Skip to main content

ORIGINAL RESEARCH article

Front. Med., 23 November 2020
Sec. Rheumatology
Volume 7 - 2020 | https://doi.org/10.3389/fmed.2020.581248

Salivary Gland Ultrasonography in Sjögren's Syndrome: A European Multicenter Reliability Exercise for the HarmonicSS Project

Alen Zabotti1 Sara Zandonella Callegher1 Annarita Tullio2 Arso Vukicevic3,4 Alojzija Hocevar5 Vera Milic6 Giacomo Cafaro7 Marina Carotti8 Konstantina Delli9 Orazio De Lucia10 Diana Ernst11 Francesco Ferro12 Angelica Gattamelata13 Giuseppe Germanò14 Ivan Giovannini1 Daniel Hammenfors15,16 Malin V. Jonsson15,17 Sandrine Jousse-Joulin18,19 Pierluigi Macchioni14 Simone Parisi20 Carlo Perricone7 Martin Helmut Stradner21 Nenad Filipovic3,4 Athanasios G. Tzioufas22 Francesca Valent2 Salvatore De Vita1*
  • 1Rheumatology Clinic, Department of Medical Area, Academic Hospital S. Maria della Misericordia, University of Udine, Udine, Italy
  • 2Institute of Epidemiology, Academic Hospital 'Santa Maria della Misericordia', Udine, Italy
  • 3Faculty of Engineering Science, University of Kragujevac, Kragujevac, Serbia
  • 4Bioengineering Research and Development Center (BioIRC), Kragujevac, Serbia
  • 5Department of Rheumatology, University Medical Centre Ljubljana, Ljubljana, Slovenia
  • 6Institute of Rheumatology, Belgrade, Serbia
  • 7Rheumatology Unit, Department of Medicine, University of Perugia, Perugia, Italy
  • 8Department of Radiology, Ospedali Riuniti, Università Politecnica delle Marche, Ancona, Italy
  • 9Department of Oral and Maxillofacial Surgery, University of Groningen, University Medical Center Groningen, Groningen, Netherlands
  • 10Unit of Clinical Rheumatology, Department of Rheumatology and Medical Sciences, Aziende Socio Sanitarie Territoriali (ASST) Centro Traumatologico Ortopedico G. Pini-Centri Traumatologici Ortopedici (CTO), Milan, Italy
  • 11Clinic for Immunology and Rheumatology, Hannover Medical School, Hannover, Germany
  • 12Rheumatology Unit, Department of Clinical and Experimental Medicine, University of Pisa, Pisa, Italy
  • 13Department of Internal Medicine and Medical Specialties, Rheumatology, Sapienza University of Rome, Rome, Italy
  • 14Rheumatology Unit, Department of Internal Medicine, Azienda Ospedaliera Arcispedale Santa Maria Nuova (ASMN), Istituto di Ricovero e Cura a Carattere Scientifico, Reggio Emilia, Italy
  • 15Broegelmann Research Laboratory, Department of Clinical Science, University of Bergen, Bergen, Norway
  • 16Department of Rheumatology, Haukeland University Hospital, Bergen, Norway
  • 17Section for Oral and Maxillofacial Radiology, Department of Clinical Dentistry, University of Bergen, Bergen, Norway
  • 18Rheumatology Department, Centre Hospitalier Universitaire (CHU) de Brest, Univ Brest, Brest, France
  • 19UMR 1227, Lymphocytes B et Autoimmunité (LBAI), Inserm, Univ Brest, Brest, France
  • 20Unit of Rheumatology, Department of General and Specialty Medicine, Città della Salute e della Scienza, Turin, Italy
  • 21Department of Rheumatology and Immunology, Medical University of Graz, Graz, Austria
  • 22Department of Pathophysiology, School of Medicine, National and Kapodistrian University of Athens, Athens, Greece

Objectives: Salivary gland ultrasonography (SGUS) is increasingly applied for the management of primary Sjögren's syndrome (pSS). This study aims to: (i) compare the reliability between two SGUS scores; (ii) test the reliability among sonographers with different levels of experience.

Methods: In the reliability exercise, two four-grade semi-quantitative SGUS scoring systems, namely De Vita et al. and OMERACT, were tested. The sonographers involved in work-package 7 of the HarmonicSS project from nine countries in Europe were invited to participate. Different levels of sonographers were identified on the basis of their SGUS experience and of the knowledge of the tested scores. A dedicated atlas was used as support for SGUS scoring.

