Acessibilidade / Reportar erro

Efficacy of removal of cariogenic bacteria and carious dentin by ablation using different modes of Er:YAG lasers

Abstract

The primary objective of this in vitro study was to evaluate the efficiency of removal of cariogenic bacteria and carious dentin by ablation using two lasers: fluorescence-feedback controlled (FFC) Er:YAG laser and different pulses of Er:YAG laser based on variable square pulse technology (VSPt). The secondary objective was to measure the temperature during laser ablation of carious tissue. Seventy-two extracted human molars were used in this study. Sixty teeth with carious dentin were randomly divided into four experimental groups according to the treatment for caries removal: group 1: 400 µs (FFC group); group 2: super short pulse (SSP group, 50 µs pulse); group 3: medium short pulse (MSP group, 100 µs pulse); group 4: short pulse (SP group, 300 µs pulse) and one positive control group with no treatment. Twelve teeth without carious lesion were used as a negative control group. After caries removal, swabs were taken with cotton pellets and real-time PCR analysis was performed. During caries ablation, a thermal infrared camera was used to measure the temperature changes. In all experimental groups, specimens were free of bacterial contamination after the treatment. In the SSP, MSP and SP groups, temperatures measured during caries ablation were significantly higher compared to temperatures in the FFC group (P<0.001). In this in vitro study, laser treatment for removal of carious dentin and cariogenic bacteria was an efficient treatment modality without causing excessive temperatures that might adversely affect pulp vitality.

