Fluid responsiveness predicted by transcutaneous partial pressure of oxygen in patients with circulatory failure: a prospective study

verfasst von: Jingyuan Xu, Xiao Peng, Chun Pan, Shixia Cai, Xiwen Zhang, Ming Xue, Yi Yang, Haibo Qiu

Erschienen in: Annals of Intensive Care | Ausgabe 1/2017

Abstract

Background

Significant effort has been devoted to defining parameters for predicting fluid responsiveness. Our goal was to study the feasibility of predicting fluid responsiveness by transcutaneous partial pressure of oxygen (PtcO2) in the critically ill patients.

Methods

This was a single-center prospective study conducted in the intensive care unit of a tertiary care teaching hospital. Shock patients who presented with at least one clinical sign of inadequate tissue perfusion, defined as systolic blood pressure <90 mmHg or a decrease >40 mmHg in previously hypertensive patients or the need for vasopressive drugs; urine output <0.5 ml/kg/h for 2 h; tachycardia; lactate >4 mmol/l, for less than 24 h in the absence of a contraindication for fluids were eligible to participate in the study. PtcO2 was continuously recorded before and during a passive leg raising (PLR) test, and then before and after a 250 ml rapid saline infusion in 10 min. Fluid responsiveness is defined as a change in the stroke volume ≥10% after 250 ml of volume infusion.

Results

Thirty-four patients were included, and 14 responded to volume expansion. In the responders, the mean arterial pressure, central venous pressure, cardiac output, stroke volume and PtcO2 increased significantly, while the heart rate decreased significantly by both PLR and volume expansion. Changes in the stroke volume induced either by PLR or volume expansion were significantly greater in responders than in non-responders. The correlation between the changes in PtcO2 and stroke volume induced by volume expansion was significant. Volume expansion induced an increase in the PtcO2 of 14% and PLR induced an increase in PtcO2 of 13% predicted fluid responsiveness.

Conclusions

This study suggested the changes in PtcO2 induced by volume expansion and a PLR test predicted fluid responsiveness in critically ill patients.
Trial registration NCT02083757.
Hinweise

Electronic supplementary material

The online version of this article (doi:10.​1186/​s13613-017-0279-0) contains supplementary material, which is available to authorized users.
Abkürzungen
APACHE II
acute physiology and chronic health evaluation II
AUC
area under the receiver-operating characteristic curve
PaCO2
arterial partial pressure of carbon dioxide
PaO2
arterial partial pressure of oxygen
PLR
passive leg raising
PtcO2
transcutaneous partial pressure of oxygen
ROC
receiver operator characteristic
SaO2
arterial hemoglobin saturation
ScvO2
central venous oxygen saturation
SD
standard deviation
IQR
interquartile range

Background

The clinical determination of fluid resuscitation can be extremely difficult in critically ill patients. Although hemodynamic maximization is favored, this approach is connected to a risk of fluid overload and heart failure. Therefore, fluid optimization is proposed to benefit patients and decrease complications. As the most common approach in the clinical settings, fluid responsiveness prediction is used to evaluate fluid optimization based on the heart working on the ascending limb of the Starling curve. The gold standard of fluid responsiveness is defined as a change in the cardiac output or stroke volume ≥10–15% after rapid volume infusion of 250 ml [1].
Significant effort has been devoted to defining and developing methods for predicting fluid responsiveness, i.e., whether the patient will benefit from fluid administration. The most common and easy approach is the passive leg raising (PLR) test which transfers blood from the leg and abdominal compartments via a postural change [2, 3].
However, the parameters measured when performing the PLR test or volume expansion are invasive and time-consuming. In considering noninvasive measurements that monitor cardiovascular function and cell oxygenation might be the future of critical care [4], a completely noninvasive, atraumatic and continuous parameter to predict fluid responsiveness, especially whether the patient could benefit from fluid resuscitation, is urgently needed [5]. The transcutaneous partial pressure of oxygen (PtcO2), a noninvasive measure to detect tissue ischemia or inadequate perfusion [69], might predict fluid responsiveness. The purpose of this study was to (1) determine whether the changes in PtcO2 observed during volume expansion and passive leg raising can track simultaneous changes in the stroke volume, and (2) study the feasibility of predicting fluid responsiveness by PtcO2 during volume expansion and PLR in critically ill patients.

Methods

Setting

This was a single-center, prospective study conducted in the intensive care unit of a tertiary care teaching hospital. The study protocol was approved by the Ethics Committee of Zhongda Hospital, School of Medicine, Southeast University, and informed consent was given by each patient or their next of kin. Trial registration: Clinicaltrials.gov NCT02083757. Registered 07 March 2014.

