Figures
Abstract
Several recent studies demonstrated that lung ultrasound could achieve desired diagnostic accuracy for transient tachypnea of the neonate (TTN). However, the diagnostic performance of lung ultrasound for TTN has not been systematically studied to date. This meta-analysis aimed to investigate the performance of lung ultrasound in diagnosing TTN. The relevant literature was searched in PubMed, Medline, the Cochrane Library, and Embase databases without any restriction in terms of language and time until January 31, 2021. Studies that assessed the diagnostic performance of lung ultrasound for TTN were included. Seven studies with 1514 participants were summarized. The lung ultrasound provided more accurate performance for diagnosing TTN with pooled sensitivity and specificity of 0.67 [95% confidence interval (CI) = 0.63–0.71] and 0.97 (95% CI = 0.95–0.98), respectively. A higher summarized area under the summary receiver operating characteristic curve was observed as 0.9906. Lower sensitivity and area under the curve (AUC) of B-lines for TTN were observed as 0.330 (95% CI = 0.27–0.38) and 0.5000, respectively. Lung ultrasound provided highly accurate AUC, sensitivity, and specificity in detecting TTN. Large-scale studies are warranted in the future to confirm these results.
Citation: He L, Sun Y, Sheng W, Yao Q (2021) Diagnostic performance of lung ultrasound for transient tachypnea of the newborn: A meta-analysis. PLoS ONE 16(3): e0248827. https://doi.org/10.1371/journal.pone.0248827
Editor: Ahmed Negida, Zagazig University, EGYPT
Received: September 9, 2020; Accepted: March 7, 2021; Published: March 29, 2021
Copyright: © 2021 He et al. This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Data Availability: All relevant data are within the manuscript and its Supporting information files.
Funding: This work was supported by the National Key Research and Development Program of China (Grant No. 2016YFC1000500).
Competing interests: The authors have declared that no competing interests exist.
Introduction
Transient tachypnea of the neonate (TTN), also designated as wet lung, was first defined as early as in 1966 and was the consequence of the clinical manifestation caused by the postponed clearance of fetal lung fluid [1]. TTN is one of the most frequent causes of respiratory distress in neonates and is generally transient. The symptoms of TTN overlap with the manifestations of a wide variety of pathophysiologic states and usually improve in 24 or 48 h. However, the respiratory disorder may sporadically become more severe. The diagnosis of neonatal TTN has always been a dilemma due to the lower sensitivity and specificity of clinical signs and symptoms [2].
Since 2007, lung ultrasound for the diagnosis of neonatal lung diseases, such as neonatal respiratory distress and TTN, has been emerging as a modality of diagnosis gradually accepted in recent years. Previous studies have shown the precise and stable performance of lung ultrasound in diagnosing neonatal lung pathology [3–6]. Chest x-ray and computed tomography (CT) have been widely used to diagnose lung pathology and identify the pathogenesis of TTN [7], but they lead to radiation exposure of neonates. Moreover, lung ultrasound is less expensive, easily trainable for operators, and faster for obtaining results. Although it cannot completely substitute the chest x-ray, its use may reduce the use of chest x-ray in clinical settings with clear benefits.
Recently, several studies demonstrated that lung ultrasound obtained a significantly improved diagnostic accuracy for TTN [5,8]. However, the diagnostic performance of lung ultrasound for TTN has not been studied systemically to date. Therefore, the present study was conducted to investigate the diagnostic performance of lung ultrasound for TTN.
Material and methods
This study was performed according to the Handbook of Preferred Reporting Items for Systematic Reviews and Meta-analyses 2019 Statement [9].
Literature search
PubMed, Medline, the Cochrane Library, and Embase were searched for the relevant literature without any restriction in terms of language and time until January 31, 2021. The joint and individual key terms such as “Ultrasound,” “Ultrasonic,” “Transient Tachypnea,” “Infant,” “Newborn,” “Infantile,” and “Neonatal” were used for searching the databases. To include more studies, all relevant references and books were explored. Google Scholar was used to search the literature that referenced relevant studies.