Dental caries; Er:YAG laser; Ablation; Real-time PCR; Thermography


Introduction

The aim of caries excavation is to remove dentin contaminated by bacteria without removal of sound tooth structure, and maintain the vitality of the pulp (11. Stoll R, Urban-Klein B, Giacomin P, Loukas A, Jablonski-Momeni A. In vivo assessment of caries excavation with a fluorescence camera compared to direct bacteriological sampling and quantitative analysis using flow cytometry. Laser Med Sci 2015; 30: 843–849, doi: 10.1007/s10103-013-1459-2.
https://doi.org/10.1007/s10103-013-1459-...
). Caries lesions have two distinct substrates with different chemical composition and morphological structures: caries-infected and caries-affected dentin (22. Banerjee A. Minimal intervention dentistry: part 7. Minimally invasive operative caries management: rationale and techniques. Br J Dent 2013; 214: 107–111, doi: 10.1038/sj.bdj.2013.106.
https://doi.org/10.1038/sj.bdj.2013.106...
,33. Almeida Neves A, Coutinho E, Cardoso MV, Lambrechts P, Van Meerbeek B. Current concepts and techniques for caries excavation and adhesion to residual dentin. J Adhes Dent 2011; 13: 7–22, doi: 10.3290/j.jad.a18443.
https://doi.org/10.3290/j.jad.a18443...
). The inner ‘infected dentin’ is a superficial and soft necrotic zone rich in bacteria, incapable of remineralization, with degenerated collagen fibrils that have lost their cross-links (44. Holmgren CJ, Roux D, Domejean S. Minimal intervention dentistry: part 5. Atraumatic restorative treatment (ART)- a minimum intervention and minimally invasive approach for the management of dental caries. Br Dent J 2013; 214: 11–18, doi: 10.1038/sj.bdj.2012.1175.
https://doi.org/10.1038/sj.bdj.2012.1175...
5. Macedo GV, Yamauchi M, Bedran-Russo AK. Effects of chemical cross- linkers on caries-affected dentin bonding. J Dent Res 2009; 88: 1096–1100, doi: 10.1177/0022034509351001.
https://doi.org/10.1177/0022034509351001...
66. Banerjee A, Kellow S, Mannocci F, Cook RJ, Watson TF. An in vitro evaluation of microtensile bond strengths of two adhesive bonding agents to residual dentine after caries removal using three excavation techniques. J Dent 2010; 38: 480–489, doi: 10.1016/j.jdent.2010.03.002.
https://doi.org/10.1016/j.jdent.2010.03....
). If viable bacteria present in the infected dentin remain after caries removal, they may potentially release antigens into the pulp and cause a chronic inflammation reaction (77. Hahn CL, Best AM, Tew JG. Cytokine induction by Streptococcus mutans and pulpal pathogenesis. Infect Immun 2000; 68: 6785–6789, doi: 10.1128/IAI.68.12.6785-6789.2000.
https://doi.org/10.1128/IAI.68.12.6785-6...
). Interestingly, well-sealed margins of the cavity seem to be more crucial for the long-term success of the restoration and pulp vitality than the presence of bacteria in the cavity since clinical follow-ups of bonded restorations placed over soft carious dentin showed that further progression of carious lesion can be arrested (88. Mertz-Fairhurst EJ, Curtis JW, Ergle JW, Ruggeberg FA, Adair SM. Ultraconservative and cariostatic sealed restorations: results at year 10. J Am Dent Assoc 1998; 129: 55–66, doi: 10.14219/jada.archive.1998.0022.
https://doi.org/10.14219/jada.archive.19...
). However, caries-infected dentin showed extremely low cohesive strength as a result of low mineral content and changes in organic matrix (99. Nakajima M, Sano H, Burrow MF, Tagami J, Yoshiyama M, Ebisu S et al. Tensile bond strength and SEM evaluation of caries-affected dentin using dentin adhesives. J Dent Res 1995; 74: 1679–1688, doi: 10.1177/00220345950740100901.
https://doi.org/10.1177/0022034595074010...
), and consequently lower microtensile bond strength compared to sound and caries-affected dentin (1010. Yoshiyama M, Doi J, Nishitani Y, Itota T, Tay FR, Carvalho RM et al. Bonding ability of adhesive resins to caries-affected and caries-infected dentin. J Appl Oral Sci 2004; 12: 171–176, doi: 10.1590/S1678-77572004000300002.
https://doi.org/10.1590/S1678-7757200400...
,1111. Costa AR, Garcia-Goday F, Carrer-Sobrinho L, Naves LZ, Raposo LH, Carvalho FG et al. Influence of different dentin supstrate (caries-affected, caries-infected, sound) on long-term μTBS. Braz Dent J 2017; 28: 16–23, doi: 10.1590/0103-6440201700879.
https://doi.org/10.1590/0103-64402017008...
). Although thicker hybrid layers are obtained in caries-infected dentin, many dentin tubules remain completely free from tag formation (1212. Hsu KW, Marshall SJ, Pinzon LM, Watanabe L, Saiz E, Marshall GW. SEM evaluation of resin-carious dentin interfaces formed by two dentin adhesive systems. Dent Mater 2008; 24: 880–887, doi: 10.1016/j.dental.2007.11.001.
https://doi.org/10.1016/j.dental.2007.11...
13. Yoshiyama M, Tay FR, Doi J, Nishitani Y, Yamada T, Itou K et al. Bonding of self-etch and total-etch adhesives to carious dentin. J Dent Res 2002; 81: 556–560, doi: 10.1177/154405910208100811.
https://doi.org/10.1177/1544059102081008...
1414. Yoshiyama M, Tay FR, Torii Y, Nishitani Y, Doi J, Itou K et al. Resin adhesion to carious dentin. Am J Dent 2003; 16: 47–52.). Due to this poor interaction during adhesive procedures, it is generally accepted that this layer needs to be removed prior to the placement of the restoration. Nevertheless, caries-affected dentin also produces lower bond strengths compared to normal dentin (1515. Wei S, Sadr A, Shimada Y, Tagami J. Effect of caries-affected dentin hardness on the shear bond strength of current adhesives. J Adhes Dent 2008; 10: 431–440. 16. Scholtanus JD, Purwanta K, Dogan N, Kleverlaan CJ, Feilzer AJ. Microtensile bond strength of three simplified adhesive systems to caries-affected dentin. J Adhes Dent 2010; 12: 273-278. 17. Taniguchi G, Nakajima M, Hosaka K, Iwamoto N, Ikeda M, Foxton RM et al. Improving the effect of NaOCl pretreatment on bonding to caries-affected dentin using self-etch adhesives. J Dent 2009; 37: 769–775, doi: 10.1016/j.jdent.2009.06.005.
https://doi.org/10.1016/j.jdent.2009.06....
1818. Kunawarote S, Nakajima M, Foxton RM, Tagami J. Effect of pretreatment with mildly acidic hypochlorous acid on adhesion to caries-affected dentin using a self-etch adhesive. Eur J Oral Sci 2011; 119: 86–92, doi: 10.1111/j.1600-0722.2010.00788.x.
https://doi.org/10.1111/j.1600-0722.2010...
) due to lower mechanical properties and changes in chemical and morphological properties, and therefore this layer, which is free of bacteria or contains clinically insignificant number of bacteria, may be retained (44. Holmgren CJ, Roux D, Domejean S. Minimal intervention dentistry: part 5. Atraumatic restorative treatment (ART)- a minimum intervention and minimally invasive approach for the management of dental caries. Br Dent J 2013; 214: 11–18, doi: 10.1038/sj.bdj.2012.1175.
https://doi.org/10.1038/sj.bdj.2012.1175...
).

