External Suction versus Water Seal after Selective Pulmonary Resection for Lung Neoplasm: A Systematic Review

  • Tong Qiu,

    Affiliation Department of Thoracic Surgery, The Affiliated Hospital of Medical College, Qingdao University, Qingdao, China

  • Yi Shen,

    Affiliation Department of Thoracic Surgery, The Affiliated Hospital of Medical College, Qingdao University, Qingdao, China

  • Ming-zhao Wang,

    Affiliation Department of Thoracic Surgery, The Affiliated Hospital of Medical College, Qingdao University, Qingdao, China

  • Yao-peng Wang,

    Affiliation Department of Thoracic Surgery, The Affiliated Hospital of Medical College, Qingdao University, Qingdao, China

  • Dong Wang,

    Affiliation Department of Thoracic Surgery, The Affiliated Hospital of Medical College, Qingdao University, Qingdao, China

  • Zi-zong Wang,

    Affiliation Department of Thoracic Surgery, The Affiliated Hospital of Medical College, Qingdao University, Qingdao, China

  • Xiang-feng Jin,

    Affiliation Department of Thoracic Surgery, The Affiliated Hospital of Medical College, Qingdao University, Qingdao, China

  • Yu-cheng Wei

    qt990552@gmail.com

    Affiliation Department of Thoracic Surgery, The Affiliated Hospital of Medical College, Qingdao University, Qingdao, China

Abstract

Objective

To evaluate whether external suction is more advantageous than water seal in patients undergoing selective pulmonary resection (SPR) for lung neoplasm.

Summary of Background Data

Whether external suction should be routinely applied in postoperative chest drainage is still unclear, particularly for lung neoplasm patients. To most surgeons, the decision is based on their clinical experience.

Methods

Randomized control trials were selected. The participants were patients undergoing SPR with lung neoplasm. Lung volume reduction surgery and pneumothorax were excluded. Suction versus non-suction for the intervention. The primary outcome was the incidence of persistent air leak (PAL). The definition of PAL was air leak for more than 3–7 days. The secondary outcomes included air leak duration, time of drainage, postoperative hospital stay and the incidence of postoperative pneumothorax. Studies were identified from literature collections through screening. Bias was analyzed and meta-analysis was used.

Results

From the 1824 potentially relevant trials, 6 randomized control trials involving 676 patients were included. There was no difference between external suction and water seal in decreasing the incidence of PAL [95% confidence interval (CI) 0.81−2.16; z = 1.10; P = 0.27]. Regarding secondary outcomes, there were no differences in time of drainage (95% CI−0.36−1.56, P = 0.22), postoperative hospital stay (95% CI -.31−.54, P = 0.87) or incidence of postoperative pneumothorax (95% CI 0.18−.02, P = 0.05) between external suction and water seal.

Conclusions

For participants, no differences are identified in terms of PAL incidence, drainage time, length of postoperative hospital stay or incidence of postoperative pneumothorax between external suction and water seal. The bias analysis should be emphasized. To the limitations of the bias and methodological differences among the included studies, we have no recommendation on whether external suction should be routinely applied after lung neoplasm SPR. More high-quality randomized controlled trials are needed.

Systematic Review Registration

None.

Introduction

Chest drainage is the most important management method in pulmonary surgery. For lung neoplasm patients who undergo selective pulmonary resection (SPR), whether external suction should be applied is one of the major controversies. For most surgeons, the decision is made based on their experience. There are two contrasting viewpoints: (1) external suction appears to restore the negative intra-pleural pressure, eliminate residual space and expedite the fullest lung expansion as its major benefits [1]; and (2) non-suction, a water seal for example, is able to avoid the higher incidence of air leaks [2]. Generally, Lung neoplasm patients maintain better pulmonary function than severe emphysema or pneumothorax patients. We believe that the issue of suction should be analyzed independently for lung neoplasms rather than in association with other pulmonary air leak-associated diseases.

In the past years, many retrospective studies have trended toward routine non-suction management [3], [4]. Randomized control trials (RCTs) have reported different conclusions on this issue [5], [6]. Recently, investigators have focused on electronic devices with a controlled form of suction. This new system has been gradually popularized, but a general drainage system with or without suction should still be applied in the long term. The aim of this systematic review was to evaluate whether external suction was more advantageous than water seal in patients undergoing SPR for lung neoplasm.