Eligibility criteria
The eligibility criteria for the present meta-analysis were as follows: (1) infants that diagnosed with transient tachypnea; (2) detection was performed using lung ultrasound; (3) studies reported sufficient results on constructing 2 × 2 contingency tables; (5) studies were published in English; and (6) studies conducted on the same population with more detailed data or most recently published studies.
Case reports, letters, comments, reviews, studies conducted on animal models or experiments in vitro, studies not published in English, and studies for which data were not available were excluded from the analysis.
Data extraction
All studies obtained from the aforementioned databases were evaluated independently by two authors. Any disagreements on their inclusion were discussed and resolved with the help of a third author. All the needed data were extracted using standardized tables. Any disagreements were discussed with a third reviewer until a consensus was reached. For each study meeting the eligibility criteria, the following data were extracted: characteristics of the studies (first author, published year, country, etc.), features of participants (age, nation, sex ratio, etc.), features of lung ultrasound, and true-negative (TN), false-negative (FN), true-positive (TP), and false-positive (FP) results for each study.
The right and left lungs were analyzed separately, and an independent diagnosis was made for each lung. A normal lung was defined as a thin, hyperechoic pleural line with normal pleural sliding, predominantly horizontal A-lines and possibly a few nonconfluent B-lines due to the substantial liquid content of the neonatal lung. TTN was defined as an interstitial syndrome with either diffuse noncompact B-lines or a gradient of echogenicity between inferior and superior areas corresponding to the double-lung point.
Quality assessment
The quality assessment was independently conducted and crosschecked by two authors with the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2) [10]. The quality assessment comprised four domains: (1) selection of participants; (2) index test, which described the conduction and interpretation of the results; (3) reference standard, which described the conduction of reference standard and interpretation of the results; and (4) flow of the participant inclusion and exclusion.
Statistical analysis
The sensitivity and specificity of lung ultrasound for each study was assessed using TN, FN, TP, and FP. The pooled sensitivity, pooled specificity, and respective 95% confidence intervals (CIs) across all included studies were summarized using the random-effects models. The standard error (SE) and 95% CI, summary receiver operating characteristic curve (SROC), and area under the curve (AUC) for each study were also calculated. The DerSimonian–Laird random-effects models were employed to assess the AUC of the SROC curves due to heterogeneity. The 95% CIs of the pooled metric were compared to assess the relative performance of the technique. The I2 statistics were calculated to evaluate the consistency of the effect sizes. The heterogeneity for each study was categorized as low, moderate, and high according to the values of I2 being lower than 25%, between 25% and 50%, and higher than 75%, respectively [11]. Begg’s rank correlation [12] and Egger’s weighted regression methods [13] were used to assess the publication bias. Review Manager (version 5.3, The Cochrane Collaboration, Oxford, UK) and Stata 15.0 (Stata Corporation, TX, USA) were used for data analyses. Stata 15.0 was also employed to calculate the result for Begg’s and Egger’s tests. P values less than 0.05 indicated statistically significant differences.
Results
Study selection
The search strategy yielded 126 studies as potentially relevant studies; 47 studies were excluded due to duplication. Of the remaining 79 studies, 57 were excluded after browsing the titles or abstracts. Ultimately, seven studies [5,8,14–18] were included for data extraction and analysis. The flow chart for study selection is presented in Fig 1.
Study characteristics
Seven studies (1514 participants) were included in the present meta-analysis. Table 1 shows the characteristics of the study participants; the sample size ranged from 26 to 1013. The studies were published from 2007 to 2019. Two of the studies were performed in China [15,16], two in Italy [8,14], one in India [17], one in Egypt [5], and one in France [18].
Study quality assessment
Two reviewers independently evaluated each included study in the present meta-analysis according to the guideline for QUADAS-2. For all the items of QUADAS-2, almost each domain had unclear risks due to missing information or non-blinded selection of grouping. None of the domains was judged as high risk. The results for quality assessment using QUADAS-2 are presented in Fig 2.
Observation indexes
The majority of the studies reported the observation indexes for lung ultrasound, including pleural-, A-, and B-lines, as well as the double-lung point (DLP). Five studies reported the diagnostic performance of DLP for the TTN [8,14,15,17,18], and two reported the results on B-lines [5,16].