Different methods are described for caries removal, including rotary burs, hand instrument action, air abrasion, ultrasonic techniques, enzymes treatment, chemomechanical techniques and laser treatment (1919. Yip HK, Samaranayake LP. Caries removal techniques and instrumentation: a review. Clin Oral Invest 1998; 2: 148–154, doi: 10.1007/s007840050062.
https://doi.org/10.1007/s007840050062...
). A laser commonly used for ablation of hard dental tissue is the Er:YAG laser. The erbium wavelengths coincide with the absorption peak of water and hydroxyapatite causing removal of hard dental tissue by microexplosions (2020. Gurgan S, Kiremitci A, Cakir FY, Yazici E, Gorucu J, Gutknecht N. Shear bond strength of composite bonded to erbium:yttrium-aluminum-garnet laser-prepared dentin. Lasers Med Sci 2009; 24: 117–122, doi: 10.1007/s10103-007-0532-0.
https://doi.org/10.1007/s10103-007-0532-...
). Carious tissue contains even more water compared to healthy hard dental tissues and therefore the high absorption of the Er:YAG laser provides a selective and conservative caries removal without extending the preparation into the sound tooth structure. Introduction of the Er:YAG laser with variable square pulse technology (VSPt) enabled the use of very short, square-shaped pulses of adjustable duration. The pulse profile is controlled and ensures that the power within the pulse is approximately constant with all pulse energy being used up for ablation (2121. Diaci J. Laser profilometry for the characterization of craters produced in hard dental tissues by Er:YAG and Er,Cr:YSGG Lasers. J Laser Health Acad 2008; 2: 1–9.). However, according to the histological evaluation in a study by Medioni et al. (2222. Medioni E, Rocca JP, Fornaini C, Merigo E. Histological evaluation of the three techniques for caries removal. J Oral Sci 2016; 58: 583–589, doi: 10.2334/josnusd.16-0225.
https://doi.org/10.2334/josnusd.16-0225...
), Er:YAG laser removed both infected and affected dentin. Another possibility to improve selective caries removal is the application of fluorescence feedback-controlled (FFC) Er:YAG laser, a combination of a diagnostic device and Er:YAG laser. With this system, the removal of dental hard tissues is controlled by the fluorescence signal from the tooth surface, induced by the red-infrared indium gallium arsenide diode laser (2323. Eberhard J, Eisenbeiss AK, Braun A, Herdderich J, Jepsen S. Evaluation of selective caries removal by a fluorescence feedback-controlled Er:YAG laser in vitro. Caries Res 2005; 39: 496–504, doi: 10.1159/000088186.
https://doi.org/10.1159/000088186...
). The excitation wavelength induces a fluorescence signal that has been assigned to protoporphyrin, a bacterial breakdown product (2424. König K, Flemming G, Hibst R. Laser-induced autofluorescence spectroscopy of dental caries. Cell Mol Biol 1998; 44: 1293–1300.). A sensor for the detection of fluorescence radiation of the dentinal tissue indicates whether any infected carious dentin is still present in the cavity, depending on the threshold level set when operating with FFC Er:YAG laser. The advantages of laser also include bactericidal properties from the high temperature (photothermal effect) during laser irradiation. The photothermal effect may be responsible for killing residual bacteria in cavities during caries ablation. However, the heat produced during laser ablation can cause thermal damage to irradiated substrates or the pulp in case of a temperature increase of more than 5.5°C, as shown in the in vivo study on monkeys by Zach and Cohen (2525. Zach L, Cohen G. Pulp response to externally applied heat. Oral Surg Oral Med Oral Pathol 1965; 19: 515–530, doi: 10.1016/0030-4220(65)90015-0.
https://doi.org/10.1016/0030-4220(65)900...
). Therefore, it is of outmost importance that these alternative techniques for caries removal are harmless for tooth pulp, in terms of thermal damage.

According to the literature available to the authors, there is no study comparing removal of cariogenic bacteria and carious dentin by measuring the temperature changes during caries ablation with different pulses of VSPt-based Er:YAG compared to FFC Er:YAG laser. Therefore, the primary objective of this in vitro study was to evaluate efficiency of removal of cariogenic bacteria and carious dentin by ablation with FFC Er:YAG laser and with different pulses of Er:YAG laser based on VSPt. The secondary objective was to measure the temperature during laser ablation of carious tissue.

Material and Methods

Study design

Seventy-two extracted human molar teeth were included in the study: 60 teeth with cavitated caries lesions extending into dentin, and 12 teeth without caries lesion. All molars were extracted for periodontal reasons at the Department of Oral Surgery, School of Dental Medicine, University of Zagreb. This experimental study was approved by the regional Ethical Review Board, University of Zagreb (106/09). Written informed consent was obtained from all participants to use their extracted teeth for scientific purposes. Inclusion criteria were teeth presenting cavitated caries lesions on the occlusal surface by visual examination and caries depth between the enamel-dentin junction and middle two-thirds of dentin examined on radiograph. Exclusion criteria were the presence of restorations or cavitations on other tooth surfaces. The tooth specimens were thoroughly cleaned of all residual debris using brushes and curettes and stored in saline for 2 weeks; saline was changed daily. All 60 teeth with carious lesions were randomly divided into four experimental groups (n=12) and one positive control group (n=12), while teeth without caries lesions were used as a negative control group (n=12). In the first experimental group, FFC Er:YAG laser (Key III, KaVo, Germany) was used. For the remaining three experimental groups, a second generation Fidelis Plus II Er:YAG laser (Fotona, Slovenia) with super short pulse (SSP, 50 µs), medium short pulse (MSP, 100 µs), and short pulse (SP, 300 µs), were used. For both lasers used all parameters were chosen according to the manufacturer’s instructions. During caries ablation, temperature changes were measured with an infrared thermal camera while real-time PCR analysis was used to determine the presence of cariogenic bacteria.

Ablation procedures

All specimens were fixed with clamps during the caries removal treatment.

