Skip to main content
Erschienen in: BMC Cancer 1/2015

Open Access 01.12.2015 | Research article

Multimodality imaging with CT, MR and FDG-PET for radiotherapy target volume delineation in oropharyngeal squamous cell carcinoma

verfasst von: David Bird, Andrew F. Scarsbrook, Jonathan Sykes, Satiavani Ramasamy, Manil Subesinghe, Brendan Carey, Daniel J. Wilson, Neil Roberts, Gary McDermott, Ebru Karakaya, Evrim Bayman, Mehmet Sen, Richard Speight, Robin J.D. Prestwich

Erschienen in: BMC Cancer | Ausgabe 1/2015

Abstract

Background

This study aimed to quantify the variation in oropharyngeal squamous cell carcinoma gross tumour volume (GTV) delineation between CT, MR and FDG PET-CT imaging.

Methods

A prospective, single centre, pilot study was undertaken where 11 patients with locally advanced oropharyngeal cancers (2 tonsil, 9 base of tongue primaries) underwent pre-treatment, contrast enhanced, FDG PET-CT and MR imaging, all performed in a radiotherapy treatment mask. CT, MR and CT-MR GTVs were contoured by 5 clinicians (2 radiologists and 3 radiation oncologists). A semi-automated segmentation algorithm was used to contour PET GTVs. Volume and positional analyses were undertaken, accounting for inter-observer variation, using linear mixed effects models and contour comparison metrics respectively.

Results

Significant differences in mean GTV volume were found between CT (11.9 cm3) and CT-MR (14.1 cm3), p < 0.006, CT-MR and PET (9.5 cm3), p < 0.0009, and MR (12.7 cm3) and PET, p < 0.016. Substantial differences in GTV position were found between all modalities with the exception of CT-MR and MR GTVs. A mean of 64 %, 74 % and 77 % of the PET GTVs were included within the CT, MR and CT-MR GTVs respectively. A mean of 57 % of the MR GTVs were included within the CT GTV; conversely a mean of 63 % of the CT GTVs were included within the MR GTV. CT inter-observer variability was found to be significantly higher in terms of position and/or volume than both MR and CT-MR (p < 0.05). Significant differences in GTV volume were found between GTV volumes delineated by radiologists (9.7 cm3) and oncologists (14.6 cm3) for all modalities (p = 0.001).

Conclusions

The use of different imaging modalities produced significantly different GTVs, with no single imaging technique encompassing all potential GTV regions. The use of MR reduced inter-observer variability. These data suggest delineation based on multimodality imaging has the potential to improve accuracy of GTV definition.

Trial registration

ISRCTN Registry: ISRCTN34165059. Registered 2nd February 2015.
Hinweise
Richard Speight and Robin J.D. Prestwich are joint senior authorship

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

DB: Image analysis, data analysis, manuscript preparation and editing. AS: Study design, image analysis, manuscript editing. JS: Study design, data analysis, manuscript editing. SR: Contouring, manuscript editing. MS: Contouring, manuscript editing. BC: Contouring, manuscript editing. DW: Data analysis, manuscript editing. NR: Study design, manuscript editing. GM: Phantom measurements, image analysis, manuscript editing. EK: Contouring, manuscript editing. EB: Contouring, manuscript editing. MS: Study design, manuscript editing. RS: Data analysis, image registration, manuscript preparation and editing. RP: Study design, study co-ordination/recruitment, data analysis, manuscript preparation and editing. All authors read and approved the final manuscript.
Abkürzungen
ARSAC
administration of radioactive substances advisory committee
CGD
centre of gravity distance
CI
conformity index
CT
computed tomography
CTV
clinical target volume
FDG
2-deoxy-2-[18F]-fluoro-D-glucose
GTV
gross tumour volume
IMRT
intensity modulated radiotherapy
Incl. Idx
inclusion index
MDC
mean distance to conformity
MR
magnetic resonance imaging
OSCC
oropharyngeal squamous cell cancer
PET
positron emission tomography
ROI
region of interest
Se Idx
sensitivity index
SUVmax
maximum standardized uptake value

Background

Target volume delineation in the treatment of head and neck cancers is a critical issue in the current era of highly conformal radiotherapy with intensity modulated radiotherapy (IMRT) techniques. Steep dose gradients allow sparing of adjacent critical structures but also introduce the potential for geographical misses leading to marginal recurrences if target volume delineation is not accurate [13]. Delineation variability can have a large impact on the dose to the tumour and organs at risk [4], and tumour delineation inaccuracy is recognised as a key source of error in radiotherapy delivery [5, 6]. Computed tomography (CT) remains the core of radiotherapy planning, with the electron density map generated providing accurate dosimetry. However, for delineation of the gross tumour volume (GTV) the limitations of CT-based delineation are widely acknowledged, and were clearly demonstrated in a study of the delineation of supra-glottic tumours with a 50 % degree of agreement between experienced physicians [7].
The integration of multimodality imaging into the radiotherapy planning process provides the opportunity to improve upon the reliance on CT-based tumour delineation. Magnetic resonance imaging (MR) offers excellent soft tissue discrimination, multiplanar imaging capabilities, and importantly, image quality is less susceptible to artefact from dental amalgam compared with CT [8, 9]. Anatomical imaging with CT or MR is inherently limited in allowing discrimination of tumour tissue from surrounding soft tissues. As a result, there has been considerable interest in utilising functional imaging to complement anatomical imaging [10, 11]. 2-Deoxy-2-[18F]-Fluoro-D-glucose positron emission tomography-computed tomography (FDG PET-CT) is a widely used functional imaging technique in oncology; tumour cells exhibit differential glucose uptake (the ‘Warburg effect’) as a basis of the identification of cancer [12]. The potential relevance of FDG PET-CT to radiotherapy planning is highlighted by the finding that loco-regional recurrences occur in-field in regions which are FDG-avid at baseline [13].
Some major institutions employ tight volumetric margins in the treatment of oropharyngeal cancer; for example recently reported series from major institutions [1416] have employed GTV to CTV margins of 0-10 mm. However, the limited soft tissue contrast of CT commonly combined with interference from dental artefact make CT-based delineation of oropharyngeal primary tumours in routine clinical practice particularly challenging [17]. Therefore, the use of multimodality imaging to aid accurate GTV delineation for oropharyngeal primaries is appealing. However, only limited data is available to inform upon the intermodality comparison of CT, MRI and FDG PET-CT for oropharyngeal carcinoma [18, 19].
The primary aim of this prospective study was to quantitatively investigate the variation in oropharyngeal squamous cell carcinoma (OSCC) primary GTV delineation with CT, MR and FDG PET-CT, using volumetric and positional analyses.

