Skip to main content
Erschienen in: Clinical Oral Investigations 5/2016

23.09.2015 | Original Article

Long-term behavior of double crown retained dentures with metal and metal-free secondary crowns and frameworks made of Vectris© on all-ceramic primary crowns: a prospective, randomized clinical trial up to 14 years

verfasst von: T. Zahn, B. Zahn, S. Janko, P. Weigl, S. Gerhardt-Szép, H. C. Lauer

Erschienen in: Clinical Oral Investigations | Ausgabe 5/2016

Einloggen, um Zugang zu erhalten

Abstract

Objectives

This prospective randomized clinical trial aimed to evaluate the long-term behavior of metal-free double crown retained dentures with secondary crowns and dental frameworks made of the fiber-reinforced composite Vectris© on all-ceramic primary crowns (IPS Empress 2©) over a period of up to 14 years and to subsequently evaluate patient satisfaction. For the control group, electroplated gold copings and metal frameworks were used.

Materials and methods

A total of 29 patients were treated with a total of 37 prostheses on 165 primary crowns. Of these 37 prostheses, 27 were allotted to the control group and 10 to the test group. The mean observation time was 91 ± 57 months; patient satisfaction surveys were conducted over 77 ± 59 months.

Results

Success rates in both groups were compared using Kaplan–Meier survival curves and log-rank test. Up to about 3 years, both types of prostheses exhibited similar success rates. Afterwards, a massive decrease in the Vectris© curve could be noted, whereas the metal curve dropped only slightly. This difference was also statistically significant (p = 0.032361). There was a comparable susceptibility to damages in both groups: 88.9 % (control) and 90 % (test), respectively, of the prostheses had to be repaired within the period of investigation (p = 0,121). Damages of the Vectris© secondary crowns could be detected significantly more often compared to the electroformed gold copings (p < 0.00005). Patient satisfaction with the restorations was comparably high in both groups.

Conclusion

Metal-free secondary crowns and denture frameworks made with the glass fiber-reinforced composite material Vectris© showed a lower survival rate than the electroplated gold copings and metal frameworks. Primary crowns made of IPS Empress 2© had insufficient stability. Exclusively high-strength zirconia ceramics should be recommended for this indication.