Group 1 (FFC group). FFC Er:YAG laser was used with pulse energy of 350 mJ for the enamel cavity preparation and 250 mJ for the dentin treatment. The pulse duration was 400 µs with a repetition rate 10 Hz. The energy density for the enamel was 54.7 and 39.1 J·(cm2)-1·pulse for dentin-1. The contact handpiece (No. 2063, KaVo) with a spot size of 0.9 mm in diameter was used and the threshold level was set at 7 (1010. Yoshiyama M, Doi J, Nishitani Y, Itota T, Tay FR, Carvalho RM et al. Bonding ability of adhesive resins to caries-affected and caries-infected dentin. J Appl Oral Sci 2004; 12: 171–176, doi: 10.1590/S1678-77572004000300002.
https://doi.org/10.1590/S1678-7757200400...
). The laser stopped emitting the laser beam when the fluorescence radiation of the dentinal tissue was beyond the previously set threshold level of 7 and this was considered the endpoint of the caries ablation. During laser treatment, hard dental tissues were kept wet with continuous water irrigation at the rate of 3 mL/min.

Groups 2 (SSP group), 3 (MSP group) and 4 (SP group). Cavities were prepared with a second generation Fidelis Plus II Er:YAG laser (Fotona) with super short pulse (SSP, 50 µs), medium short pulse (MSP, 100 µs), and short pulse (SP, 300 µs; Figure 1). The Er:YAG laser energy was delivered by a non-contact RO2-C handpiece with a spot size of 0.9 mm in diameter, under continuous water spray (3 mL/min) at a focus distance of 7 mm from the target. The pulse energy was 350 mJ for enamel and 250 mJ for dentin, with a pulse frequency of 10 Hz. The energy density for enamel was 54.7 and 39.1 J·(cm2)-1·pulse for dentin-1. The caries removal was performed under visual control by testing the hardness of the remaining tissue with a dental probe. The caries ablation procedure was considered complete after the dental probe induced a sharp sound and did not penetrate the dentin.

Figure 1.
Average temperature (°C) and standard deviations for FFC, SP, MSP, and SSP groups. The temperatures were significantly higher in the SSP, MSP, and SP groups compared to temperatures in the FFC group (P<0.001). Temperature in the MSP group was significantly lower compared to SP (P<0.001), and SSP (P=0.002) groups. FFC: fluorescence feedback controlled; SP: short pulse; MSP: medium short pulse; SSP: super short pulse. Different letters indicate a statistically significant difference.

Infrared thermography

During caries ablation at room temperature, temperature changes were measured with an infrared thermal camera. In the FFC group, a Thermosensorik GmbH camera was used (Thermosensorik GmbH, Geramny), and in SSP, MSP, and SP groups the ThermaCAM p45 (Flir Systems Inc., USA) was used for temperature measurement. Thermovision cameras were fixed and placed directly above the specimens at a distance of 20 cm.

Real time PCR analysis

After caries ablation, samples were taken with a sterile cotton pellet from each experimental group and both positive and negative control groups. Cotton pellets were placed into Eppendorf tubes (Eppendorf, Germany), in 1 mL of phosphate buffer solution (PBS), and the contents of each tube were shaken to detach the samples of dentin from the cotton pellet. Real-time PCR analysis was used to investigate the presence of the gram-positive and gram-negative cariogenic bacteria in cavities after caries ablation (Table 1).

Table 1.
Gram-positive and gram-negative cariogenic bacteria investigated in this study.

For the bacterial DNA isolation, as the first step in bacterial identification, the QIAamp DNA Stool Mini Kit (Qiagen GmbH, Germany) was used according to the manufacturer’s instruction. Real-time PCR analysis was performed by using Primerdesign™ Ltd. (Great Britain) genesis standards kits for Lactobacillus acidophilus, Streptococcus sanguinis, Porphyromonas gingivalis, S. mutans, Actinomyces israelli, Prevotella melaninogenica, Fusobacterium nucleatum, Peptostreptococcus micros, P. endodontalis, and P. gingivalis. The reaction mixture contained 20 µL: 10 µL of Precision™ Mastermixa (Primerdesign™ Ltd.), 1 µL of mixture of a primer and a probe (Primerdesign™ Ltd.), 4 µL of water and 5 µL of diluted DNA according to standard procedures. The PCR cycling conditions were performed as described in the amplification protocol of the PrimerDesign kit and cycling was performed in a LC480 (Roche Diagnostics, Austria). During PCR amplification, forward and reverse primers were hybridized to each bacterial DNA. A fluorogenic probe was included in the same reaction mixture, which consisted of a DNA probe labelled with a 5′-dye and a 3′-quencher. During PCR amplification, the probe was cleaved and the reporter dye and quencher were separated. The resulting increase in fluorescence was detected on a range of real-time PCR platform (LC480 (Roche Diagnostics). Positive control inside the specific kit was performed simultaneously during each PCR reaction, and RNAse/DNAse free water was used as negative control. The resulting data were averaged between the duplicates and then the proportions of each species were calculated against the universal assay primer/probe set (UniB) values of all species within each sample.

Statistical analysis

Data was statistically analyzed with one-way ANOVA and Scheffe’s post hoc test with the level of significance set to 5%. The analysis was performed using Statistica 7.0 (StatSoft, USA).

Results

Cariogenic bacteria were found in all specimens of the positive control group (Table 2) and not in specimens of the negative control group. In all laser experimental groups, specimens were free of the bacterial contamination after ablation procedure.

Table 2.
Quantity of examined cariogenic bacteria DNA in negative control samples.

