Skip to main content
Erschienen in: BMC Pulmonary Medicine 1/2017

Open Access 01.12.2017 | Research article

End-tidal capnographic monitoring to detect apnea episodes during flexible bronchoscopy under sedation

verfasst von: Tsukasa Ishiwata, Kenji Tsushima, Mai Fujie, Kenichi Suzuki, Kosuke Hirota, Mitsuhiro Abe, Naoko Kawata, Jiro Terada, Koichiro Tatsumi

Erschienen in: BMC Pulmonary Medicine | Ausgabe 1/2017

Abstract

Background

Apnea developing as a result of oversedation is a potential clinical problem in patients undergoing flexible bronchoscopy (FB) under sedation. However, there are no reports of evaluation using a standardized method of the frequency of occurrence of apnea episodes during FB under sedation. The aim of this study was to investigate the frequency of apnea episodes during FB under sedation in the clinical setting by end-tidal capnography.

Methods

This study was a single-institution retrospective review of a prospectively maintained database and medical records, including capnographic data, from April 2015 to March 2016. We enrolled patients who were sedated with midazolam and underwent diagnostic FB under end-tidal capnographic monitoring. Apnea was defined as cessation of airflow for more than 10 s.

Results

Data from a total of 121 eligible patients were analyzed. A total of 131 apnea episodes (median duration 33 s) were recorded in 59 patients (48.8%). Prolonged apnea episodes lasting for more than 30 s occurred in 24 patients (19.8%). Furthermore, 55 apnea episodes (42.0%) were followed by a decline of the SpO2 by ≥4% from the baseline.

Conclusions

In this study, end-tidal capnography revealed the occurrence of apnea episodes at a high frequency in patients undergoing FB under sedation in the clinical setting.
Abkürzungen
ASA
American Society of Anethesiologists
FB
Flexible bronchoscopy
IQR
Interquartile ranges
SD
Standard deviations

Background

Sedation is required for relieving the anxiety and calming of patients during a wide variety of medical procedures [1]. However, inadvertent oversedation may sometimes occur, leading to deep sedation and apnea episodes [2]. Bronchoscopic procedures require moderate sedation to alleviate the patient’s anxiety and to suppress the cough reflex. However, this is associated with the risk of respiratory depression developing during prolonged procedures, especially diagnostic bronchoscopies, as administration of high doses of sedatives is often necessitated during such procedures. Furthermore, oxygen desaturation is known to occur at a higher frequency during flexible bronchoscopy (FB) than during other endoscopic procedures, e.g., esophagogastroduodenoscopy and colonoscopy, because of the excessive respiratory secretions and endobronchial bleeding encountered during this procedure.
Until date, the frequency of occurrence of apnea episodes during FB under sedation has never been precisely evaluated using a standardized method. Although a previous report referred to the necessity of respiratory monitoring and possible usefulness of end-tidal capnography during FB [3], supportive clinical data have not yet been obtained. The aim of this study was to investigate the actual frequency of occurrence of apnea episodes during FB under sedation by end-tidal capnography.

Methods

This study was a retrospective review of a prospectively maintained database and medical records, including capnographic data, at our institution. This study was conducted at the Chiba University hospital (Chiba, Japan). The study protocol was submitted for Institutional Review Board approval (Chiba #2455). Written informed consent for the performance of bronchoscopy was obtained from all participants.

Subjects

From April 2015 to March 2016, we enrolled patients who underwent diagnostic FB under midazolam sedation. The performed FB procedures included endobronchial biopsy, bronchial brushing, transbronchial biopsy, transbronchial needle aspiration (including endobronchial ultrasound-guided needle aspiration) and bronchial washing. For each patient, the following medical information was recorded from the medical records: age, gender, body mass index, American Society of Anesthesiologists (ASA) physical status classification [4], frequency of comorbidities, and final diagnosis of the lung disease.