Clinical relevance

Both clinical and statistical data indicated the superiority of the restorations made with electroplated secondary crowns and metal framework. Therefore, the use of Vectris© cannot be recommended for the fabrication of double crown retained removable dentures as permanent restorations.
Literatur
1.
Zurück zum Zitat Beschnidt SM, Chitmongkolsuk S, Prull R (2001) Telescopic crown-retained removable partial dentures: review and case report. Compend Contin Educ Dent 22:927–928, 929–32, 934 passim; quiz 942 Beschnidt SM, Chitmongkolsuk S, Prull R (2001) Telescopic crown-retained removable partial dentures: review and case report. Compend Contin Educ Dent 22:927–928, 929–32, 934 passim; quiz 942
2.
Zurück zum Zitat Köhler KC (2002) Clinical follow-up about long-term outcome of double-crown-retained removable dentures. Dissertation, University of Frankfurt Köhler KC (2002) Clinical follow-up about long-term outcome of double-crown-retained removable dentures. Dissertation, University of Frankfurt
3.
Zurück zum Zitat Piwowarczyk A, Köhler KC, Bender R, Büchler A, Lauer HC, Ottl P (2007) Prognosis for abutment teeth of removable dentures: a retrospective study. J Prosthodont 16:377–382CrossRefPubMed Piwowarczyk A, Köhler KC, Bender R, Büchler A, Lauer HC, Ottl P (2007) Prognosis for abutment teeth of removable dentures: a retrospective study. J Prosthodont 16:377–382CrossRefPubMed
4.
5.
Zurück zum Zitat Stober T, Bermejo JL, Beck-Mussoter J, Seche AC, Lehmann F, Koob J, Rammelsberg P (2012) Clinical performance of conical and electroplated telescopic double crown-retained partial dentures: a randomized clinical study. Int J Prosthodont 25(3):209–216PubMed Stober T, Bermejo JL, Beck-Mussoter J, Seche AC, Lehmann F, Koob J, Rammelsberg P (2012) Clinical performance of conical and electroplated telescopic double crown-retained partial dentures: a randomized clinical study. Int J Prosthodont 25(3):209–216PubMed
6.
Zurück zum Zitat Wöstmann B, Balkenhol M, Weber A, Ferger P, Rehmann P (2007) Long-term analysis of telescopic crown retained removable partial dentures: survival and need for maintenance. J Dent 35:939–945CrossRefPubMed Wöstmann B, Balkenhol M, Weber A, Ferger P, Rehmann P (2007) Long-term analysis of telescopic crown retained removable partial dentures: survival and need for maintenance. J Dent 35:939–945CrossRefPubMed
7.
Zurück zum Zitat Bär C, Reich S (2008) Telescopically retained removable partial dentures on CAD/CAM generated all-ceramic primary telescopes. Int J Comput Dent 11(2):115–130PubMed Bär C, Reich S (2008) Telescopically retained removable partial dentures on CAD/CAM generated all-ceramic primary telescopes. Int J Comput Dent 11(2):115–130PubMed
8.
Zurück zum Zitat Weigl P, Kleutges D (1998) An innovative and simple therapy concept for removable suprastructures with a new retainer application. In: Weber H, Mönkemeyer UR (eds) Therapy concepts for implant dentistry. Quintessenz, Karlsruhe, pp 117–158 Weigl P, Kleutges D (1998) An innovative and simple therapy concept for removable suprastructures with a new retainer application. In: Weber H, Mönkemeyer UR (eds) Therapy concepts for implant dentistry. Quintessenz, Karlsruhe, pp 117–158
10.
Zurück zum Zitat Di Felice R, Rappelli G, Camaioni E, Cattani M, Meyer JM, Belser UC (2007) Cementable implant crowns composed of cast superstructure frameworks luted to electroformed primary copings: an in vitro retention study. Clin Oral Implants Res 18(1):108–113CrossRefPubMed Di Felice R, Rappelli G, Camaioni E, Cattani M, Meyer JM, Belser UC (2007) Cementable implant crowns composed of cast superstructure frameworks luted to electroformed primary copings: an in vitro retention study. Clin Oral Implants Res 18(1):108–113CrossRefPubMed
11.
Zurück zum Zitat Greven B, Luepke M, von Dorsche SH (2007) Telescoping implant prostheses with intraoral luted galvano mesostructures to improve passive fit. J Prosthet Dent 98(3):239–244CrossRefPubMed Greven B, Luepke M, von Dorsche SH (2007) Telescoping implant prostheses with intraoral luted galvano mesostructures to improve passive fit. J Prosthet Dent 98(3):239–244CrossRefPubMed