Methods

Inclusion criteria

Inclusion criteria for this prospective single centre pilot imaging study were: age ≥18 years, histologically proven squamous cell carcinoma of the head and neck region, WHO performance status 0–2, decision to proceed with (chemo) radiotherapy with curative intent following discussion in a multi-disciplinary meeting, measurable primary cancer on routine pre-treatment imaging (CT and/or MR), and provision of fully informed consent. Patients were excluded from the study if there was poorly controlled diabetes, contraindication to MR or an estimated glomerular filtration rate <30 ml/min/1.73 m2. This study was approved by the Research Ethics Committee (National Research Ethics Committee Yorkshire and the Humber-Bradford, 11/YH/0212) and Administration of Radioactive Substances Advisory Committee (ARSAC); ISRCTN Registry: ISRCTN34165059 and all patients provided informed written consent prior to study entry.
The study protocol included contrast enhanced FDG PET-CT and MR scans performed in a 5-point thermoplastic radiotherapy immobilization mask. Target delineation and treatment proceeded according to institutional clinical protocols.
Fifteen patients entered the study; 1 patient withdrew consent prior to imaging. 11 of the 14 patients who underwent pre-treatment imaging according to the study protocol had a diagnosis of an oropharyngeal cancer and form the basis of this report.

Image acquisition

FDG PET-CT

FDG PET-CT imaging was performed on a 64-section GE Discovery 690 PET-CT system (GE Healthcare, Amersham, UK). Baseline half-body PET acquisition and additional dedicated head and neck acquisition in the immobilization mask (3–4 bed positions, 2 minutes per bed position) from skull vertex to carina was performed for 60 minutes following a 400 MBq injection of Fluorine-18 FDG intravenously. The CT component of the head and neck acquisition was obtained after a 25 second delay following a bolus of 100 ml of iodinated contrast (Niopam 300, Bracco Ltd, High Wycombe, UK) injected at 3 ml/s using the following settings; 120 kV, variable mA (min 10, max 600, noise index 12.2), tube rotation 0.5 s per rotation, pitch 0.969 with a 2.5 mm slice reconstruction. The head and neck component of the FDG PET-CT scan, acquired with a 5-point thermoplastic radiotherapy immobilization mask fitted and room laser alignment to radiopaque reference markers placed on the mask, was also used for radiotherapy planning according to routine clinical protocols.

MR

MR images were acquired on a 1.5 T Siemens Magnetom Avanto system (Siemens Healthcare, Erlangen, Germany). Patients were immobilized in the same treatment position and the same mask as for FDG PET-CT imaging. Axial post-contrast T1-weighted (TR = 831 ms, TE = 8.6 ms, 105 × 2 mm thick contiguous slices, acquired voxel size = 0.9 × 0.9 × 2.0 mm) and axial fat saturated T2-weighted (TR = 4430 ms, TE = 76 ms, voxel size = 0.8 × 0.7 × 3.0 mm) sequences were acquired.

Image co-registration

To allow the spatial comparison of the FDG PET-CT, CT and MR scans, rigid image registration was undertaken using Mirada RTx v1.4 software (Mirada Medical, Oxford, UK) between the CT dataset and the T1-weighted MR dataset. FDG PET-CT scans were inherently spatially co-registered.

Gross tumour volume delineation of primary tumour

In order to simulate the clinical scenario, all outlining was performed with access to clinical history, findings of clinical examination, diagnostic imaging including CT and/or MR performed as part of the diagnostic process prior to entry into the study; FDG PET-CT was not performed as a routine diagnostic investigation and was not therefore available to the observers.

CT and MR based GTV contours

For each patient, five observers (two radiologists and three radiation oncologists) were provided with lists of contours to be performed on study images of primary tumours (CT, MR and combined CT and MR (CT-MR)); the order in which contours were performed was systematically varied for each individual observer. To minimize any potential for recall, a minimum of a two week interval was mandated prior to generating contours for each individual patient using different imaging modalities. For CT based contours, observers were blinded to the MR and PET images acquired as part of the study protocol. For MR based contours, post-contrast T1-weighted and fat saturated T2-weighted images were available and inherently co-registered; and observers were blinded to CT and PET images acquired as part of the study protocol. For combined CT-MR contours, the post-contrast T1-weighted and fat saturated T2-weighted MR and CT were available.

FDG PET-CT GTV contours

Image analysis was undertaken on Mirada RTx v1.4 software. The maximum standardized uptake value (SUVmax) was derived by drawing a region of interest (ROI) encompassing the primary tumour. The PET GTV was defined by using an adaptive thresholding technique, known as the Schaefer algorithm [20], calculated from the mean primary tumour SUV (SUVmean) when applying a 70 % of SUVmax isocontour, the background tissue SUVmean and two scanner specific coefficients (determined from phantom studies).

Data analysis

The data analysis was split into the GTV volume analysis and position analysis. All statistical analysis was performed using Matlab2013b (MATLAB and Statistics Toolbox Release 2013b, The MathWorks, Inc., Natick, Massachusetts, United States).

Volume analysis

Variation in volume of GTV with modality

Linear mixed effects models were used to determine the significance of differences in GTV volume with modality, where modality and clinician role (radiologist or radiation oncologist) were fixed effect variables and patient and clinician were random effect variables [21]. The lack of multiple clinician PET GTVs made inter-clinician variability impractical to model when PET was included, therefore multiple models were used where clinician and clinician title inter-observer variability terms were excluded in the PET GTV model. Data population testing was performed using Q-Q plots and × 1/3 transformations were used to create normal population distributions. A significant ρ-value was considered to be ρ < 0.02 to account for the multiple model comparisons that were required due to the fixed variable comparison method in linear mixed effects models [22].

