Open Access 01.12.2015 | Editorial

Passive leg raising: five rules, not a drop of fluid!

verfasst von: Xavier Monnet, Jean-Louis Teboul

Erschienen in: Critical Care | Ausgabe 1/2015

download
DOWNLOAD
print
DRUCKEN
insite
SUCHEN
Hinweise
A comment to this article is available at http://​dx.​doi.​org/​10.​1186/​s13054-015-0955-0.

Competing interests

XM and J-LT are members of the medical advisory board of Pulsion Medical Systems (Feldkirchen, Germany). As consultants for this company, they have received honoraria. The company did not provide funding for the preparation of this manuscript.
Abkürzungen
PLR
Passive leg raising
In acute circulatory failure, passive leg raising (PLR) is a test that predicts whether cardiac output will increase with volume expansion [1]. By transferring a volume of around 300 mL of venous blood [2] from the lower body toward the right heart, PLR mimics a fluid challenge. However, no fluid is infused and the hemodynamic effects are rapidly reversible [1,3], thereby avoiding the risks of fluid overload. This test has the advantage of remaining reliable in conditions in which indices of fluid responsiveness that are based on the respiratory variations of stroke volume cannot be used [1], like spontaneous breathing, arrhythmias, low tidal volume ventilation, and low lung compliance.
The method for performing PLR is of the utmost importance because it fundamentally affects its hemodynamic effects and reliability. In practice, five rules should be followed.
First, PLR should start from the semi-recumbent and not the supine position (Figure 1). Adding trunk lowering to leg raising should mobilize venous blood from the large splanchnic compartment, thus magnifying the increasing effects of leg elevation on cardiac preload [2] and increasing the test’s sensitivity. A study that did not comply with this rule misleadingly reported a poor reliability of PLR [4].
Second, the PLR effects must be assessed by a direct measurement of cardiac output and not by the simple measurement of blood pressure. Indeed, reliability of PLR is poorer when assessed by using arterial pulse pressure compared with cardiac output [1,5]. Although the peripheral arterial pulse pressure is positively correlated with stroke volume, it also depends on arterial compliance and pulse wave amplification. The latter phenomenon could be altered during PLR, impeding the use of pulse pressure as a surrogate of stroke volume to assess PLR effects.
Third, the technique used to measure cardiac output during PLR must be able to detect short-term and transient changes since the PLR effects may vanish after 1 minute [1]. Techniques monitoring cardiac output in ‘real time’, such as arterial pulse contour analysis, echocardiography, esophageal Doppler, or contour analysis of the volume clamp-derived arterial pressure, can be used [6]. Conflicting results have been reported for bioreactance [7,8]. The hemodynamic response to PLR can even be assessed by the changes in end-tidal exhaled carbon dioxide, which reflect the changes in cardiac output in the case of constant minute ventilation [5].
Fourth, cardiac output must be measured not only before and during PLR but also after PLR when the patient has been moved back to the semi-recumbent position, in order to check that it returns to its baseline (Figure 1). Indeed, in unstable patients, cardiac output changes during PLR could result from spontaneous variations inherent to the disease and not from cardiac preload changes.
Fifth, pain, cough, discomfort, and awakening could provoke adrenergic stimulation, resulting in mistaken interpretation of cardiac output changes. Some simple precautions must be taken to avoid these confounding factors (Figure 1). PLR must be performed by adjusting the bed and not by manually raising the patient’s legs. Bronchial secretions must be carefully aspirated before PLR. If awake, the patient should be informed of what the test involves. A misleading sympathetic stimulation can be suspected if PLR is accompanied by a significant increase in heart rate, which normally should not occur.
It has been suggested that PLR is unreliable in the case of intra-abdominal hypertension [9]. The increased abdominal weight was hypothesized to squeeze the inferior vena cava in the raised-leg position [10]. Nevertheless, the single study investigating this issue did not confirm the hypothesis since intra-abdominal pressure was not measured during PLR [9]. Furthermore, one could hypothesize that PLR reduces rather than increases the intra-abdominal pressure by relieving the weight of the diaphragm on the abdominal cavity.
Provided that these simple rules are followed, the PLR test reliably predicts preload responsiveness [11]. Because it has no side effects, PLR should be considered as a replacement for the classic fluid challenge [12]. The main drawback of the fluid challenge is that, if it is negative, fluid has nonetheless been irreversibly administered to the patient. Repeated fluid challenges therefore can lead to fluid overload. In this regard, PLR is an attractive method of challenging preload without administering one drop of fluid. Importantly, it should be remembered that detection of preload responsiveness by a positive PLR test should not routinely lead to fluid administration. Indeed, the decision to administer fluid must always be made individually on the basis of the mandatory presence of the three following situations: hemodynamic instability or signs of circulatory shock (or both), preload responsiveness (positive PLR test), and limited risks of fluid overload. Also, a negative PLR test should contribute mainly to the decision to stop or discontinue fluid infusion, in order to avoid fluid overload, suggesting that hemodynamic instability should be corrected by means other than fluid administration.
This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.