Results: Twenty sonographers participated in the two rounds of the reliability exercise. The intra-rater reliability for both scores was almost perfect, with a Light's kappa of 0.86 for the De Vita et al. score and 0.87 for the OMERACT score. The inter-rater reliability for the De Vita et al. and the OMERACT score was substantial with Light's Kappa of 0.75 and 0.77, respectively. Furthermore, no significant difference was noticed among sonographers with different levels of experience.

Conclusion: The two tested SGUS scores are reliable for the evaluation of major salivary glands in pSS, and even less-expert sonographers could be reliable if adequately instructed.

Introduction

Primary Sjögren's syndrome (pSS) is a systemic autoimmune and lymphoproliferative disease, mainly involving the salivary glands (SGs) (1). In pSS, the SGs inflammatory process ultimately results in glandular structural damage (2, 3). Active glandular lesions are characterized by inflammation and lymphoproliferation, with varying degrees of glandular damage by fibrosis, fatty accumulation, and loss of acinar and ductal parenchyma (46). These pathological abnormalities, for whose characterization SG biopsy is the gold standard technique, lead to the typical glandular inhomogeneity detected by salivary gland ultrasonography (SGUS), with hypo/anechoic areas and hyperechoic bands (710). So far, parenchymal inhomogeneity proved to be the main sonographic feature to build SGUS scores in pSS (7, 8, 11). In 1992, De Vita et al. firstly developed a comprehensive sonographic score of major SGs in pSS defining, by means of a discriminant analysis, inhomogeneity as the main SGUS abnormality associated with pSS; the developed semi-quantitative score ranged from 0 to 3 in each gland, from normal-appearing morphology to severe inhomogeneity (7). Several scoring systems have been proposed subsequently, and most of them used glandular inhomogeneity as the key SGUS abnormality. In addition, several clinicians now routinely use SGUS to assess patients with suspected or established pSS (9, 10, 12). However, even if many authors strongly believe that SGUS is relevant for the management of pSS, definite recommendations are still lacking, and this technique is not yet part of the classification criteria for pSS. This is mainly due to: (i) the absence of consensus on elementary SGUS lesions and scoring when pSS classification criteria were set up (12); (ii) the evidence of significant intra- and inter-rater disagreement (1214); (iii) the use of old pSS cohorts for validation of pSS classification criteria, when SGUS was not yet fully developed (15). In order to overcome these issues, the Outcome Measure in Rheumatology (OMERACT) working group on the use of ultrasonography in pSS recently generated, after a three-round Delphi process, the definitions for the SGUS elementary lesions in pSS, and the scanning procedure (16). Lastly, the same OMERACT group developed a four-grade SGUS score, which showed excellent intra-rater reliability and a good inter-rater reliability between experts (16). By the possible addition of SGUS as a new criterion, the 2016 ACR-EULAR criteria for the classification of pSS may be ameliorated in sensitivity without modifying the specificity (17).

On the other hand, very few data exist to support the reliability of SGUS in pSS, and all the published studies involved only experts and well-trained sonographers. Therefore, it definitely remains to be investigated how reliability varies along with the observer training level and experience, and this still represents the major obstacle for a wider acceptance of SGUS in pSS evaluation (13).

Furthermore, the images from previous studies were not publicly available, making rather difficult for subsequent studies to reproduce and/or to objectively compare their findings. Accordingly, the leading pSS experts (35 partners from 13 countries) have recently started the HarmonicSS (http://harmonicss.eu) initiative to envelop independently reported cohorts and metacentric data, including SGUS in a dedicated Workpackage (WP), namely WP7. This study was created within the HarmonicSS initiative, and it is preliminary to further studies on the application of artificial intelligence in SGUS. At the current stage of the initiative, this study aims to: (i) evaluate the reliability among sonographers with different levels of expertise in SGUS; (ii) compare the reliability performance between two different semi-quantitative SGUS scores, widely used and easy to perform, being the “extremes” in the year of publication (i.e., the scores by De Vita et al., 1992, and by OMERACT, 2019); (iii) provide a data set that will be publicly available, to serve as a standardized benchmark for further studies.

Materials and Methods

The Guidelines for Reporting Reliability and Agreement Studies (GRAAS) were followed for the preparation of the manuscript (18).

Salivary Gland Ultrasound Scores

A simple, semi-quantitative 0–3 SGUS scoring system was recently selected by a systematic review and meta-analysis as more appropriate for diagnostic purposes in terms of specificity and heterogeneity in pSS, with respect to the other scoring systems available (e.g., 0–16 and 0–48) (19). One of the aims of the work-package 7 (WP7) of the HarmonicSS project is to develop and improve the role of SGUS for pSS management. Participants and coordinators of WP7 agreed to use two four-grade semi-quantitative scoring systems, namely De Vita et al. score (7) and OMERACT score (16), for the assessment of major SGs morphology in pSS patients enrolled in the HarmonicSS project.

