Internal jugular vein variability predicts fluid responsiveness in cardiac surgical patients with mechanical ventilation

verfasst von: Guo-guang Ma, Guang-wei Hao, Xiao-mei Yang, Du-ming Zhu, Lan Liu, Hua Liu, Guo-wei Tu, Zhe Luo

Erschienen in: Annals of Intensive Care | Ausgabe 1/2018

Abstract

Background

To evaluate the efficacy of using internal jugular vein variability (IJVV) as an index of fluid responsiveness in mechanically ventilated patients after cardiac surgery.

Methods

Seventy patients were assessed after cardiac surgery. Hemodynamic data coupled with ultrasound evaluation of IJVV and inferior vena cava variability (IVCV) were collected and calculated at baseline, after a passive leg raising (PLR) test and after a 500-ml fluid challenge. Patients were divided into volume responders (increase in stroke volume ≥ 15%) and non-responders (increase in stroke volume < 15%). We compared the differences in measured variables between responders and non-responders and tested the ability of the indices to predict fluid responsiveness.

Results

Thirty-five (50%) patients were fluid responders. Responders presented higher IJVV, IVCV and stroke volume variation (SVV) compared with non-responders at baseline (P < 0.05). The relationship between IJVV and SVV was moderately correlated (r = 0.51, P < 0.01). The areas under the receiver operating characteristic (ROC) curves for predicting fluid responsiveness were 0.88 (CI 0.78–0.94) for IJVV compared with 0.83 (CI 0.72–0.91), 0.97 (CI 0.89–0.99), 0.91 (CI 0.82–0.97) for IVCV, SVV, and the increase in stroke volume in response to a PLR test, respectively.

Conclusions

Ultrasound-derived IJVV is an accurate, easily acquired noninvasive parameter of fluid responsiveness in mechanically ventilated postoperative cardiac surgery patients, with a performance similar to that of IVCV.
Hinweise

Electronic supplementary material

The online version of this article (https://​doi.​org/​10.​1186/​s13613-017-0347-5) contains supplementary material, which is available to authorized users.
Guo-guang Ma and Guang-wei Hao have contributed equally to this work
Abkürzungen
HR
Heart rate
MAP
Mean arterial pressure
CVP
Central venous pressure
SV
Stroke volume
SVV
Stroke volume variation
IJV
Internal jugular venous
IJVV
Internal jugular venous variability
IVC
Inferior vena cava
IVCV
Inferior vena cava variability
PLR
Passive leg raising
PLR-ΔSV
The increase in stroke volume in response to a passive leg raising test
CSICU
Cardiac surgery intensive care unit
PEEP
Positive end-expiratory pressure
PBW
Predicted body weight
IPPV
Intermittent positive pressure ventilation
LVEF
Left ventricular ejection fraction
ROC
Receiver operating characteristic

Background

Fluid management is one of the most important treatments for stabilizing hemodynamics in patients after cardiac surgery. Hypovolemia may lead to inadequate organ perfusion, whereas fluid overload may lead to postoperative complications such as congestive heart failure or pulmonary edema [13]. In addition, patients who underwent cardiac surgery have a certain degree of myocardial stunning [4], and hence, caution should be taken regarding fluid management in patients with a limited cardiac reserve.
It is imperative to predict the patient’s fluid responsiveness before volume expansion [5]. Several parameters have been introduced in clinical practice to predict fluid responsiveness and to guide therapy [2]. Based on the influence of cycling intra-thoracic pressure on arterial pulse pressure or stroke volume, dynamic indicators such as arterial pulse pressure variation (PPV) or stroke volume variation (SVV) have been widely used as reliable predictors of fluid responsiveness [68]. However, these dynamic parameters have several limitations and can only be used under strict conditions.
Recently, noninvasive and point-of-care ultrasound seems to meet the criteria of an ideal bedside tool for fluid status assessment. Several studies have confirmed that respiratory variations of the superior and inferior vena cava diameters (collapsibility index [CI] and distensibility index [DI]) accurately reflect volume responsiveness in mechanically ventilated patients [9, 10]. Unfortunately, measurements of the inferior vena cava (IVC) and superior vena cava (SVC) may fail to predict fluid responsiveness following cardiac surgery due to methodological problems such as poor subcostal caval image quality caused by mediastinal air, surgical drains, dressings, abdominal distension or morbid obesity [1113]; a more accurate measurement would require transoesophageal echocardiography (TEE). It is well known that pressure and volume changes within the intra-thoracic systemic venous compartment can transmit to the extrathoracic veins, for example, the intra-abdominal IVC or extrathoracic internal jugular vein (IJV) [1416]. The IJV is, technically, much more easily accessible for sonographic visualization than the IVC, and measurement of the IJV does not require TEE. Internal jugular vein variability (IJVV) has been studied in several studies [1719], but its reliability has not been well confirmed in patients after cardiac surgery. The aim of this study was to evaluate the reliability of IJVV, as visualized by ultrasound, to predict fluid responsiveness in mechanically ventilated patients after cardiac surgery.

Methods

This study was approved by the Ethical Committee of Zhongshan Hospital affiliated to Fudan University (No. B2016077), and informed consent was obtained from all study participants. This trial has been registered at clinicaltrials.gov as NCT02852889.