Methods

Criteria for Considering Studies

We selected RCTs as the type of study. No language or publication date limits were set. The participants were patients undergoing SPR who were diagnosed with lung neoplasm. Studies including lung volume reduction surgery were excluded due to an initial association with poor pulmonary function. Pneumothorax studies were excluded because of the presence of air leaks. For the intervention, suction was compared with non-suction (water seal). Considering the different algorithms of postoperative management among institutions, we considered that suction beginning from chest closure during the operation [postoperative day (POD) 0] or from POD 2 was the same. The primary outcome was the incidence of persistent air leak (PAL). The definition of PAL was air leak for more than 3− days. The secondary outcomes included air leak duration, time of drainage, postoperative hospital stay and the incidence of postoperative pneumothorax.

Search Methods for Identification

Two independent authors searched MEDLINE (http://www.ncbi.nlm.nih.gov), EMBASE (http://www.embase.com), and listed references. We also hand searched conference proceedings to identify published and unpublished trials. To minimize regional bias, we also searched the Chinese Biomedical Literature Database.

Data Collection and Analysis

Titles and abstracts identified by the electronic and manual searches were evaluated by two independent reviewers. We carefully evaluated the identified studies to determine whether they met the inclusion criteria. Any disagreement was resolved by consensus. Complete information, including methods, participant characteristics, intervention, groups, results, and follow-up time, was entered in a paper form that was specifically designed for this purpose. Considering the potential heterogeneity of studies, we attempted only a narrative synthesis at this stage.

Risk of Bias Assessment of the Included Studies

To estimate the validity of the included studies, the risk of bias in the results of each eligible study was assessed with domain-based evaluation according to the criteria of the Cochrane Handbook for Systematic Reviews of Interventions. The criteria for judging the risk of bias included random sequence generation and allocation concealment (selection bias), blinding of participants and personnel (performance bias), blinding of outcome assessment (detection bias), incomplete outcome data (attrition bias) and selective reporting (reporting bias).

Statistical Analysis and Meta-Analysis

All the included studies were aligned to compare the characteristics of the participants, the interventions and the outcomes. The meta-analysis methods used for dichotomous and continuous data were Mantel-Haenszel and inverse variance, respectively. Heterogeneity was tested using the chi-square test (χ2 test). The meta-analysis was performed using a fixed-effects model when the heterogeneity test p>0.10. A random-effects model was used if heterogeneity existed, and the reasons for heterogeneity were analyzed. Descriptive analysis was implemented instead of meta-analysis if there was high heterogeneity or if there was no qualification to perform a meta-analysis. Odds ratios (ORs), relative risks (RRs) and mean differences (MDs) were the principal measures of effect and were presented as a point estimate with 95% confidence intervals (CIs) and P values in parentheses. Reviewer Manager 5.2.3 (The Cochrane Collaboration, Wintertree Software Inc., Canada) statistical software was used. We considered P values less than 0.05 to be statistically significant.

No protocol was used for this systematic review.

Results

Literature Screening and Risk of Bias

A total of 1824 results were obtained with the search strategy from MEDLINE, EMBASE and the Chinese Biomedical Literature Database. After primary screening, 1780 articles were excluded. After secondary screening, 38 were excluded, and 6 RCTs were included [1], . A total of 676 patients were included in this analysis. The criteria and flow of selection and screening are shown in Fig. 1. The characteristics of the included studies are shown in Table 1.

Two reviewers assessed the risk bias of the included studies. Alphonso (2005) and Cerfolio (2001) were found to have a high risk of bias due to incomplete data, while the other 4 studies were deemed unclear (Table 2). All the studies mentioned the blinding of surgeons; however, the blinding of outcome assessors in each study was not reported. Only one study was reported to be free of selective reporting, while freedom from selective reporting was not reported in the other 5 studies. The graph of risk bias for each included study is shown in Fig. 2.

thumbnail
Figure 2. Graph of the risk of bias for the included studies.