The score by De Vita et al. is the long-standing available in the literature in pSS, is easy-to-perform, and includes both hypo/anechoic areas and hyperechoic bands as the main sonographic features to define parenchymal SG inhomogeneity, while in the OMERACT score parenchymal inhomogeneity is supported only by the presence of hypo/anechoic areas. The De Vita et al. score comprises: grade 0, normal-appearing parenchyma; grade 1, mild inhomogeneity with isolated and small hypo/anechoic areas, without hyperechoic bands; grade 2, evident inhomogeneity with multiple scattered hypo/anechoic areas and/or few hyperechoic bands; grade 3, severe/gross inhomogeneity due to large and confluent hypo/anechoic areas and/or diffuse hyperechoic bands (Figure 1). In this exercise, as well as in the recent studies where the De Vita et al. score was applied (2022), the grade 1 was better specified, since the term of “mild inhomogeneity” was initially included, as a diffuse or localized micro-areolar structure. The OMERACT score is the most recent one, proposed in 2019 according to guidelines for selecting outcome measure instruments (OMI) (23) and it is defined as follows: grade 0, normal-appearing SG parenchyma; grade 1, minimal change: mild inhomogeneity without hypo/anechoic areas; grade 2, moderate change: moderate inhomogeneity with focal hypo/anechoic areas; grade 3, severe change: diffuse inhomogeneity with hypo/anechoic areas occupying the entire gland surface (Figure 1).

FIGURE 1
www.frontiersin.org

Figure 1. Ultrasound images of parotid glands in the two four-grade semi-quantitative scoring system: (A) De Vita et al. score grade 0; (B) De Vita et al. score grade 1; (C) De Vita et al. score grade 2; (D) De Vita et al. score grade 3; (E) OMERACT score grade 0; (F) OMERACT score grade 1; (G) OMERACT score grade 2; (H) OMERACT score grade 3.

Participants

Twenty-seven sonographers involved in the WP7 of the HarmonicSS project (https://www.harmonicss.eu/the-project/project-structure/) from nine countries in Europe (Austria, France, Germany, Italy, Norway, Serbia, Slovenia, The Netherlands, and United Kingdom) were invited to participate. The years of experience in SGUS, the number of pSS patients evaluated per year, and scores usually used in clinical practice were collected for each participant. Sonographers with at least 6 years of experience in SGUS were identified as experts, while the user definition was applied in those who already applied the De Vita et al. and/or OMERACT scores in clinical practice or for research purposes. Four different levels of sonographers were then identified as follows: user and experts (U-E group), non-users and experts (NU-E group), users and non-experts (U-NE), non-users, and non-experts (NU-NE group). A dedicated SGUS atlas was sent to all participants, with general SGUS issues, and with definitions and examples for each grade of glandular inhomogeneity for both scores.

Reliability Exercise and HarmonicSS Data Set

A pool of 225 sonographic static images (83 normal-appearing images, 42 images with mild inhomogeneity, 47 images with moderate inhomogeneity, and 53 images with severe inhomogeneity) of major SGs [114 parotid glands (PGs) and 111 sub-mandibular glands (SMGs)], from 150 patients with suspected pSS or definite pSS, was independently scored in two rounds. The sonographic images were previously collected and de-identified from the database of four rheumatologists involved in the exercise (AZ, AH, VM, ODL) and were different from those presented in the atlas. Four different ultrasound machines were used to store images, i.e., Samsung RS85, Philips Epiq, GE Logiq E9, and ESAOTE MyLab70. For both scoring rounds, each observer was provided with an anonymized and uniquely randomized data set in order to ensure that scorings performed in this study could be not influenced with others' scorings. The reliability exercise was carried out remotely by using the HarmonicSS web-based platform (https://private.harmonicss.eu). For each round, the participants had to apply the De Vita et al. score and the OMERACT score for each of the 225 images. The described data set, together with accompanying script files and instructions for their usage, are publicly available on the GitHub repository (https://github.com/ArsoVukicevic/Assessment-of-pSS-fromSGUSimages/tree/master/3%20HarmonicSS%20benchmark%20dataset) that will be further managed by the HarmonicSS group and authors of this study.

