Skip to main content
Erschienen in:

Open Access 01.12.2023 | Review

Long-term treatment outcomes with zygomatic implants: a systematic review and meta-analysis

verfasst von: Matthew Brennand Roper, Arjan Vissink, Tom Dudding, Alex Pollard, Barzi Gareb, Chantal Malevez, Thomas Balshi, Lawrence Brecht, Vinay Kumar, Yiqun Wu, Ronald Jung

Erschienen in: International Journal of Implant Dentistry | Ausgabe 1/2023

Abstract

Purpose

The purpose of this study was to perform a systematic review with meta-analysis on the long-term survival rates of zygomatic implants (ZI). ZI success, prostheses survival and success, sinus pathology and patient reported outcomes were also investigated.

Methods

Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines were followed. Embase and OvidMedline databases were searched alongside the grey literature. The systematic review was recorded in PROSPERO (CRD42022358024). Studies reporting titanium/titanium alloy ZI survival data, ZI-supported prosthesis data, ZIs directly compared to any other implant therapy including grafted sites, a minimum follow-up time of 3 years and a minimum number of 10 patients were included. All study designs were considered if they met the inclusion criteria. Studies not involving ZIs, ZIs not made from titanium/titanium alloy, a follow-up time of < 3 years or < 10 patients, animal studies and in vitro studies were excluded. Long-term follow-up has not been defined in the literature. A minimum of 3 years follow-up was considered acceptable to capture survival after initial healing, alongside in-function prosthesis data via delayed or immediate load protocols. ZI success, was predominantly defined as ZI survival without biological or neurological complications. Meta-analyses were performed for ZI survival, ZI failure incidence, ZI success, loading protocol, prosthesis survival, and prevalence of sinusitis using random effects models. Descriptive analysis was used for ZI success, prosthesis success and patient reported outcome measures.

Results

Five hundred and seventy-four titles were identified, of which 18 met the inclusion criteria. Eligible studies included 1349 ZIs in 623 patients. Mean follow-up period was 75.4 months (range 36–141.6). The mean survival of ZIs was 96.2% [95% CI: 93.8; 97.7] at 6 years. Mean survival for delayed loading was 95% [95% CI: 91.7; 97.1] and 98.1% [95% CI: 96.2; 99.0] for immediate loading (p = 0.03). Annual incidence rate of ZI failure was 0.7% [95% CI 0.4; 1.0]. Mean ZI success was 95.7% [95% CI 87.8; 98.6]. Mean prosthesis survival was 94% [95% CI 88.6; 96.9]. Sinusitis prevalence was 14.2% [95% CI 8.8; 22.0] at 5 years. Patients’ reported increased satisfaction with ZIs.

Conclusions

ZIs have long-term survival comparable to conventional implants. Immediate loading showed a statistically significant increase in survival over delayed loading. Prosthesis survival was similar to that of prostheses supported by conventional implants, with similar complications. Sinusitis was the most frequently encountered biological complication. Patients reported improved outcome measures with ZI use.

Graphical Abstract

Hinweise

Supplementary Information

The online version contains supplementary material available at https://​doi.​org/​10.​1186/​s40729-023-00479-x.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Abkürzungen
ZI
Zygomatic implant
PROM
Patient reported outcome measures
PRISMA
Preferred Reporting Items for Systematic Review and Meta-Analyses
PROSPERO
Prospective Register of Systematic Reviews
PIO
Patient, intervention, outcome
OHIP
Oral health impact profile
OHIP EDENT
Oral health impact profile edentulous
QoL
Quality of life
CI
Confidence interval
ZAGA
Zygoma anatomy guided approach
ORIS
Offset, rhino-sinus, infection, stability
NR
Not reported
N
Number