Variation in volume of GTV with clinician group

The mean GTV volumes for the CT, MR and CT-MR modalities were calculated for each clinician group; radiologist and oncologist. Significance testing between clinician groups for each modality was undertaken using linear mixed effects models.

Variation in inter-observer variability with imaging modality

The variation in inter-observer delineation was measured by taking the mean over all patients of the standard deviation of all observers delineations for each patient within a modality. This was repeated for CT, MR and CT-MR volumes. Significance testing was then performed between modalities using an ANOVA test combined with a Tukey multiple comparison test [23].

Positional analysis

Six positional metrics were calculated using ImSimQA software (v3.1.5, OSL, Shrewsbury, UK): Mean distance to conformity (MDC); Centre of gravity distance (CGD); Conformity index (CI); DICE index; sensitivity index (Se. Idx); and inclusion index (Incl. Idx). The conformity index and DICE index both produce output values between 0 and 1 (using different calculation methods), where 0 represents two contours with no overlap and 1 represents two contours that are perfectly overlapping [24]. The Se. Idx and Incl. Idx calculate the overlapping volume between two contours as a percentage of the volume of one of the two contours. When used together they calculate the percentage of volume A which is within volume B and vice versa. CGD is the distance between the geometric centres of two contours [25]. MDC is the mean of the distances between contours averaged over all positions not within the overlapping contour [25].

Variation in inter-observer variability with imaging modality

The positional inter-observer variability for each modality was assessed by comparing all GTVs delineated using the same modality for each patient. The final positional comparison values were calculated for each metric by calculating the mean of the metric results for each patient and subsequently the overall mean result for all patients. Significance testing was then performed between modalities using an ANOVA test combined with a Tukey multiple comparison test [23].

Variation in GTV position with imaging modality

The variation in GTV position between modalities was assessed using ImSimQA between GTVs delineated by the same clinician and the PET GTV for each patient.

Results

11 patients with histologically proven OSCC entered the study. Baseline characteristics are summarised in Table 1. Diagnostic imaging included MR for all patients. The median time between FDG PET-CT and MR scans performed within the study was 7 days (range 0–12). Within the time constraints for completing contouring of the primary tumour GTV, all CT contours, 51/55 MR, and 42/55 CT-MR GTV contours were completed; 10/11 combined CT-MR GTVs were incomplete for one radiologist. A representative example of contours delineated by each observer on CT, MR, CT-MR and by automatic segmentation of PET is shown in Fig. 1. Figure 2 provides an example of contouring by a single observer on CT, MR, CT-MR and by automatic segmentation of PET superimposed upon the CT scan.
Table 1
Patient demographics and tumour characteristics
Patient
Primary Tumor Site
T-stage
N-stage
1
Tonsil
2
2b
2
Base of tongue
3
2c
3
Base of tongue
4
2b
4
Base of tongue
4a
1
5
Base of tongue
2
1
6
Tonsil/base of tongue
1
2b
7
Base of tongue
2
2b
8
Base of tongue
2
2b
9
Tonsil/soft palate
4a
1
10
Base of tongue
1
2b
11
Soft palate
4a
2b

Volume analysis of GTVs

The volume of the primary tumour contours for CT, MR, CT-MR and PET are shown for each patient in Fig. 3 and are summarised in Table 2. Table 2 illustrates the median and mean volumes of GTVs delineated on CT, MR, CT-MR and generated by automatic segmentation of the PET. Figure 4 demonstrates the volume of GTVs delineated by individual observers using CT, MR and CT-MR. Table 3 illustrates the standard deviation of the GTV volume delineations for each patient for each modality. Compared with CT GTVs, CT-MR GTVs were significantly larger (p = 0.0052). MR had a significantly smaller GTV volume standard deviation than CT (ρ-value < 0.05). Average PET GTVs were smaller than CT, MR and CT-MR volumes, a difference which was significant compared with MR and CT-MR GTVs (p = 0.003 and p < 0.001 respectively).
Table 2
Summary of volume of GTVs contoured using CT, MR, CT-MR and PET
Modality
Modality Volumes (cm3)
Mean
Median
Mean St. Dev.
Range
Mean GTV Volume (Statistically Significant p-values)
Max
Min
CT
11.9
11.6
4.5
34.5
1.6
CT < CT-MR, p = 0.005
CT-MR
14.1
14.0
3.7
40.2
2.2
CT < MR, p = 0.049
MR
12.7
12.8
2.5
34.4
2.2
MR < CT-MR, p = 0.33
PET
9.5
8.8
-
24.6
1.5
PET < CT, p = 0.059
PET < CT-MR, ρ <0.001PET < MR, ρ = 0.003
Table 3
The standard deviation of the GTV volume delineations undertaken by clinicians for each patient for each modality
Patient
Standard Deviations (cm3)
CT
CT-MR
MR
1
3.59
4.17
3.33
2
3.95
5.19
3.32
3
4.61
3.75
1.36
4
4.36
4.82
1.15
5
4.29
3.16
3.37
6
2.01
2.81
0.48
7
1.84
2.84
2.15
8
8.65
4.87
2.99
9
5.63
3.91
2.40
10
1.62
0.83
0.93
11
8.59
4.42
5.93
Mean
4.47
3.71
2.49
Significant differences were found between radiologist- and oncologist-delineated GTV volumes for each individual modality: CT (radiologist 9.1 cm3 vs. oncologist 13.8 cm3, ρ = 0.022); MR (radiologist 9.9 cm3 vs. oncologist 14.4 cm3, ρ = 0.00013); CT-MR (radiologist 10.5 cm3 vs. oncologist 15.8 cm3, ρ = 0.12); and overall for all modalities (radiologist 9.7 cm3 vs. oncologist 14.6 cm3, ρ = 0.001).