Competing interests

XM and J-LT are members of the medical advisory board of Pulsion Medical Systems (Feldkirchen, Germany). As consultants for this company, they have received honoraria. The company did not provide funding for the preparation of this manuscript.
download
DOWNLOAD
print
DRUCKEN
Literatur
1.
Zurück zum Zitat Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul JL: Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med 2006, 34:1402–1407.CrossRef Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul JL: Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med 2006, 34:1402–1407.CrossRef
2.
Zurück zum Zitat Jabot J, Teboul JL, Richard C, Monnet X: Passive leg raising for predicting fluid responsiveness: importance of the postural change. Intensive Care Med 2009, 35:85–90.CrossRef Jabot J, Teboul JL, Richard C, Monnet X: Passive leg raising for predicting fluid responsiveness: importance of the postural change. Intensive Care Med 2009, 35:85–90.CrossRef
3.
Zurück zum Zitat Boulain T, Achard JM, Teboul JL, Richard C, Perrotin D, Ginies G: Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients. Chest 2002, 121:1245–1252.CrossRef Boulain T, Achard JM, Teboul JL, Richard C, Perrotin D, Ginies G: Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients. Chest 2002, 121:1245–1252.CrossRef
4.
Zurück zum Zitat Lakhal K, Ehrmann S, Runge I, Benzekri-Lefevre D, Legras A, Dequin PF, Mercier E, Wolff M, Regnier B, Boulain T: Central venous pressure measurements improve the accuracy of leg raising-induced change in pulse pressure to predict fluid responsiveness. Intensive Care Med 2010, 36:940–948.CrossRef Lakhal K, Ehrmann S, Runge I, Benzekri-Lefevre D, Legras A, Dequin PF, Mercier E, Wolff M, Regnier B, Boulain T: Central venous pressure measurements improve the accuracy of leg raising-induced change in pulse pressure to predict fluid responsiveness. Intensive Care Med 2010, 36:940–948.CrossRef
5.
Zurück zum Zitat Monnet X, Bataille A, Magalhaes E, Barrois J, Le Corre M, Gosset C, Guerin L, Richard C, Teboul JL: End-tidal carbon dioxide is better than arterial pressure for predicting volume responsiveness by the passive leg raising test. Intensive Care Med 2013, 39:93–100.CrossRef Monnet X, Bataille A, Magalhaes E, Barrois J, Le Corre M, Gosset C, Guerin L, Richard C, Teboul JL: End-tidal carbon dioxide is better than arterial pressure for predicting volume responsiveness by the passive leg raising test. Intensive Care Med 2013, 39:93–100.CrossRef
6.
Zurück zum Zitat Bubenek-Turconi SI, Craciun M, Miclea I, Perel A: Noninvasive continuous cardiac output by the Nexfin before and after preload-modifying maneuvers: a comparison with intermittent thermodilution cardiac output. Anesth Analg 2013, 117:366–372.CrossRef Bubenek-Turconi SI, Craciun M, Miclea I, Perel A: Noninvasive continuous cardiac output by the Nexfin before and after preload-modifying maneuvers: a comparison with intermittent thermodilution cardiac output. Anesth Analg 2013, 117:366–372.CrossRef
7.