Study population

Shock patients who presented with at least one clinical sign of inadequate tissue perfusion for less than 24 h in the absence of a contraindication for fluids were eligible to participate in the study. Clinical signs of inadequate tissue perfusion were defined as systolic blood pressure <90 mmHg or a decrease >40 mmHg in previously hypertensive patients or the need for vasopressive drugs; urine output <0.5 ml/kg/h for two hours; tachycardia; lactate >4 mmol/l.
Patients who were pregnant, younger than 18 years of age, had a contraindication to the passive leg raising test, had cardiac arrhythmias, had abdominal compartment syndrome or refused to participate in the study were excluded.

Interventions

All patients received infusions of morphine and propofol for anesthesia and sedation as well as had an arterial catheter and central venous catheter in place. Serial measurements of the heart rate, mean arterial pressure and central venous pressure were performed. Arterial and central venous gases were obtained to determine the pH, arterial partial pressure of oxygen (PaO2), arterial partial pressure of carbon dioxide (PaCO2), arterial hemoglobin saturation (SaO2), hemoglobin, central venous oxygen saturation (ScvO2) and lactate concentration. The PtcO2 and transcutaneous partial pressure of carbon dioxide (PtcCO2) were measured by TCM (TCM 4, Radiometer Copenhagen, Denmark). After an initial calibration, the sensor was placed at the chest and heated to 44 °C. Noninvasive bioreactance stroke volume monitoring was obtained using the NICOM system (Cheetah Medical, Portland, OR) with four double-electrode stickers placed on the chest wall.
The study started when patients were sedated with a constant value of the stroke volume in semi-recumbent position for 10 min and the first set of hemodynamic measurements was recorded, including the heart rate, systemic arterial pressure, diastolic arterial pressure, mean arterial pressure, central venous pressure, stroke volume, PtcO2 and PtcCO2. Then, a PLR test was performed by changing the bed from 45° head-up to a flat position with legs elevated to 45° without changing the hip angle. When PLR induced the maximal effect on the stroke volume, hemodynamic measurements were recorded again. Then, the patient was moved back to the semi-recumbent position for 20 min and another hemodynamic measurement was performed. After volume expansion by rapid infusion of 250 ml of normal saline for 10 min [10], hemodynamic measurement was performed again. During the study time, no other change in treatment was allowed.

Statistical analysis

Fluid responsiveness is defined as a change in the stroke volume ≥10% after 250 ml of rapid saline infusion in 10 min. Patients with fluid responsiveness were defined as fluid responders, and the remaining patients were defined as fluid non-responders.
Statistical analysis of the data was performed using SPSS 16.0 (IBM, Somers, NY). Data are presented as the mean ± standard deviation (SD) if normally distributed (Kolmogorov–Smirnov test) or as median (25–75% interquartile range, IQR). Categorical variables are presented as the number and percentage. For comparison of values between different study times, the paired Student’s t test or Wilcoxon test was performed when appropriate. For the comparison between responders and non-responders, the Mann–Whitney U test or two-tailed Student’s t test was performed when appropriate. Differences were considered significant at p < 0.05.
Receiver operator characteristic (ROC) curves were constructed to detect the ability of PtcO2 to predict fluid responsiveness. When the area under the ROC curve (AUC) was greater than 0.5, the best cutoff value was defined by the value closest to the Youden index.

Results

Clinical characteristics of the study subjects

Thirty-four adult patients with circulatory failure for less than 24 h were included in the study. Patients were treated according to standard protocols, and no extra interventions were performed during the study. The patients’ characteristics are detailed in Table 1. The final pool of patients included 21 men and 13 women who were 71 ± 14 years old. The averaged APACHE II score was 19. Septic and hypovolemic shock are the most common types of shock. Sixty-five percent of patients were receiving norepinephrine, and 85 percent of patients were ventilated. The ICU stay was 10 (4–14) days and in-hospital mortality was 44%. Between responders and non-responders, no significant differences were found in the duration of shock prior to study inclusion, patients receiving norepinephrine and mechanical ventilation, baseline lactate, PtcO2 and PtcCO2.
Table 1
Characteristics of patients. *p < 0.05 versus responder
 
All patients (n = 34)
Responder (n = 14)
Non-responder (n = 20)
p value
Age (mean ± SD, years)
71 ± 14
72 ± 14
71 ± 15
0.89
Gender (male/female, no. of patients)
21/13
7/7
14/6
 