This graph is based on the results of domain-based evaluation according to the criteria of the Cochrane Handbook for Systematic Reviews of Interventions.

https://doi.org/10.1371/journal.pone.0068087.g002

Meta-Analysis

Regarding the primary outcome, PAL incidence data were calculated from Brunelli (2004), Brunelli (2012), Cerfolio (2001), Alphonso (2005) and Prokakis (2008). According to the participant characteristics, the first 3 studies were placed into a subgroup of “patients with air leak only”, and the last 2 studies were placed into a subgroup of “patients included air leak” (Fig. 3). There was no difference between external suction and water seal in decreasing the incidence of PAL (total events: RR = 1.32, 95% CI 0.81−2.16, z = 1.10, P = 0.27). There was no statistical heterogeneity between the trials (χ2 = 7.65; df  = 4; P  = 0.11; I2 = 48%); therefore, a random-effects model was adopted.

thumbnail
Figure 3. Meta-analysis of external suction versus water seal on the incidence of PAL.

Subgroup 1: patients with air leak only. Subgroup 2: patients included air-leaks. M-H, Mantel-Haenszel. Events means patient with PAL.

https://doi.org/10.1371/journal.pone.0068087.g003

The secondary outcomes time of drainage, postoperative hospital stay and postoperative pneumothorax were analyzed by meta-analysis. There was no statistical heterogeneity in these 3 parameters (fixed model, heterogeneity p>0.10). Because of a lack of data on the duration of air leaks, we excluded this item from the meta-analysis. Data on the drainage time was calculated from Brunelli (2012), Marshall (2002) and Prokakis (2008) (Fig. 4). The result showed no difference in decreasing the drainage time (MD = 0.60, 95% CI −0.36−1.56, z = 1.22, P = 0.22). Additionally, there was no difference in the postoperative hospital stay with the same studies (MD = 0.12, 95% CI −1.31−1.54, z = 0.16, P = 0.87) (Fig. 5). The postoperative pneumothorax data were calculated from Alphonso (2005), Marshall (2002), and Prokakis (2008) (Fig. 6) and showed no difference (OR = 0.42, 95% CI 0.18–.02, z = 1.92, P = 0.05).

thumbnail
Figure 4. Meta-analysis of external suction versus water seal on the time of drainage.

IV, inverse variance method.

https://doi.org/10.1371/journal.pone.0068087.g004

thumbnail
Figure 5. Meta-analysis of external suction versus water seal on the postoperative hospital stay.

IV, inverse variance method.

https://doi.org/10.1371/journal.pone.0068087.g005

thumbnail
Figure 6. Meta-analysis of external suction versus water seal on the incidence of pneumothorax.

M-H, Mantel-Haenszel method. Events means patient with postoperative pneumothorax.

https://doi.org/10.1371/journal.pone.0068087.g006

Discussion

Chest tube management is a basic skill for thoracic surgeons. One of the most interesting areas of focus is whether external suction should be applied to a chest drainage system. External suction applied after SPR was derived from lung volume reduction surgery based on clinical experience. Currently, many surgeons prefer external suction after lung neoplasm SPR as a routine procedure. In their opinion, external suction is able to maintain the negative pressure in the thoracic cavity, which reduces the residual cavity and promotes lung expansion. Therefore, external suction might reduce the incidence of persistent air leaks. Since 2000, several RCTs on this topic have been reported. Sanni et al reported a review of the published RCTs and indicated that no studies found in favor of suction to reduce the incidence of air leaks. However, new studies should be added [10]. Recently, investigators have focused on a new device with visually controlled suction pressure, which seems to be more beneficial for the natural physiology of the thoracic cavity. However, due to the portability and cost of this new product, a general drainage system with or without external suction is still the major issue in chest tube management, particularly in developing countries. Debate needs to be settled.

