Aims

Minimally invasive transforaminal lumbar interbody fusion (MITLIF) has been well validated in overweight and obese patients who are consequently subject to a higher radiation exposure. This prospective multicentre study aimed to investigate the efficacy of a novel lumbar localisation system for MITLIF in overweight patients.

Patients and Methods

The initial study group consisted of 175 patients. After excluding 49 patients for various reasons, 126 patients were divided into two groups. Those in Group A were treated using the localisation system while those in Group B were treated by conventional means. The primary outcomes were the effective radiation dosage to the surgeon and the exposure time.

Results

There were 62 patients in Group A and 64 in Group B. The mean effective dosage was 0.0217 mSv (standard deviation (sd) 0.0079) in Group A and 0.0383 mSv (sd 0.0104) in Group B (p <  0.001). The mean fluoroscopy exposure time was 26.42 seconds (sd 5.91) in Group A and 40.67 seconds (sd 8.18) in Group B (p < 0.001). The operating time was 175.56 minutes (sd 32.23) and 206.08 minutes (sd 30.15) (p < 0.001), respectively. The mean pre-operative localisation time was 4.73 minutes (sd 0.84) in Group A and 7.03 minutes (sd 1.51) in Group B (p < 0.001). The mean screw placement time was 47.37 minutes (sd 10.43) in Group A and 67.86 minutes (sd 14.15) in Group B (p < 0.001). The pedicle screw violation rate was 0.35% (one out of 283) in Group A and 2.79% (eight out of 287) in Group B (p = 0.020).

Conclusion

The study shows that the localisation system can effectively reduce radiation exposure, exposure time, operating time, pre-operative localisation time, and screw placement time in overweight patients undergoing MITLIF.

Cite this article: Bone Joint J 2017;99-B:944–50.