Sedation and patient monitoring

Midazolam was administered by intravenous bolus injection at the starting dose of 1–3 mg, with additional doses of 0.5–1 mg administered as needed for moderate sedation by pulmonologists, not anesthesiologists. Adjustment of the initial and additional doses of midazolam was left to the bronchoscopist’s discretion, guided by the criteria for moderate sedation in the ASA clinical practice guidelines [1].
Tracheal intubation was not performed. After spraying 4% lidocaine onto the patient’s throat to induce local anesthesia, a FB was inserted through the mouth of the patient lying supine on the bed. An Olympus (Tokyo, Japan) BF-260 videobronchoscope (4.9 mm outer diameter) was used. Additional local anesthesia with 1% lidocaine was used as appropriate. All patients underwent electrocardiographic monitoring and pulse oximetry as standard monitoring procedures. Supplemental oxygen (at a flow rate of 2 L/min through a nasal cannula) was used for each patient, and the oxygen flow rate was increased when the SpO2 fell below 90%. Decline of the SpO2 by ≥4% from the baseline was defined as clinically significant.

Capnographic monitoring

For end-tidal capnographic monitoring, we used a device (Smart CapnoLine Guardian, Medtronic, Ireland) consisting of an endoscopic bite block equipped with a cannula designed to sample expired air from both the nostrils and the mouth (Fig. 1a). This was connected to an automated capnographic monitoring device (Capnostream 20P, Medtronic, Ireland) (Fig. 1b) through a sampling tube. This monitoring device can measure the concentrations of carbon dioxide in the expired air continuously. When the capnogram showed a flat line, a clinician made sure that the sample port was not disconnected. The capnographic data and SpO2 data were routinely collected and recorded in our institutional databank after the procedure. Apnea episodes were defined in this study as cessation of airflow for more than 10 s (Fig. 1c). After identifying both the time of onset and end of the apnea episodes, we calculated the duration of the apnea episodes and the time delay between the onset of an apnea episode and a ≥4% SpO2 decline from the baseline.

Data analysis

Descriptive data were expressed as numbers (percentages) and medians (ranges), and continuous data were expressed as means and standard deviations (SD) for normally distributed data, and as medians with interquartile ranges (IQR) for non-normally distributed data. Continuous data were tested for normal distribution using the Kolmogorov–Smirnov test. For statistical comparison, the descriptive data were compared using the chi-square test or Fisher’s exact test, and the continuous data were compared using the t-test for normally distributed data and the Mann-Whitney test for non-normally distributed data. All P values were two sided and the statistical significance level was set at <0.05. Data were entered into an Excel (Microsoft Corp, USA) database. All analysis and interpretations of the data were carried out using SAS, ver. 9.4 (SAS Institute Inc. USA).