Patients sources
 Emergency department
12
5
7
 
 Surgical department
19
8
11
 
 Internal medicine
3
1
2
 
APACHE II score
19 ± 7
19 ± 5
21 ± 7
0.53
Type of shock (no. of patients)
 Septic
22
9
13
 
 Hypovolemic
10
5
5
 
 Obstructive
1
0
1
 
 Cardiogenic
0
0
0
 
 Neurogenic
1
0
1
 
Duration of shock prior to study inclusion (h)
13 ± 7
12 ± 7
14 ± 6
0.25
Patients receiving norepinephrine (no. of patients, %)
22 (65%)
10 (71%)
12 (60%)
0.53
Mechanical ventilation, n (%)
29 (85%)
13 (93%)
16 (80%)
0.38
Blood gas analysis
 pH
7.42 ± 0.07
7.45 ± 0.06
7.39 ± 0.07
0.19
 PaO2 (mean ± SD, mmHg)
159 ± 43
159 ± 47
159 ± 42
0.96
 PaCO2 (mean ± SD, mmHg)
29 ± 5
29 ± 6
29 ± 5
0.86
 Hemoglobin (mean ± SD, g/l)
9.4 ± 1.7
9.2 ± 1.7
9.5 ± 1.7
0.73
 FiO2 (%)
48 ± 7
47 ± 5
50 ± 8
0.23
 ScvO2 (mean ± SD, %)
82 ± 6
81 ± 5
83 ± 6
0.35
 Lactate (25–75% interquartile range, mmol/L)
1.0 (0.7–2.0)
0.9 (0.7–1.8)
0.9 (0.7–1.5)
0.64
PtcO2 (mean ± SD, mmHg)
106 ± 38
92 ± 37
114 ± 37
0.11
PtcCO2 (mean ± SD, mmHg)
41 ± 11
39 ± 8
42 ± 13
0.57
ICU stay (25–75% interquartile range, day)
10 (4–14)
7 (4–13)
10 (5–16)
0.75
In-hospital mortality, n (%)
15 (44%)
7 (50%)
8 (40%)
0.64
SD, standard deviation; APACHE II, acute physiology and chronic health evaluation II; PaO2, arterial oxygen partial pressure; PaCO2, arterial carbon dioxide partial pressure; FiO2, fraction of inspiration oxygen; SaO2, arterial hemoglobin saturation; ScvO2, central venous oxygen saturation; PtcO2, transcutaneous partial pressure of oxygen; PtcCO2, transcutaneous partial pressure of carbon dioxide

Effect on transcutaneous partial pressure of oxygen (PtcO2)