Introduction

Implant-supported rehabilitation of the maxilla represents a significant surgical challenge when bone volumes are inadequate to allow placement of conventional implants with various treatment modalities explored [1]. Patients face the likelihood of protracted treatment times with significant morbidity related to donor harvest sites, and the additional costs related to the use of biomaterials. Prosthodontic rehabilitation may also be delayed, as two-stage procedures are required if primary stability is not achieved, or when hard tissue reconstruction is required prior to implant placement. These challenges may act as barriers to the provision of care, which may otherwise improve the quality of patients’ lives.
The use of the zygoma as an anchorage site was first explored by Branemark in 1988, using customised, increased-length conventional implants. This technique was first reported in the literature by Aparicio [2], when stabilising a graft in the pre-maxilla using the zygomatic process of the maxilla for anchorage. These implants may present an opportunity to bypass the conventional route of hard tissue regeneration, as well as to reduce treatment time frames [3]. Zygomatic implant (ZI) designs are also evolving to meet increased demand in the face of an expanding range of clinical indications, such as oncologic resections or trauma, with key roles including the retention of obturators or in combination with free flap reconstructions [4].
Treatment modalities include ZIs splinted to conventional implants in the anterior maxilla; or the use of a quad zygoma approach [5] for fixed or removable reconstructions, initial prosthetic rehabilitation followed a two-stage approach, but immediate loading has been identified as a viable treatment modality too [6, 7], with some studies reporting this as the preferred protocol in terms of survival outcomes. The anterior–posterior (AP) spread for prosthetic reconstruction can also improved in the case of significantly pneumatised sinuses extending into the canine region, when options are limited for tilted implants [8]. The ability to deliver implants without the conventional challenges as described above, alongside immediate loading, presented a significant step forwards in terms of patient experience and expediency of care in compromised clinical situations. ZIs appear to show good survival rates in the short to medium term [9], however, complications include sinus pathology and oro-antral communications [10, 11]. Prostheses supported by ZIs also appear to show high survival in the short [12] and medium term [13]. There is little data on the long-term survival and success of the prosthetic reconstructions supported by ZIs, or on patient reported outcomes. Therefore, the aim of this systematic review was to assess long-term ZI survival rates, and to report on biological, prosthetic, mechanical and patient reported outcomes (PROMS) based on previously published clinical studies. The null hypothesis was no difference in the prevalence of ZI survival, or the prevalence and complications related to ZI-supported reconstructions, when compared to conventional implants and their reconstructions in the maxilla.

Methods

Preferred Reporting Items for Systematic Review and Meta-Analyses (PRISMA) guidelines were followed for this review. The systematic review was recorded in the International Prospective Register of Systematic Reviews (PROSPERO) under registration number CRD42022358024.

Eligibility criteria

Inclusion criteria were formulated using the PIO format. The population (P) included adults over the age of 18, who had received titanium/titanium alloy ZIs. The intervention (I) was the use of restored and unrestored ZIs. The outcome (O) was ZI survival with secondary outcomes including ZI success, prosthetic survival and success, prosthetic complications, sinus pathology and patient reported outcomes over a minimum of 3 years follow-up.

Inclusion criteria

Clinical studies which met the following inclusion criteria were included: Studies including ZIs, studies including ZI-supported fixed or removable reconstructions, ZIs made from titanium/titanium alloy, studies directly comparing ZIs to any other conventional implant therapy (included grafted sites), a minimum follow-up time of 3 years and a minimum number of 10 patients. Study designs included were randomised controlled trials, clinical trials, prospective case series and retrospective case series.

Exclusion criteria

The exclusion criteria were clinical studies that did not involve ZIs, ZIs not made from titanium/titanium alloy, a follow-up time of less than 3 years, or with less than 10 patients included. Animal studies and in vitro studies were excluded.

Study identification

Studies were extracted from Embase, dating 1974 to June 21, 2022 and from Ovid MEDLINE dating 1946 to June 21 2022. The full search strategy table is tabulated in Additional file 1: Table S1. The search was not limited by language.

Outcome measures

ZI survival (presence or absent at follow-up) was the primary outcome measure. Secondary outcomes included ZI success, ZI-supported prosthesis survival, success and complications, sinus pathology and patient reported outcomes. Heterogeneity was noted in the reporting of ZI success, which was predominantly defined as ZI survival without biological or neurological complications across the studies.

Data extraction

Data were independently extracted and assessed by two reviewers (MBR and TD). Collection included authors, year of publication, patient data, outcomes reported, loading protocols and follow-up periods. Outcomes recorded were ZI survival, ZI success, ZI-supported prosthesis survival and/or success, sinus data and PROMs. Study authors were contacted in the event of missing data and the report excluded in the event of no reply or inadequate data.

Risk of bias assessment

The papers included were case series reports. Therefore, the critical appraisal checklist for case series, developed by the Joanna Briggs Institute (critical appraisal tools for use in systematic reviews, 2017) was used to assess the risk of bias. This checklist identified the completeness of the report, risk of bias, and the accuracy of reporting. Reports were independently assessed by two reviewers (MBR and AP) with conflicting outcomes resolved by discussion with a third reviewer (TD).