Results

Of the 125 eligible patients, four patients were excluded because of missing data. After analysis of the capnographic data from the remaining 121 patients, the patients were divided into a group with apnea episodes (developing at least one apnea episode) and a group without apnea episodes during the FB procedure. There were 59 patients (40 males and 19 females) with a mean age of 71 years (range 23–82) in the group with apnea episodes and 62 patients (42 males and 20 females) with a mean age of 69 years (range 37–81) in the group without apnea episodes. As shown in Table 1, there were no significant differences in the age, gender, body mass index, ASA physical status, frequency of the comorbidities of COPD or interstitial lung disease, and the final diagnosis between the groups with and without apnea episodes. There were no patients with severe obesity or severe obstructive sleep apnea syndrome with abnormality of a neck circumference. The SpO2 was ≥96% prior to the procedure in all the patients. The mean total dose of midazolam was higher in the group with apnea episodes than in the group without apnea episodes (3.9 mg vs. 2.3 mg, P < 0.001). The median minimum SpO2 during the FB procedure was lower in the group with apnea episodes (89%; IQR 87–93 vs. 96%; IQR 92–97, P < 0.001) and the median maximum flow rate of supplemental O2 required was higher in the group with apnea episodes than in the group without apnea episodes (2 L/min; IQR 2–4 vs. 2 L/min; IQR 2-2, P < 0.001).
Table 1
Characteristics of the patient groups with and without apnea episodes (n = 121)
Variable
With apnea episodes (n = 59)
Without apnea episodes (n = 62)
P value
Age (years), median (range)
71 (23–82)
69 (37–81)
0.781
Gender (male), n (%)
40 (67.8)
42 (67.7)
0.995
BMI (kg/m2), mean ± SD
22.3 ± 2.8
21.3 ± 2.9
0.061
ASA physical status (I/II/III/IV), n
15/36/8/0
25/31/6/0
0.214
Comorbidities and diagnoses, n (%)
 COPD
1 (1.7)
4 (6.5)
0.365
 ILD
11 (18.6)
8 (12.9)
0.458
 Infectious disease
3 (5.1)
3 (4.8)
1.000
 Malignancy
41 (69.5)
39 (62.9)
0.565
 Others
12 (20.3)
11 (17.7)
0.818
Procedures, (%)
 Endobronchial biopsy
16.9
12.9
0.532
 Brushing
42.4
56.5
0.122
 TBB
54.2
64.5
0.250
 TBNA
25.4
19.4
0.423
 Washing
15.3
29.0
0.069
Baseline SpO2 a (%), mean ± SD
97.1 ± 1.0
98.0 ± 1.0
0.014
Minimum SpO2 b (%), median (IQR)
89 (87–93)
96 (92–97)
<0.001
Maximum O2 flow (L/min), median (IQR)
2 (2–4)
2 (2-2)
<0.001
Total dose of midazolam (mg), mean ± SD
3.9 ± 1.0
2.3 ± 0.8
<0.001
BMI body mass index, SD standard deviation, ASA American Society of Anesthesiologists, COPD chronic obstructive pulmonary disease, ILD interstitial lung disease, TBB transbronchial biopsy, TBNA transbronchial needle aspiration (including endobronchial ultrasound-guided aspiration), IQR interquartile range
aBefore flexible bronchoscopy in ambient air
bDuring flexible bronchoscopy under supplemental oxygen
As shown in Table 2, there were a total of 131 apnea episodes in 59 patients (48.8%). Prolong apnea episodes that lasted for more than 30 s occurred in 24 patients (19.8%). The median duration of the apnea episodes was 33 s (IQR 24–46), and the maximum duration was 97 s. A total of 55 apnea episodes (42.0%) were followed by a decline of the SpO2 by ≥4% from the baseline. The median time delay between the onset of an apnea episode and decline of the SpO2 by ≥4% from the baseline was 31 s (IQR 28–42). There were no patients who suffered from massive bleeding or pneumothorax during the FB procedures. None of the patients in this case series required assisted ventilation during/after the FB procedure.
Table 2
Apnea profile (n = 131)
Apnea episodes per patient, median (range)
2 (1–8)
Duration of the apnea episodes, median (IQR)
33 s (24–46)
 Maximum duration time of an apnea episode
97 s
Apnea episodes associated with SpO2 decline by ≥4%, n (%)
55 (42.0)
 Maximum SpO2 decline
19% in SpO2
Time delay between the onset of an apnea episode and SpO2 decline by ≥4%, median (IQR)
31 s (28–42)
IQR interquartile range, s seconds