Changes in the heart rate, mean arterial pressure, central venous pressure, cardiac output, cardiac index, stroke volume, stroke volume index, PtcO2 and PtcCO2 before and during a PLR and then before and after volume expansion in responders and non-responders are displayed in Table 2. During a PLR, the mean arterial pressure, central venous pressure, cardiac output, cardiac index, stroke volume, stroke volume index and PtcO2 increased significantly, while the heart rate and PtcCO2 decreased significantly in responders. After volume expansion, the mean arterial pressure, central venous pressure, cardiac output, cardiac index, stroke volume, stroke volume index and PtcO2 increased significantly, while the heart rate decreased significantly in responders. However, in non-responders, the mean arterial pressure and central venous pressure increased significantly during a PLR. The mean arterial pressure, central venous pressure, cardiac output, cardiac index, stroke volume and stroke volume index increased significantly after volume expansion. Typical recording of the transcutaneous partial pressure of oxygen before and during a PLR and then before and after volume expansion in responders and non-responders is shown in Fig. 1.
Table 2
Hemodynamic variable at different phases in responders and non-responders during the study (n = 34)
Hemodynamic variable
Category
Before PLR
During PLR
Before volume expansion
After volume expansion
Heart rate (mean ± SD, beats/min)
Responder
99 ± 25
95 ± 23a
98 ± 25
93 ± 23b
Non-responder
98 ± 24
100 ± 23
98 ± 24
97 ± 23
Mean arterial pressure (mean ± SD, mmHg)
Responder
66 ± 10
78 ± 8a
67 ± 10
77 ± 8b
Non-responder
83 ± 13c
87 ± 13a
83 ± 12c
85 ± 12b
Central venous pressure (mean ± SD, mmHg)
Responder
8 ± 4
11 ± 5a
9 ± 4
11 ± 5b
Non-responder
9 ± 4
11 ± 5a
9 ± 4
11 ± 4b
Cardiac output (mean ± SD, L/min)
Responder
5.5 ± 2.6
6.5 ± 2.9a
5.6 ± 2.5
6.5 ± 3.0b
Non-responder
6.0 ± 2.3
6.1 ± 2.4
5.8 ± 2.3
6.0 ± 2.4b
Cardiac index (mean ± SD, l/min m2)
Responder
3.4 ± 1.4
4.0 ± 1.5a
3.4 ± 1.3
4.0 ± 1.6b
Non-responder
3.4 ± 1.2
3.5 ± 1.2
3.3 ± 1.2
3.4 ± 1.3b
Stroke volume (mean ± SD, ml)
Responder
57.4 ± 22.7
69.5 ± 26.5a
58.7 ± 22.3
71.7 ± 27.1b
Non-responder
63.8 ± 27.6
64.4 ± 28.7
62.6 ± 27.6
65.3 ± 30.4b
Stroke volume index (mean ± SD, ml/m2)
Responder
35.7 ± 14.0
43.4 ± 16.8a
36.6 ± 13.9
44.8 ± 17.0b
Non-responder
36.4 ± 15.6
36.7 ± 16.1
35.8 ± 15.7
37.3 ± 17.3b
PtcO2 (mean ± SD, mmHg)
Responder
90 ± 37
101 ± 38a
92 ± 33
108 ± 39b
Non-responder
117 ± 37c
116 ± 35
118 ± 37
116 ± 38
PtcCO2 (mean ± SD, mmHg)
Responder
39 ± 7
39 ± 7a
39 ± 7
39 ± 7
Non-responder
42 ± 13
41 ± 13
41 ± 13
41 ± 12
Responders refered to patients in whom volume expansion increased stroke volume ≥10% after 250 ml of rapid saline infusion in 10 min (n = 14). The remaining patients were defined as non-responders (n = 20)
PLR, passive leg raising; PtcO2, transcutaneous partial pressure of oxygen; PtcCO2, transcutaneous partial pressure of carbon dioxide
a p < 0.05 versus before PLR; b p < 0.05 versus before volume expansion; c p < 0.05 versus responders
Compared with responders, the baseline mean arterial pressure and PtcO2 before PLR were significantly higher in non-responders, while the cardiac output and stroke volume had no significant difference from the start or during a PLR or volume expansion. Changes in the stroke volume induced either by PLR or volume expansion were significantly greater in responders than in non-responders (Fig. 2).

Relationship between PtcO2 and stroke volume induced by PLR and volume expansion

The correlation between the absolute values of PtcO2 and stroke volume was not significant when induced by PLR or volume expansion.
Although the correlation between the changes in PtcO2 and stroke volume induced by PLR was not significant, the correlation between the changes in PtcO2 and stroke volume induced by volume expansion was significant (r 2 = 0.24, p = 0.004).

Ability of the volume expansion and PLR-induced changes in PtcO2 to predict fluid responsiveness

A PLR-induced change in the stroke volume ≥10% predicted fluid responsiveness with a sensitivity of 100 [77–100] % and specificity of 95 [75–100] %. Volume expansion induced an increase in the PtcO2 of 14% predicted fluid responsiveness with a sensitivity of 93 [66–100] % and specificity of 75 [51–91] %. PLR-induced an increase in the PtcO2 of 13% predicted fluid responsiveness with a sensitivity of 93 [66–100] % and specificity of 75 [51–91] % (Additional file 1: Table S1; Fig. 3).