12.
Zurück zum Zitat Janko S (2002) Prospective clinical study of intraorally luted double-crown-retained dentures. Dissertation, University of Frankfurt Janko S (2002) Prospective clinical study of intraorally luted double-crown-retained dentures. Dissertation, University of Frankfurt
13.
Zurück zum Zitat Longoni S, Sartori M, Maroni I, Baldoni M (2010) Intraoral luting: modified prosthetic design to achieve passivity, precision of fit, and esthetics for a cement-retained, implant-supported metal-resin-fixed complete denture. J Prosthodont 19(2):166–170. doi:10.1111/j.1532-849X.2009.00526.x CrossRefPubMed Longoni S, Sartori M, Maroni I, Baldoni M (2010) Intraoral luting: modified prosthetic design to achieve passivity, precision of fit, and esthetics for a cement-retained, implant-supported metal-resin-fixed complete denture. J Prosthodont 19(2):166–170. doi:10.​1111/​j.​1532-849X.​2009.​00526.​x CrossRefPubMed
14.
Zurück zum Zitat Dietschi D, Magne P, Holz J (1994) Recent trends in esthetic restorations for posterior teeth. Quintessence Int 25(10):659–677PubMed Dietschi D, Magne P, Holz J (1994) Recent trends in esthetic restorations for posterior teeth. Quintessence Int 25(10):659–677PubMed
15.
Zurück zum Zitat Höland W, Rheinberger V, Apel E, Ritzberger C, Rothbrust F, Kappert H, Krumeich F, Nesper R (2009) Future perspectives of biomaterials for dental restoration. J Eur Ceram Soc 29(7):1291–1297CrossRef Höland W, Rheinberger V, Apel E, Ritzberger C, Rothbrust F, Kappert H, Krumeich F, Nesper R (2009) Future perspectives of biomaterials for dental restoration. J Eur Ceram Soc 29(7):1291–1297CrossRef
16.
Zurück zum Zitat Walia S, Thomas PM, Sandhu H, Santos GC (2009) Restoring esthetics with metal-free ceramics: a case report. J Can Dent Assoc 75(5):353–355PubMed Walia S, Thomas PM, Sandhu H, Santos GC (2009) Restoring esthetics with metal-free ceramics: a case report. J Can Dent Assoc 75(5):353–355PubMed
17.
Zurück zum Zitat Weigl P (1999) All-ceramic primary crowns in the telescope system. In: Heidemann D (ed) Deutscher Zahnärztekalender. Hanser, München – Wien, pp 51–76 Weigl P (1999) All-ceramic primary crowns in the telescope system. In: Heidemann D (ed) Deutscher Zahnärztekalender. Hanser, München – Wien, pp 51–76
18.
Zurück zum Zitat Weigl P, Hahn L, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res 53:320–336CrossRefPubMed Weigl P, Hahn L, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res 53:320–336CrossRefPubMed
19.
Zurück zum Zitat Weigl P, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res 53:337–347CrossRefPubMed Weigl P, Lauer HC (2000) Advanced biomaterials used for a new telescopic retainer for removable dentures. J Biomed Mater Res 53:337–347CrossRefPubMed
20.
Zurück zum Zitat Dabrowa T, Dobrowolska A, Wieleba W (2013) The role of friction in the mechanism of retaining the partial removable dentures with double crown system. Acta Bioeng Biomech 15(4):43–48PubMed Dabrowa T, Dobrowolska A, Wieleba W (2013) The role of friction in the mechanism of retaining the partial removable dentures with double crown system. Acta Bioeng Biomech 15(4):43–48PubMed
21.
Zurück zum Zitat Körber K, Körber S, Ludwig K (1996) Experimental studies about the stiffening effect of fibre-reinforced bridge frameworks made of Vectris after facing with the ceromer Targis. Quintessenz Zahntech 22:1343–1354 Körber K, Körber S, Ludwig K (1996) Experimental studies about the stiffening effect of fibre-reinforced bridge frameworks made of Vectris after facing with the ceromer Targis. Quintessenz Zahntech 22:1343–1354
22.
Zurück zum Zitat Bohlsen F, Kern M (2003) Clinical outcome of glass-fiber-reinforced crowns and fixed partial dentures: a three-year retrospective study. Quintessence Int 34(7):493–496PubMed Bohlsen F, Kern M (2003) Clinical outcome of glass-fiber-reinforced crowns and fixed partial dentures: a three-year retrospective study. Quintessence Int 34(7):493–496PubMed
23.