Discussion

Our results revealed that apnea episodes occur at a high frequency during FB under sedation in the clinical setting. In addition, end-tidal capnographic monitoring also allowed earlier detection of the apnea episodes than pulse oximetry.
The present study showed that apnea episodes occurred frequently during FB procedures performed under sedation; apneas occurred in 48.8% of the patients, and especially prolonged apnea episodes, lasting for over 30 s, occurred in 19.8% of the patients. Moreover, as much as 42.0% of the apnea episodes were followed by significant oxygen desaturation. Previous reports may lend support to our results; in the prospective study of 50 patients undergoing colonoscopy under sedation, a total of 29 episodes of anomalous ventilation, including apnea episodes lasting for more than 30 s, were detected in 16 patients by capnographic monitoring [5]. The results of a nationwide survey reported recently from Switzerland showed that apnea episodes requiring bag ventilation occurred at a rate of 0.011% during FB under sedation [6]. However, the results of the end-tidal capnographic monitoring in our present study revealed the occurrence of a number of additional apnea episodes besides those necessitating assisted ventilation. This implies that unintended oversedation occurs in many patients sedated with midazolam in the clinical setting, even though clinicians try to titrate the level of sedation to “moderate” sedation. Moreover, the dose of midazolam used in this study might have been lower than the average dose used at other institutions. A higher number and longer length of apnea episodes can be identified by capnography in patients administered higher doses of midazolam or propofol. Therefore, we suggest that it is necessary to carry out respiratory monitoring during FB under sedation.
This study also showed that end-tidal capnographic monitoring allowed earlier detection of the apnea episodes, not actual measurement values of carbon dioxide, than pulse oximetry. It has been reported that SpO2 decline to its nadir can be delayed by 45 to 60 s after an apnea episode in patients with obstructive sleep apnea syndrome [7]. Our study showed that the median time delay between the onset of an apnea episode and significant SpO2 decline was 31 s. This suggests that we can recognize apnea episodes about 30 s earlier by capnographic monitoring than by pulse oximetry alone. This result has a very important implication in relation to the usefulness of capnographic monitoring; end-tidal capnography alerts us of apnea episodes by setting off an alarm and by way of graphics, as shown in Fig. 1c, which allows us to detect apnea episodes early and to promptly implement appropriate corrective measures, such as patient stimulation or oxygen supplementation, before the respiratory depression becomes clinically significant. Furthermore, inappropriate addition of sedatives can also be avoided by early recognition of apnea episodes. Although pulse oximetry is important to evaluate the oxygenation state of a patient and is routinely used for monitoring of respiratory functions during FB [2], it has its limitations. Pulse oximetry can be a delayed indicator of respiratory depression [8]. Especially in sedated patients receiving supplemental oxygen, the decline in the SpO2 may be delayed even in the presence of severe respiratory insufficiency [9, 10]. Therefore, we need an additional method for the early detection of respiratory depression. End-tidal capnography is a non-invasive method that allows continuous monitoring of ventilation. Although several studies of end-tidal capnographic monitoring during gastrointestinal endoscopy have been conducted, the conclusions remain controversial because of wide differences in the study settings (e.g. in relation to the patients’ backgrounds, the type of sedative used, the primary outcome measure, etc.) [1113]. To investigate the usefulness of end-tidal capnography during FB, prospective comparative trials are warranted in the future.
Various methods for early detection of respiratory depression have been described so far. Monitoring of the chest wall impedance is the most commonly used monitoring method in clinical practice, and recently, the use of acoustic monitoring has also become popular in some countries. However, many factors, including motion artifacts and physiological events unrelated to respiration, such as coughing and swallowing, may generate a high number of false alarms due to inaccurate readings when these two devices are used [1416]. Moreover, chest wall impedance monitoring may fail to detect apneas secondary to airway obstruction [17]. A previous study demonstrated that transcutaneous capnography is an effective tool for monitoring ventilation during FB [18, 19]. Cutaneous carbon dioxide tension measured with a digital sensor has been reported to show a good correlation with the arterial carbon dioxide concentration. Therefore, currently, end-tidal or transcutaneous capnographic monitoring may be the most reliable for sensitive detection of respiratory depression. However, as there have been no comparative studies to determine the best method for respiratory monitoring, further investigations are awaited.
We need to discuss some limitations of our study here. First, it is possible that flat lines on the capnogram were caused by events other than true apnea episodes. Although we checked for displacement of the sampling tube, we did not record events of continuous suctionings of the airway that may cause a cessation of the waveform on the capnogram. Second, we have to consider multiple causes of SpO2 decline during FB under sedation. SpO2 decline can also be caused by conditions such as mucus obstruction of the airways, bronchial bleeding, or pneumothorax. However, there were no cases of massive bleeding or pneumothorax in this case series, and there were no patients who underwent bronchoalveolar lavage. Therefore, most of the SpO2 declines are presumed to have been associated with apneic episodes in our cases.

Conclusions

End-tidal capnography revealed the occurrence of apnea episodes at a high frequency during FB under sedation. End-tidal capnographic monitoring also allowed earlier detection of the apnea episodes than pulse oximetry. We suggest the possible necessity of respiratory monitoring during FB in the clinical setting.

