Erroneous intracranial pressure measurements from simultaneous pressure monitoring and ventricular drainage catheters

  • Take Notice Technology
  • Published:
Neurocritical Care Aims and scope Submit manuscript

Abstract

The objective of this report is to highlight the potential for false pressure measurements from systems that combine intracranial pressure (ICP) measurement and ventricular drainage. If the ports of the drain become blocked to the extent that they present a high resistance to cerebrospinal fluid flow, then a significant pressure gradient between the inside and outside of the catheter may be established. Thus, any intracatheter transducer will faithfully record a pressure much lower than true ICP. This holds true for catheter tip transducers when the transducer lies inside the catheter. In the absence of flow, however, pressures will equalize; therefore, accurate measurements may be taken if the drain is temporarily closed. We model this situation and provide simulations of expected measurements in such situations; these compare well to observed clinical readings.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Wilkinson HA, Yarzebski J, Wilkinson EC, Anderson FA. Erroneous measurement of intracranial pressure caused by simultaneous ventricular drainage: a hydrodynamic model study. Neurosurgery 1989;24:348–354.

    Article  PubMed  CAS  Google Scholar 

  2. Piek J, Raes P. Pressure-controlled drainage of cerebrospinal fluid: clinical experience with a new type of ventricular catheter (Ventcontrol MTC) and an integrated piezo-resistive sensor at its tip: technical note. Neurosurgery 1996;38:216–218.

    Article  PubMed  CAS  Google Scholar 

  3. Schley D, Billingham J, Marchbanks RJ. A model of in-vivo hydrocephalus shunt dynamics for blockage and performance diagnostics. Math Med Biol 2004; 21:347–368.

    Article  PubMed  CAS  Google Scholar 

  4. Knowlton FP, Starling EH. The influence of variations in temperature and blood pressure on the performance of the isolated mammalian heart. J Physiol 1912;44:206–219.

    PubMed  CAS  Google Scholar 

  5. Luce JM, Huseby JS, Kirk W, Butler JA. Starling resistor regulates cerebral venous outflow in dogs. J Appl Physiol 1982;53(6):1496–1503.

    PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. A. Birch.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Birch, A.A., Eynon, C.A. & Schley, D. Erroneous intracranial pressure measurements from simultaneous pressure monitoring and ventricular drainage catheters. Neurocrit Care 5, 51–54 (2006). https://doi.org/10.1385/NCC:5:1:51

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1385/NCC:5:1:51

Key Words

Navigation