Average temperatures for each group and the range of average temperatures for every specimen in experimental groups during caries ablation are shown in Figure 1. The temperatures were significantly higher in the SSP (41.2±9.3°C), MSP (32.0±1.9°C), and SP (49.5±15.7°C) groups compared to the temperatures in the FFC group (4.5±2.4°C; P<0.001). The temperature during caries ablation in the MSP group was significantly lower compared to SP (P<0.001) and SSP (P=0.003) groups. There was no significant difference in temperatures between SP and SSP groups (P=0.129).

Discussion

The main purpose of this experimental study was to evaluate efficiency of removing cariogenic bacteria during ablation of carious tissue with two different lasers: FFC Er:YAG laser and VSPt based Er:YAG. In addition, the aim was also to measure the temperature changes during laser ablation of carious tissue. Qualitative and quantitative assessment of cariogenic bacteria of each sample was performed using RT PCR technique. Results showed that cavities in all experimental groups were free of bacterial contamination after laser-assisted caries ablation. Similar results were found only for FFC Er:YAG laser in studies that examined the amount of cariogenic bacteria after removal of carious tissue. These studies used different methods of evaluation of residual bacteria such as cultivation of dentin samples on culture medium for S. mutans and L. species (2626. Krause F, Braun A, Lotz G, Kneist S, Jepsen S, Eberhard J. Evaluation of selective caries removal in deciduous teeth by a fluorescence feedback-controlled Er:YAG laser in vivo. Clin Oral Invest 2008; 12: 209–215, doi: 10.1007/s00784-007-0169-1.
https://doi.org/10.1007/s00784-007-0169-...
) or histological staining for gram-positive and gram-negative bacteria (2727. Eberhard J, Eisenbeiss AK, Braun A, Hedderich J, Jepsen S. Evaluation of selective caries removal by a fluorescence feedback-controlled Er:YAG laser in vitro. Caries Res 2005; 39: 496–504, doi: 10.1159/000088186.
https://doi.org/10.1159/000088186...
). The mechanism of removing bacteria from the tooth cavity using laser technology is mechanical and photothermal. High temperatures cause changes in the cell wall and membrane of bacteria, along with denaturation of proteins and damage to nucleic acid, resulting in the death of bacteria (2828. Wilson M. Photolysis of oral bacteria and its potential use in the treatment of caries and periodontal disease. J Appl Bacteriol 1993; 75: 299–306, doi: 10.1111/j.1365-2672.1993.tb02780.x.
https://doi.org/10.1111/j.1365-2672.1993...
). Furthermore, the photothermal effect is also induced after absorption of the laser beam by water, which causes microexplosions and breakup of the bacteria (2929. Ando Y, Aoki A, Watanabe H, Ishikawa I. Bactericidal effect of Erbium YAG laser on periodontopathic bacteria. Laser Surg Med 1996; 19: 190–200, doi: 10.1002/(SICI)1096-9101(1996)19:2<190::AID-LSM11>3.0.CO;2-B.
https://doi.org/10.1002/(SICI)1096-9101(...
). Yamaguchi et al. (3030. Yamaguchi H, Kobayashi K, Osada R, Sakuraba E, Nomura T, Arai T, et al. Effects of irradiation of an erbium:YAG laser on root surfaces. J Periodontol 1997; 68: 1151–1155, doi: 10.1902/jop.1997.68.12.1151.
https://doi.org/10.1902/jop.1997.68.12.1...
) found that lipopolysaccharides in the cell membrane of gram-negative bacteria have a peak value of absorption of 2.92 µm, which is close to the wavelength of the Er:YAG laser. This specific laser removes 83.1% of lipopolysaccharides with a pulse energy of 100 mJ and frequency of 1 Hz. In this study, the pulse energy was 250 mJ, and the frequency 10 Hz, meaning that the bactericidal impact on the investigated gram-negative bacteria could be even more pronounced. It was also found that amines and amine groups that are present in bacteria also absorb the wavelength of the Er:YAG laser and this has a detrimental effect on bacteria due to the photochemical effect (3131. Socrates G (Editor). Infrared and Raman characteristics group frequencies: tables and charts. New York, Wiley; 2001.). Contrary to that, Valerio et al. (3232. Valerio RA, Borsatto MC, Serra MC, Polizeli SA, Nemezio MA, Galo R, et al. Caries removal in deciduous teeth using an Er:YAG laser: a randomized split-mouth clinical trial. Clin Oral Invest 2016; 20: 65–73, doi: 10.1007/s00784-015-1470-z.
https://doi.org/10.1007/s00784-015-1470-...
) in their clinical study showed that affected dentin in the pulpal wall had similar amounts of S. mutans and Lactobacillus sp. comparing caries removal by Er:YAG laser and bur. In their study, microbiological analysis was performed by counting tested bacteria (3232. Valerio RA, Borsatto MC, Serra MC, Polizeli SA, Nemezio MA, Galo R, et al. Caries removal in deciduous teeth using an Er:YAG laser: a randomized split-mouth clinical trial. Clin Oral Invest 2016; 20: 65–73, doi: 10.1007/s00784-015-1470-z.
https://doi.org/10.1007/s00784-015-1470-...
). However, inoculating cariogenic bacteria on culture medium in the laboratory might yield false positive results, because other bacteria, besides the tested ones, can grow on the same culture medium (3333. Cappelli DP, Mobley CC. Prevention in clinical oral health care. St. Louise, Mosby Elsevier; 2008.). The RT-PCR method, which was used in this study, is a more accurate method to detect clinically relevant cariogenic bacteria because it has a higher sensitivity and specificity in the detection of bacterial nucleic acids (3434. Suzuki N, Yoshida A, Nakano Y. Quantitative analysis of multi-species oral biofilms by TaqMan real-time PCR. Clin Med Res 2005; 3: 176–185, doi: 10.3121/cmr.3.3.176.
https://doi.org/10.3121/cmr.3.3.176...
).