Statistical Analysis

Inter-rater reliability was assessed by using kappa statistics and computing the linear and squared weighted and unweighted kappa coefficient (Fleiss-Cohen weights) for each pair of raters for both scores considered. In the analyses the weighted kappa (i.e., linear and squared kappa), in addition to unweighted kappa, was performed since the use of weighting schemes allows to take into account the closeness of agreement between categories. The weights are presented in Supplementary Table 1. The mean, median, 1st and 3rd quartile, minimum (min), and maximum (max) kappa values were calculated. Then Light's kappa was considered as the mean kappa value. To assess intra-rater reliability, we computed the linear and squared weighted and unweighted kappa coefficients between two readings by each rater for both scores. We then computed Light's kappa (mean of intra-rater kappa values), median, 1st and 3rd quartile, minimum (min), and maximum (max) kappa values. The bootstrap percentile method was used to compute the 95% CI of every Light's, Fleiss and Cohen kappa. Furthermore, we converted every 0–3 score database in 0–1 score database considering scores 0 and 1 as normal-appearing scores and converted to 0; whereas scores 2 and 3 were held as pathological scores and were converted to score 1. Every analysis was repeated in the 0–1 score database. We stratified squared weighted kappa coefficients by levels of SGUS experience and the knowledge of the tested scoring systems. We obtained kappa for four levels combining experience and use information: U-E, U-NE, NU-E, and NU-NE. The results were then compared to evaluate the overlap between 95% confidence intervals. Kappa coefficients were interpreted according to Landis and Koch (24). Kappa values of 0–0.20 were considered slight, 0.21–0.40 fair, 0.41–0.60 moderate, 0.61–0.80 substantial, and 0.81–1.00 almost perfect. All statistical analyses were carried out using R version 3.6.2 (R Foundation for Statistical Computing, Vienna, Austria). For clarity, only weighted kappa are displayed in the text and tables; however, full statistical results are available in the Supplementary Material results and in the repository.

Results

Participants

Twenty out of 27 invited sonographers from eight countries in Europe (Austria, France, Germany, Italy, Norway, Serbia, Slovenia, and The Netherlands) participated in the two rounds of the reliability exercise. Seventeen out of 20 were rheumatologists, two were radiologists, and one was a specialist in oral medicine. Their experience with SGUS was 8.75 (± 5.97) years, with a mean number of pSS patients evaluated by SGUS per year of 127.6 (± 108.43). Thirteen out of 20 (65%) sonographers were experts, and 14/20 (70%) were users. The mean SGUS use was 11.8 (± 5.0) years for experts and 3.0 (± 1.5) years for non-experts (p < 0.001). Nine out of twenty (45%) sonographers were U-E, 5/20 (25%) were U-NE, 4/20 (20%) were NU-E, and 2/20 (10%) were NU-NE.

Participants Scores

The mean De Vita et al. score and OMERACT score of the first round is reported in Supplementary Figure 1. The mean De Vita et al. score was 1.14 (± 1.10) for U-E, 1.33 (± 1.12) for U-NE, 1.31 (± 1.10) for NU-E, and 1.45 (± 1.08) for NU-NE. The mean OMERACT score was 1.28 (± 1.16) for U-E, 1.41 (± 1.07) for U-NE, 1.41 (± 1.13) for NU-E, and 1.80 (± 1.08) for NU-NE. The mean OMERACT score in NU-NE was significantly higher compared with U-E group (p < 0.05). No other significant differences among groups were present.

Reliability Exercise

Intra-Rater Reliability

The intra-rater reliability for the De Vita et al. and the OMERACT score was almost perfect with a Light's Kappa of 0.86 (0.79–0.95; 95% CI 0.84–0.89) and 0.87 (range 0.81–0.95; 95% CI 0.85–0.90), respectively (Table 1). High levels of reliability were also reached when comparing normal-appearing scores vs. pathological scores, achieving a Light's Kappa of 0.80 for the De Vita et al. (0.67–0.95; 95% CI 0.76–0.84) and 0.81 for the OMERACT score (0.59–0.95; 95% CI 0.76–0.85) (Table 1). Unweighted kappa and weighted linear kappa are presented in Supplementary Table 2. No significant differences were found between the intra-rater reliability of PGs and SMGs (Supplementary Table 3).

TABLE 1
www.frontiersin.org

Table 1. Intra-rater reliability.

Inter-Rater Reliability

The inter-rater reliability for the De Vita et al. and the OMERACT score was substantial with Light's Kappa of 0.76 (0.50–0.92; 95% CI 0.72–0.79) and 0.77 (0.57–0.93; 95% CI 0.74–0.80), respectively (Table 2). Comparing normal-appearing scores (0–1) vs. pathological scores (2–3), the Light's kappa value was substantial both for the De Vita et al. score (kappa value: 0.68; range 0.37–0.86; 95% CI 0.63–0.72) and the OMERACT score (kappa value: 0.71; range 0.42–0.92; 95% CI 0.65–0.75) (Table 2). Similar results were obtained in the second round of the exercise (Table 2). Unweighted kappa and weighted linear kappa of the inter-rater reliability are presented in Supplementary Tables 4, 5. Higher inter-rater reliability was achieved in PGs compared to SMGs (Table 3).