Patient selection

Patients who underwent cardiac surgery between August and December 2016 in the Cardiac Surgery Intensive Care Unit (CSICU) of the Zhongshan Hospital of Fudan University were screened for inclusion by research personnel. All patients routinely underwent a TEE during the operation and a postoperative (after admission to ICU and prior to study enrollment) comprehensive transthoracic echocardiography (TTE). The TEE was used to monitor the hemodynamics and confirm the postoperative effect of surgery. TTE was used to identify different causes of hypotension in postoperative period such as obstructive shock, hypovolemia and reduced ventricular systolic function. The patients were included when they presented with circulatory instability and required a rapid fluid challenge based on the clinical judgment of the attending physician. The physician’s decision was principally based on the presence of clinical signs of acute circulatory failure (low blood pressure or urine output, tachycardia, or mottling) and/or clinical signs of organ hypoperfusion (renal dysfunction or hyperlactatemia). The exclusion criteria included age < 18 years; evidence of cardiac arrhythmia (e.g., atrial fibrillation); evidence of jugular vein thrombosis; bilaterally inserted venous catheters (jugular or subclavian vein); echocardiographic examination that showed the existence of severe tricuspid or mitral regurgitation or right heart dysfunction (right ventricular fractional area change < 40% examined by TEE; tricuspid annular plane systolic excursion < 16 mm examined by TTE); a history of radiotherapy or surgery of the neck region or back (making it impossible to put the patient in a supine position with the head elevated to 30°); a contraindication to the passive leg raising (PLR) test; and the inability to obtain interpretable ultrasound images due to a difficult acoustic window.
All enrolled patients were sedated via propofol and morphine infusion, and with absence of inspiratory efforts according to the ventilator waveform and monitoring parameters. No muscular blocking agents were used in this study. All patients were ventilated in the intermittent positive pressure ventilation (IPPV) mode in the supine position with the head elevated to 30°. The ventilatory parameters were adjusted to the following criteria: tidal volume (Vt): 8 ml/kg predicted body weight (PBW), Pplat < 30 cmH2O, positive end-expiratory pressure (PEEP): 5 cmH2O, respiratory rate: 12–16 breaths per minute, PaCO2 ≤ 45 mmHg and oxygen saturation (SaO2) > 96%. The following baseline data were recorded for each patient: age (years), weight (kg), height (cm), diagnosis, type of cardiac surgery, acute physiology and chronic health evaluation (APACHE) II score, European system for cardiac operative risk evaluation (EuroSCORE), vasoactive drug infusion rates and preoperative echocardiographic parameters [left ventricular ejection fraction (LVEF), presence of left ventricular hypertrophy, right ventricular end-diastolic diameter, and tricuspid regurgitation grade].

Measurements

We analyzed a series of measured hemodynamic variables from an indwelling radial arterial catheter and central venous catheter in each patient. These data included heart rate (HR) (beats/minute), mean arterial pressure (MAP) (mmHg), central venous pressure (CVP) (mmHg), stroke volume (SV) (ml), PLR-induced increase in stroke volume (PLR-ΔSV) (ml), and stroke volume variation (SVV) using the FloTrac/Vigileo (Edwards Lifesciences, Irvine, CA, USA) continuous hemodynamic monitoring system. The pressure transducers were consistently adjusted to the level of the patient’s right atrium.
Intensivists with a certification of ultrasound evaluation performed all of the ultrasound examinations. An associate critical care professor supervised the entire course of examinations. The intensivists performing the ultrasound examinations were blinded to the hemodynamic data. (These were collected by another investigator.) Sonographic measurements of the IJV and IVC diameters were taken using a Philips CX50 ultrasound device (Philips Healthcare, Hamburg, Germany) equipped with a linear transducer (L12-3 Broadband Linear Array Transducer) and a transthoracic phased array transducer (S5-1 Phased Array Transducer), respectively.
Patients admitted at the ICU after cardiac surgery had a conventional right IJV catheter. To avoid any risk of infection at the puncture site, sonographic measurements were taken on the left IJV. The IJV was visualized by placing the ultrasound transducer perpendicular to the skin in the transverse plane on the patient’s neck at the level of the cricoid cartilage in order to avoid interference from the probe-to-vein angle. The vein was identified by compression as well as by color Doppler imaging. To avoid any influence of external compression on the IJV diameter during the examination, sufficient ultrasound gel was used to prevent direct skin contact with the transducer [20], and thus, the least amount of pressure was applied (Fig. 1a).
An M-mode scan was recorded over a whole respiratory cycle (Fig. 1b, c), and then, the image was frozen. The maximum antero-posterior diameter of the IJV was measured at the end of inspiration [diamax (cm)], and the minimum diameter was measured at the end of expiration [diamin (cm)]. The IJV variability (IJVV) was calculated using the formula: IJVV (%) = (diamax − diamin)/[(diamax + diamin)/2] × 100. Using similar methods, the IVC was visualized longitudinally in the subxyphoid long-axis view, and its M-mode cursor was used to measure the IVC variability (IVCV) approximately 3 cm from the right atrium.

Study design

Ultrasound examinations and the collection of hemodynamic data were performed at baseline (T0, in a supine position with the head elevated to 30° for baseline measurements), 1 min after a PLR test (T1, the bed was automatically moved to a position with the head elevated to 0° and the legs up to 45°) and after a 500-mL Gelofusine challenge (T2, the bed was returned to the initial position, and fluid was infused over 30 min). PLR was performed in order to compare the predictive value of different parameters in predicting fluid responsiveness. Vasoactive drug infusion rates and ventilation settings were kept constant during the study procedures. Patients were classified as “volume responders” if there was an increase in SV ≥ 15% after the fluid challenge, and the remaining patients were classified as “volume non-responders” [21, 22].