Acknowledgements

Not applicable.

Funding

There was no funding of this study.

Availability of data and materials

Not applicable.

Authors’ contributions

All authors had access to the data. TI and MF participated in the design of the study. TI did performed the statistical analysis and wrote the first draft of the manuscript. KenjiT edited the draft. KenjiT and KoichiroT provided intellectual input. TI, KS, KH, MA, NK and JT performed bronchoscopy and participated in patient care. All authors read and approved the final manuscript.

Competing interests

The authors declare that they have no competing interests.
Not applicable.
The Institutional Review Board of Chiba University approved this study (Chiba #2455) without the need to obtain informed consent.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.
Literatur
1.
Zurück zum Zitat The American Society of Anesthesiologists Task Force on Sedation and Analgesia by Non-anesthesiologists. Practice guidelines for sedation and analgesia by non-anesthesiologists. Anesthesiology. 2002;96(4):1004–17.CrossRef The American Society of Anesthesiologists Task Force on Sedation and Analgesia by Non-anesthesiologists. Practice guidelines for sedation and analgesia by non-anesthesiologists. Anesthesiology. 2002;96(4):1004–17.CrossRef
2.
Zurück zum Zitat Forster A, Gardaz JP, Suter PM, Gemperle M. Respiratory depression by midazolam and diazepam. Anesthesiology. 1980;53(6):494–7.CrossRefPubMed Forster A, Gardaz JP, Suter PM, Gemperle M. Respiratory depression by midazolam and diazepam. Anesthesiology. 1980;53(6):494–7.CrossRefPubMed
3.
Zurück zum Zitat Abdelmalak BB, Wang J, Mehta AC. Capnography monitoring in procedural sedation for bronchoscopy. J Bronchology Interv Pulmonol. 2014;21(4):370–1.CrossRefPubMed Abdelmalak BB, Wang J, Mehta AC. Capnography monitoring in procedural sedation for bronchoscopy. J Bronchology Interv Pulmonol. 2014;21(4):370–1.CrossRefPubMed
5.
Zurück zum Zitat Cacho G, Perez-Calle JL, Barbado A, Lledo JL, Ojea R, Fernandez-Rodriguez CM. Capnography is superior to pulse oximetry for the detection of respiratory depression during colonoscopy. Rev Esp Enferm Dig. 2010;102(2):86–9.CrossRefPubMed Cacho G, Perez-Calle JL, Barbado A, Lledo JL, Ojea R, Fernandez-Rodriguez CM. Capnography is superior to pulse oximetry for the detection of respiratory depression during colonoscopy. Rev Esp Enferm Dig. 2010;102(2):86–9.CrossRefPubMed
6.
Zurück zum Zitat Gaisl T, Bratton DJ, Heuss LT, Kohler M, Schlatzer C, Zalunardo MP, Frey M, Franzen D. Sedation during bronchoscopy: data from a nationwide sedation and monitoring survey. BMC Pulm Med. 2016;16(1):113.CrossRefPubMedPubMedCentral Gaisl T, Bratton DJ, Heuss LT, Kohler M, Schlatzer C, Zalunardo MP, Frey M, Franzen D. Sedation during bronchoscopy: data from a nationwide sedation and monitoring survey. BMC Pulm Med. 2016;16(1):113.CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Netzer N, Eliasson AH, Netzer C, Kristo DA. Overnight pulse oximetry for sleep-disordered breathing in adults: a review. Chest. 2001;120(2):625–33.CrossRefPubMed Netzer N, Eliasson AH, Netzer C, Kristo DA. Overnight pulse oximetry for sleep-disordered breathing in adults: a review. Chest. 2001;120(2):625–33.CrossRefPubMed
8.