TABLE 2
www.frontiersin.org

Table 2. Inter-rater reliability.

TABLE 3
www.frontiersin.org

Table 3. Inter-rater reliability in the first and second round: comparison between parotid and submandibular glands.

Intra-Rater Reliability Among Sonographers With Different Levels of Experience and Use of SGUS Scores

The intra-rater reliability for the De Vita et al. score and the OMERACT score was almost perfect in all groups. For the De Vita et al. score, the Light's kappa ranged from 0.84 for U-NE (0.79–0.88; 95% CI 0.82–0.86) to 0.88 for NU-E (0.81–0.95; 95% CI 0.85–0.92). For the OMERACT score the Light's kappa ranged from 0.85 for U-NE (0.82–0.86; 95% CI 0.84–0.85) to 0.91 for NU-E (0.84–0.95; 95% CI 0.87–0.92) (Table 4).

TABLE 4
www.frontiersin.org

Table 4. Intra-rater reliability among different group of sonographers.

Inter-Rater Reliability Among Sonographers With Different Levels of Experience and Use of SGUS Scores

The Light's kappa of the four groups showed a substantial level of inter-reliability for the De Vita et al. and the OMERACT scores in both rounds (Table 5). For the De Vita et al. score, the Light's kappa of the first round ranged from 0.71 for U-NE (0.66–0.75) to 0.79 for NU-NE (0.75–0.84). For OMERACT score the Light's kappa of the first round ranged from 0.78 for U-E (0.75–0.81), U-NE (0.74–0.81), and NU-E (0.74–0.82) to 0.79 for NU-NE (0.73–0.84) (Table 5).

TABLE 5
www.frontiersin.org

Table 5. First and second round inter-rater reliability among different groups of sonographers.

Discussion

In this web-based reliability exercise, two different semi-quantitative SGUS scores for pSS proved to be reliable for the sonographic evaluation of the major SGs. In addition, regardless of the level of the sonographer's experience, an almost perfect intra-rater reliability, and substantial inter-rater reliability, were reached. Finally, images and data of the present study will be publicly available to facilitate further investigations.

Few previous studies evaluated the reproducibility of SGUS in pSS, usually with few experts and with variable results (8, 9, 11). Recently the authors of the OMERACT score of SGUS in pSS highlighted a good reliability for their score among 25 experts (16). This study involved an equally relevant number of raters, but also with different levels of expertise. In order to use SGUS as an OMI and as an item for pSS classification, its reliability must be tested, and it is recommended that the weighted kappa should be >0.7 (25). Over the past years, SGUS has received a growing interest as it is a non-invasive and easily performed technique for the management of pSS (26). Furthermore, in clinical practice, SGUS semi-quantitative scores are easy to apply and have a good discriminatory power between pathological and normal-appearing major SGs (7, 8, 10). This exercise tested the application of two different, easy-to-apply, 0–3 semi-quantitative scores for SGUS, namely the ones developed by De Vita et al. in 1992 and by OMERACT in 2019. The former includes features of both inflammation (i.e., hypo/anechoic areas) and damage (i.e., hyperechoic bands), whereas the latter, including mainly features of glandular inflammation, was built following the recent OMI recommendations. In this study, both the scores showed an almost perfect intra-rater reliability and substantial inter-rater reliability among 20 sonographers with different levels of experience and knowledge of SGUS scores. The number of involved sonographers and the stratification of the sonographers, based on their experience, are the main strengths of this study. In this reliability exercise, being a non-expert and/or a non-user did not significantly impact the level of agreement among raters. Importantly, however, a support for SGUS evaluation and scoring was given to raters, by means of a dedicated atlas of images. We did not investigate whether the less expert sonographers were those mainly using the atlas or not, since it was poorly feasible. Further studies, in any case, should better define the optimal way to support SGUS rating in pSS. The automatic scoring of SGUS by image segmentation and artificial intelligence is also being evaluated in HarmonicSS.

As already highlighted by the OMERACT study, the reliability among PGs and SMGs was different also in this study, and worse in the SMGs than in the PGs for both the tested scores (16). This could be in part expected since a mild inhomogeneity (e.g., grade 1 for both the scores) of the SMGs can be difficult to be differentiated from the normal gland. The main limitation of the study was the absence of a patient-based exercise; ideally, reliability testing should also be performed in the clinical setting with the patient, and not with the sole images. In this scenario, practical sonographic skills could make the difference among groups with different levels of experience, but a high number of sonographers are needed, making this type of exercise challenging to plan. Furthermore, the presence of only two raters in the NU-NE group could be another study limitation. In this multi-center reliability exercise, groups with an equal number of participants could not be defined a priori, since the choice of sonographers was made by each center involved in the European project.