Zurück zum Zitat Göhring TN, Möhrmann WH, Lutz F (1999) Clinical and scanning electron microscopic evaluation of fiber-reinforced inlay fixed partial dentures: preliminary after one year. J Prosthet Dent 82:662–668CrossRefPubMed Göhring TN, Möhrmann WH, Lutz F (1999) Clinical and scanning electron microscopic evaluation of fiber-reinforced inlay fixed partial dentures: preliminary after one year. J Prosthet Dent 82:662–668CrossRefPubMed
24.
Zurück zum Zitat Langner J (1997) Fiber-reinforced composite Targis and Vectris for crowns and bridges. Quintessenz Zahntech 23:631–646 Langner J (1997) Fiber-reinforced composite Targis and Vectris for crowns and bridges. Quintessenz Zahntech 23:631–646
25.
Zurück zum Zitat Loose M, Rosentritt M, Leibrock A, Behr M, Handel G (1998) In-vitro study of fracture strength and marginal adaptation of fiber-reinforced composite versus all-ceramic fixed partial dentures. Eur J Prosthodont Restor Dent 6:55–62PubMed Loose M, Rosentritt M, Leibrock A, Behr M, Handel G (1998) In-vitro study of fracture strength and marginal adaptation of fiber-reinforced composite versus all-ceramic fixed partial dentures. Eur J Prosthodont Restor Dent 6:55–62PubMed
26.
Zurück zum Zitat Behr M, Rosentritt M, Leibrock A, Schneider-Feyrer S, Handel G (1999) In-vitro study of fracture strength and marginal adaptation of fibre-reinforced adhesive fixed partial inlay dentures. J Dent 27(2):163–168CrossRefPubMed Behr M, Rosentritt M, Leibrock A, Schneider-Feyrer S, Handel G (1999) In-vitro study of fracture strength and marginal adaptation of fibre-reinforced adhesive fixed partial inlay dentures. J Dent 27(2):163–168CrossRefPubMed
27.
Zurück zum Zitat Behr M, Rosentritt M, Handel G (2003) Fiber-reinforced composite crowns and FPDs: a clinical report. Int J Prosthodont 16(3):239–243PubMed Behr M, Rosentritt M, Handel G (2003) Fiber-reinforced composite crowns and FPDs: a clinical report. Int J Prosthodont 16(3):239–243PubMed
28.
Zurück zum Zitat Perea L, Matinlinna JP, Tolvanen M, Lassila LV, Vallittu PKJ (2014) Fiber-reinforced composite fixed dental prostheses with various pontics. Adhes Dent 16(2):161–168. doi:10.3290/j.jad.a30755 Perea L, Matinlinna JP, Tolvanen M, Lassila LV, Vallittu PKJ (2014) Fiber-reinforced composite fixed dental prostheses with various pontics. Adhes Dent 16(2):161–168. doi:10.​3290/​j.​jad.​a30755
29.
Zurück zum Zitat Schulz KF, Grimes DA (2002) Generation of allocation sequences in randomised trials: chance, not choice. Lancet 359(9305):515–519CrossRefPubMed Schulz KF, Grimes DA (2002) Generation of allocation sequences in randomised trials: chance, not choice. Lancet 359(9305):515–519CrossRefPubMed
32.
Zurück zum Zitat Bergman B, Ericson A, Molin M (1996) Long-term clinical results after treatment with conical crown-retained dentures. Int J Prosthodont 9:533–538PubMed Bergman B, Ericson A, Molin M (1996) Long-term clinical results after treatment with conical crown-retained dentures. Int J Prosthodont 9:533–538PubMed
33.
Zurück zum Zitat Heners M, Walther W (1988) Abutment distribution and rigid support—a clinical long-term study. Dtsch Zahnärztl Z 43:1122–1126PubMed Heners M, Walther W (1988) Abutment distribution and rigid support—a clinical long-term study. Dtsch Zahnärztl Z 43:1122–1126PubMed
34.
Zurück zum Zitat Hulten J, Tillström B, Nilner K (1993) Long-term clinical evaluation of conical crown retained dentures. Swed Dent J 17:225–234PubMed Hulten J, Tillström B, Nilner K (1993) Long-term clinical evaluation of conical crown retained dentures. Swed Dent J 17:225–234PubMed
35.
Zurück zum Zitat Trimpou G (2006) Long-term clinical trial of implant retained double crown based overdentures by using prefabricated primary and secondary components of the Ankylos-implant system. Dissertation, University of Frankfurt Trimpou G (2006) Long-term clinical trial of implant retained double crown based overdentures by using prefabricated primary and secondary components of the Ankylos-implant system. Dissertation, University of Frankfurt
36.