Positional analysis of GTVs

The analysis of positional inter-observer variability is summarized in Table 4. Inter-observer variability was found to be significantly higher for CT compared to MR and CT-MR, with no significant differences between MR and CT-MR contours.
Table 4
Mean positional metric results for the inter-observer variability
 
Mean Inter-observer Variability (SD)
Significant Differences with a confidence level of 95 %
CT
CT-MR
MR
(p-value <0.05)
CI
0.37 (0.12)
0.44 (0.09)
0.47 (0.09)
CT < CT-MR
CT < MR
MDC (mm)
8.8 (4.1)
7.5 (2.6)
6.9 (2.5)
MR < CT
CGD (mm)
7.7 (4.5)
4.8 (2.6)
4.4 (2.5)
CT-MR < CT
MR < CT
DICE
0.57 (0.15)
0.66 (0.09)
0.69 (0.10)
CT < CT-MR
CT < MR
The results of the comparison of GTV position between CT, MR, CT-MR and PET is shown in Table 5. CT, MR and CT-MR were found to all have similar, large differences in position compared to PET. A mean of 64 %, 74 % and 77 % of the PET GTV were included within the CT, MR and CT-MR GTVs respectively. A mean of 56 %, 58 %, 54 % of the CT, MR and CT-MR GTVs were included within the PET GTVs. MR and CT GTVs were found to have a low level of overlap and a large variation in CGD and MDC. A mean of 57 % of the MR GTV was included within the CT GTV; conversely a mean of 63 % of the CT GTV was included within the MR GTV. MR and CT-MR were found to have a high level of overlap and a small variation in CGD and MDC; a mean of 85 % of the CT-MR GTV was included within the MR GTV .
Table 5
Inter-modality positional GTV analysis
Metric
Inter-Modality Variability (SD)
CT-PET
MR-PET
CTMR-PET
CT-MR
CT-CTMR
MR-CTMR
CI
0.33 (0.09)
0.36 (0.05)
0.36 (0.07)
0.35 (0.09)
0.40 (0.08)
0.74 (0.17)
MDC (mm)
7.8 (3.1)
6.9 (2.4)
7.3 (2.87)
7.1 (1.7)
6.7 (1.6)
4.1 (0.9)
CGD (mm)
6.1 (3.2)
4.7 (2.2)
4.9 (3.64)
5.9 (3.1)
5.4 (2.7)
1.8 (1.4)
DICE
0.55 (0.11)
0.61 (0.06)
0.60 (0.08)
0.57 (0.09)
0.62 (0.09)
0.87 (0.10)
Se. Idxa
0.56 (0.15)
0.58 (0.11)
0.54 (0.13)
0.63 (0.14)
0.67 (0.14)
0.91 (0.09)
Incl. Idxb
0.64 (0.18)
0.74 (0.11)
0.77 (0.13)
0.57 (0.14)
0.63 (0.14)
0.85 (0.13)
aSe. Idx is expressed as a proportion of the first named GTV contained within the second ie. for CT-PET Se. Idx is the proportion of the CT-GTV within the PET-GTV
bIncl. Idx is expressed as a proportion of the second named GTV contained within the first ie. for CT-PET Incl. Idx is the proportion of the PET-GTV within the CT-GTV