Statistical analysis

The number of the enrolled patients was referred to similar studies evaluating the prediction ability of IJVV [1719]. All continuous variables except the doses of norepinephrine and dobutamine were normally distributed (Kolmogorov–Smirnov test). The results are expressed as the mean ± SD (standard deviation) or median (25–75% inter-quartile range, IQR) as appropriate. After checking the homogeneity of variance for each parameter, the difference between values was compared using the independent sample t test, and the comparisons of hemodynamic variables between the different study times were assessed using paired Student t tests. Comparisons between responders and non-responders were assessed using two-sample Student’s t tests. P values < 0.05 were considered statistically significant. Correlations were assessed by Pearson coefficient. Receiver operating characteristic (ROC) curves were constructed to establish the sensitivity and specificity of dynamic and static indicators in predicting fluid responsiveness. The areas under the ROC curves (AUCs) were compared using DeLong and colleagues’ test. The optimal cutoff of each variable was estimated by maximizing the Youden index. A difference between two AUCs was considered statistically significant, when the P value of DeLong and colleagues’ test was < 0.05. Statistical analyses were performed with the MedCalc 8.1.0.0 (Mariakerke, Belgium) and SPSS software (19.0).

Results

A total of seventy-five postoperative cardiac surgery patients were enrolled during a period of 5 months. Five patients were excluded because visualization of the IVC via ultrasound was technically difficult. Seventy patients (44 males and 26 females) were included in the final analysis. The reasons for hemodynamic instability were related to the hypovolemia (35 patients), cardiac dysfunction (27 patients) and vasoplegic shock (8 patients). The mean age of the patients was 61 ± 10 years, and the APACHE II scores were 9 ± 5. All patients were sedated and were in sinus rhythm. The patients’ mean LVEF (Simpson’s method) before surgery was 50%. Baseline patient characteristics and clinical data are shown in Table 1. Hemodynamic and ultrasound data in responders and non-responders at all study times [baseline (T0), during PLR (T1), and after fluid challenge (T2)] are reported in Table 2. Fluid challenge significantly increased SV by more than 15% in 35 (50%) patients (responders, from 39.87 ± 13.67 to 58.72 ± 22.16 ml, P < 0.05). The remaining 35 (50%) patients did not exhibit a significant change in SV (non-responders, from 49.86 ± 17.71 to 54.81 ± 16.53 ml). The results of PLR and fluid challenge in this study are shown in Additional file 1.
Table 1
Baseline characteristics of the patients (n = 70)
Characteristic
 
Age (years)
61 ± 10
Male sex, n (%)
44 (62.86)
Body mass index (kg/m2)
22 ± 3
Left ventricular ejection fraction (%)
50
Cardiac surgery category, n (%)
 Valve
37 (52.86)
 CABG
12 (17.14)
 CABG + valve
7 (10.00)
 Aortic surgery
9 (12.86)
 Others
5 (7.14)
Postoperative day, n (%)
d0
62 (88.57%)
 d1
8 (11.43%)
APACHE II scores
9 ± 5
EuroSCORE
4 ± 2
Tidal volume (mL)
520 ± 28
PEEP (cm H2O)
5
PaO2/FiO2 (mmHg)
123 ± 57
Lactate (mmol/L)
3.23 ± 3.39
Patients receiving norepinephrine, n (%)
45 (64.29)
Patients receiving dobutamine, n (%)
9 (12.86)
Dose of norepinephrine (μg kg−1 min−1)
0.24 (0.15–0.35)
Dose of dobutamine (μg kg−1 min−1)
0.33 (0.28–0.43)
Values are expressed as mean ± SD, median (25–75% inter-quartile range) or number and frequency in %
CABG coronary artery bypass grafting, APACHE II acute physiology and chronic health evaluation, EuroSCORE European system for cardiac operative risk evaluation, PEEP positive end-expiratory pressure, PaO 2 arterial partial pressure of oxygen, FiO 2 inspiratory fraction of oxygen
Table 2
Hemodynamic parameters measured in responders and non-responders
 