Statistical analysis

Effect measures were generated for ZI survival prevalence (%), ZI failure incidence rate (%/year), ZI success prevalence (%), prosthesis survival prevalence (%), and sinusitis prevalence (%). ZI failure incidence rate was calculated as the total annual failure incidence rate over the complete follow-up (%/year), failure incidence in the first year (%), and annual failure incidence after the first year of follow-up (%). In addition, an a priori specified subgroup analysis comparing the ZI survival (%) between the different loading protocols (immediate versus delayed) was performed. Statistical heterogeneity was assessed as substantial if I2 was > 50% [14]. All meta-analyses were performed in R (v4.2.2, meta-package) using a random effects model with the DerSimonian–Laird estimator. Reporting bias was assessed through funnel plots if > 10 studies were available per endpoint if no clinical or statistical heterogeneity was observed. In all analyses, p < 0.05 (two-tailed) was considered statistically significant.

Results

Selection process

An initial screening of 574 titles and abstracts was carried out by the main author (MBR) (Fig. 1). The grey literature search identified 5 studies. 55 papers were subsequently sought for retrieval. Full-text articles were not retrieved for 5 reports leaving 50 reports to be assessed for eligibility.
These reports were independently reviewed according to the inclusion and exclusion criteria by two reviewers (MBR and TD). The studies included, along with the extracted data, are presented in Table 1, whilst patient demographics are presented in Table 2.
Table 1
Datasets extracted from the included studies (n = 18)
Study
Year of publication
Number of patients
Mean follow-up (months)
Outcomes reported
Loading protocol
Study type
Zygomatic implant number
Female
Mean age
Age range
Smokers
Kahnberg et al. 2007
2007
76
36
Survival
Prosthesis success
Sinus data
PROM
Delayed
Prospective Case Series
145
57
58
35–77
15
Pellegrino et al. 2020
2020
20
39.9
Survival
Success
Prosthesis survival
Prosthesis success
PROM
Immediate
Prospective Case Series
73
NR
56.7
 ± 12.6
9
Aparicio et al. 2014
2014
80
55.44
Survival
Sinus data
PROM
Delayed
Retrospective Case Series
157
55
3.81
42.78–64.78
24
Coppede et al. 2017
2017
42
60
Survival
Immediate and delayed
Prospective Case Series
94
32
58
37–79
8
Davo and Pons 2015
2015
14
60
Survival
Success
Prosthesis survival
Sinus data
PROM
Immediate
Prospective Case Series
68
10
57.7
41–78
NR
Malo et al. 2014
2014
39
60
Survival
Success
Prosthesis survival
Sinus data
PROM
Immediate
Retrospective Case Series
92
30
53.5
32–77
4
Davo, Malevez and Pons 2013
2013
36
60
Survival
Success
Prosthesis success
Sinus data
Immediate
Prospective Case Series
69
23
57.5
34–79
NR
Davo 2009
2009
21
60
Survival
Prosthesis success
Sinus data
Delayed
Retrospective Case Series
39
16
51.4
36–72
NR
Branemark et al. 2004
2004
28
60
Survival
Prosthesis survival
Sinus data
Delayed
Prospective Case Series
52
16
58.3
39–79
NR
Yates et al. 2013
2013
23
72
Survival
Success
Delayed
Retrospective Case Series
43
13
NR
NR
6
Bedrossian E. 2010
2010
36
84
Survival
Immediate
Prospective Case Series
74
22
NR
NR
NR
Agliardi et al. 2017
2017
15
85.04
Survival
Success
Prosthesis success
Sinus data
PROM
Immediate
Prospective Case Series
42
13
62
46–70
NR
Chana et al. 2019
2019
45
90
Survival
Prosthesis survival
Sinus data
Immediate and delayed
Retrospective Case Series
88
23
56.27
 ± 13
14
Miglioranca et al. 2012
2012
21
96
Survival
Prosthesis survival
Immediate
Prospective Case Series
40
13
55
 ± 6.66
14
Fortin 2017
2017
58
100.8
Survival
Success
Immediate and delayed
Retrospective Case Series
107
40
65.3
 ± 8
NR
Bothur et al. 2015
2015
14
111.6
Survival
Prosthesis survival
Delayed
Prospective Case Series
58
9
60
51–78
3
Aparicio et al. 2014
2014
22
120
Survival
Prosthesis survival
Sinus data
PROM
Delayed
Prospective Case Series
41
14
63.10
48–80
5
Di Cosola et al. 2021
2021
33
141.6
Survival
Success
Sinus data
Immediate and delayed
Retrospective case series
67
17
59.1
NR
7
Table 2
Included studies and characteristics (n = 18)
Study
Study type
Zygomatic implant number
Female
Mean age
Age range
Smokers
Kahnberg et al. 2007
Prospective case series
145
57
58
35–77
15
Pellegrino et al. 2020
Prospective case series
73
NR
56.7
 ± 12.55
9
Aparicio et al. 2014
Retrospective case series
157
55
3.81
42.78–64.78
24
Coppede et al. 2017
Prospective case series
94
32
58
37–79
8
Davo and Pons 2015
Prospective case series
68
10
57.7
41–78
NR
Malo et al. 2014
Retrospective case series
92
30
53.5
32–77
4
Davo, Malevez and Pons 2013
Prospective case series
69
23
57.5
34–79
NR
Davo 2009
Retrospective case series
39
16
51.4
36–72
NR
Branemark et al. 2004
Prospective case series
52
16
58.3
39–79
NR
Yates et al. 2013
Retrospective case series
43
13
NR
NR
6
Bedrossian 2010
Prospective case series
74
22
NR
NR
NR
Agliardi et al. 2017
Prospective case series
42
13
62
46–70
NR
Chana et al. 2019
Retrospective case series
88
23
56.27
 ± 12.95
14
Miglioranca et al. 2012
Prospective case series
40
13
55
 ± 6.66
14
Fortin 2017
Retrospective case series
107
40
65.3
 ± 8
NR
Bothur et al. 2015
Prospective case series
58
9
60
51–78
3
Aparicio et al. 2014
Prospective case series
41
14
63.10
48–80
5
Di Cosola et al. 2021
Retrospective case series
67
17
59.1
NR
7
NR not reported
Excluded studies and the reasons for exclusion are presented in Additional file 1: Table S2.