Zurück zum Zitat Vargo JJ, Zuccaro Jr G, Dumot JA, Conwell DL, Morrow JB, Shay SS. Automated graphic assessment of respiratory activity is superior to pulse oximetry and visual assessment for the detection of early respiratory depression during therapeutic upper endoscopy. Gastrointest Endosc. 2002;55(7):826–31.CrossRefPubMed Vargo JJ, Zuccaro Jr G, Dumot JA, Conwell DL, Morrow JB, Shay SS. Automated graphic assessment of respiratory activity is superior to pulse oximetry and visual assessment for the detection of early respiratory depression during therapeutic upper endoscopy. Gastrointest Endosc. 2002;55(7):826–31.CrossRefPubMed
9.
Zurück zum Zitat Fu ES, Downs JB, Schweiger JW, Miguel RV, Smith RA. Supplemental oxygen impairs detection of hypoventilation by pulse oximetry. Chest. 2004;126(5):1552–8.CrossRefPubMed Fu ES, Downs JB, Schweiger JW, Miguel RV, Smith RA. Supplemental oxygen impairs detection of hypoventilation by pulse oximetry. Chest. 2004;126(5):1552–8.CrossRefPubMed
10.
Zurück zum Zitat Keidan I, Gravenstein D, Berkenstadt H, Ziv A, Shavit I, Sidi A. Supplemental oxygen compromises the use of pulse oximetry for detection of apnea and hypoventilation during sedation in simulated pediatric patients. Pediatrics. 2008;122(2):293–8.CrossRefPubMed Keidan I, Gravenstein D, Berkenstadt H, Ziv A, Shavit I, Sidi A. Supplemental oxygen compromises the use of pulse oximetry for detection of apnea and hypoventilation during sedation in simulated pediatric patients. Pediatrics. 2008;122(2):293–8.CrossRefPubMed
11.
Zurück zum Zitat Koniaris LG, Wilson S, Drugas G, Simmons W. Capnographic monitoring of ventilatory status during moderate (conscious) sedation. Surg Endosc. 2003;17(8):1261–5.CrossRefPubMed Koniaris LG, Wilson S, Drugas G, Simmons W. Capnographic monitoring of ventilatory status during moderate (conscious) sedation. Surg Endosc. 2003;17(8):1261–5.CrossRefPubMed
12.
Zurück zum Zitat Beitz A, Riphaus A, Meining A, Kronshage T, Geist C, Wagenpfeil S, Weber A, Jung A, Bajbouj M, Pox C, Schneider G, Schmid RM, Wehrmann T, von Delius S. Capnographic monitoring reduces the incidence of arterial oxygen desaturation and hypoxemia during propofol sedation for colonoscopy: a randomized, controlled study (ColoCap Study). Am J Gastroenterol. 2012;107(8):1205–12.CrossRefPubMed Beitz A, Riphaus A, Meining A, Kronshage T, Geist C, Wagenpfeil S, Weber A, Jung A, Bajbouj M, Pox C, Schneider G, Schmid RM, Wehrmann T, von Delius S. Capnographic monitoring reduces the incidence of arterial oxygen desaturation and hypoxemia during propofol sedation for colonoscopy: a randomized, controlled study (ColoCap Study). Am J Gastroenterol. 2012;107(8):1205–12.CrossRefPubMed
13.
Zurück zum Zitat Qadeer MA, Vargo JJ, Dumot JA, Lopez R, Trolli PA, Stevens T, Parsi MA, Sanaka MR, Zuccaro G. Capnographic monitoring of respiratory activity improves safety of sedation for endoscopic cholangiopancreatography and ultrasonography. Gastroenterology. 2009;136(5):1568–76.CrossRefPubMed Qadeer MA, Vargo JJ, Dumot JA, Lopez R, Trolli PA, Stevens T, Parsi MA, Sanaka MR, Zuccaro G. Capnographic monitoring of respiratory activity improves safety of sedation for endoscopic cholangiopancreatography and ultrasonography. Gastroenterology. 2009;136(5):1568–76.CrossRefPubMed
14.