Discussion

There is considerable interest in improving the accuracy of tumour delineation in the era of highly conformal IMRT [10]. The current standard of CT-based delineation is particularly limited for oropharyngeal primary tumours, which are often barely visible even with contrast-enhanced CT-simulation scans [9, 19]. Multimodality imaging has the potential to improve the accuracy and reproducibility of tumour delineation.
Clinical experience suggests that oropharyngeal primary tumours are more readily identifiable on MR than CT. There was no significant difference in the volume of GTVs outlined on MR and CT. Although there was considerable inter-observer variability for CT, MR and CT-MR GTV delineation, there was significantly less variability for MR and CT-MR than for CT GTVs. Analysis of positional metrics demonstrated a low degree of volume overlap between CT and MR GTVs. MR and CT-MR GTVs showed a large degree of overlap; this is likely to reflect the clinicians’ propensity to base the CT-MR GTV contours on the MR on which the edge of the primary tumour is more readily identifiable. These data suggest that the implementation of either combined CT-MR or MR-based planning would have a considerable impact upon GTV delineation compared with CT-based planning.
These data are broadly in line with a previous study by Daisne et al. [18] who did not find a significant difference in the volume of GTVs contoured by a single observer on CT or MR in a series of 10 patients with oropharyngeal carcinoma. Consistent with our results, this series also showed significant areas of non-overlap between CT and MR defined GTVs. Another prior study by Ahmed et al. compared CT and MR-based GTVs in a series of six patients with base of tongue cancers [17]. This study also found that there was only limited overlap between CT and MR GTVs although, by contrast with our results, reported that there was no difference in inter-observer variability between CT and MR and that the primary tumour GTV was larger on MR than CT.
Interestingly our data showed that GTVs delineated on CT, MR or CT-MR were significantly smaller when contoured by radiologists compared with oncologists. Similarly, Ahmed et al. [17] reported that average GTVs delineated by a single radiologist were smaller than those contoured by oncologists. Clinical information and the findings of clinical examination remain critical to avoid geometric misses due to disease such as mucosal extension which may not be identified on imaging. Variations in this study between oncologists and radiologists emphasize the potential benefit of a multidisciplinary collaborative approach to GTV delineation, including radiation oncologists, radiologists and surgeons (who may have valuable additional input, for example based on the findings of an examination under anaesthetic).
With regard to the use of FDG PET-CT for radiotherapy planning, a key issue is the methodology used to define the edge of the functional volume of interest. Current generation PET-CT scanners have limitations including image noise, voxel sizes of 4-5 mm, partial volume effects and reconstruction uncertainties which lead to blurring of the edge of PET-avid tumours [9]. A host of methods have been proposed for ‘contouring’ a PET-avid tumour, varying from manual visual delineation to fully automated algorithms [26, 27]. Altering the SUV scale when viewing PET images can alter the apparent tumour volume by a factor of around two [28]; manual delineation is therefore an inevitably subjective process leading to inter-observer variability [29]. Although a host of automated methods have been developed for segmenting PET-avid tumours [30], few have histopathological correlation. In the absence of a widely accepted method, we made a pragmatic decision to use a previously described contrast-orientated method with coefficients derived from individual phantom data on the PET-CT scanner which had performed favourably in comparative phantom and simulated patient studies [20, 31, 32], and pathological correlation in other tumour sites [33]. The results from the PET delineation component of this study need to be interpreted with the unresolved difficulty regarding the optimal method of PET delineation in mind.
PET-based GTVs were significantly smaller than MR and CT-MR GTVs (Table 2), and non-significantly smaller than CT GTVs. Despite this difference in volume, there were substantial areas of the PET GTV which were not included in the CT or MR GTVs; conversely large areas of the CT and MR GTVs were not included within the PET GTV. Consistent with these findings, was the reported series of Daisne et al. [18] of 10 patients with oropharyngeal cancer in which the PET GTV was significantly smaller than CT or MR-based GTVs, with areas of mismatch between PET GTVs and CT or MR GTVs. Interestingly, for patient 6 the PET GTV volume was greater than any other modality GTV volume. This was in contrast to all other patients and the overall results of this study. This could be due to the inherent difficulties in delineating a PET GTV that occur, even using the semi-automatic contouring algorithm, when the GTV 18−FDG uptake resides in an area of natural 18−FDG uptake caused by, for example, inflammation or brown fat. In such cases the PET GTV delineation can incorrectly identify physiological 18−FDG uptake as tumour uptake, leading to false positive GTV tissue and a larger GTV delineation than appropriate. In this case, when visually reviewed it was found that the PET GTV extended further inferiorly compared to the other modality GTVs and also was in a region of relatively high background uptake around the tonsils.
The main limitation of this series is the absence of histological validation. Two series including nine [18] and ten [34] patients who underwent a laryngectomy/laryngopharyngectomy for laryngeal or hypopharyngeal cancer following CT, MR and FDG PET-CT imaging have provided histological validation. Both series reported that the pathological tumour was smaller than any individual imaging modality, but that no single imaging modality encompassed the whole pathological tumour. The inability of imaging to depict the whole tumour volume was thought likely to be due to superficial mucosal extension in that tumour site. No similar series with pathological correlation have been performed for oropharynx cancers to the best of our knowledge. By contrast with the larynx, a resected specimen from the oropharynx would lack the cartilage structure to provide registration with imaging; in addition, oropharyngeal cancer is commonly managed non-surgically. In the absence of pathological validation, our series is descriptive without a ground truth; it is important to recognise that increasing the consistency of contours does not necessarily imply superior target volume delineation. Other limitations include the necessity for co-registration between MR and FDG PET-CT scans; since both scans were performed within the same immobilisation mask it would be expected that co-registration errors would be small.
In the absence of histological validation, it is not possible to select which imaging modality is superior for target volume delineation. It is perhaps not surprising that anatomical and functional imaging techniques provide potentially complimentary information. The smaller FDG-PET volume may be demonstrating the inability of the other techniques to discriminate between inactive necrotic/cystic tissue and the active cancerous tissue; however, FDG uptake is non-specific, so areas of FDG uptake beyond CT or MRI-delineated tumour volume may relate to adjacent inflammatory changes or alternatively areas of sub-clinical tumour infiltration. It seems likely that incorporating multimodality imaging with accurate clinical examination will minimise the risk of a geographical miss. For example, PET may add to the accuracy of target delineation based on anatomical imaging by the detection of areas which are FDG-avid but sub-clinical on CT and MR. This is supported by the findings of Thiagarajan et al. [19] who reported on the impact of PET and MR and physical examination in target delineation in a series of 41 patients with oropharyngeal cancer. This study compared a reference GTV based on CT, PET, MR and physical examination; the concordance indices for both GTVs based on CT and MR or based on CT and PET were low compared with the reference GTV, implying a potential benefit for incorporating all imaging modalities. Importantly, the study highlighted the importance of clinical examination in addition to multimodality imaging for the detection of mucosal extension.
These data show the potential complimentary role for multimodality imaging in target volume delineation. Clearly additional multicentre prospective clinical studies are needed to analyse the impact of this approach on clinical outcomes. Incorporation of multimodality imaging may be more beneficial in the advanced disease setting (patients in this study all had stage III/IV disease) compared with the treatment of early disease. The impact of multimodality imaging on the balance of achieving local control whilst minimising toxicity will depend upon the approach and margins adopted to delineating the clinical target volume, as a multimodality imaging-defined GTV may be larger than that defined on CTV alone. A cost-effectiveness analysis will be useful prior to widespread incorporation into routine practice.

Conclusion

In summary, this study showed that using CT, MR and PET produced significantly different GTVs which varied in volume and/or position, with no single imaging modality encompassing all potential GTV regions. These data support the increased incorporation of multimodality imaging for target volume delineation, to minimise the risk of geographical misses.

Acknowledgements

None of authors received individual funding for participating in this study. The trial was funded by the ‘Leeds Teaching Hospitals Charitable Foundation’. The funding body had no role in study design, data collection, analysis or interpretation of data, manuscript preparation or decision with regards to publication.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.

Competing interests

The authors declare that they have no competing interests.

