Comparison of the Normal Visual Fields Between the Goldmann and Humphrey Kinetic Perimetries.
Song Ee Chung, Sung Jin Lee, Kyung Seek Choi, Song Hee Park
1Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
2Department of Ophthalmology, Soonchunhyang University School of Medicine, Seoul, Korea. scheye@hosp.sch.ac.kr
골드만과 험프리 동적시야검사에 따른 정상시야의 비교
정송이1ㆍ이성진2ㆍ최경식2ㆍ박성희2
Department of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine1, Seoul, Korea / Department of Ophthalmology, Soonchunhyang University School of Medicine2, Seoul, Korea
Abstract
PURPOSE
To show Humphrey automated kinetic perimetry can be substituted for Goldmann perimetry, which has been used in the field of disability evaluation field, the differences of normal visual fields between two perimetries were evaluated. METHODS: Goldmann and Humphrey automated kinetic perimetries were performed simultaneously in 70 eyes of 35 normal healthy Koreans who had no specific ophthalmologic disease at 12 meridians; 0degrees, 30degrees, 60degrees, 90degrees, 120degrees, 150degrees, 180degrees, 210degrees, 240degrees, 270degrees, 300degrees, and 330degrees. The mean values of field in each case were compared. In addition, the corrected values were obtained through the calculation of the difference in the two maximal fields. RESULTS: The visual fields of Humphrey and Goldmann kinetic perimetries showed a similar oval shape, but the fields of Goldmann were statistically significantly wider than the Humphrey fields. As the values of Humphrey were compared with the original data of Goldmann, all values of the visual field were narrow. CONCLUSIONS: The visual fields by Humphrey automated kinetic perimetry were smaller than those by Goldmann perimetry. Therefore, if Humphrey kinetic perimetry is used for the evaluation of visual disability, the visual field should be evaluated after the correction.
Key Words: Goldmann perimetry;Humphrey automated perimetry;Kinetic visual field


ABOUT
BROWSE ARTICLES
EDITORIAL POLICY
FOR CONTRIBUTORS
Editorial Office
SKY 1004 Building #701
50-1 Jungnim-ro, Jung-gu, Seoul 04508, Korea
Tel: +82-2-583-6520    Fax: +82-2-583-6521    E-mail: kos08@ophthalmology.org                

Copyright © 2024 by Korean Ophthalmological Society.

Developed in M2PI

Close layer
prev next