In conclusion, this study focused on SGUS reliability, i.e., the main limit for a wider use of SGUS in pSS. Both the tested SGUS scores proved to be reliable for the evaluation of pSS patients and this reinforces and supports the reliability of SGUS as highlighted by the OMERACT study (16). Furthermore, in this study the agreement was independent of the years of experience of sonographers and of their previous use of the tested scores. Overall, in our opinion, major evidence to further encourage the use of SGUS in pSS in the next future is provided.

Patient and Public Involvment in Research

EULAR PARE and SSF–Sjögren's Syndrome Foundation have an advisory role in HarmonicSS and will continuously monitor and evaluate the project (outcomes) in terms of impact to patients. Also, EULAR PARE and SSF have a major role in the dissemination of the results to patient associations and the public. https://www.harmonicss.eu/patients-advisory-group/.

Data Availability Statement

The raw data supporting the conclusions of this article will be made available by the authors, without undue reservation.

Ethics Statement

The studies involving human participants were reviewed and approved by CEUR-2017-Os-027-ASUIUD. The patients/participants provided their written informed consent to participate in this study.

Author Contributions

AZ, SZ, AT, AV, AH, VM, GC, MC, KD, OD, DE, FF, AG, GG, IG, DH, MJ, SJ-J, PM, SP, CP, MS, NF, AGT, FV, and SD: conception and design. AZ, AT, and FV: statistical analysis. AZ, SZ, and SD: wrote the manuscript and interpretation of the results. All authors: contributed to the article and approved the submitted version.

Funding

This study was included in the Workpackage 7 of HarmonicSS, an EU-funded, Horizon 2020 Research Project on SS (European Union grant 731944).

Conflict of Interest

The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.

The handling editor declared a shared affiliation, though no other collaboration, with the authors GC and CP.

Supplementary Material

The Supplementary Material for this article can be found online at: https://www.frontiersin.org/articles/10.3389/fmed.2020.581248/full#supplementary-material

Abbreviations

ACR-EULAR, American College of Rheumatology/European League Against Rheumatism; GRAAS, Guidelines for Reporting Reliability and Agreement Studies; NU-E, non-users and experts; NU-NE, non-users and non-experts; OMERACT, Outcome Measures in Rheumatology Clinical Trials; OMI, outcome measure instruments; PG, parotid gland; pSS, primary Sjögren's syndrome; SGs, salivary glands; SGUS, salivary gland ultrasound; SMG, submandibular gland; U-E, user and experts; U-NE, users and non-experts.

References

1. Moutsopoulos HM. Sjögren's syndrome: autoimmune epithelitis. Clin Immunol Immunopathol. (1994) 72:162–5. doi: 10.1006/clin.1994.1123

PubMed Abstract | CrossRef Full Text | Google Scholar

2. Vitali C, Palombi G, Baldini C, Benucci M, Bombardieri S, Covelli M, et al. Sjögren's syndrome disease damage index and disease activity index: scoring systems for the assessment of disease damage and disease activity in Sjögren's syndrome, derived from an analysis of a cohort of Italian patients. Arthritis Rheum. (2007) 56:2223–31. doi: 10.1002/art.22658

PubMed Abstract | CrossRef Full Text | Google Scholar

3. De Vita S, Zabotti A, Gandolfo S. Current limitations and ongoing initiatives to evaluate the activity, damage and outcome of primary Sjögren's syndrome. Clin Exp Rheumatol. (2019) 37(Suppl. 118):24–6.

PubMed Abstract | Google Scholar

4. De Vita S, Boiocchi M, Sorrentino D, Carbone A, Avellini C, Dolcetti R, et al. Characterization of prelymphomatous stages of B cell lymphoproliferation in Sjögren's syndrome. Arthritis Rheum. (1997) 40:318–31. doi: 10.1002/art.1780400217

PubMed Abstract | CrossRef Full Text | Google Scholar

5. Mitsias DI, Kapsogeorgou EK, Moutsopoulos HM. The role of epithelial cells in the initiation and perpetuation of autoimmune lesions: lessons from Sjogren's syndrome (autoimmune epithelitis). Lupus. (2006) 15:255–61. doi: 10.1191/0961203306lu2290rr

PubMed Abstract | CrossRef Full Text | Google Scholar

6. Pijpe J, Kalk WWI, van der Wal JE, Vissink A, Kluin PM, Roodenburg JLN, et al. Parotid gland biopsy compared with labial biopsy in the diagnosis of patients with primary Sjogren's syndrome. Rheumatology. (2007) 46:335–41. doi: 10.1093/rheumatology/kel266

PubMed Abstract | CrossRef Full Text | Google Scholar

7. De Vita S, Lorenzon G, Rossi G, Sabella M, Fossaluzza V. Salivary gland echography in primary and secondary Sjögren's syndrome. Clin Exp Rheumatol. (1992) 10:351–6.

