Morine Y, et al: Possible utility of MRI using Gd-EOB-DTPA for estimating liver functional reserve. J Gastroenterol 2012;47:470-476.
25.
Bae KE, Kim SY, Lee SS, Kim KW, Won HJ, Shin YM, et al: Assessment of hepatic function with Gd-EOB-DTPA-enhanced hepatic MRI. Dig Dis 2012;30:617-622.
26.
Nanashima A, Tobinaga S, Abo T, Sumida Y, Araki M, Hayashi H, et al: Relationship of hepatic functional parameters with changes of functional liver volume using technetium-99m galactosyl serum albumin scintigraphy in patients undergoing preoperative portal vein embolization: a follow-up report. J Surg Res 2010;164:e235-e242.
27.
Venugopal V, Park M, Ashitate Y, Neacsu F, Kettenring F, Frangioni JV, et al: Design and characterization of an optimized simultaneous color and near-infrared fluorescence rigid endoscopic imaging system. J Biomed Opt 2013;18:126018.
Copyright / Drug Dosage / Disclaimer
Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher.
Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug.
Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.
You do not currently have access to this content.