Primary Outcome

PAL is still one of the most common postoperative complications. The common definition of PAL is a postoperative air leak sustained for more than 5 days [11]. Due to the publication time span of the included studies, we considered that the definition of PAL was air leak for more than 3–7 days. According to the result of the meta-analysis, there is no difference between external suction and water seal in decreasing the incidence of PAL. One of the reasons might be: Cerfolio RJ et al suggested that low pulmonary function is a key risk factor for PAL [12], while four of the included studies showed normal preoperative pulmonary functioning in patients [1], [6][7], [9]. According to the NCCN Guidelines for Non-Small Cell Lung Cancer, version 1.2013, a lung neoplasm with poor pulmonary reserve is appropriate for segmentectomy or wedge resection; however the patients in our study were underwent SPR. In our study, cases of pneumothorax, severe emphysema and other poor pulmonary function diseases were excluded, thus the quality of the lungs was relatively normal, and patients with lung neoplasm who underwent SPR were able to tolerate the reduction of pulmonary function. The other reason is that the application of staples or pulmonary air leak spot suturing is able to reduce the risk of PAL [13]. Furthermore, the application of surgical sealant during the operation decreases the potential risk of PAL [14], although none of the included studies stated using this technique.

Secondary Outcomes

Regarding secondary outcomes, external suction provided no advantage over water seal in decreasing the time of drainage or postoperative hospital stay. In chest tube management, chest radiographs and observation of the chest drainage system are both necessary. In each included study, the indication for chest tube removal was similar. As shown in Fig. 4, a digital drainage system was used by Brunelli (2012), which may beneficially control pleural space pressure, while a general drainage system was used by Marshall (2002) and Prokakis (2008). Regarding the postoperative hospital stay, patients with air leak that persisted for more than 8 days were discharged with a Heimlich valve by Marshall (2002), while the other two studies performed no intervention at patient discharge.

External suction is a practical treatment for postoperative pneumothorax [15]. In our study, the results suggested that there was no difference between external suction and water seal in decreasing the incidence of postoperative pneumothorax. In recent years, two meta-analysis on suction versus water seal were published. Coughlin SM et al reported that water seal was associated with a significantly increased incidence of postoperative pneumothorax [16]. Deng B et al suggested that suction could reduce the occurrence of postoperative pneumothorax resulting from early air leak [17]. Through a careful review, we found that both studies included a study by Ayed AK in the term of postoperative pneumothorax. The weights of Ayed’s study in those two studies were 32.60% and 52.98%, respectively. Participants in Ayed’s research primarily underwent surgery for spontaneous pneumothorax, which was not in accordance with the inclusive criteria [18]. Thus, we excluded Ayed’s article during level 1 screening.

Limitations

The PRISMA system was used to rate the overall quality of this research, but there are some limitations. One weakness is that there is no standard procedure in chest tube management. This vague management leads to different definitions of PAL and suction pressure. Additionally, which level of pneumothorax was confirmed as a complication was not mentioned in all included studies. Secondly, we should carefully consider the quality of the included studies. There was a high risk of bias due to incomplete outcome data in the studies of Alphonso (2005) and Cerfolio (2001). The heterogeneity test for each meta-analysis was well accepted. However, in Fig. 3, it should be noted that the subgroup heterogeneities were P = 0.08 and P = 0.40, respectively, while the total heterogeneity was P = 0.11. We found that Cerfolio (2004) may be the source of the heterogeneity (after excluding this study, the heterogeneity was P = 0.84). In our opinion, the small sample size of this study may impair the results. In this section, we used a random-effects model for meta-analysis and tolerated the heterogeneity. For the duration of air leak, only one included study reported the data. Therefore, more data sources are needed.

Conclusion

For patients with lung neoplasm who underwent selective pulmonary resection, no differences were identified in terms of PAL incidence, drainage time, length of postoperative hospital stay or incidence of postoperative pneumothorax between external suction and water seal for chest tube management. The bias analysis of the included studies should be emphasized. To the limitations of the bias and methodological differences among the included studies, we have no strong recommendation on whether external suction should be routinely applied after selective pulmonary resection in lung neoplasm patients. A large-scale, well-designed RCT is needed to address this clinical issue.

Acknowledgments

We would like to thank the Chinese Cochrane Centre for systematic review instruction and American Journal Experts for English language editing.

Author Contributions

Conceived and designed the experiments: TQ YCW YS. Performed the experiments: TQ DW ZZW XFJ. Analyzed the data: MZW YPW. Contributed reagents/materials/analysis tools: YPW DW ZZW XFJ. Wrote the paper: TQ YCW.