PubMed Abstract | Google Scholar

8. Hocevar A, Ambrozic A, Rozman B, Kveder T, Tomsic M. Ultrasonographic changes of major salivary glands in primary Sjogren's syndrome. Diagnostic value of a novel scoring system. Rheumatology. (2005) 44:768–72. doi: 10.1093/rheumatology/keh588

PubMed Abstract | CrossRef Full Text | Google Scholar

9. Delli K, Arends S, van Nimwegen JF, Dijkstra PU, Stel AJ, Spijkervet FKL, et al. Ultrasound of the major salivary glands is a reliable imaging technique in patients with clinically suspected primary Sjögren's syndrome. Ultraschall Med. (2018) 39:328–33. doi: 10.1055/s-0043-104631

PubMed Abstract | CrossRef Full Text | Google Scholar

10. Jousse-Joulin S, Milic V, Jonsson MV, Plagou A, Theander E, Luciano N, et al. Is salivary gland ultrasonography a useful tool in Sjögren's syndrome? A systematic review. Rheumatology. (2016) 55:789–800. doi: 10.1093/rheumatology/kev385

PubMed Abstract | CrossRef Full Text | Google Scholar

11. Salaffi F, Carotti M, Iagnocco A, Luccioli F, Ramonda R, Sabatini E, et al. Ultrasonography of salivary glands in primary Sjögren's syndrome: a comparison with contrast sialography and scintigraphy. Rheumatology. (2008) 47:1244–9. doi: 10.1093/rheumatology/ken222

PubMed Abstract | CrossRef Full Text | Google Scholar

12. Jousse-Joulin S, Nowak E, Cornec D, Brown J, Carr A, Carotti M, et al. Salivary gland ultrasound abnormalities in primary Sjögren's syndrome: consensual US-SG core items definition and reliability. RMD Open. (2017) 3:e000364. doi: 10.1136/rmdopen-2016-000364

PubMed Abstract | CrossRef Full Text | Google Scholar

13. Fox RI. Is salivary gland ultrasonography a useful tool in Sjögren's syndrome? Rheumatology. (2016) 55:773–4. doi: 10.1093/rheumatology/kev409

PubMed Abstract | CrossRef Full Text | Google Scholar

14. Vitali C, Carotti M, Salaffi F. Is it the time to adopt salivary gland ultrasonography as an alternative diagnostic tool for the classification of patients with Sjögren's syndrome? Comment on the article by Cornec et al. Arthritis Rheum. (2013) 65:1950. doi: 10.1002/art.37945

PubMed Abstract | CrossRef Full Text | Google Scholar

15. Shiboski CH, Shiboski SC, Seror R, Criswell LA, Labetoulle M, Lietman TM, et al. 2016 American College of Rheumatology/European League Against Rheumatism classification criteria for primary Sjögren's syndrome: a consensus and data-driven methodology involving three international patient cohorts. Ann Rheum Dis. (2017) 76:9–16. doi: 10.1136/annrheumdis-2016-210571

PubMed Abstract | CrossRef Full Text | Google Scholar

16. Jousse-Joulin S, D'Agostino MA, Nicolas C, Naredo E, Ohrndorf S, Backhaus M, et al. Video clip assessment of a salivary gland ultrasound scoring system in Sjögren's syndrome using consensual definitions: an OMERACT ultrasound working group reliability exercise. Ann Rheum Dis. (2019) 78:967–73. doi: 10.1136/annrheumdis-2019-215024

PubMed Abstract | CrossRef Full Text | Google Scholar

17. Jousse-Joulin S, Gatineau F, Baldini C, Baer A, Barone F, Bootsma H, et al. Weight of salivary gland ultrasonography compared to other items of the 2016 ACR/EULAR classification criteria for Primary Sjögren's syndrome. J Intern Med. (2020) 287:180–8. doi: 10.1111/joim.12992