Discussion

In this prospective study, our data suggested that PtcO2 could be used as a noninvasive tool that tracked the changes in stroke volume by volume expansion, and the changes in PtcO2 induced by volume expansion and the PLR test helped predict fluid responsiveness in critically ill patients with circulatory failure.
The aim of fluid resuscitation is to increase cardiac output and tissue perfusion, and the latter might be more important. Therefore, differentiating patients with better perfusion responsiveness to fluids matters a lot. However, the classical fluid responsiveness predicted parameters could only differentiate patients with a higher cardiac output after resuscitation (the gold standard is defined as a change in the stroke volume ≥10% after 250 ml of rapid saline infusion in 10 min). It is unknown whether tissue perfusion is improved in this scenario.
PtcO2 is measured by transcutaneous oxygen electrode sensors and could detect tissue ischemia or inadequate perfusion. As a continuous noninvasive parameter, in stable patients, the PtcO2 is a very stable variable such that even small changes are easily detectable. It has been reported that 40 mmHg for the PtcO2 is a critical value of death in sepsis. Tremper [11] suggested that the PtcO2 is an early warning sign of cardiorespiratory impairment in various shock animal models. Moreover, the PtcO2 is found to correlate with cardiac output. With fluid resuscitation, the PtcO2 responded more quickly at first than the increase in cardiac output. In a total of 1073 data sets of 106 critically ill adult patients, Tremper [12] found that the PtcO2 value responded quickly to changes in the blood flow with an approximate 1-min response time. Therefore, PtcO2 might track the change in the stroke volume, and it could predict the fluid responsiveness. It will be more meaningful if the PtcO2 response could replace the gold standard after fluids.
However, sometimes, cardiac fluid responsiveness may not be associated with peripheral tissue perfusion. It is reported that in septic shock patients with previous hypertension, increasing the dose of norepinephrine brings in cardiac output and microvascular improvement, but the relationship between the changes of cardiac out and microvascular variables is not related [13]. Even with increased cardiac output, the PtcO2 might be low, suggesting low perfusion. In our study, two patients who had a PtcO2 less than 40 mmHg at baseline with a relatively normal or high cardiac output did not survive.
More attention is needed when peripheral tissue perfusion is not linked to cardiac output. For example, microcirculation is responsible for regulating tissue perfusion to meet oxygen requirements. In patients with microcirculatory dysfunction, even cardiac output increased, tissue perfusion might not be changed. It is reported [14] that in delayed resuscitation situations, even fluid resuscitation enhancing cardiac output, microcirculation and tissue perfusion are not improved. Additionally, tissue oxygenation depends on adequate arterial oxygenation and total blood flow, diffusion of oxygen across capillaries and the distribution of microcirculatory flow. The capacity of tissue to take up and utilize oxygen is important as well. In shock, the PtcO2 might be inhibited by increased oxygen consumption of ischemic cells. Further increase in the cardiac output or oxygen no longer increases the PtcO2; the oxygen consumption depends on the supply, suggesting that as oxygen consumption increases, tissue hypoxia and hypoperfusion occur. Yu [7] reports that the PtcO2 is not changed with a higher FiO2 in shock, which is associated with mortality. Meanwhile, the local blood flow is always defined by local metabolic demands but not global blood flow. Therefore, even cardiac output increases, the PtcO2 response might not significant.
Multiple studies have demonstrated that only 40–50% of patients respond to a fluid challenge [15]. In our study, approximately 41% of patients responded to fluids, which explains why a fluid responsiveness prediction is needed before volume expansion. Moreover, simpler methods and noninvasive parameters should be used to predict fluid responsiveness.
The gold standard for assessing fluid responsiveness is defined as a change in the cardiac output or stroke volume ≥10–15% after a rapid 250 ml volume infusion [16]. However, as a simple, safe and reversible method that could promote venous blood move from the legs and splanchnic compartment to the thorax, the PLR is now used to accurately predict fluid responsiveness in most conditions [1719]. Therefore, we focused on PLR-induced changes in parameters. In our study, the change in the stroke volume induced either by the PLR or volume expansion was significantly greater in responders than in non-responders. A PLR-induced increase in the stroke volume of 10% predicted fluid responsiveness with a good sensitivity and specificity. Volume expansion and PLR-induced change of PtcO2 almost had the same ability to predict fluid responsiveness. However, the correlation between the changes in PtcO2 and stroke volume induced by PLR was not significant. The PLR could not generate a sustained increase in the stroke volume [20] or PtcO2 might be the reason for this observation.

Limitations

There are important limitations to this study. Firstly, we evaluated the stroke volume by using the NICOM system, a noninvasive bioreactance stroke volume monitoring technology [21, 22], that is not the gold standard for measuring stroke volume. However, NICOM has similar monitoring capabilities as bolus thermodilution [23, 24]. Secondly, only thirty-four patients were included in the study, and larger, higher powered trials are needed to verify the results.

Conclusions

In this prospective study, our data suggested that the PtcO2 could track the changes in stroke volume, also, the changes in the PtcO2 induced by volume expansion and PLR test reliably predicted fluid responsiveness in critically ill patients. However, larger trials are needed to verify the results.

Authors’ contributions

JYX participated in the design of the study, carried out the interpretation of data, participated in drafting, editing and submitting the manuscript. XP participated in the design of study and the entire experiment. CP participated in the design of study and the entire experiment. SXC assisted with data collection and statistical analysis. XWZ participated in data acquisition and analysis. MX participated in drafting and editing the manuscript. YY contributed to the design and coordination of the study. HBQ was responsible for conception and design, and revising the manuscript for important intellectual content. All authors read and approved the final manuscript.