Zurück zum Zitat Wagner B, Kern M (2000) Clinical evaluation of removable partial dentures 10 years after insertion: success rates, hygienic problems, and technical failures. Clin Oral Investig 4:74–80CrossRefPubMed Wagner B, Kern M (2000) Clinical evaluation of removable partial dentures 10 years after insertion: success rates, hygienic problems, and technical failures. Clin Oral Investig 4:74–80CrossRefPubMed
37.
Zurück zum Zitat Widbom T, Löfquist L, Widbom C, Söderfeldt B, Kronström M (2004) Tooth-supported telescopic crown-retained dentures: an up to 9-year retrospective clinical follow-up study. Int J Prosthodont 17:29–34PubMed Widbom T, Löfquist L, Widbom C, Söderfeldt B, Kronström M (2004) Tooth-supported telescopic crown-retained dentures: an up to 9-year retrospective clinical follow-up study. Int J Prosthodont 17:29–34PubMed
38.
Zurück zum Zitat Manicone PF, Rossi Iommetti P, Raffaelli L (2007) An overview of zirconia ceramics: basic properties and clinical applications. J Dent 35:819–826CrossRefPubMed Manicone PF, Rossi Iommetti P, Raffaelli L (2007) An overview of zirconia ceramics: basic properties and clinical applications. J Dent 35:819–826CrossRefPubMed
39.
Zurück zum Zitat Yilmaz H, Aydin C, Gul BE (2007) Flexural strength and fracture toughness of dental core ceramics. J Prosthet Dent 98:120–128CrossRefPubMed Yilmaz H, Aydin C, Gul BE (2007) Flexural strength and fracture toughness of dental core ceramics. J Prosthet Dent 98:120–128CrossRefPubMed
40.
Zurück zum Zitat Bayer S, Kraus D, Keilig L, Gölz L, Stark H, Enkling N (2012) Changes in retention force with electroplated copings on conical crowns: a comparison of gold and zirconia primary crowns. Int J Oral Maxillofac Implants 27(3):577–585PubMed Bayer S, Kraus D, Keilig L, Gölz L, Stark H, Enkling N (2012) Changes in retention force with electroplated copings on conical crowns: a comparison of gold and zirconia primary crowns. Int J Oral Maxillofac Implants 27(3):577–585PubMed
42.
Zurück zum Zitat Rösch R, Mericske-Stern R (2008) Zirconia and removable partial dentures. Schweiz Monatsschr Zahnmed 118:959–966PubMed Rösch R, Mericske-Stern R (2008) Zirconia and removable partial dentures. Schweiz Monatsschr Zahnmed 118:959–966PubMed
43.
Zurück zum Zitat Turp I, Bozdağ E, Sünbüloğlu E, Kahruman C, Yusufoğlu I, Bayraktar G (2014) Retention and surface changes of zirconia primary crowns with secondary crowns of different materials. Clin Oral Investig Jan 31 Turp I, Bozdağ E, Sünbüloğlu E, Kahruman C, Yusufoğlu I, Bayraktar G (2014) Retention and surface changes of zirconia primary crowns with secondary crowns of different materials. Clin Oral Investig Jan 31
44.
Zurück zum Zitat Zafiropoulos GG, Rebbe J, Thielen U, Deli G, Beaumont C, Hoffmann O (2010) Zirconia removable telescopic dentures retained on teeth or implants for maxilla rehabilitation. Three-year observation of three cases. J Oral Implantol 36(6):455–465. doi:10.1563/AAID-JOI-D-09-00065 CrossRefPubMed Zafiropoulos GG, Rebbe J, Thielen U, Deli G, Beaumont C, Hoffmann O (2010) Zirconia removable telescopic dentures retained on teeth or implants for maxilla rehabilitation. Three-year observation of three cases. J Oral Implantol 36(6):455–465. doi:10.​1563/​AAID-JOI-D-09-00065 CrossRefPubMed
45.
Zurück zum Zitat Behr M, Hofmann E, Rosentritt M, Lang R, Handel G (2000) Technical failure rates of double crown-retained removable partial dentures. Clin Oral Investig 4:87–90CrossRefPubMed Behr M, Hofmann E, Rosentritt M, Lang R, Handel G (2000) Technical failure rates of double crown-retained removable partial dentures. Clin Oral Investig 4:87–90CrossRefPubMed
46.
Zurück zum Zitat Hofmann E, Behr M, Handel G (2002) Frequency and costs of technical failures of clasp- and double crown-retained removable partial dentures. Clin Oral Investig 6:104–108CrossRefPubMed Hofmann E, Behr M, Handel G (2002) Frequency and costs of technical failures of clasp- and double crown-retained removable partial dentures. Clin Oral Investig 6:104–108CrossRefPubMed
47.
Zurück zum Zitat Igarashi Y, Goto T (1997) Ten-year follow-up study of conical crown-retained dentures. Int J Prosthodont 10:149–155PubMed Igarashi Y, Goto T (1997) Ten-year follow-up study of conical crown-retained dentures. Int J Prosthodont 10:149–155PubMed