Zygomatic implant survival

Survival description across studies

Eligible studies included a total of 1349 ZIs placed in 623 patients. Survival was determined by the presence or absence of a ZI at completion of the study. The mean follow-up period across all studies was 75.4 months (6.3 years) with a follow-up range of 36 to 141.6 months (3 years–11.8 years). Table 3 reports the ZI survival dataset.
Table 3
Zygomatic implant survival dataset
Study
Patient number
Zygomatic implant number
Number of failed implants
Number of patients failure in
Survival
Follow-up
Mean (months)
Follow-up range (months)
Kahnberg et al. 2007
76
145
5 (3.45%)
4 (5.26%)
96.5
36
N/A
Pellegrino et al. 2020
20
73
2 (2.75%)
2 (10%)
97.3
39.9
 ± 19.5
Aparicio et al. 2014
80
157
5 (3.18%)
2 (2.5%)
96.8
55.4
 ± 234.7
Coppede et al. 2017
42
94
1 (1.06%)
1 (2.38%)
98.9
60
N/A
Davo and Pons 2015
14
68
0 (0.00%)
0 (0.00%)
100
60
N/A
Malo et al. 2014
39
92
1 (1.09%)
1 (2.56%)
98.9
60
N/A
Davo, Malevez and Pons 2013
36
69
1 (1.45%)
1 (2.78%)
98.6
60
N/A
Davo 2009
21
39
1 (2.56%)
1 (4.76%)
97.4
60
N/A
Branemark et al. 2004
28
52
3 (5.77%)
3 (10.71%)
94.2
60
60–120
Yates et al. 2013
23
43
6 (13.95%)
6 (26.09%)
86.1
72
48–72
Bedrossian 2010
36
74
2 (2.70%)
2 (5.56%)
97.3
84
− 84
Agliardi et al. 2017
15
42
0 (0.00%)
0 (0.00%)
100
85
73–91
Chana et al. 2019
45
88
5 (5.69%)
3 (6.66%)
94.3
90
Not reported
Miglioranca et al. 2012
21
40
1 (2.50%)
1 (4.76%)
97.5
96
Not reported
Fortin 2017
58
107
0 (0.00%)
0 (0.00%)
100
101
60–156
Bothur et al. 2015
14
58
2 (3.45%)
1 (7.14%)
96.6
112
69.6–144
Aparicio et al. 2014
22
41
2 (4.88%)
1 (4.55%)
95.1
120
 ± 154.1
Di Cosola et al. 2021
33
67
16 (23.88%)
8 (24.24%)
76.1
142
109–198
The mean survival at 75.4 months was 96.2% [95% CI 93.8; 97.7] (Fig. 2). The lowest survival was 76.1% [95% CI 64.1; 85.7] survival at 141.6 months [30], whilst 3 studies reported 100% survival at 60, 85, and 101 months, respectively [13, 18, 27].
When comparing studies with immediate loading to delayed (Fig. 3), mean survival prevalences for delayed load protocols were 95% [95% CI 91.7; 97.1] over a mean of 69.3 months follow-up, and 98.1% [95% CI 96.2; 99.0] over a mean of 73.6 months follow-up for immediate loading protocols (p = 0.03).