Acknowledgements

Not applicable.

Competing interests

The authors declare that they have no competing interests.

Availability of data and materials

All data generated or analyzed during this study are included in this published article.
Consent to publish was obtained from the patients.
The study protocol was approved by the Ethics Committee of Zhongda Hospital, School of Medicine, Southeast University, and informed consent was given by each patient or their next of kin.

Funding

This work is partially supported by grants from the National Natural Science Foundations of China (81501705), grants from the Scientific Research Foundation of Graduate School of Southeast University (YBPY1604).

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
Literatur
1.
Zurück zum Zitat Eskesen TG, Wetterslev M, Perner A. Systematic review including re-analyses of 1148 individual data sets of central venous pressure as a predictor of fluid responsiveness. Intensive Care Med. 2016;42(3):324–32.CrossRefPubMed Eskesen TG, Wetterslev M, Perner A. Systematic review including re-analyses of 1148 individual data sets of central venous pressure as a predictor of fluid responsiveness. Intensive Care Med. 2016;42(3):324–32.CrossRefPubMed
2.
Zurück zum Zitat Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul JL. Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med. 2006;34(5):1402–7.CrossRefPubMed Monnet X, Rienzo M, Osman D, Anguel N, Richard C, Pinsky MR, Teboul JL. Passive leg raising predicts fluid responsiveness in the critically ill. Crit Care Med. 2006;34(5):1402–7.CrossRefPubMed
3.
Zurück zum Zitat Monnet X, Marik P, Teboul JL. Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis. Intensive Care Med. 2016;42(12):1935–47.CrossRefPubMed Monnet X, Marik P, Teboul JL. Passive leg raising for predicting fluid responsiveness: a systematic review and meta-analysis. Intensive Care Med. 2016;42(12):1935–47.CrossRefPubMed
5.
Zurück zum Zitat Monnet X, Bataille A, Magalhaes E, Barrois J, Le Corre M, Gosset C, Guerin L, Richard C, Teboul JL. End-tidal carbon dioxide is better than arterial pressure for predicting volume responsiveness by the passive leg raising test. Intensive Care Med. 2013;39(1):93–100.CrossRefPubMed Monnet X, Bataille A, Magalhaes E, Barrois J, Le Corre M, Gosset C, Guerin L, Richard C, Teboul JL. End-tidal carbon dioxide is better than arterial pressure for predicting volume responsiveness by the passive leg raising test. Intensive Care Med. 2013;39(1):93–100.CrossRefPubMed
6.
Zurück zum Zitat Tatevossian RG, Wo CC, Velmahos GC, Demetriades D, Shoemaker WC. Transcutaneous oxygen and CO2 as early warning of tissue hypoxia and hemodynamic shock in critically ill emergency patients. Crit Care Med. 2000;28(7):2248–53.CrossRefPubMed Tatevossian RG, Wo CC, Velmahos GC, Demetriades D, Shoemaker WC. Transcutaneous oxygen and CO2 as early warning of tissue hypoxia and hemodynamic shock in critically ill emergency patients. Crit Care Med. 2000;28(7):2248–53.CrossRefPubMed
7.
Zurück zum Zitat Yu M, Morita SY, Daniel SR, Chapital A, Waxman K, Severino R. Transcutaneous pressure of oxygen: a noninvasive and early detector of peripheral shock and outcome. Shock. 2006;26(5):450–6.CrossRefPubMed Yu M, Morita SY, Daniel SR, Chapital A, Waxman K, Severino R. Transcutaneous pressure of oxygen: a noninvasive and early detector of peripheral shock and outcome. Shock. 2006;26(5):450–6.CrossRefPubMed
8.
Zurück zum Zitat Sair M, Etherington PJ, Peter WC, Evans TW. Tissue oxygenation and perfusion in patients with systemic sepsis. Crit Care Med. 2001;29(7):1343–9.CrossRefPubMed Sair M, Etherington PJ, Peter WC, Evans TW. Tissue oxygenation and perfusion in patients with systemic sepsis. Crit Care Med. 2001;29(7):1343–9.CrossRefPubMed