T0
T1
T2
HR (beats min−1)
 Responders
91 ± 20
89 ± 18
87 ± 14
 Non-responders
88 ± 17
88 ± 17
87 ± 16
SBP (mmHg)
 Responders
87 ± 19
95 ± 29
119 ± 26c
 Non-responders
111 ± 17a
116 ± 19a
112 ± 23
DBP (mmHg)
 Responders
46 ± 8
53 ± 7b
58 ± 8c
 Non-responders
55 ± 11a
58 ± 9a
54 ± 8a
MAP (mmHg)
 Responders
58 ± 10
67 ± 9b
73 ± 11c
 Non-responders
71 ± 10a
75 ± 10a
70 ± 9
CVP (mmHg)
 Responders
11 ± 4
11 ± 3
12 ± 3
 Non-responders
12 ± 4
14 ± 4a,b
13 ± 4
CO (L/min)
 Responders
3.60 ± 1.54
4.68 ± 1.79b
5.11 ± 2.15c
 Non-responders
4.17 ± 0.93
4.50 ± 1.17
4.69 ± 1.44
SV (ml)
 Responders
39.87 ± 13.67
52.99 ± 16.22b
58.72 ± 22.16c
 Non-responders
49.86 ± 17.71a
53.52 ± 18.14
54.81 ± 16.53
SVV (%)
 Responders
14.94 ± 1.85
10.34 ± 5.26b
8.71 ± 4.59c
 Non-responders
9.49 ± 2.67a
7.74 ± 4.83a
7.03 ± 2.67c
IJVV (%)
 Responders
23.04 ± 16.76
9.88 ± 13.76b
7.96 ± 8.72c
 Non-responders
9.90 ± 5.63a
6.38 ± 2.37b
5.73 ± 2.02c
IVCV (%)
 Responders
15.97 ± 4.08
8.98 ± 4.52b
8.08 ± 7.70c
 Non-responders
8.78 ± 5.42a
8.14 ± 4.94
6.41 ± 2.76c
Values are expressed as mean ± SD
HR heart rate, BP, SBP systolic blood pressure, DBP diastolic blood pressure, MAP mean arterial pressure, CVP central venous pressure, CO cardiac output, SV stroke volume, SVV stroke volume variation, IJVV internal jugular venous variability, IVCV inferior vena cava variability
T0 baseline, T1 after passive leg raising test, T2 after fluid expansion
aP < 0.05 non-responders versus responders
bP < 0.05 T1 versus T0
cP < 0.05 T2 versus T0
Basal HR was not different between the responders and non-responders either at T1 or T2 (T1 89 ± 18 vs. 88 ± 17 beats min−1, T2 87 ± 14 vs. 87 ± 16 beats min−1), although HR tended to decrease after the PLR test or fluid challenge in responders. Responders displayed an increase in SBP, DBP and MAP from T0 to T2 (87 ± 19 vs. 119 ± 26 mmHg, P < 0.05; 46 ± 8 vs. 58 ± 8 mmHg, P < 0.05; and 58 ± 10 vs. 73 ± 11 mmHg, P < 0.05, respectively), and the same changes are also observed from T0 to T1 in DBP and MAP but not in SBP. No significant change in arterial pressure or HR was observed in non-responders. Non-responders generally displayed a higher CVP than responders after PLR (T1 14 ± 4 vs. 11 ± 3 mmHg, P < 0.05, Table 2). Although CVP tended to increase after the PLR test or fluid challenge in non-responders, we found a significant increase in CVP only after PLR (12 ± 4 vs. 14 ± 4 mmHg, P < 0.05); a difference was not observed after volume expansion (12 ± 4 vs. 13 ± 4 mmHg). In responders, a significant change in CVP was not observed after the PLR test nor the fluid challenge (11 ± 4 vs. 11 ± 3 mmHg; 11 ± 4 vs. 12 ± 3 mmHg).
In volume responders, IJVV, IVCV and SVV were significantly higher compared with non-responders at baseline. All of these values significantly decreased after the PLR test or fluid administration in responders. However, we found that both responders and non-responders exhibited a significant reduction in IJVV from baseline to the PLR test time or post-volume expansion, and similar findings were also presented for IVCV after fluid challenge (Table 2). We determined that the relationship between IJVV and SVV was moderately correlated (Fig. 2a, r = 0.51, P < 0.01). IVCV and SVV were significantly correlated (Fig. 2b, r = 0.75, P < 0.01).
The AUCs established for SVV and PLR-ΔSV were comparable (0.97 vs. 0.91, P = 0.61). The AUC of SVV was significantly greater than that of IVCV (0.97 vs. 0.83, P < 0.01) and IJVV (0.97 vs. 0.88, P = 0.03) (Fig. 3a). The AUCs for static indicators (CVP, IVC diameter and IJV diameter) were significantly lower than that of dynamic indicators (Fig. 3b). An SVV value > 12% was able to identify volume responders with a sensitivity of 91.43%, a specificity of 94.29% and an AUC of 0.97 (CI 0.89–0.99). The PLR-ΔSV > 12.84% for the prediction of fluid responsiveness was associated with a sensitivity of 100%, a specificity of 82.86% and an AUC of 0.91 (CI 0.82–0.97). IJVV > 12.99% predicted fluid responsiveness with a sensitivity of 91.43%, a specificity of 82.86% and an AUC of 0.88 (CI 0.78–0.94). IVCV showed an AUC of 0.83 (CI 0.72–0.91) with a cutoff value of 13.39% (sensitivity 85.71% and specificity 85.71%) (Table 3). A significant difference between IJVV and IVCV was not observed (0.88 vs. 0.83, P = 0.43).
Table 3
Diagnostic ability of the different indices of fluid responsiveness
 
AUC (95% CI)
Optimal cutoff (%)
Sensitivity (%)
Specificity (%)
Youden index
Positive predictive value
Negative predictive value
Positive likelihood ratio
Negative likelihood ratio
Dynamic indicators
 SVV
0.97 (0.89–0.99)
12.00
91.43
94.29
0.86
0.94
0.92
16.00
0.09
 PLR-ΔSV
0.91 (0.82–0.97)
12.84
100.00
82.86
0.83
0.85
1.00
5.83
0.00
 IJVV
0.88 (0.78–0.94)
12.99
91.43
82.86
0.74
0.84
0.91
5.33
0.10
 IVCV
0.83 (0.72–0.91)
13.39
85.71
85.71
0.71
0.86
0.86
6.00
0.17
Static indicators
 CVP
0.70 (0.57–0.80)
11.00
60.00
77.14
0.37
0.72
0.66
2.63
0.52
 IVCmax
0.53 (0.40–0.65)
1.57
48.57
74.29
0.23
0.65
0.59
1.89
0.69
 IVCmin
0.58 (0.46–0.70)
1.40
54.29
74.29
0.29
0.68
0.62
2.11
0.62
 IJVmax
0.55 (0.43–0.67)
0.86
48.57
65.71
0.14
0.59
0.56
1.42
0.78
 IJVmin
0.55 (0.43–0.67)
0.64
51.43
80.00
0.31
0.72
0.62
2.57
0.61
AUC area under the receiver operating characteristic curve, CI confidence interval, SVV respiratory variation of stroke volume, PLR-∆SV the increase in stroke volume in response to a passive leg raising test, IJVV internal jugular venous variability, IVCV inferior vena cava variability, CVP central venous pressure, IVCmax the maximum inferior vena cava diameter, IVCmin the minimum inferior vena cava diameter, IJVmax the maximum internal jugular venous diameter, IJVmin the minimum internal jugular venous diameter
The intra-observer variability and inter-observer variability of IJVV measurement were further investigated in 30 patients. The results showed good concordance between estimation of IJVV by the two investigators, with a mean bias of − 0.01 and limits of agreement between − 0.1 and 0.08. The reliability of the measurements was also analyzed with intraclass correlation coefficients (ICCs) assessing intra-observer and inter-observer correlation (Additional file 2).