Incidence of zygomatic implant failure

Zygomatic implant failure was defined as the antagonist of ZI survival. The total annual incidence of ZI failure across the studies was 0.7%/year [95% CI 0.4; 1.0] (Fig. 4).
The incidence of ZI failure within the first year was 2% [95% CI 1.1; 3.7] following placement (Fig. 5), whilst the incidence of ZI failure after the first year following placement was 0.5%/year [95% CI 0.3; 0.7] (Fig. 6)
A significant relationship between implant failure and gender was reported by one study, Di Cosola et al. [30] (males compared with females (p < 0.05). No other evaluated conditions (age, smoking, hypertension, or diabetes) were correlated with failure. No statistically significant association between implant failure and sex, surface finish, implant length, or position (p > 0.05) [25]. No other studies identified relationships between implant failure and patient demographic.
The classification of ZI placement across the studies was split between the classical Branemark approach (intrasinus), the extra-sinus classification as reported by Miglioranca [26], and the zygomatic anatomy guided approach (ZAGA) developed by Carlos Aparicio [31]. Within this systematic review, no relationship was identified between approaches and survival rates.
Table 4 documents reasons for ZI loss where reported.
Table 4
ZI loss reported across studies
Reason attributed to ZI loss
Total number of lost ZIs
Total number of ZIs combined in studies
Study
Sinusitis
19 (12.25%)
155
Di Cosola et al., Chana et al.
Oro-antral communication
1 (1.09%)
92
Malo et al.
Failure of osseointegration
5 (2.34%)
214
Chana et al., Bedrossian et al., Brannemark et al.
Loss of osseointegration
11 (2.39%)
461
Coppede et al., Bothur et al., Yates et al., Davo, Malevez and Pons, kahnberg et al., Branemark et al., Aparicio et al.
Infection or peri-implantitis
4 (3.10%)
129
Yates et al., Aparicio et al.
Pain
3 (2.36%)
127
Chana et al., Davo
Incorrect position
1 (2.32%)
43
Yates et al.
Zygomatic implant fracture
1 (0.64%)
157
Aparicio et al.
Unreported reasons for failure
8 (3.37%)
237
Fortin, Pellegrino et al., Davo and Pons, Agliardi et al.

Zygomatic implant success

The mean ZI success was 95.7% [95% CI 87.8; 98.6] (Fig. 7) over a mean follow-up of 71.5 months. ZI success was predominantly defined as ZI survival without biological or neurological complications. Success ranged from 46.3% [95% CI 34.0; 58.9] [30] to 100% [95% CI 91.6; 100] [13]. Failure to meet success criteria included unfavourable positioning [18], peri-implant mucositis [16], bleeding on probing and increased pocket depths [19, 25], recession and extra-oral Infective processes [16, 27].
Table 5 reports ZI success data and reasons for failure to meet success criteria across the studies.
Table 5
Zygomatic implant success report
Study
Zygomatic implant number
Success
Failure to meet success
Patient number
Follow-up
Follow-up range
Pellegrino et al.a 2020
Atrophic
Oncologic
38
35
89.8% (CI: 60.4–97.7%) (n = 34)
96.7% (CI:79.2–99.5%) (n = 34)
Mucositis: 13.1% (3.7–41%)
Mucositis: 39.7% (9.7–91.7%)
Extra-oral swelling (n = 1)
10
10
39.9
 ± 19.5
Davo and Pons 2015
68
98.5% (n = 67)
Unfavourable position (n = 1)
14
60
N/A
Malo et al. 2014
92
98.8% (n = 91)
PPD > 4 mm (n = 23)
39
60
N/A
Davo, Malevez and Pons. 2013
69
98.55% (n = 68)
NR
42
60
N/A
Yates et al. 2013
43
86.05% (n = 37)
Recession of 2–4 threads (n = 6)
25
72
48–72
Agliardi et al. 2017
42
100% (n = 42)
NR
15
85
73–91
Miglioranca et al. 2012
40
97.5% (n = 39)
NR
21
96
Not reported
Fortin 2017
107
100% (n = 107)
Successful treatment of infection by implant apicoectomy. (not included in success data by study)
58
100.8
60–156
Cosola et al. 2021
67
46.3% (n = 36)
28 ZI (41.8%) experienced infective complications defined as sinusitis, oro-antral fistula or soft tissue infection. Early neurologic pain following treatment in 8 ZI (11.9%) in 5 patients
33
141.6
109–198
NR not reported
aReported as two groups in the same study