9.
Zurück zum Zitat Chapital AD, Yu M, Ho HC, Wang J, Koss W, Takanishi DM Jr. Using transcutaneous oxygen pressure measurements as selection criteria for activated protein C use. J Trauma. 2008;65(1):30–3.CrossRefPubMed Chapital AD, Yu M, Ho HC, Wang J, Koss W, Takanishi DM Jr. Using transcutaneous oxygen pressure measurements as selection criteria for activated protein C use. J Trauma. 2008;65(1):30–3.CrossRefPubMed
10.
Zurück zum Zitat Cecconi M, Hofer C, Teboul JL, Pettila V, Wilkman E, Molnar Z, Della Rocca G, Aldecoa C, Artigas A, Jog S, Sander M, Spies C, Lefrant JY, De Backer D. Fluid challenges in intensive care: the FENICE study: a global inception cohort study. Intensive Care Med. 2015;41(9):1529–37.CrossRefPubMedPubMedCentral Cecconi M, Hofer C, Teboul JL, Pettila V, Wilkman E, Molnar Z, Della Rocca G, Aldecoa C, Artigas A, Jog S, Sander M, Spies C, Lefrant JY, De Backer D. Fluid challenges in intensive care: the FENICE study: a global inception cohort study. Intensive Care Med. 2015;41(9):1529–37.CrossRefPubMedPubMedCentral
11.
Zurück zum Zitat Tremper KK, Waxman K, Shoemaker WC. Effects of hypoxia and shock on transcutaneous PO2 values in dogs. Crit Care Med. 1979;7(12):526–31.CrossRefPubMed Tremper KK, Waxman K, Shoemaker WC. Effects of hypoxia and shock on transcutaneous PO2 values in dogs. Crit Care Med. 1979;7(12):526–31.CrossRefPubMed
12.
Zurück zum Zitat Tremper KK, Shoemaker WC. Transcutaneous oxygen monitoring of critically ill adults, with and without low flow shock. Crit Care Med. 1981;9(10):706–9.CrossRefPubMed Tremper KK, Shoemaker WC. Transcutaneous oxygen monitoring of critically ill adults, with and without low flow shock. Crit Care Med. 1981;9(10):706–9.CrossRefPubMed
13.
Zurück zum Zitat Xu JY, Ma SQ, Pan C, He HL, Cai SX, Hu SL, Liu AR, Liu L, Huang YZ, Guo FM, Yang Y, Qiu HB. A high mean arterial pressure target is associated with improved microcirculation in septic shock patients with previous hypertension: a prospective open label study. Crit Care. 2015;19:130.CrossRefPubMedPubMedCentral Xu JY, Ma SQ, Pan C, He HL, Cai SX, Hu SL, Liu AR, Liu L, Huang YZ, Guo FM, Yang Y, Qiu HB. A high mean arterial pressure target is associated with improved microcirculation in septic shock patients with previous hypertension: a prospective open label study. Crit Care. 2015;19:130.CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Ospina-Tascon G, Neves AP, Occhipinti G, Donadello K, Büchele G, Simion D, Chierego ML, Silva TO, Fonseca A, Vincent JL, De Backer D. Effects of fluids on microvascular perfusion in patients with severe sepsis. Intensive Care Med. 2010;36(6):949–55.CrossRefPubMed Ospina-Tascon G, Neves AP, Occhipinti G, Donadello K, Büchele G, Simion D, Chierego ML, Silva TO, Fonseca A, Vincent JL, De Backer D. Effects of fluids on microvascular perfusion in patients with severe sepsis. Intensive Care Med. 2010;36(6):949–55.CrossRefPubMed
16.
Zurück zum Zitat Gupta K, Sondergaard S, Parkin G, Leaning M, Aneman A. Applying mean systemic filling pressure to assess the response to fluid boluses in cardiac post-surgical patients. Intensive Care Med. 2015;41(2):265–72.CrossRefPubMed Gupta K, Sondergaard S, Parkin G, Leaning M, Aneman A. Applying mean systemic filling pressure to assess the response to fluid boluses in cardiac post-surgical patients. Intensive Care Med. 2015;41(2):265–72.CrossRefPubMed
17.
Zurück zum Zitat Préau S, Saulnier F, Dewavrin F, Durocher A, Chagnon JL. Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis. Crit Care Med. 2010;38(3):819–25.CrossRefPubMed Préau S, Saulnier F, Dewavrin F, Durocher A, Chagnon JL. Passive leg raising is predictive of fluid responsiveness in spontaneously breathing patients with severe sepsis or acute pancreatitis. Crit Care Med. 2010;38(3):819–25.CrossRefPubMed