Temperature measurements showed the lowest values for the FFC Er:YAG group, probably due to a feedback control of the laser, which appeared to operate like a cut-off switch when infected dentin was eliminated (3535. Schwass DR, Leichter JW, Purton DG, Swain MV. Evaluating the efficiency of caries removal using an Er:YAG laser driven by fluorescence feedback control. Arch Oral Biol 2013; 58: 603–610, doi: 10.1016/j.archoralbio.2012.09.017.
https://doi.org/10.1016/j.archoralbio.20...
) and stopped the laser from emitting energy intermittently. In this investigation, the threshold level was set at 7 according to the results of Krause et al. (2626. Krause F, Braun A, Lotz G, Kneist S, Jepsen S, Eberhard J. Evaluation of selective caries removal in deciduous teeth by a fluorescence feedback-controlled Er:YAG laser in vivo. Clin Oral Invest 2008; 12: 209–215, doi: 10.1007/s00784-007-0169-1.
https://doi.org/10.1007/s00784-007-0169-...
). They indicated that a fluorescence threshold level of 7 or 8 units can guide an Er:YAG laser to a complete removal of carious dentin (2626. Krause F, Braun A, Lotz G, Kneist S, Jepsen S, Eberhard J. Evaluation of selective caries removal in deciduous teeth by a fluorescence feedback-controlled Er:YAG laser in vivo. Clin Oral Invest 2008; 12: 209–215, doi: 10.1007/s00784-007-0169-1.
https://doi.org/10.1007/s00784-007-0169-...
). Interestingly, for Er:YAG based on VSPt the lowest value of average temperature was measured for the MSP group, while there was no significant difference between the SSP and SP groups. Diaci et al. (2121. Diaci J. Laser profilometry for the characterization of craters produced in hard dental tissues by Er:YAG and Er,Cr:YSGG Lasers. J Laser Health Acad 2008; 2: 1–9.) showed that shorter pulses with high energy enable a higher ablation rate of tissue than the diffusion of heat into the surrounding tissue. That causes less temperature rise compared to longer pulses like the SP used in this study. However, shorter pulses, like SSP, also decrease the time for cooling of hard dental tissue, which may explain the results of this study and the higher temperatures found for the shortest pulse. It should be emphasized that the infrared thermal camera measures the temperature in the center of the laser irradiation where the laser energy is maximal and produces large amount of heat, hence the temperature rise. These temperatures would be found in adjacent layers of dentin or in the pulp chamber.

Within the limitations of this study it was concluded that the Er:YAG lasers used in this study with different modes were efficient in removing cariogenic bacterial from infected dentin in vitro. In all treatment groups, cariogenic bacteria were completely removed. However, the lowest temperature rise was associated with the use of the FFC Er:YAG laser.

Based on this in vitro study, laser treatment for removal of carious dentin and cariogenic bacteria seems to be an efficient treatment modality without causing excessive temperatures, which might adversely affect pulp vitality.

Aknowledgements

The authors wish to thank Fotona and Kavo for providing the laser equipment and Janez Žabkar for his support during temperature measurements. The authors wish to thank Professor Marijana Javornik Cubric for proof reading.