48.
Zurück zum Zitat Awad MA, Feine JS (1998) Measuring patient satisfaction with mandibular prostheses. Community Dent Oral Epidemiol 26:400–405CrossRefPubMed Awad MA, Feine JS (1998) Measuring patient satisfaction with mandibular prostheses. Community Dent Oral Epidemiol 26:400–405CrossRefPubMed
49.
Zurück zum Zitat Awad MA, Locker D, Korner-Bitensky N, Feine JS (2000) Measuring the effect of intra-oral implant rehabilitation on health-related quality of life in a randomized controlled clinical trial. J Dent Res 79:1659–1663CrossRefPubMed Awad MA, Locker D, Korner-Bitensky N, Feine JS (2000) Measuring the effect of intra-oral implant rehabilitation on health-related quality of life in a randomized controlled clinical trial. J Dent Res 79:1659–1663CrossRefPubMed
50.
Zurück zum Zitat Berg E (1984) The influence of some anamnestic, demographic, and clinical variables on patient acceptance of new complete dentures. Acta Odontol Scand 42:119–127CrossRefPubMed Berg E (1984) The influence of some anamnestic, demographic, and clinical variables on patient acceptance of new complete dentures. Acta Odontol Scand 42:119–127CrossRefPubMed
51.
Zurück zum Zitat Bergman B, Carlsson GE (1972) Review of 54 complete denture wearers. Patients’ opinions 1 year after treatment. Acta Odontol Scand 30:399–414CrossRefPubMed Bergman B, Carlsson GE (1972) Review of 54 complete denture wearers. Patients’ opinions 1 year after treatment. Acta Odontol Scand 30:399–414CrossRefPubMed
52.
Zurück zum Zitat Ettinger RL, Jakobsen JR (1997) A comparison of patient satisfaction and dentist evaluation of overdenture therapy. Community Dent Oral Epidemiol 25:223–227CrossRefPubMed Ettinger RL, Jakobsen JR (1997) A comparison of patient satisfaction and dentist evaluation of overdenture therapy. Community Dent Oral Epidemiol 25:223–227CrossRefPubMed
53.
Zurück zum Zitat Ericson A, Nilsson B, Bergman B (1991) Clinical results in patients treated with conical crown supported restorations. Quintessenz 8:1237–1252 Ericson A, Nilsson B, Bergman B (1991) Clinical results in patients treated with conical crown supported restorations. Quintessenz 8:1237–1252
54.
Zurück zum Zitat Gernet W, Adam P, Reither W (1983) Follow-up studies of partial prostheses using K. H. Körber's conical crowns. Dtsch Zahnärztl Z 38:998–1001PubMed Gernet W, Adam P, Reither W (1983) Follow-up studies of partial prostheses using K. H. Körber's conical crowns. Dtsch Zahnärztl Z 38:998–1001PubMed
55.
Zurück zum Zitat Grossmann AC, Hassel AJ, Schilling O, Lehmann F, Koob A, Rammelsberg P (2007) Treatment with double crown-retained removable partial dentures and oral health-related quality of life in middle- and high-aged patients. Int J Prosthodont 20:576–578PubMed Grossmann AC, Hassel AJ, Schilling O, Lehmann F, Koob A, Rammelsberg P (2007) Treatment with double crown-retained removable partial dentures and oral health-related quality of life in middle- and high-aged patients. Int J Prosthodont 20:576–578PubMed
56.
Zurück zum Zitat John MT, Slade GD, Szentpétery A, Setz JM (2004) Oral health-related quality of life in patients treated with fixed, removable, and complete dentures 1 month and 6 to 12 months after treatment. Int J Prosthodont 17:503–511PubMed John MT, Slade GD, Szentpétery A, Setz JM (2004) Oral health-related quality of life in patients treated with fixed, removable, and complete dentures 1 month and 6 to 12 months after treatment. Int J Prosthodont 17:503–511PubMed
57.
Zurück zum Zitat Heydecke G (2002) Patient satisfaction as outcome measure in clinical studies of oral health. Schweiz Monatsschr Zahnmed 112:330–336PubMed Heydecke G (2002) Patient satisfaction as outcome measure in clinical studies of oral health. Schweiz Monatsschr Zahnmed 112:330–336PubMed
58.
Zurück zum Zitat Slade GD (1997) Derivation and validation of a short-form oral health impact profile. Community Dent Oral Epidemiol 25(4):284–290CrossRefPubMed Slade GD (1997) Derivation and validation of a short-form oral health impact profile. Community Dent Oral Epidemiol 25(4):284–290CrossRefPubMed