18.
Zurück zum Zitat Boulain T, Achard JM, Teboul JL, Richard C, Perrotin D, Ginies G. Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients. Chest. 2002;121(4):1245–52.CrossRefPubMed Boulain T, Achard JM, Teboul JL, Richard C, Perrotin D, Ginies G. Changes in BP induced by passive leg raising predict response to fluid loading in critically ill patients. Chest. 2002;121(4):1245–52.CrossRefPubMed
19.
Zurück zum Zitat Cavallaro F, Sandroni C, Marano C, La Torre G, Mannocci A, De Waure C, Bello G, Maviglia R, Antonelli M. Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med. 2010;36(9):1475–83.CrossRefPubMed Cavallaro F, Sandroni C, Marano C, La Torre G, Mannocci A, De Waure C, Bello G, Maviglia R, Antonelli M. Diagnostic accuracy of passive leg raising for prediction of fluid responsiveness in adults: systematic review and meta-analysis of clinical studies. Intensive Care Med. 2010;36(9):1475–83.CrossRefPubMed
20.
Zurück zum Zitat Gaffney FA, Bastian BC, Thal ER, Atkins JM, Blomqvist CG. Passive leg raising does not produce a significant or sustained autotransfusion effect. J Trauma. 1982;22(3):190–3.CrossRefPubMed Gaffney FA, Bastian BC, Thal ER, Atkins JM, Blomqvist CG. Passive leg raising does not produce a significant or sustained autotransfusion effect. J Trauma. 1982;22(3):190–3.CrossRefPubMed
21.
Zurück zum Zitat Shoemaker WC, Belzberg H, Wo CC, Milzman DP, Pasquale MD, Baga L, Fuss MA, Fulda GJ, Yarbrough K, Van DeWater JP, Ferraro PJ, Thangathurai D, Roffey P, Velmahos G, Murray JA, Asensio JA, ElTawil K, Dougherty WR, Sullivan MJ, Patil RS, Adibi J, James CB, Demetriades D. Multicenter study of noninvasive monitoring systems as alternatives to invasive monitoring of acutely ill emergency patients. Chest. 1998;114(6):1643–52.CrossRefPubMed Shoemaker WC, Belzberg H, Wo CC, Milzman DP, Pasquale MD, Baga L, Fuss MA, Fulda GJ, Yarbrough K, Van DeWater JP, Ferraro PJ, Thangathurai D, Roffey P, Velmahos G, Murray JA, Asensio JA, ElTawil K, Dougherty WR, Sullivan MJ, Patil RS, Adibi J, James CB, Demetriades D. Multicenter study of noninvasive monitoring systems as alternatives to invasive monitoring of acutely ill emergency patients. Chest. 1998;114(6):1643–52.CrossRefPubMed
22.
Zurück zum Zitat Benomar B, Ouattara A, Estagnasie P, Brusset A, Squara P. Fluid responsiveness predicted by noninvasive bioreactance-based passive leg raise test. Intensive Care Med. 2010;36(11):1875–81.CrossRefPubMed Benomar B, Ouattara A, Estagnasie P, Brusset A, Squara P. Fluid responsiveness predicted by noninvasive bioreactance-based passive leg raise test. Intensive Care Med. 2010;36(11):1875–81.CrossRefPubMed
23.
Zurück zum Zitat Marque S, Cariou A, Chiche JD, Squara P. Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring. Crit Care. 2009;13(3):R73.CrossRefPubMedPubMedCentral Marque S, Cariou A, Chiche JD, Squara P. Comparison between Flotrac-Vigileo and Bioreactance, a totally noninvasive method for cardiac output monitoring. Crit Care. 2009;13(3):R73.CrossRefPubMedPubMedCentral
24.
Zurück zum Zitat Squara P, Rotcajg D, Denjean D, Estagnasie P, Brusset A. Comparison of monitoring performance of Bioreactance vs. pulse contour during lung recruitment maneuvers. Crit Care. 2009;13(4):R125.CrossRefPubMedPubMedCentral Squara P, Rotcajg D, Denjean D, Estagnasie P, Brusset A. Comparison of monitoring performance of Bioreactance vs. pulse contour during lung recruitment maneuvers. Crit Care. 2009;13(4):R125.CrossRefPubMedPubMedCentral
Metadaten
Titel
Fluid responsiveness predicted by transcutaneous partial pressure of oxygen in patients with circulatory failure: a prospective study
verfasst von
Jingyuan Xu
Xiao Peng
Chun Pan
Shixia Cai
Xiwen Zhang
Ming Xue
Yi Yang
Haibo Qiu
Publikationsdatum
01.12.2017