Discussion

The objective of this study was to evaluate whether ultrasound assessment of IJV respiratory diameter changes can serve as a simple indicator of fluid responsiveness in mechanically ventilated patients after cardiac surgery. Our data showed that IJVV was comparable to IVCV in predicting fluid responsiveness. There was a positive correlation between SVV and ventilator-induced IJVV. It was also found that the predictive value of PLR-ΔSV and SVV was superior to that of IVCV and IJVV.
Correcting hypovolemia is of paramount importance during the postoperative critical care of cardiac surgical patients. However, its correction should be carefully guided to avoid unnecessary volume expansion [23]. Therefore, many investigators have explored reliable techniques with the goal of predicting fluid responsiveness in critically ill patients. Static parameters, such as CVP, are poor predictors of fluid responsiveness as previously reported and as shown in our study [2325]. Based on the hemodynamic consequences of the heart–lung interactions, the use of dynamic indices of preload that result from respiratory variations is well-accepted bedside parameters of fluid responsiveness [7]. It was worth mentioning that tidal volume should be large enough to promote adequate preload variations. Fluid responsiveness cannot be reliably predicted if the tidal volume is < 8 ml/kg PBW [26]. Therefore, a Vt 8 mL/kg PBW was set in the present study. As higher PEEP may have adverse effects such as overinflation and hemodynamic deterioration, a PEEP of 5 cm H2O was set initially after cardiac surgery according to our routine practice.
Mechanical ventilation-induced cyclic variations in vena cava diameter have been shown to be accurate predictors of fluid responsiveness. In our study, we have shown that the IVCV was a good predictor of fluid responsiveness for mechanically ventilated patients following cardiac surgery. IVCV threshold values of 13.39% have been reported in the literature to be able to discriminate between responders and non-responders with a sensitivity of 85.71% and a specificity of 85.71%. Based on the associations of intra-thoracic venous pressure and volume with extrathoracic venous pressure, we hypothesized that fluid responsiveness may also be reflected by changes in IJV pressure as assessed by IJVV. Measuring IJV diameter change is easily achieved with ultrasound with minimal training, as this approach is frequently used for ultrasound-guided central vein catheterization. We demonstrated the reliability of IJVV with a value of 12.99% in detecting fluid responsiveness, having a sensitivity of 91.43% and a specificity of 82.86% in mechanically ventilated cardiac surgical patients.
Several studies have investigated the ability of respiratory variations in IJV diameter to evaluate hypovolemia or a hemodynamic response to a fluid challenge. Guarracino et al. have reported that IJV distensibility [(diamax − diamin)/diamin × 100] accurately predicts volume responsiveness in mechanically ventilated septic patients [19]. A cutoff value of 18% IJV distensibility resulted in 80% sensitivity and 85% specificity for predicting a fluid response, which was defined as an increase in cardiac index ≥ 15%. However, this study did not include patients with cardiac disease who have different hemodynamic characteristics. Moreover, the authors did not compare the predictive values of IVCV and IJVV. Thudium et al. showed that ultrasound evaluation of IJV extensibility can change in response to preload-altering orthostatic maneuvers and pulse pressure variation alterations [17]. However, this study was conducted at the cardiac surgery intensive care unit, and all of the patients were included after elective cardiac surgery; the reporters did not perform the standard fluid challenge, and the subgroup analysis showed that different surgery categories had different results. Broilo et al. verified the hypothesis that respiratory variations of the IVC and IJV were correlated [18]. These two indicators showed a significant agreement in evaluating fluid responsiveness. However, they did not identify changes in cardiac output following a fluid challenge, and they did not evaluate changes in the vein diameters before and after a fluid challenge. There were other studies demonstrating its utility, using measurements of the IJV to detect early hemorrhage in healthy volunteers that were donating blood [27, 28]. To our knowledge, this was the first study to evaluate the value of IJVV in predicting fluid responsiveness based on a standard fluid challenge in mechanically ventilated cardiac surgical patients.
Our study has several limitations. First, all subjects were on mechanical ventilation and absence of spontaneous breathing under sedation. Whether the conclusions can be extrapolated to patients with spontaneous breathing remains uncertain. Second, an uncalibrated system for hemodynamic monitoring was used in this study. Although the validation of FloTrac/vigileo system in measuring cardiac output has been assessed by numerous studies, the reliability of uncalibrated devices is still under debate [2931]. Compared with pulmonary artery catheter (PAC) or transpulmonary thermodilution devices, FloTrac/vigileo system can be directly connected to the arterial catheter and has the advantage of auto-calibration. It theoretically meets the needs for rapidly assessing hemodynamic changes. Moreover, the dynamic indicator of SVV that could continuously displayed by the FloTrac/Vigileo system has also been shown to be able to predict fluid responsiveness in cardiac surgical patients [3234]. Third, we did not enroll patients with right heart failure, as severe right heart failure or high CVP could influence IJV pressure and diameter and may decrease the relative variability even in the presence of preload responsiveness. Fourth, technical errors were possible, because even a slight pressure could have caused a great change in the cross-sectional image and diameter of the IJV during the acquisition of the measurements. We have made further efforts on the reproducibility and agreement of IJVV in 30 patients. The results showed good concordance between estimation of IJVV by the two investigators. Fifth, the initial semirecumbent position of the patient was 30° head of the bed (HOB) elevated instead of 45° (standard baseline position of PLR), because this was the recommended position for supine ventilated patient in the ICU. It was believed that this was more consistent with clinical scenario. Furthermore, taking sonographic measurements of the IVC diameters seems more easily in the position with HOB 30° than HOB 45°. The predict value of IJVV in other positions (such as the horizontal position) remains to be assessed.