Zurück zum Zitat Gaucher A, Frasca D, Mimoz O, Debaene B. Accuracy of respiratory rate monitoring by capnometry using the Capnomask(R) in extubated patients receiving supplemental oxygen after surgery. Br J Anaesth. 2012;108:316–20.CrossRefPubMed Gaucher A, Frasca D, Mimoz O, Debaene B. Accuracy of respiratory rate monitoring by capnometry using the Capnomask(R) in extubated patients receiving supplemental oxygen after surgery. Br J Anaesth. 2012;108:316–20.CrossRefPubMed
15.
Zurück zum Zitat Mimoz O, Benard T, Gaucher A, Frasca D, Debaene B. Accuracy of respiratory rate monitoring using a non-invasive acoustic method after general anaesthesia. Br J Anaesth. 2012;108:872–5.CrossRefPubMed Mimoz O, Benard T, Gaucher A, Frasca D, Debaene B. Accuracy of respiratory rate monitoring using a non-invasive acoustic method after general anaesthesia. Br J Anaesth. 2012;108:872–5.CrossRefPubMed
16.
Zurück zum Zitat Ramsay MA, Usman M, Lagow E, Mendoza M, Untalan E, De Vol E. The accuracy, precision and reliability of measuring ventilatory rate and detecting ventilatory pause by rainbow acoustic monitoring and capnometry. Anesth Analg. 2013;117:69–75.CrossRefPubMed Ramsay MA, Usman M, Lagow E, Mendoza M, Untalan E, De Vol E. The accuracy, precision and reliability of measuring ventilatory rate and detecting ventilatory pause by rainbow acoustic monitoring and capnometry. Anesth Analg. 2013;117:69–75.CrossRefPubMed
17.
Zurück zum Zitat Wilkinson JN, Thanawala VU. Thoracic impedance monitoring of respiratory rate during sedation--is it safe? Anaesthesia. 2009;64:455–6.CrossRefPubMed Wilkinson JN, Thanawala VU. Thoracic impedance monitoring of respiratory rate during sedation--is it safe? Anaesthesia. 2009;64:455–6.CrossRefPubMed
18.
Zurück zum Zitat Chhajed PN, Rajasekaran R, Kaegi B, Chhajed TP, Pflimlin E, Leuppi J, Tamm M. Measurement of combined oximetry and cutaneous capnography during flexible bronchoscopy. Eur Respir J. 2006;28:386–90.CrossRefPubMed Chhajed PN, Rajasekaran R, Kaegi B, Chhajed TP, Pflimlin E, Leuppi J, Tamm M. Measurement of combined oximetry and cutaneous capnography during flexible bronchoscopy. Eur Respir J. 2006;28:386–90.CrossRefPubMed
19.
Zurück zum Zitat Dreher M, Ekkernkamp E, Storre JH, Kabitz HJ, Windisch W. Sedation during flexible bronchoscopy in patients with pre-existing respiratory failure: Midazolam versus Midazolam plus Alfentanil. Respiration. 2010;79(4):307–14.CrossRefPubMed Dreher M, Ekkernkamp E, Storre JH, Kabitz HJ, Windisch W. Sedation during flexible bronchoscopy in patients with pre-existing respiratory failure: Midazolam versus Midazolam plus Alfentanil. Respiration. 2010;79(4):307–14.CrossRefPubMed
Metadaten
Titel
End-tidal capnographic monitoring to detect apnea episodes during flexible bronchoscopy under sedation
verfasst von
Tsukasa Ishiwata
Kenji Tsushima
Mai Fujie
Kenichi Suzuki
Kosuke Hirota
Mitsuhiro Abe
Naoko Kawata
Jiro Terada
Koichiro Tatsumi
Publikationsdatum
01.12.2017
Verlag
BioMed Central
Erschienen in
BMC Pulmonary Medicine / Ausgabe 1/2017
Elektronische ISSN: 1471-2466
DOI
https://doi.org/10.1186/s12890-016-0361-7

Weitere Artikel der Ausgabe 1/2017

BMC Pulmonary Medicine 1/2017 Zur Ausgabe

Leitlinien kompakt für die Innere Medizin

Mit medbee Pocketcards sicher entscheiden.

Seit 2022 gehört die medbee GmbH zum Springer Medizin Verlag

Update Innere Medizin

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.