References

  • 1
    Stoll R, Urban-Klein B, Giacomin P, Loukas A, Jablonski-Momeni A. In vivo assessment of caries excavation with a fluorescence camera compared to direct bacteriological sampling and quantitative analysis using flow cytometry. Laser Med Sci 2015; 30: 843–849, doi: 10.1007/s10103-013-1459-2.
    » https://doi.org/10.1007/s10103-013-1459-2
  • 2
    Banerjee A. Minimal intervention dentistry: part 7. Minimally invasive operative caries management: rationale and techniques. Br J Dent 2013; 214: 107–111, doi: 10.1038/sj.bdj.2013.106.
    » https://doi.org/10.1038/sj.bdj.2013.106
  • 3
    Almeida Neves A, Coutinho E, Cardoso MV, Lambrechts P, Van Meerbeek B. Current concepts and techniques for caries excavation and adhesion to residual dentin. J Adhes Dent 2011; 13: 7–22, doi: 10.3290/j.jad.a18443.
    » https://doi.org/10.3290/j.jad.a18443
  • 4
    Holmgren CJ, Roux D, Domejean S. Minimal intervention dentistry: part 5. Atraumatic restorative treatment (ART)- a minimum intervention and minimally invasive approach for the management of dental caries. Br Dent J 2013; 214: 11–18, doi: 10.1038/sj.bdj.2012.1175.
    » https://doi.org/10.1038/sj.bdj.2012.1175
  • 5
    Macedo GV, Yamauchi M, Bedran-Russo AK. Effects of chemical cross- linkers on caries-affected dentin bonding. J Dent Res 2009; 88: 1096–1100, doi: 10.1177/0022034509351001.
    » https://doi.org/10.1177/0022034509351001
  • 6
    Banerjee A, Kellow S, Mannocci F, Cook RJ, Watson TF. An in vitro evaluation of microtensile bond strengths of two adhesive bonding agents to residual dentine after caries removal using three excavation techniques. J Dent 2010; 38: 480–489, doi: 10.1016/j.jdent.2010.03.002.
    » https://doi.org/10.1016/j.jdent.2010.03.002
  • 7
    Hahn CL, Best AM, Tew JG. Cytokine induction by Streptococcus mutans and pulpal pathogenesis. Infect Immun 2000; 68: 6785–6789, doi: 10.1128/IAI.68.12.6785-6789.2000.
    » https://doi.org/10.1128/IAI.68.12.6785-6789.2000
  • 8
    Mertz-Fairhurst EJ, Curtis JW, Ergle JW, Ruggeberg FA, Adair SM. Ultraconservative and cariostatic sealed restorations: results at year 10. J Am Dent Assoc 1998; 129: 55–66, doi: 10.14219/jada.archive.1998.0022.
    » https://doi.org/10.14219/jada.archive.1998.0022
  • 9
    Nakajima M, Sano H, Burrow MF, Tagami J, Yoshiyama M, Ebisu S et al. Tensile bond strength and SEM evaluation of caries-affected dentin using dentin adhesives. J Dent Res 1995; 74: 1679–1688, doi: 10.1177/00220345950740100901.
    » https://doi.org/10.1177/00220345950740100901
  • 10
    Yoshiyama M, Doi J, Nishitani Y, Itota T, Tay FR, Carvalho RM et al. Bonding ability of adhesive resins to caries-affected and caries-infected dentin. J Appl Oral Sci 2004; 12: 171–176, doi: 10.1590/S1678-77572004000300002.
    » https://doi.org/10.1590/S1678-77572004000300002
  • 11
    Costa AR, Garcia-Goday F, Carrer-Sobrinho L, Naves LZ, Raposo LH, Carvalho FG et al. Influence of different dentin supstrate (caries-affected, caries-infected, sound) on long-term μTBS. Braz Dent J 2017; 28: 16–23, doi: 10.1590/0103-6440201700879.
    » https://doi.org/10.1590/0103-6440201700879
  • 12
    Hsu KW, Marshall SJ, Pinzon LM, Watanabe L, Saiz E, Marshall GW. SEM evaluation of resin-carious dentin interfaces formed by two dentin adhesive systems. Dent Mater 2008; 24: 880–887, doi: 10.1016/j.dental.2007.11.001.
    » https://doi.org/10.1016/j.dental.2007.11.001
  • 13
    Yoshiyama M, Tay FR, Doi J, Nishitani Y, Yamada T, Itou K et al. Bonding of self-etch and total-etch adhesives to carious dentin. J Dent Res 2002; 81: 556–560, doi: 10.1177/154405910208100811.
    » https://doi.org/10.1177/154405910208100811
  • 14
    Yoshiyama M, Tay FR, Torii Y, Nishitani Y, Doi J, Itou K et al. Resin adhesion to carious dentin. Am J Dent 2003; 16: 47–52.
  • 15
    Wei S, Sadr A, Shimada Y, Tagami J. Effect of caries-affected dentin hardness on the shear bond strength of current adhesives. J Adhes Dent 2008; 10: 431–440.
  • 16
    Scholtanus JD, Purwanta K, Dogan N, Kleverlaan CJ, Feilzer AJ. Microtensile bond strength of three simplified adhesive systems to caries-affected dentin. J Adhes Dent 2010; 12: 273-278.
  • 17
    Taniguchi G, Nakajima M, Hosaka K, Iwamoto N, Ikeda M, Foxton RM et al. Improving the effect of NaOCl pretreatment on bonding to caries-affected dentin using self-etch adhesives. J Dent 2009; 37: 769–775, doi: 10.1016/j.jdent.2009.06.005.
    » https://doi.org/10.1016/j.jdent.2009.06.005
  • 18