59.
Zurück zum Zitat Slade GD, Spencer AJ (1994) Development and evaluation of the oral health impact profile. Community Dent Health 11(1):3–11PubMed Slade GD, Spencer AJ (1994) Development and evaluation of the oral health impact profile. Community Dent Health 11(1):3–11PubMed
60.
Zurück zum Zitat Lachin JM, Matts JP, Wei LJ (1988) Randomization in clinical trials: conclusions and recommendations. Control Clin Trials 9:365–374CrossRefPubMed Lachin JM, Matts JP, Wei LJ (1988) Randomization in clinical trials: conclusions and recommendations. Control Clin Trials 9:365–374CrossRefPubMed
61.
Zurück zum Zitat Altman DG, Doré CJ (1990) Randomisation and baseline comparisons in clinical trials. Lancet 335(8682):149–153CrossRefPubMed Altman DG, Doré CJ (1990) Randomisation and baseline comparisons in clinical trials. Lancet 335(8682):149–153CrossRefPubMed
63.
Zurück zum Zitat Bernhart G, Koob A, Schmitter M, Gabbert O, Stober T, Rammelsberg P (2012) Clinical success of implant-supported and tooth-implant-supported double crown-retained dentures. Clin Oral Investig 16(4):1031–1037. doi:10.1007/s00784-011-0592-1 CrossRefPubMed Bernhart G, Koob A, Schmitter M, Gabbert O, Stober T, Rammelsberg P (2012) Clinical success of implant-supported and tooth-implant-supported double crown-retained dentures. Clin Oral Investig 16(4):1031–1037. doi:10.​1007/​s00784-011-0592-1 CrossRefPubMed
64.
Zurück zum Zitat Krennmair G, Krainhöfner M, Waldenberger O, Piehslinger E (2007) Dental implants as strategic supplementary abutments for implant-tooth-supported telescopic crown-retained maxillary dentures: a retrospective follow-up study for up to 9 years. Int J Prosthodont 20(6):617–622PubMed Krennmair G, Krainhöfner M, Waldenberger O, Piehslinger E (2007) Dental implants as strategic supplementary abutments for implant-tooth-supported telescopic crown-retained maxillary dentures: a retrospective follow-up study for up to 9 years. Int J Prosthodont 20(6):617–622PubMed
65.
Zurück zum Zitat Nickenig HJ, Spiekermann H, Wichmann M, Andreas SK, Eitner S (2008) Survival and complication rates of combined tooth-implant-supported fixed and removable partial dentures. Int J Prosthodont 21(2):131–137PubMed Nickenig HJ, Spiekermann H, Wichmann M, Andreas SK, Eitner S (2008) Survival and complication rates of combined tooth-implant-supported fixed and removable partial dentures. Int J Prosthodont 21(2):131–137PubMed
66.
Zurück zum Zitat Duncan JP, Freilich MA, Latvis CJ (2000) Fiber-reinforced composite framework for implant-supported overdentures. HJ Prosthet Dent 84:200–204CrossRef Duncan JP, Freilich MA, Latvis CJ (2000) Fiber-reinforced composite framework for implant-supported overdentures. HJ Prosthet Dent 84:200–204CrossRef
67.
Zurück zum Zitat Akin H, Turgut M, Coskun ME (2007) Restoration of an anterior edentulous space with a unique glass fiber-reinforced composite removable partial denture: a case report. J Esthet Restor Dent 19(4):193–197, discussion 198 Akin H, Turgut M, Coskun ME (2007) Restoration of an anterior edentulous space with a unique glass fiber-reinforced composite removable partial denture: a case report. J Esthet Restor Dent 19(4):193–197, discussion 198
68.
69.
Zurück zum Zitat Izgi AD, Eskimez S, Kale E, Değer Y (2011) Directly fabricated inlay-retained glass- and polyethylene fiber-reinforced composite fixed dental prostheses in posterior single missing teeth: a short-term clinical observation. J Adhes Dent 13:383–391PubMed Izgi AD, Eskimez S, Kale E, Değer Y (2011) Directly fabricated inlay-retained glass- and polyethylene fiber-reinforced composite fixed dental prostheses in posterior single missing teeth: a short-term clinical observation. J Adhes Dent 13:383–391PubMed
70.
Zurück zum Zitat Vallittu PK (2004) Survival rates of resin-bonded, glass fiber-reinforced composite fixed partial dentures with a mean follow-up of 42 months: a pilot study. J Prosthet Dent 91:241–246CrossRefPubMed Vallittu PK (2004) Survival rates of resin-bonded, glass fiber-reinforced composite fixed partial dentures with a mean follow-up of 42 months: a pilot study. J Prosthet Dent 91:241–246CrossRefPubMed