Authors’ contributions

DB: Image analysis, data analysis, manuscript preparation and editing. AS: Study design, image analysis, manuscript editing. JS: Study design, data analysis, manuscript editing. SR: Contouring, manuscript editing. MS: Contouring, manuscript editing. BC: Contouring, manuscript editing. DW: Data analysis, manuscript editing. NR: Study design, manuscript editing. GM: Phantom measurements, image analysis, manuscript editing. EK: Contouring, manuscript editing. EB: Contouring, manuscript editing. MS: Study design, manuscript editing. RS: Data analysis, image registration, manuscript preparation and editing. RP: Study design, study co-ordination/recruitment, data analysis, manuscript preparation and editing. All authors read and approved the final manuscript.
Literatur
1.
Zurück zum Zitat David MB, Eisbruch A. Delineating neck targets for intensity- modulated radiation therapy of head and neck cancer. What we learned from marginal recurrences? Front Radiat Ther Oncol. 2007;40:193–207.CrossRefPubMed David MB, Eisbruch A. Delineating neck targets for intensity- modulated radiation therapy of head and neck cancer. What we learned from marginal recurrences? Front Radiat Ther Oncol. 2007;40:193–207.CrossRefPubMed
2.
Zurück zum Zitat Eisbruch A, Marsh LH, Dawson LA, Bradford CR, Teknos TN, Chepeha DB, et al. Recurrences near base of skull after IMRT for head-and-neck cancer: implications for target delineation in high neck and for parotid gland sparing. Int J Radiat Oncol Biol Phys. 2004;59(1):28–42.CrossRefPubMed Eisbruch A, Marsh LH, Dawson LA, Bradford CR, Teknos TN, Chepeha DB, et al. Recurrences near base of skull after IMRT for head-and-neck cancer: implications for target delineation in high neck and for parotid gland sparing. Int J Radiat Oncol Biol Phys. 2004;59(1):28–42.CrossRefPubMed
3.
Zurück zum Zitat Schoenfeld GO, Amdur RJ, Morris CG, Li JG, Hinerman RW, Mendenhall WM. Patterns of failure and toxicity after intensity-modulated radiotherapy for head and neck cancer. Int J Radiat Oncol Biol Phys. 2008;71(2):377–85.CrossRefPubMed Schoenfeld GO, Amdur RJ, Morris CG, Li JG, Hinerman RW, Mendenhall WM. Patterns of failure and toxicity after intensity-modulated radiotherapy for head and neck cancer. Int J Radiat Oncol Biol Phys. 2008;71(2):377–85.CrossRefPubMed
4.
Zurück zum Zitat Rasch C, Steenbakkers R, Van Herk M. Target definition in prostate, head, and neck. Semin Radiat Oncol. 2005;15(3):136–45.CrossRefPubMed Rasch C, Steenbakkers R, Van Herk M. Target definition in prostate, head, and neck. Semin Radiat Oncol. 2005;15(3):136–45.CrossRefPubMed
6.
Zurück zum Zitat Rasch CR, Steenbakkers RJ, Fitton I, Duppen JC, Nowak PJ, Pameijer FA, et al. Decreased 3D observer variation with matched CT-MRI, for target delineation in Nasopharynx cancer. Radiat Oncol. 2010;5:21.CrossRefPubMedPubMedCentral Rasch CR, Steenbakkers RJ, Fitton I, Duppen JC, Nowak PJ, Pameijer FA, et al. Decreased 3D observer variation with matched CT-MRI, for target delineation in Nasopharynx cancer. Radiat Oncol. 2010;5:21.CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Cooper JS, Mukherji SK, Toledano AY, Beldon C, Schmalfuss IM, Amdur R, et al. An evaluation of the variability of tumor-shape definition derived by experienced observers from CT images of supraglottic carcinomas (ACRIN protocol 6658). Int J Radiat Oncol Biol Phys. 2007;67(4):972–5.CrossRefPubMedPubMedCentral Cooper JS, Mukherji SK, Toledano AY, Beldon C, Schmalfuss IM, Amdur R, et al. An evaluation of the variability of tumor-shape definition derived by experienced observers from CT images of supraglottic carcinomas (ACRIN protocol 6658). Int J Radiat Oncol Biol Phys. 2007;67(4):972–5.CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Maroldi R, Battaglia G, Farina D, Maculotti P, Chiesa A. Tumours of the oropharynx and oral cavity: perineural spread and bone invasion. JBR-BTR. 1999;82(6):294–300.PubMed Maroldi R, Battaglia G, Farina D, Maculotti P, Chiesa A. Tumours of the oropharynx and oral cavity: perineural spread and bone invasion. JBR-BTR. 1999;82(6):294–300.PubMed
9.
Zurück zum Zitat Bhatnagar P, Subesinghe M, Patel C, Prestwich R, Scarsbrook AF. Functional imaging for radiation treatment planning, response assessment, and adaptive therapy in head and neck cancer. Radiographics. 2013;33(7):1909–29.CrossRefPubMed Bhatnagar P, Subesinghe M, Patel C, Prestwich R, Scarsbrook AF. Functional imaging for radiation treatment planning, response assessment, and adaptive therapy in head and neck cancer. Radiographics. 2013;33(7):1909–29.CrossRefPubMed
10.
Zurück zum Zitat Prestwich RJ, Sykes J, Carey B, Sen M, Dyker KE, Scarsbrook AF. Improving target definition for head and neck radiotherapy: a place for magnetic resonance imaging and 18-fluoride fluorodeoxyglucose positron emission tomography? Clin Oncol (R Coll Radiol). 2012;24(8):577–89.CrossRef Prestwich RJ, Sykes J, Carey B, Sen M, Dyker KE, Scarsbrook AF. Improving target definition for head and neck radiotherapy: a place for magnetic resonance imaging and 18-fluoride fluorodeoxyglucose positron emission tomography? Clin Oncol (R Coll Radiol). 2012;24(8):577–89.CrossRef
11.
Zurück zum Zitat Gregoire V, Haustermans K. Functional image-guided intensity modulated radiation therapy: integration of the tumour microenvironment in treatment planning. Eur J Cancer. 2009;45 Suppl 1:459–60.CrossRefPubMed Gregoire V, Haustermans K. Functional image-guided intensity modulated radiation therapy: integration of the tumour microenvironment in treatment planning. Eur J Cancer. 2009;45 Suppl 1:459–60.CrossRefPubMed