Conclusions

Ultrasound evaluation of IJVV is a simple, easy and readily accessible bedside measurement that predicts volume responsiveness in mechanically ventilated cardiac surgical patients. The respiratory variations of the IJV and IVC showed comparable value in the prediction of fluid responsiveness.

Authors’ contributions

G-gM, G-wH, G-wT performed the literature search, extracted date and drafted the manuscript. X-mY, LL and HL reviewed studies for inclusion and extracted data. G-wT, D-mZ and ZL performed the analysis and helped draft the manuscript. G-wT and ZL conceived the idea, participated in manuscript writing and revision. All authors read and approved the final manuscript.

Acknowledgements

None.

Competing interests

The authors declare that they have no competing interests.

Availability of data and materials

All data are presented within the manuscript.
All patients signed informed consent and provided consent for publication.
This study was approved by the Ethical Committee of Zhongshan Hospital affiliated to Fudan University (No. B2016077), and informed consent was obtained from all study participants. This trial has been registered at clinicaltrials.gov as NCT02852889.

Funding

This article was supported by grants from the National Natural Science Foundation of China (81500067), Natural Science Foundation of Shanghai (16ZR1405600), Health and Family Planning Commission of Shanghai (20154Y011) and the research funds of Zhong Shan Hospital (2017ZSYXQN23 and 2016ZSQN23).