Diagnostic accuracy of DLP for TTN
The pooled diagnostic accuracies of DLP in diagnosing TTN are shown in Figs 3–8. The DLP showed moderate sensitivity as 0.67 (95% CI = 0.63–0.71) and better specificity as 0.97 (95% CI = 0.95–0.98). The pooled area under the SROC curve was 0.9906 with an SE of 0.0058 (Fig 9). The forest plots suggested that the heterogeneity was high with almost all the I2 values exceeding 75%.
Subgroup analysis
The pooled results for the studies grouped by study design and country are shown in S1–S6 Figs. The studies from Asian countries (S1 Fig) had similar sensitivity (0.67, 95% CI = 0.63–0.71) compared with the studies conducted in Europe (0.65, 95% CI = 0.60–0.70, S7 Fig).
Diagnostic accuracy of B-lines for TTN
Two studies reported the data on the diagnostic accuracy of B-lines for TTN. The results are presented in S5 and S6 Figs. The diagnostic accuracy of B-lines for TTN was observed with a lower sensitivity of 0.330 (95% CI = 0.27–0.38), and the AUC was 0.5000.
Meta-regression and subgroup analyses
Several covariates were included for the meta-regression: study design (case–control versus prospective studies), location of the studies (Asia versus Europe), and operator for lung ultrasound (radiologists versus others). The meta-regression analysis demonstrated that the operator might explain the heterogeneity observed (Table 2).
Publication bias
No publication bias was observed (all P values were >0.05) according to Begg’s rank correlation analysis and Egger’s weighted regression tests (S1 Table).
Discussion
This meta-analysis was novel in evaluating the diagnostic value of combined lung ultrasound for detecting TTN. Seven studies reported the diagnostic performance of DLP for TTN, and two reported the results on B-lines. The pooled results from seven studies demonstrated that lung ultrasound provided accurate performance for diagnosing TTN by DLP with summarized sensitivity and specificity as 0.67 (95% CI = 0.63–0.71) and 0.97 (95% CI = 0.95–0.98), respectively. The pooled SROC was 0.9800.
Breathing difficulty was one of the most common neonatal critical diseases that needed immediate therapy. TTN was one of the most common reasons for breathing difficulty and could lead to severe neonatal dyspnea. Previous studies showed that TTN accounted for approximately 33%–50% of neonatal breathing difficulty in patients [20,21]. The accurate diagnostic method for TTN would be the crucial element to improve the prognosis of patients. In previous studies [1,2], lung ultrasound showed high sensitivity and specificity in diagnosing TTN and was effective in investigating the main neonatal respiratory diseases. In this study, lung ultrasound was demonstrated to be a practical tool for diagnosing TTN. Some patients had a normal chest x-ray (CXR) despite having the clinical symptoms of TTN. Chest CXR and CT scan have been widely used to find the cause of respiratory distress in neonates. CXR and CT were broadly used to eliminate differential diagnoses or complications of underlying diseases. However, CXR and CT led to radiation exposure of neonates, making it difficult for the neonatologist. The avoidance of ionizing radiation could be done through prudent clinical use. Lung ultrasound was a less ideal tool for examining the normal aerated lungs because ultrasound could not travel smoothly through the air. Lung ultrasound is highly operator dependent; an inherent source of potential error may exist, although using a standard approach helps limit operator dependency. The evaluation of the lung became possible due to advances in ultrasound technology in the last few years. Moreover, the international evidence-based recommendations standardized the main indications of lung ultrasound [22] and also verified ultrasound superiority over CXR in diagnosing TTN [15]. In the clinical settings, the usefulness and the possible impact of lung ultrasound in daily practice might tremendously benefit newborns.
