Circulation Journal
Online ISSN : 1347-4820
Print ISSN : 1346-9843
ISSN-L : 1346-9843
Cardiovascular Intervention
Vascular Response Occurring at 3 Months After Everolimus-Eluting Cobalt–Chromium Stent Implantation in Patients With ST-Segment Elevation Myocardial Infarction vs. Stable Coronary Artery Disease
Masaru IshidaDaisuke TerashitaTomonori ItohHiromasa OtakeYoshiro TsukiyamaTatsuo KikuchiTakatoshi HayashiTakahide SuzukiYoshiaki ItoTakashi MoritaKiyoshi HibiTakahiro SawadaTakayuki OkamuraJunya ShiteFumiaki TakahashiToshiro ShinkeYoshihiro Morino
Author information
JOURNAL OPEN ACCESS FULL-TEXT HTML
Supplementary material

2020 Volume 84 Issue 11 Pages 1941-1948

Details
Abstract

Background:Second-generation drug-eluting stents (DES) reduce the incidence of stent thrombosis, even in patients with ST-segment elevated myocardial infarction (STEMI). However, the early local vascular healing after DES implantation in STEMI lesions, which mainly concerns stent thrombosis, is still unclear.

Methods and Results:We attempted to determine early local vascular healing 3 months after cobalt–chromium everolimus-eluting stent (CoCr-EES) implantation in STEMI lesions relative to stable coronary artery disease (CAD) lesions. This prospective, multicenter study analyzed 96 total lesions (STEMI=49, stable CAD=51) by frequency domain-optical coherence tomography (FD-OCT) performed post-procedure and at the 3-month follow-up. Although CoCr-EES implanted in STEMI were almost entirely covered at 3 months, they had a relatively high incidence of uncovered struts compared with stable CAD (5.5% vs. 1.6%, P<0.001). Intrastent thrombus in the 2 groups was primarily resolved at the 3-month follow-up (STEMI: 91.7%→26.5%, stable CAD: 74.5%→11.8%). Regarding irregular protrusion, complete resolution was observed in stable CAD (21.6%→0%), while a few stents remained in STEMI (79.2%→8.2%). Although there were almost no changes for the serial change of average lumen area in STEMI, there were slight but significant decreases in stable CAD [STEMI 0.08 (−0.44, 0.55) mm2, stable CAD −0.35 (−0.55, 0.11) mm2; P=0.009].

Conclusions:Although strut coverage after CoCr-EES implantation for STEMI lesions was slightly delayed, the healing process appeared to be acceptable in both STEMI and stable CAD.

Content from these authors
© 2020 THE JAPANESE CIRCULATION SOCIETY

This article is licensed under a Creative Commons [Attribution-NonCommercial-NoDerivatives 4.0 International] license.
https://creativecommons.org/licenses/by-nc-nd/4.0/
Previous article Next article
feedback
Top