12.
Zurück zum Zitat Warburg O. The metabolism of tumours. London: Constable; 1930. Warburg O. The metabolism of tumours. London: Constable; 1930.
13.
Zurück zum Zitat Due AK, Vogelius IR, Aznar MC, Bentzen SM, Berthelsen AK, Korreman SS, et al. Recurrences after intensity modulated radiotherapy for head and neck squamous cell carcinoma more likely to originate from regions with high baseline [18 F]-FDG uptake. Radiother Oncol. 2014;111(3):360–5.CrossRefPubMedPubMedCentral Due AK, Vogelius IR, Aznar MC, Bentzen SM, Berthelsen AK, Korreman SS, et al. Recurrences after intensity modulated radiotherapy for head and neck squamous cell carcinoma more likely to originate from regions with high baseline [18 F]-FDG uptake. Radiother Oncol. 2014;111(3):360–5.CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Garden AS, Dong L, Morrison WH, Stugis EM, Glisson BS, Frank SJ, et al. Patterns of disease recurrence following treatment of oropharyngeal cancer with intensity modulated radiation therapy. Int J Radiat Oncol Biol Phys. 2013;85(4):941–7.CrossRefPubMed Garden AS, Dong L, Morrison WH, Stugis EM, Glisson BS, Frank SJ, et al. Patterns of disease recurrence following treatment of oropharyngeal cancer with intensity modulated radiation therapy. Int J Radiat Oncol Biol Phys. 2013;85(4):941–7.CrossRefPubMed
15.
Zurück zum Zitat Setton J, Caria N, Romanyshyn J, Koutcher L, Wolden SL, Zelefsky MJ, et al. Intensity-modulated radiotherapy in the treatment of oropharyngeal cancer: an update of the Memorial Sloan-Kettering Cancer Center experience. Int J Radiat Oncol Biol Phys. 2012;82(1):291–8.CrossRefPubMed Setton J, Caria N, Romanyshyn J, Koutcher L, Wolden SL, Zelefsky MJ, et al. Intensity-modulated radiotherapy in the treatment of oropharyngeal cancer: an update of the Memorial Sloan-Kettering Cancer Center experience. Int J Radiat Oncol Biol Phys. 2012;82(1):291–8.CrossRefPubMed
16.
Zurück zum Zitat Raktoe SA, Dehnad H, Raaijmakers CP, Braunius W, Terhaard CH. Origin of tumor recurrence after intensity modulated radiation therapy for oropharyngeal squamous cell carcinoma. Int J Radiat Oncol Biol Phys. 2013;85(1):136–41.CrossRefPubMed Raktoe SA, Dehnad H, Raaijmakers CP, Braunius W, Terhaard CH. Origin of tumor recurrence after intensity modulated radiation therapy for oropharyngeal squamous cell carcinoma. Int J Radiat Oncol Biol Phys. 2013;85(1):136–41.CrossRefPubMed
17.
Zurück zum Zitat Ahmed M, Schmidt M, Sohaib A, Kong C, Burke K, Richardson C, et al. The value of magnetic resonance imaging in target volume delineation of base of tongue tumours--a study using flexible surface coils. Radiother Oncol. 2010;94(2):161–7.CrossRefPubMed Ahmed M, Schmidt M, Sohaib A, Kong C, Burke K, Richardson C, et al. The value of magnetic resonance imaging in target volume delineation of base of tongue tumours--a study using flexible surface coils. Radiother Oncol. 2010;94(2):161–7.CrossRefPubMed
18.
Zurück zum Zitat Daisne JF, Duprez T, Weynand B, Lonneux M, Hamoir M, Reychler H, et al. Tumor volume in pharyngolaryngeal squamous cell carcinoma: comparison at CT, MR imaging, and FDG PET and validation with surgical specimen. Radiology. 2004;233(1):93–100.CrossRefPubMed Daisne JF, Duprez T, Weynand B, Lonneux M, Hamoir M, Reychler H, et al. Tumor volume in pharyngolaryngeal squamous cell carcinoma: comparison at CT, MR imaging, and FDG PET and validation with surgical specimen. Radiology. 2004;233(1):93–100.CrossRefPubMed
19.
Zurück zum Zitat Thiagarajan A, Caria N, Schoder H, Iyer NG, Wolden S, Wong RJ, et al. Target volume delineation in oropharyngeal cancer: impact of PET, MRI, and physical examination. Int J Radiat Oncol Biol Phys. 2012;83(1):220–7.CrossRefPubMed Thiagarajan A, Caria N, Schoder H, Iyer NG, Wolden S, Wong RJ, et al. Target volume delineation in oropharyngeal cancer: impact of PET, MRI, and physical examination. Int J Radiat Oncol Biol Phys. 2012;83(1):220–7.CrossRefPubMed
20.
Zurück zum Zitat Schaefer A, Kremp S, Hellwig D, Rube C, Kirsch CM, Nestle U. A contrast-oriented algorithm for FDG-PET-based delineation of tumour volumes for the radiotherapy of lung cancer: derivation from phantom measurements and validation in patient data. Eur J Nucl Med Mol Imaging. 2008;35(11):1989–99.CrossRefPubMed Schaefer A, Kremp S, Hellwig D, Rube C, Kirsch CM, Nestle U. A contrast-oriented algorithm for FDG-PET-based delineation of tumour volumes for the radiotherapy of lung cancer: derivation from phantom measurements and validation in patient data. Eur J Nucl Med Mol Imaging. 2008;35(11):1989–99.CrossRefPubMed
21.
Zurück zum Zitat West BT. Linear mixed models: A practice guide using statistical software, 2nd. London: CRC Press; 2015. West BT. Linear mixed models: A practice guide using statistical software, 2nd. London: CRC Press; 2015.
23.
Zurück zum Zitat Moore DS: The basic practice of statistics. 2008; 5th edn: W. H. Freeman and Company. Moore DS: The basic practice of statistics. 2008; 5th edn: W. H. Freeman and Company.
24.
Zurück zum Zitat Dice LR. Measures of the amount of ecologic association between species. Ecology. 1945;26(3):297–302.CrossRef Dice LR. Measures of the amount of ecologic association between species. Ecology. 1945;26(3):297–302.CrossRef