The possible etiology for TTN may be the deferred elimination for pulmonary fluid caused by the immaturity or postpone of the pulmonary epithelium transformed from chloride secretion to enable sodium chloride reabsorption. The respiratory symptoms of TTN are usually transient and relatively mild, and the treatment is usually oxygen supplementation alone. DLP is the demarcation point formed between the upper and lower lungs on an ultrasound due to the differences in the severity or nature of lesions. In the present study, DLP was presented in a majority of newborns with TTN. In the past, the appearance of DLP was deemed a specific and sensitive sign for TTN. In the present study, DLP was found to have higher accuracy for TTN. DLP, exposing a higher water content at the bases compared with the apical regions, may be interpreted by recalling the dynamics of lung water drainage in hours after delivery.
The present study had some limitations. First, only seven studies were included, and most of the studies had limited sample size. The small sample size might have reduced the credibility and stability of the results. Second, the heterogeneity in the analysis remained high due to the involvement of different types of operators for lung ultrasound in the studies. The differences in operators in studies might have led to heterogeneity and reduction in the stability of the results. Third, various ultrasound devices were used to assess TTN. The different parameters of ultrasound equipment might have also caused the heterogeneity. However, it might not be possible to ensure that all parameters were kept constant. Fourth, language bias might also exist because all included studies were published in English only.
Conclusions
In conclusion, lung ultrasound had highly accurate AUC, sensitivity, and specificity in detecting TTN. Nevertheless, the conclusions were based on only seven studies, and hence the heterogeneity needs to be taken into account. More studies should be conducted in the future to further assess and compare the use of lung ultrasound for detecting TTN.
Supporting information
S1 Fig. Subgroup analysis of studies from Asian countries using the pooled ROC curve of the double-lung point for transient tachypnea of the neonate.
https://doi.org/10.1371/journal.pone.0248827.s002
(DOC)
S2 Fig. Subgroup analysis of studies from Asian countries using the pooled area under the SROC curve of the double-lung point for transient tachypnea of the neonate.
https://doi.org/10.1371/journal.pone.0248827.s003
(DOC)
S3 Fig. Subgroup analysis of studies conducted in Europe using the pooled ROC curve of the double-lung point for transient tachypnea of the neonate.
https://doi.org/10.1371/journal.pone.0248827.s004
(DOC)
S4 Fig. Subgroup analysis of studies conducted in Europe using the pooled area under the SROC curve of the double-lung point for transient tachypnea of the neonate.
https://doi.org/10.1371/journal.pone.0248827.s005
(DOC)
S5 Fig. Summary of the pooled ROC curve of B-lines for transient tachypnea of the neonate.
https://doi.org/10.1371/journal.pone.0248827.s006
(DOC)
S6 Fig. Summary of the pooled area under the SROC curve of B-lines for transient tachypnea of the neonate.
https://doi.org/10.1371/journal.pone.0248827.s007
(DOC)
S7 Fig. Subgroup analysis of studies conducted in Europe of the pooled ROC curve of double-lung point for transient tachypnea of the neonate.
https://doi.org/10.1371/journal.pone.0248827.s008
(DOC)
S1 Table. Publication bias of summarized outcomes.
https://doi.org/10.1371/journal.pone.0248827.s009
(DOC)
References
- 1. Avery ME, Gatewood OB, Brumley G. Transient tachypnea of newborn. Possible delayed resorption of fluid at birth. Am J Dis Child. 1966;111:380–385. pmid:5906048
- 2. Elemraid MA, Muller M, Spencer DA, Rushton SP, Gorton R, Thomas MF, et al. Accuracy of the interpretation of chest radiographs for the diagnosis of paediatric pneumonia. PLoS One. 2014;9:e106051. pmid:25148361