PubMed Abstract | CrossRef Full Text | Google Scholar

18. Kottner J, Audigé L, Brorson S, Donner A, Gajewski BJ, Hróbjartsson A, et al. Guidelines for Reporting Reliability and Agreement Studies (GRRAS) were proposed. J Clin Epidemiol. (2011) 64:96–106. doi: 10.1016/j.jclinepi.2010.03.002

PubMed Abstract | CrossRef Full Text | Google Scholar

19. Zhou M, Song S, Wu S, Duan T, Chen L, Ye J, et al. Diagnostic accuracy of salivary gland ultrasonography with different scoring systems in Sjögren's syndrome: a systematic review and meta-analysis. Sci Rep. (2018) 8:17128. doi: 10.1038/s41598-018-35288-5

PubMed Abstract | CrossRef Full Text | Google Scholar

20. Luciano N, Baldini C, Tarantini G, Ferro F, Sernissi F, Varanini V, et al. Ultrasonography of major salivary glands: a highly specific tool for distinguishing primary Sjögren's syndrome from undifferentiated connective tissue diseases. Rheumatology. (2015) 54:2198–204. doi: 10.1093/rheumatology/kev253

PubMed Abstract | CrossRef Full Text | Google Scholar

21. Zabotti A, Zandonella Callegher S, Gandolfo S, Valent F, Giovannini I, Cavallaro E, et al. Hyperechoic bands detected by salivary gland ultrasonography are related to salivary impairment in established Sjögren's syndrome. Clin Exp Rheumatol. (2019) 37(Suppl. 118):146–52.

PubMed Abstract | Google Scholar

22. Milic V, Colic J, Cirkovic A, Stanojlovic S, Damjanov N. Disease activity and damage in patients with primary Sjogren's syndrome: prognostic value of salivary gland ultrasonography. PLoS ONE. (2019) 14:e0226498. doi: 10.1371/journal.pone.0226498

PubMed Abstract | CrossRef Full Text | Google Scholar

23. Terslev L, Naredo E, Keen HI, Bruyn GAW, Iagnocco A, Wakefield RJ, et al. The OMERACT stepwise approach to select and develop imaging outcome measurement instruments: the musculoskeletal ultrasound example. J Rheumatol. (2019) 46:1394–400. doi: 10.3899/jrheum.181158

PubMed Abstract | CrossRef Full Text | Google Scholar

24. Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. (1977) 33:159–74. doi: 10.2307/2529310

PubMed Abstract | CrossRef Full Text | Google Scholar

25. Prinsen CAC, Vohra S, Rose MR, Boers M, Tugwell P, Clarke M, et al. How to select outcome measurement instruments for outcomes included in a “Core Outcome Set” - a practical guideline. Trials. (2016) 17:449. doi: 10.1186/s13063-016-1555-2

CrossRef Full Text | Google Scholar

26. Baldini C, Zabotti A, Filipovic N, Vukicevic A, Luciano N, Ferro F, et al. Imaging in primary Sjögren's syndrome: the ‘obsolete and the new’. Clin Exp Rheumatol. (2018) 36 (Suppl. 112):215–21.

PubMed Abstract | Google Scholar

Keywords: Sjögren's syndrome, scoring system, classification criteria, reliability exercise, salivary gland ultrasonography

Citation: Zabotti A, Zandonella Callegher S, Tullio A, Vukicevic A, Hocevar A, Milic V, Cafaro G, Carotti M, Delli K, De Lucia O, Ernst D, Ferro F, Gattamelata A, Germanò G, Giovannini I, Hammenfors D, Jonsson MV, Jousse-Joulin S, Macchioni P, Parisi S, Perricone C, Stradner MH, Filipovic N, Tzioufas AG, Valent F and De Vita S (2020) Salivary Gland Ultrasonography in Sjögren's Syndrome: A European Multicenter Reliability Exercise for the HarmonicSS Project. Front. Med. 7:581248. doi: 10.3389/fmed.2020.581248

Received: 08 July 2020; Accepted: 21 October 2020;
Published: 23 November 2020.

Edited by:

Alessia Alunno, University of Perugia, Italy

Reviewed by:

Cheng-De Yang, Shanghai Jiao Tong University, China
Vasco C. Romão, University of Lisbon, Portugal

Copyright © 2020 Zabotti, Zandonella Callegher, Tullio, Vukicevic, Hocevar, Milic, Cafaro, Carotti, Delli, De Lucia, Ernst, Ferro, Gattamelata, Germanò, Giovannini, Hammenfors, Jonsson, Jousse-Joulin, Macchioni, Parisi, Perricone, Stradner, Filipovic, Tzioufas, Valent and De Vita. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

*Correspondence: Salvatore De Vita, salvatore.devita@asufc.sanita.fvg.it

Download