Publisher’s Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.
Literatur
1.
Zurück zum Zitat Lee J, de Louw E, Niemi M, Nelson R, Mark RG, Celi LA, et al. Association between fluid balance and survival in critically ill patients. J Intern Med. 2015;277:468–77.CrossRefPubMed Lee J, de Louw E, Niemi M, Nelson R, Mark RG, Celi LA, et al. Association between fluid balance and survival in critically ill patients. J Intern Med. 2015;277:468–77.CrossRefPubMed
2.
Zurück zum Zitat Carsetti A, Cecconi M, Rhodes A. Fluid bolus therapy: monitoring and predicting fluid responsiveness. Curr Opin Crit Care. 2015;21:388–94.CrossRefPubMed Carsetti A, Cecconi M, Rhodes A. Fluid bolus therapy: monitoring and predicting fluid responsiveness. Curr Opin Crit Care. 2015;21:388–94.CrossRefPubMed
3.
Zurück zum Zitat Kalus JS, Caron MF, White CM, Mather JF, Gallagher R, Boden WE, et al. Impact of fluid balance on incidence of atrial fibrillation after cardiothoracic surgery. Am J Cardiol. 2004;94:1423–5.CrossRefPubMed Kalus JS, Caron MF, White CM, Mather JF, Gallagher R, Boden WE, et al. Impact of fluid balance on incidence of atrial fibrillation after cardiothoracic surgery. Am J Cardiol. 2004;94:1423–5.CrossRefPubMed
4.
Zurück zum Zitat Mentzer RM Jr. Myocardial protection in heart surgery. J Cardiovasc Pharmacol Ther. 2011;16:290–7.CrossRefPubMed Mentzer RM Jr. Myocardial protection in heart surgery. J Cardiovasc Pharmacol Ther. 2011;16:290–7.CrossRefPubMed
5.
Zurück zum Zitat Donati A, Carsetti A, Damiani E, Adrario E, Romano R, Pelaia P. Fluid responsiveness in critically ill patients. Indian J Crit Care Med. 2015;19:375–6.CrossRefPubMedPubMedCentral Donati A, Carsetti A, Damiani E, Adrario E, Romano R, Pelaia P. Fluid responsiveness in critically ill patients. Indian J Crit Care Med. 2015;19:375–6.CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Suzuki S, Woinarski NC, Lipcsey M, Candal CL, Schneider AG, Glassford NJ, et al. Pulse pressure variation-guided fluid therapy after cardiac surgery: a pilot before-and-after trial. J Crit Care. 2014;29:992–6.CrossRefPubMed Suzuki S, Woinarski NC, Lipcsey M, Candal CL, Schneider AG, Glassford NJ, et al. Pulse pressure variation-guided fluid therapy after cardiac surgery: a pilot before-and-after trial. J Crit Care. 2014;29:992–6.CrossRefPubMed
7.
Zurück zum Zitat Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37:2642–7.CrossRefPubMed Marik PE, Cavallazzi R, Vasu T, Hirani A. Dynamic changes in arterial waveform derived variables and fluid responsiveness in mechanically ventilated patients: a systematic review of the literature. Crit Care Med. 2009;37:2642–7.CrossRefPubMed
8.
Zurück zum Zitat Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, et al. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med. 2000;162:134–8.CrossRefPubMed Michard F, Boussat S, Chemla D, Anguel N, Mercat A, Lecarpentier Y, et al. Relation between respiratory changes in arterial pulse pressure and fluid responsiveness in septic patients with acute circulatory failure. Am J Respir Crit Care Med. 2000;162:134–8.CrossRefPubMed
9.
Zurück zum Zitat Vieillard-Baron A, Chergui K, Rabiller A, Peyrouset O, Page B, Beauchet A, et al. Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients. Intensive Care Med. 2004;30:1734–9.CrossRefPubMed Vieillard-Baron A, Chergui K, Rabiller A, Peyrouset O, Page B, Beauchet A, et al. Superior vena caval collapsibility as a gauge of volume status in ventilated septic patients. Intensive Care Med. 2004;30:1734–9.CrossRefPubMed
10.
Zurück zum Zitat Barbier C, Loubieres Y, Schmit C, Hayon J, Ricome JL, Jardin F, et al. Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med. 2004;30:1740–6.PubMed Barbier C, Loubieres Y, Schmit C, Hayon J, Ricome JL, Jardin F, et al. Respiratory changes in inferior vena cava diameter are helpful in predicting fluid responsiveness in ventilated septic patients. Intensive Care Med. 2004;30:1740–6.PubMed
11.
Zurück zum Zitat Tavazzi G, Price S, Fletcher N. Bedside ultrasonographic measurement of the inferior vena cava. J Cardiothorac Vasc Anesth. 2015;29:e54–5.CrossRefPubMed Tavazzi G, Price S, Fletcher N. Bedside ultrasonographic measurement of the inferior vena cava. J Cardiothorac Vasc Anesth. 2015;29:e54–5.CrossRefPubMed
12.
Zurück zum Zitat Sobczyk D, Nycz K, Andruszkiewicz P. Bedside ultrasonographic measurement of the inferior vena cava fails to predict fluid responsiveness in the first 6 hours after cardiac surgery: a prospective case series observational study. J Cardiothorac Vasc Anesth. 2015;29:663–9.CrossRefPubMed Sobczyk D, Nycz K, Andruszkiewicz P. Bedside ultrasonographic measurement of the inferior vena cava fails to predict fluid responsiveness in the first 6 hours after cardiac surgery: a prospective case series observational study. J Cardiothorac Vasc Anesth. 2015;29:663–9.CrossRefPubMed
13.
Zurück zum Zitat Nagdev AD, Merchant RC, Tirado-Gonzalez A, Sisson CA, Murphy MC. Emergency department bedside ultrasonographic measurement of the caval index for noninvasive determination of low central venous pressure. Ann Emerg Med. 2010;55:290–5.CrossRefPubMed Nagdev AD, Merchant RC, Tirado-Gonzalez A, Sisson CA, Murphy MC. Emergency department bedside ultrasonographic measurement of the caval index for noninvasive determination of low central venous pressure. Ann Emerg Med. 2010;55:290–5.CrossRefPubMed
14.
Zurück zum Zitat Chua Chiaco JM, Parikh NI, Fergusson DJ. The jugular venous pressure revisited. Cleve Clin J Med. 2013;80:638–44.CrossRefPubMed Chua Chiaco JM, Parikh NI, Fergusson DJ. The jugular venous pressure revisited. Cleve Clin J Med. 2013;80:638–44.CrossRefPubMed
15.
Zurück zum Zitat Conn RD, O’Keefe JH. Simplified evaluation of the jugular venous pressure: significance of inspiratory collapse of jugular veins. Mo Med. 2012;109:150–2.PubMed Conn RD, O’Keefe JH. Simplified evaluation of the jugular venous pressure: significance of inspiratory collapse of jugular veins. Mo Med. 2012;109:150–2.PubMed
16.
Zurück zum Zitat Constant J. Using internal jugular pulsations as a manometer for right atrial pressure measurements. Cardiology. 2000;93:26–30.CrossRefPubMed Constant J. Using internal jugular pulsations as a manometer for right atrial pressure measurements. Cardiology. 2000;93:26–30.CrossRefPubMed
17.
Zurück zum Zitat Thudium M, Klaschik S, Ellerkmann RK, Putensen C, Hilbert T. Is internal jugular vein extensibility associated with indices of fluid responsiveness in ventilated patients? Acta Anaesthesiol Scand. 2016;60:723–33.CrossRefPubMed Thudium M, Klaschik S, Ellerkmann RK, Putensen C, Hilbert T. Is internal jugular vein extensibility associated with indices of fluid responsiveness in ventilated patients? Acta Anaesthesiol Scand. 2016;60:723–33.CrossRefPubMed
18.