71.
Zurück zum Zitat Van Heumen CC, Kreulen CM, Creugers NH (2009) Clinical studies of fiber-reinforced resin-bonded fixed partial dentures: a systematic review. Eur J Oral Sci 117:1–6CrossRefPubMed Van Heumen CC, Kreulen CM, Creugers NH (2009) Clinical studies of fiber-reinforced resin-bonded fixed partial dentures: a systematic review. Eur J Oral Sci 117:1–6CrossRefPubMed
72.
Zurück zum Zitat Van Heumen CC, van Dijken JW, Tanner J, Pikaar R, Lassila LV, Creugers NH, Vallittu PK, Kreulen CM (2009) Five-year survival of 3-unit fiber-reinforced composite fixed partial dentures in the anterior area. Dent Mater 25:820–827CrossRefPubMed Van Heumen CC, van Dijken JW, Tanner J, Pikaar R, Lassila LV, Creugers NH, Vallittu PK, Kreulen CM (2009) Five-year survival of 3-unit fiber-reinforced composite fixed partial dentures in the anterior area. Dent Mater 25:820–827CrossRefPubMed
73.
Zurück zum Zitat Bühler NM, Teubner E, Marinello CP (2011) Zirconia in removable prosthodontics. A case report. Schweiz Monatsschr Zahnmed 121(7–8):659–678PubMed Bühler NM, Teubner E, Marinello CP (2011) Zirconia in removable prosthodontics. A case report. Schweiz Monatsschr Zahnmed 121(7–8):659–678PubMed
74.
Zurück zum Zitat Groesser J, Sachs C, Heiß P, Stadelmann M, Erdelt K, Beuer F (2014) Retention forces of 14-unit zirconia telescopic prostheses with six double crowns made from zirconia—an in vitro study. Clin Oral Investig 18(4):1173–1179. doi:10.1007/s00784-013-1093-1 CrossRefPubMed Groesser J, Sachs C, Heiß P, Stadelmann M, Erdelt K, Beuer F (2014) Retention forces of 14-unit zirconia telescopic prostheses with six double crowns made from zirconia—an in vitro study. Clin Oral Investig 18(4):1173–1179. doi:10.​1007/​s00784-013-1093-1 CrossRefPubMed
75.
Zurück zum Zitat Karl M, Bauernschmidt B (2010) Erste Erfahrungen mit teleskopierendem Zahnersatz aus 100% Zirkoniumdioxid. Quintessenz Zahntech 36:86–94 Karl M, Bauernschmidt B (2010) Erste Erfahrungen mit teleskopierendem Zahnersatz aus 100% Zirkoniumdioxid. Quintessenz Zahntech 36:86–94
77.
Zurück zum Zitat Siewert B, Parra M (2013) Eine neue Werkstoffklasse in der Zahnmedizin. PEEK als Gerüstmaterial bei 12-gliedrigen implantatgetragenen Brücken. Z Zahnärztl Implantol 29:148–159. doi:10.3238/ZZI.2013.0148−0159 Siewert B, Parra M (2013) Eine neue Werkstoffklasse in der Zahnmedizin. PEEK als Gerüstmaterial bei 12-gliedrigen implantatgetragenen Brücken. Z Zahnärztl Implantol 29:148–159. doi:10.​3238/​ZZI.​2013.​0148−0159
78.
Zurück zum Zitat Siewert B, Rieger H (2013) PEEK – Ein “neues” Gerüstmaterial für die metallfreie prothetische Therapie. Quintessenz Zahntech 39(10):2–11 Siewert B, Rieger H (2013) PEEK – Ein “neues” Gerüstmaterial für die metallfreie prothetische Therapie. Quintessenz Zahntech 39(10):2–11
79.
Zurück zum Zitat Stawarczyk B, Beuer F, Wimmer T, Jahn D, Sener B, Roos M, Schmidlin PR (2013) Polyetheretherketone—a suitable material for fixed dental prostheses? J Biomed Mater Res B Appl Biomater 101(7):1209–1216. doi:10.1002/jbm.b.32932 CrossRefPubMed Stawarczyk B, Beuer F, Wimmer T, Jahn D, Sener B, Roos M, Schmidlin PR (2013) Polyetheretherketone—a suitable material for fixed dental prostheses? J Biomed Mater Res B Appl Biomater 101(7):1209–1216. doi:10.​1002/​jbm.​b.​32932 CrossRefPubMed
Metadaten
Titel
Long-term behavior of double crown retained dentures with metal and metal-free secondary crowns and frameworks made of Vectris© on all-ceramic primary crowns: a prospective, randomized clinical trial up to 14 years
verfasst von
T. Zahn
B. Zahn
S. Janko
P. Weigl
S. Gerhardt-Szép
H. C. Lauer
Publikationsdatum
23.09.2015
Verlag
Springer Berlin Heidelberg
Erschienen in
Clinical Oral Investigations / Ausgabe 5/2016
Print ISSN: 1432-6981
Elektronische ISSN: 1436-3771
DOI
https://doi.org/10.1007/s00784-015-1597-y

Weitere Artikel der Ausgabe 5/2016

Clinical Oral Investigations 5/2016 Zur Ausgabe

Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.