    Kunawarote S, Nakajima M, Foxton RM, Tagami J. Effect of pretreatment with mildly acidic hypochlorous acid on adhesion to caries-affected dentin using a self-etch adhesive. Eur J Oral Sci 2011; 119: 86–92, doi: 10.1111/j.1600-0722.2010.00788.x.
    » https://doi.org/10.1111/j.1600-0722.2010.00788.x
  • 19
    Yip HK, Samaranayake LP. Caries removal techniques and instrumentation: a review. Clin Oral Invest 1998; 2: 148–154, doi: 10.1007/s007840050062.
    » https://doi.org/10.1007/s007840050062
  • 20
    Gurgan S, Kiremitci A, Cakir FY, Yazici E, Gorucu J, Gutknecht N. Shear bond strength of composite bonded to erbium:yttrium-aluminum-garnet laser-prepared dentin. Lasers Med Sci 2009; 24: 117–122, doi: 10.1007/s10103-007-0532-0.
    » https://doi.org/10.1007/s10103-007-0532-0
  • 21
    Diaci J. Laser profilometry for the characterization of craters produced in hard dental tissues by Er:YAG and Er,Cr:YSGG Lasers. J Laser Health Acad 2008; 2: 1–9.
  • 22
    Medioni E, Rocca JP, Fornaini C, Merigo E. Histological evaluation of the three techniques for caries removal. J Oral Sci 2016; 58: 583–589, doi: 10.2334/josnusd.16-0225.
    » https://doi.org/10.2334/josnusd.16-0225
  • 23
    Eberhard J, Eisenbeiss AK, Braun A, Herdderich J, Jepsen S. Evaluation of selective caries removal by a fluorescence feedback-controlled Er:YAG laser in vitro Caries Res 2005; 39: 496–504, doi: 10.1159/000088186.
    » https://doi.org/10.1159/000088186
  • 24
    König K, Flemming G, Hibst R. Laser-induced autofluorescence spectroscopy of dental caries. Cell Mol Biol 1998; 44: 1293–1300.
  • 25
    Zach L, Cohen G. Pulp response to externally applied heat. Oral Surg Oral Med Oral Pathol 1965; 19: 515–530, doi: 10.1016/0030-4220(65)90015-0.
    » https://doi.org/10.1016/0030-4220(65)90015-0
  • 26
    Krause F, Braun A, Lotz G, Kneist S, Jepsen S, Eberhard J. Evaluation of selective caries removal in deciduous teeth by a fluorescence feedback-controlled Er:YAG laser in vivo Clin Oral Invest 2008; 12: 209–215, doi: 10.1007/s00784-007-0169-1.
    » https://doi.org/10.1007/s00784-007-0169-1
  • 27
    Eberhard J, Eisenbeiss AK, Braun A, Hedderich J, Jepsen S. Evaluation of selective caries removal by a fluorescence feedback-controlled Er:YAG laser in vitro Caries Res 2005; 39: 496–504, doi: 10.1159/000088186.
    » https://doi.org/10.1159/000088186
  • 28
    Wilson M. Photolysis of oral bacteria and its potential use in the treatment of caries and periodontal disease. J Appl Bacteriol 1993; 75: 299–306, doi: 10.1111/j.1365-2672.1993.tb02780.x.
    » https://doi.org/10.1111/j.1365-2672.1993.tb02780.x
  • 29
    Ando Y, Aoki A, Watanabe H, Ishikawa I. Bactericidal effect of Erbium YAG laser on periodontopathic bacteria. Laser Surg Med 1996; 19: 190–200, doi: 10.1002/(SICI)1096-9101(1996)19:2<190::AID-LSM11>3.0.CO;2-B.
    » https://doi.org/10.1002/(SICI)1096-9101(1996)19:2<190::AID-LSM11>3.0.CO;2-B
  • 30
    Yamaguchi H, Kobayashi K, Osada R, Sakuraba E, Nomura T, Arai T, et al. Effects of irradiation of an erbium:YAG laser on root surfaces. J Periodontol 1997; 68: 1151–1155, doi: 10.1902/jop.1997.68.12.1151.
    » https://doi.org/10.1902/jop.1997.68.12.1151
  • 31
    Socrates G (Editor). Infrared and Raman characteristics group frequencies: tables and charts. New York, Wiley; 2001.
  • 32
    Valerio RA, Borsatto MC, Serra MC, Polizeli SA, Nemezio MA, Galo R, et al. Caries removal in deciduous teeth using an Er:YAG laser: a randomized split-mouth clinical trial. Clin Oral Invest 2016; 20: 65–73, doi: 10.1007/s00784-015-1470-z.
    » https://doi.org/10.1007/s00784-015-1470-z
  • 33
    Cappelli DP, Mobley CC. Prevention in clinical oral health care. St. Louise, Mosby Elsevier; 2008.
  • 34
    Suzuki N, Yoshida A, Nakano Y. Quantitative analysis of multi-species oral biofilms by TaqMan real-time PCR. Clin Med Res 2005; 3: 176–185, doi: 10.3121/cmr.3.3.176.
    » https://doi.org/10.3121/cmr.3.3.176
  • 35
    Schwass DR, Leichter JW, Purton DG, Swain MV. Evaluating the efficiency of caries removal using an Er:YAG laser driven by fluorescence feedback control. Arch Oral Biol 2013; 58: 603–610, doi: 10.1016/j.archoralbio.2012.09.017.
    » https://doi.org/10.1016/j.archoralbio.2012.09.017

Publication Dates

  • Publication in this collection
    2018

History

  • Received
    10 July 2017
  • Accepted
    7 Nov 2017
Associação Brasileira de Divulgação Científica Av. Bandeirantes, 3900, 14049-900 Ribeirão Preto SP Brazil, Tel. / Fax: +55 16 3315-9120 - Ribeirão Preto - SP - Brazil
E-mail: bjournal@terra.com.br