Zurück zum Zitat Marik PE, Levitov A, Young A, Andrews L: The use of bioreactance and carotid Doppler to determine volume responsiveness and blood flow redistribution following passive leg raising in hemodynamically unstable patients. Chest 2013, 143:364–370.CrossRef Marik PE, Levitov A, Young A, Andrews L: The use of bioreactance and carotid Doppler to determine volume responsiveness and blood flow redistribution following passive leg raising in hemodynamically unstable patients. Chest 2013, 143:364–370.CrossRef
8.
Zurück zum Zitat Kupersztych-Hagege E, Teboul JL, Artigas A, Talbot A, Sabatier C, Richard C, Monnet X: Bioreactance is not reliable for estimating cardiac output and the effects of passive leg raising in critically ill patients. Br J Anaesth 2013, 111:961–966.CrossRef Kupersztych-Hagege E, Teboul JL, Artigas A, Talbot A, Sabatier C, Richard C, Monnet X: Bioreactance is not reliable for estimating cardiac output and the effects of passive leg raising in critically ill patients. Br J Anaesth 2013, 111:961–966.CrossRef
9.
Zurück zum Zitat Mahjoub Y, Touzeau J, Airapetian N, Lorne E, Hijazi M, Zogheib E, Tinturier F, Slama M, Dupont H: The passive leg-raising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension. Crit Care Med 2010, 38:1824–1829.CrossRef Mahjoub Y, Touzeau J, Airapetian N, Lorne E, Hijazi M, Zogheib E, Tinturier F, Slama M, Dupont H: The passive leg-raising maneuver cannot accurately predict fluid responsiveness in patients with intra-abdominal hypertension. Crit Care Med 2010, 38:1824–1829.CrossRef
10.
Zurück zum Zitat Malbrain ML, Reuter DA: Assessing fluid responsiveness with the passive leg raising maneuver in patients with increased intra-abdominal pressure: be aware that not all blood returns! Crit Care Med 2010, 38:1912–1915.CrossRef Malbrain ML, Reuter DA: Assessing fluid responsiveness with the passive leg raising maneuver in patients with increased intra-abdominal pressure: be aware that not all blood returns! Crit Care Med 2010, 38:1912–1915.CrossRef
11.
Zurück zum Zitat Cavallaro F, Sandroni C, Marano C, La Torre G, Mannocci A, De Waure C, Bello G, Maviglia R, Antonelli M: Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med 2010, 36:1475–1483.CrossRef Cavallaro F, Sandroni C, Marano C, La Torre G, Mannocci A, De Waure C, Bello G, Maviglia R, Antonelli M: Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med 2010, 36:1475–1483.CrossRef
12.
Zurück zum Zitat Vincent JL, Weil MH: Fluid challenge revisited. Crit Care Med 2006, 34:1333–1337.CrossRef Vincent JL, Weil MH: Fluid challenge revisited. Crit Care Med 2006, 34:1333–1337.CrossRef
Metadaten
Titel
Passive leg raising: five rules, not a drop of fluid!
verfasst von
Xavier Monnet
Jean-Louis Teboul
Publikationsdatum
01.12.2015
Verlag
BioMed Central
Erschienen in
Critical Care / Ausgabe 1/2015
Elektronische ISSN: 1364-8535
DOI
https://doi.org/10.1186/s13054-014-0708-5

Weitere Artikel der Ausgabe 1/2015

Critical Care 1/2015 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.