25.
Zurück zum Zitat Jena R, Kirkby NF, Burton KE, Hoole AC, Tan LT, Burnet NG. A novel algorithm for the morphometric assessment of radiotherapy treatment planning volumes. Br J Radiol. 2010;83(985):44–51.CrossRefPubMedPubMedCentral Jena R, Kirkby NF, Burton KE, Hoole AC, Tan LT, Burnet NG. A novel algorithm for the morphometric assessment of radiotherapy treatment planning volumes. Br J Radiol. 2010;83(985):44–51.CrossRefPubMedPubMedCentral
26.
Zurück zum Zitat Shepherd T, Teras M, Beichel RR, Boellaard R, Bruynooghe M, Dicken V, et al. Comparative study with new accuracy metrics for target volume contouring in PET image guided radiation therapy. IEEE Trans Med Imaging. 2012;31(11):2006–24.CrossRefPubMed Shepherd T, Teras M, Beichel RR, Boellaard R, Bruynooghe M, Dicken V, et al. Comparative study with new accuracy metrics for target volume contouring in PET image guided radiation therapy. IEEE Trans Med Imaging. 2012;31(11):2006–24.CrossRefPubMed
27.
Zurück zum Zitat Lee JA. Segmentation of positron emission tomography images: some recommendations for target delineation in radiation oncology. Radiother Oncol. 2010;96(3):302–7.CrossRefPubMed Lee JA. Segmentation of positron emission tomography images: some recommendations for target delineation in radiation oncology. Radiother Oncol. 2010;96(3):302–7.CrossRefPubMed
28.
Zurück zum Zitat Troost EG, Schinagl DA, Bussink J, Boerman OC, van der Kogel AJ, Oyen WJ, et al. Innovations in radiotherapy planning of head and neck cancers: role of PET. J Nucl Med. 2010;51(1):66–76.CrossRefPubMed Troost EG, Schinagl DA, Bussink J, Boerman OC, van der Kogel AJ, Oyen WJ, et al. Innovations in radiotherapy planning of head and neck cancers: role of PET. J Nucl Med. 2010;51(1):66–76.CrossRefPubMed
29.
Zurück zum Zitat Riegel AC, Berson AM, Destian S, Ng T, Tena LB, Mitnick RJ, et al. Variability of gross tumor volume delineation in head-and-neck cancer using CT and PET/CT fusion. Int J Radiat Oncol Biol Phys. 2006;65(3):726–32.CrossRefPubMed Riegel AC, Berson AM, Destian S, Ng T, Tena LB, Mitnick RJ, et al. Variability of gross tumor volume delineation in head-and-neck cancer using CT and PET/CT fusion. Int J Radiat Oncol Biol Phys. 2006;65(3):726–32.CrossRefPubMed
30.
Zurück zum Zitat Zaidi H, El Naqa I. PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques. Eur J Nucl Med Mol Imaging. 2010;37(11):2165–87.CrossRefPubMed Zaidi H, El Naqa I. PET-guided delineation of radiation therapy treatment volumes: a survey of image segmentation techniques. Eur J Nucl Med Mol Imaging. 2010;37(11):2165–87.CrossRefPubMed
31.
Zurück zum Zitat Tylski P, Stute S, Grotus N, Doyeux K, Hapdey S, Gardin I, et al. Comparative assessment of methods for estimating tumor volume and standardized uptake value in (18) F-FDG PET. J Nucl Med. 2010;51(2):268–76.CrossRefPubMed Tylski P, Stute S, Grotus N, Doyeux K, Hapdey S, Gardin I, et al. Comparative assessment of methods for estimating tumor volume and standardized uptake value in (18) F-FDG PET. J Nucl Med. 2010;51(2):268–76.CrossRefPubMed
32.
Zurück zum Zitat Cheebsumon P, Yaqub M, Van Velden FH, Hoekstra OS, Lammertsma AA, Boellaard R. Impact of [(1) (8) F] FDG PET imaging parameters on automatic tumour delineation: need for improved tumour delineation methodology. Eur J Nucl Med Mol Imaging. 2011;38(12):2136–44.CrossRefPubMedPubMedCentral Cheebsumon P, Yaqub M, Van Velden FH, Hoekstra OS, Lammertsma AA, Boellaard R. Impact of [(1) (8) F] FDG PET imaging parameters on automatic tumour delineation: need for improved tumour delineation methodology. Eur J Nucl Med Mol Imaging. 2011;38(12):2136–44.CrossRefPubMedPubMedCentral
33.
Zurück zum Zitat Cheebsumon P, Boellaard R, De Ruysscher D, Van Elmpt W, Van Baardwijk A, Yaqub M, et al. Assessment of tumour size in PET/CT lung cancer studies: PET- and CT-based methods compared to pathology. EJNMMI Res. 2012;2(1):56.CrossRefPubMedPubMedCentral Cheebsumon P, Boellaard R, De Ruysscher D, Van Elmpt W, Van Baardwijk A, Yaqub M, et al. Assessment of tumour size in PET/CT lung cancer studies: PET- and CT-based methods compared to pathology. EJNMMI Res. 2012;2(1):56.CrossRefPubMedPubMedCentral
34.
Zurück zum Zitat Caldas-Magalhaes J, Kasperts N, Kooij N, van den Berg CA, Terhaard CH, Raaijmakers CP, et al. Validation of imaging with pathology in laryngeal cancer: accuracy of the registration methodology. Int J Radiat Oncol Biol Phys. 2012;82(2):e289–98.CrossRefPubMed Caldas-Magalhaes J, Kasperts N, Kooij N, van den Berg CA, Terhaard CH, Raaijmakers CP, et al. Validation of imaging with pathology in laryngeal cancer: accuracy of the registration methodology. Int J Radiat Oncol Biol Phys. 2012;82(2):e289–98.CrossRefPubMed
Metadaten
Titel
Multimodality imaging with CT, MR and FDG-PET for radiotherapy target volume delineation in oropharyngeal squamous cell carcinoma
verfasst von
David Bird
Andrew F. Scarsbrook
Jonathan Sykes
Satiavani Ramasamy
Manil Subesinghe
Brendan Carey
Daniel J. Wilson
Neil Roberts
Gary McDermott
Ebru Karakaya
Evrim Bayman
Mehmet Sen
Richard Speight
Robin J.D. Prestwich
Publikationsdatum
01.12.2015
Verlag
BioMed Central
Erschienen in
BMC Cancer / Ausgabe 1/2015
Elektronische ISSN: 1471-2407
DOI
https://doi.org/10.1186/s12885-015-1867-8

Weitere Artikel der Ausgabe 1/2015

BMC Cancer 1/2015 Zur Ausgabe

Update Onkologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.