The effect of Er:YAG laser and different surface conditioning procedures on microtensile bond strength of the fissure sealant containing amorphous calcium phosphate after artificial aging
Murat UNALIhsan HUBBEZOGLURecai ZANFatih OZNURHAN
Author information
JOURNAL FREE ACCESS

2014 Volume 33 Issue 1 Pages 21-26

Details
Abstract

The present study aimed to compare post-aging microtensile values of fissure sealant(FS) containing amorphous calcium phosphate(ACP) with or without bonding after various enamel-etching methods. The buccal enamel surfaces of teeth were prepared and divided into five main groups according to enamel etching (Group 1; acid-etching, Group 2; air-abrasion, Group 3; 2W, Group 4; 3W, and Group 5; 4W of Er:YAG laser). Each main group was subdivided as with(Subgroup B) or without(Subgroup A) a bonding system. We applied FS-containing ACP to etched enamel surfaces. All specimens were aged by Thermocycling and water bath. We then measured microtensile bond strengths and analyzed data with two-way ANOVA and Tukey’s tests. We found a statistically significant difference between Group 1 and Group 2, between Subgroup B of Group 5 and Subgroups B of all other groups, and between Subgroups A and Subgroups B of all main groups (p<0.01). Er:YAG laser-etching may be an alternative enamel etching method to acid-etching for ACP-containing FS.