- 3. Lichtenstein DA, Mauriat P. Lung Ultrasound in the Critically Ill Neonate. Curr Pediatr Rev. 2012;8:217–223. pmid:23255876
- 4. Heuvelings CC, Bélard S, Familusi MA, Spijker R, Grobusch MP, Zar HJ. Chest ultrasound for the diagnosis of paediatric pulmonary diseases: a systematic review and meta-analysis of diagnostic test accuracy. Br Med Bull. 2019;129:35–51. pmid:30561501
- 5. Ibrahim M, Omran A, AbdAllah NB, Ibrahim M, El-Sharkawy S. Lung ultrasound in early diagnosis of neonatal transient tachypnea and its differentiation from other causes of neonatal respiratory distress. J Neonatal Perinatal Med. 2018;11:281–287. pmid:30040751
- 6. Elsayed YN. Lung Ultrasound as a New Technique for Diagnosis of Neonatal Respiratory Diseases. Neonatal Netw. 2018;37:224–232. pmid:30567920
- 7. Sharma D, Farahbakhsh N. Role of chest ultrasound in neonatal lung disease: a review of current evidences. J Matern Fetal Neonatal Med. 2019;32:310–316. pmid:28870125
- 8. Vergine M, Copetti R, Brusa G, Cattarossi L. Lung ultrasound accuracy in respiratory distress syndrome and transient tachypnea of the newborn. Neonatology. 2014;106:87–93. pmid:24819542
- 9. Moher D, Liberati A, Tetzlaff J, Altman DG. Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement. PLoS Med. 2009;6:e1000097. pmid:19621072
- 10. Whiting PF, Weswood ME, Rutjes AW, Reitsma JB, Bossuyt PN, Kleijnen J. Evaluation of QUADAS, a tool for the quality assessment of diagnostic accuracy studies. BMC Med Res Methodol. 2006;6:9. pmid:16519814
- 11. Higgins JP, Thompson SG, Deeks JJ, Altman DG. Measuring inconsistency in meta-analyses. Bmj. 2003;327:557–560. pmid:12958120
- 12. Begg CB, Mazumdar M. Operating characteristics of a rank correlation test for publication bias. Biometrics. 1994;50:1088–1101. pmid:7786990
- 13. Egger M, Davey Smith G, Schneider M, Minder C. Bias in meta-analysis detected by a simple, graphical test. Bmj. 1997;315:629–634. pmid:9310563
- 14. Copetti R, Cattarossi L. The ’double lung point’: an ultrasound sign diagnostic of transient tachypnea of the newborn. Neonatology. 2007;91:203–209. pmid:17377407
- 15. Liu J, Wang Y, Fu W, Yang CS, Huang JJ. Diagnosis of neonatal transient tachypnea and its differentiation from respiratory distress syndrome using lung ultrasound. Medicine (Baltimore). 2014;93:e197. pmid:25501071
- 16. Liu J, Chen XX, Li XW, Chen SW, Wang Y, Fu W. Lung Ultrasonography to Diagnose Transient Tachypnea of the Newborn. Chest. 2016;149:1269–1275. pmid:26836942
- 17. Rachuri H, Oleti TP, Murki S, Subramanian S, Nethagani J. Diagnostic Performance of Point of Care Ultrasonography in Identifying the Etiology of Respiratory Distress in Neonates. Indian J Pediatr. 2017;84:267–270. pmid:28108881
- 18. Grimaldi C, Michel F, Brévaut-Malaty V, Hassid S, Nicaise C, Puech B, et al. Thoracic ultrasound accuracy for the investigation of initial neonatal respiratory distress. Arch Pediatr. 2019;26:459–465. pmid:31630903
- 19. Grimaldi C, Michel F, Brevaut-Malaty V, Hassid S, Nicaise C, Puech B, et al. Thoracic ultrasound accuracy for the investigation of initial neonatal respiratory distress. Arch Pediatr. 2019;26(8):459–465. Epub 2019-11-01. pmid:31630903.
- 20. Latzin P, Roth S, Thamrin C, Hutten GJ, Pramana I, Kuehni CE, et al. Lung volume, breathing pattern and ventilation inhomogeneity in preterm and term infants. PLoS One. 2009;4:e4635. pmid:19247491
- 21. Caserta MT, Yang H, Bandyopadhyay S, Qiu X, Gill SR, Java J, et al. Measuring the Severity of Respiratory Illness in the First 2 Years of Life in Preterm and Term Infants. J Pediatr. 2019;214:12–19.e13. pmid:31377041
- 22. Volpicelli G, Elbarbary M, Blaivas M, Lichtenstein DA, Mathis G, Kirkpatrick AW, et al. International evidence-based recommendations for point-of-care lung ultrasound. Intensive Care Med. 2012;38:577–591. pmid:22392031