References

  1. 1. Brunelli A, Monteverde M, Borri A, Salati M, Marasco RD, et al. (2004) Comparison of water seal and suction after pulmonary lobectomy: a prospective randomized trial. Ann Thorac Surg 77: 1932–7.
  2. 2. Enerson DM, Mclntyre J (1966) A comparative study of physiology and physics of pleural drainage systems. J Thorac Cardiovasc Surg 52: 40–6.
  3. 3. Antanavicus G, Lamb J, Papasavas P, Caushaj P (2005) Initial chest tube management after pulmonary resection. Am Surg 71: 416–9.
  4. 4. Cerfolio RJ, Bryant AS, Singh S, Bass CS, Bartolucci AA (2005) The management of chest tubes in patients with a pneumothorax and an air leak after pulmonary resection. Chest 128: 816–20.
  5. 5. Cerfolio RJ, Bass C, Katholi CR (2001) Prospective randomized trial compares suction versus water seal for air leaks. Ann Thorac Surg 71: 1613–7.
  6. 6. Brunelli A, Salati M, Pompili C, Refai M, Sabbatini A (2012) Regulated tailored suction vs regulated seal: a prospective randomized trial on air leak duration. Eur J Cardiothorac Surg 43: 899–904.
  7. 7. Marshall MB, Deeb ME, Bleier JI, Kucharczuk JC, Friedberg JS, et al. (2002) Suction vs water seal after pulmonary resection: a randomized prospective study. Chest 121: 831–5.
  8. 8. Alphonso N, Tan C, Utley M, Cameron R, Dussek J, et al. (2005) A prospective randomized controlled trial of suction versus non-suction to the under-water seal drains following lung resection. Eur J Cardiothorac Surg 27: 391–4.
  9. 9. Prokakis C, Koletsis EN, Apostolakis E, Panagopoulos N, Kouki HS, et al. (2008) Routine suction of intercostal drains is not necessary after lobectomy: a prospective randomized trial. World J Surg 32: 2336–42.
  10. 10. Sanni A, Critchley A, Dunning J (2006) Should chest drains be put on suction or not following pulmonary lobectomy? Interactive Cardiovascular and Thoracic Surgery 5: 275–8.
  11. 11. Brunelli A, Beretta E, Cassivi SD, Cerfolio RJ, Detterbeck F, et al. (2011) Consensus definitions to promote an evidence-based approach to management of the pleural space. A collaborative proposal by ESTS, AATS, STS, and GTSC. Eur J Cardiothorac Surg 40: 291–7.
  12. 12. Cerfolio RJ, Tummala RP, Holman WL, Zorn GL, Kirklin JK, et al. (1998) A prospective algorithm for the management of airleaks after pulmonary resection. Ann Thorac Surg 66: 1726–31.
  13. 13. Rice TW, Okereke IC, Blackstone EH (2002) Persistent air-leak following pulmonary resection. Chest Surg Clin N Am 12: 529–39.
  14. 14. Malapert G, Hanna HA, Pages PB, Bernard A (2010) Surgical sealant for the prevention of prolonged air leak after lung resection: meta-analysis. Ann Thorac Surg 90: 1779–85.
  15. 15. Parlak M, Uil SM, van den Berj JW (2012) A prospective, randomised trial of pneumothorax therapy: manual aspiration versus conventional chest tube drainage. Respir Med 106: 1600–5.
  16. 16. Coughlin SM, Emmerton-Coughlin HM, Malthaner R (2012) Management of chest tubes after pulmonary resection: a systematic review and meta-analysis. Can J Surg 55: 264–70.
  17. 17. Deng B, Tan QY, Zhao YP, Wang RW, Jiang YG (2010) Suction or non-suction to the underwater seal drains following pulmonary operation: meta-analysis of randomized controlled trials. Eur J Cardiothorac Surg 38: 210–5.
  18. 18. Ayed AK (2003) Suction versus water seal after thoracoscopy for primary spontaneous pneumothorax: prospective randomized study. Ann Thorac Surg 75: 1593–6.