Zurück zum Zitat Broilo F, Meregalli A, Friedman G. Right internal jugular vein distensibility appears to be a surrogate marker for inferior vena cava vein distensibility for evaluating fluid responsiveness. Rev Bras Ter Intensiva. 2015;27:205–11.CrossRefPubMedPubMedCentral Broilo F, Meregalli A, Friedman G. Right internal jugular vein distensibility appears to be a surrogate marker for inferior vena cava vein distensibility for evaluating fluid responsiveness. Rev Bras Ter Intensiva. 2015;27:205–11.CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat Guarracino F, Ferro B, Forfori F, Bertini P, Magliacano L, Pinsky MR. Jugular vein distensibility predicts fluid responsiveness in septic patients. Crit Care. 2014;18:647.CrossRefPubMedPubMedCentral Guarracino F, Ferro B, Forfori F, Bertini P, Magliacano L, Pinsky MR. Jugular vein distensibility predicts fluid responsiveness in septic patients. Crit Care. 2014;18:647.CrossRefPubMedPubMedCentral
20.
Zurück zum Zitat Prekker ME, Scott NL, Hart D, Sprenkle MD, Leatherman JW. Point-of-care ultrasound to estimate central venous pressure: a comparison of three techniques. Crit Care Med. 2013;41:833–41.CrossRefPubMed Prekker ME, Scott NL, Hart D, Sprenkle MD, Leatherman JW. Point-of-care ultrasound to estimate central venous pressure: a comparison of three techniques. Crit Care Med. 2013;41:833–41.CrossRefPubMed
21.
Zurück zum Zitat Cecconi M, Parsons AK, Rhodes A. What is a fluid challenge? Curr Opin Crit Care. 2011;17:290–5.CrossRefPubMed Cecconi M, Parsons AK, Rhodes A. What is a fluid challenge? Curr Opin Crit Care. 2011;17:290–5.CrossRefPubMed
23.
Zurück zum Zitat Preisman S, Kogan S, Berkenstadt H, Perel A. Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators. Br J Anaesth. 2005;95:746–55.CrossRefPubMed Preisman S, Kogan S, Berkenstadt H, Perel A. Predicting fluid responsiveness in patients undergoing cardiac surgery: functional haemodynamic parameters including the Respiratory Systolic Variation Test and static preload indicators. Br J Anaesth. 2005;95:746–55.CrossRefPubMed
24.
Zurück zum Zitat Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest. 2008;134:172–8.CrossRefPubMed Marik PE, Baram M, Vahid B. Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares. Chest. 2008;134:172–8.CrossRefPubMed
25.
Zurück zum Zitat Osman D, Ridel C, Ray P, Monnet X, Anguel N, Richard C, et al. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med. 2007;35:64–8.CrossRefPubMed Osman D, Ridel C, Ray P, Monnet X, Anguel N, Richard C, et al. Cardiac filling pressures are not appropriate to predict hemodynamic response to volume challenge. Crit Care Med. 2007;35:64–8.CrossRefPubMed
26.
Zurück zum Zitat De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL. Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med. 2005;31:517–23.CrossRefPubMed De Backer D, Heenen S, Piagnerelli M, Koch M, Vincent JL. Pulse pressure variations to predict fluid responsiveness: influence of tidal volume. Intensive Care Med. 2005;31:517–23.CrossRefPubMed
27.
Zurück zum Zitat Unluer EE, Kara PH. Ultrasonography of jugular vein as a marker of hypovolemia in healthy volunteers. Am J Emerg Med. 2013;31:173–7.CrossRefPubMed Unluer EE, Kara PH. Ultrasonography of jugular vein as a marker of hypovolemia in healthy volunteers. Am J Emerg Med. 2013;31:173–7.CrossRefPubMed
28.
Zurück zum Zitat Akilli NB, Cander B, Dundar ZD, Koylu R. A new parameter for the diagnosis of hemorrhagic shock: jugular index. J Crit Care. 2012;27(530):e13–8. Akilli NB, Cander B, Dundar ZD, Koylu R. A new parameter for the diagnosis of hemorrhagic shock: jugular index. J Crit Care. 2012;27(530):e13–8.
29.
Zurück zum Zitat Marque S, Gros A, Chimot L, Gacouin A, Lavoue S, Camus C, et al. Cardiac output monitoring in septic shock: evaluation of the third-generation Flotrac-Vigileo. J Clin Monit Comput. 2013;27:273–9.CrossRefPubMed Marque S, Gros A, Chimot L, Gacouin A, Lavoue S, Camus C, et al. Cardiac output monitoring in septic shock: evaluation of the third-generation Flotrac-Vigileo. J Clin Monit Comput. 2013;27:273–9.CrossRefPubMed
30.
Zurück zum Zitat Monnet X, Anguel N, Jozwiak M, Richard C, Teboul JL. Third-generation FloTrac/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients. Br J Anaesth. 2012;108:615–22.CrossRefPubMed Monnet X, Anguel N, Jozwiak M, Richard C, Teboul JL. Third-generation FloTrac/Vigileo does not reliably track changes in cardiac output induced by norepinephrine in critically ill patients. Br J Anaesth. 2012;108:615–22.CrossRefPubMed
31.
Zurück zum Zitat De Backer D, Marx G, Tan A, Junker C, Van Nuffelen M, Huter L, et al. Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients. Intensive Care Med. 2011;37:233–40.CrossRefPubMed De Backer D, Marx G, Tan A, Junker C, Van Nuffelen M, Huter L, et al. Arterial pressure-based cardiac output monitoring: a multicenter validation of the third-generation software in septic patients. Intensive Care Med. 2011;37:233–40.CrossRefPubMed
32.
Zurück zum Zitat Krige A, Bland M, Fanshawe T. Fluid responsiveness prediction using Vigileo FloTrac measured cardiac output changes during passive leg raise test. J Intensive Care. 2016;4:63.CrossRefPubMedPubMedCentral Krige A, Bland M, Fanshawe T. Fluid responsiveness prediction using Vigileo FloTrac measured cardiac output changes during passive leg raise test. J Intensive Care. 2016;4:63.CrossRefPubMedPubMedCentral
33.
Zurück zum Zitat Kim SY, Song Y, Shim JK, Kwak YL. Effect of pulse pressure on the predictability of stroke volume variation for fluid responsiveness in patients with coronary disease. J Crit Care. 2013;28(318):e1–7. Kim SY, Song Y, Shim JK, Kwak YL. Effect of pulse pressure on the predictability of stroke volume variation for fluid responsiveness in patients with coronary disease. J Crit Care. 2013;28(318):e1–7.
34.
Zurück zum Zitat Cannesson M, Musard H, Desebbe O, Boucau C, Simon R, Henaine R, et al. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg. 2009;108:513–7.CrossRefPubMed Cannesson M, Musard H, Desebbe O, Boucau C, Simon R, Henaine R, et al. The ability of stroke volume variations obtained with Vigileo/FloTrac system to monitor fluid responsiveness in mechanically ventilated patients. Anesth Analg. 2009;108:513–7.CrossRefPubMed
Metadaten
Titel
Internal jugular vein variability predicts fluid responsiveness in cardiac surgical patients with mechanical ventilation
verfasst von
Guo-guang Ma
Guang-wei Hao
Xiao-mei Yang
Du-ming Zhu
Lan Liu
Hua Liu
Guo-wei Tu
Zhe Luo
Publikationsdatum
01.12.2018
Verlag
Springer International Publishing
Erschienen in
Annals of Intensive Care / Ausgabe 1/2018
Elektronische ISSN: 2110-5820
DOI
https://doi.org/10.1186/s13613-017-0347-5

Weitere Artikel der Ausgabe 1/2018

Annals of Intensive Care 1/2018 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.