Zygomatic implant-supported prostheses: survival and success

The mean prosthesis survival was 94% [95% CI 88.6; 96.9] at 76 months of mean follow-up (Fig. 8). Seven studies conducted an immediate load protocol, with an interim prosthesis placed immediately after surgery, and was replaced after 3–6 months with the permanent prosthesis. Four conducted both immediate and delayed protocols and 7 conducted delayed protocols.
Table 6 reports prosthesis survival and success data. Survival was determined by the presence or absence of the permanent reconstruction at time of study completion. Success criteria varied across the reports. The main subgroups for failure to meet success included prosthetic tooth loss, chipping or fracture of the veneering material, abutment or screw fracture and abutment or screw loosening.
Table 6
Prosthesis survival and success data
Study
Prosthesis number
Prosthesis survival
Prosthesis success
Success criteria
Prosthesis fracture
Prosthetic tooth loss
Screw/abutment loosening/fracture
Follow-up
Kahnberg et al. 2007
60
 
83.34% (n = 50)
Clinically stable prosthesis that not been removed for two weeks or more during the study period
 
2 cases requiring laboratory repair
1 patient with loosening of ball attachments
36
Pellegrino et al. 2020
20
100% (n = 20)
90% (n = 9)
(95% CI: 47.3–98.5%) Atrophic
58.3% (n = 6)
(95% CI: 22.9–82%) Oncologic
difference between the groups was not statistically significant (p = 0.77)
Support of all placed implants, extended to the first molar region, not need to be reduced from the day of delivery to the final follow-up
  
Prosthetic screw loosening and abutment fractures. All unsuccessful prosthetic events occurred in the first year, with the majority experienced by the oncologic group. 5-year follow-up complication probability values were 10.7% [95% CI 4.1–26%] for the atrophic group, and 10.7% [95% CI 3.5–29.6%] for the oncologic group
39.9
Aparicio et al. 2014
80
NR
NR
NR
65 events involving fracture of the prosthetic acrylic coating material occurred. 2 fractures of the porcelain coating occurred. No metal framework fractures
NR
16 screws and abutments loosened within the ZAGA group, and 7 screws fractured
55.44
Davo and Pons 2015
14
100% (n = 14)
 
Clinically stable prosthesis that not been removed for two weeks or more during the study period
1 incidence of acrylic fracture from the underlying substructure at 36 months
1 incident involving loss of an anterior tooth from an acrylic prothesis
Fracture of 1 abutment at 12 months
60
Coppede et al. 2017
42
NR
NR
NR
NR
Fractures or detachments in 5 fixed implant-supported restorations (14.7%)
NR
60
Malo et al. 2014
39
100% (n = 39)
NR
NR
3 prostheses fracturing in 3 patients. 2 acrylic prostheses fractured at 48 and 58 months of follow-up, whilst a metal ceramic prosthesis fractured at 49 months
NR
Abutment screw loosening occurred in 1 patient at 54 months and prosthetic screw loosening in 2 patients at 47 and 55 months
60
Davo, Malevez and Pons 2013
36
NR
97.2% (n = 35
Clinically stable prosthesis that not been removed for two weeks or more during the study period
NR
Replacement of resin teeth in 4 definitive acrylic fixed prostheses after 4 years of function due to extreme tooth wear
NR
60
Branemark et al. 2004
28
82% (n = 23)
 
NR
NR
NR
NR
60
Davo 2009
21
NR
95.8% (n = 20)
Clinically stable prosthesis that not been removed for two weeks or more during the study period
NR
NR
NR
60
Agliardi et al. 2017
83
NR
100% (n = 83)
In function without mobility or pain, even if one or more of the implants were lost
NR
NR
NR
85.1
Chana et al. 2019
88
93.98% (n = 82)
NR
NR
Failure only in the fixed prosthetic group, when compared to the removable prosthetic group (n = 5/56 and n = 0/27, respectively). Failure was related to 1 fixed acrylic bar and 4 metal acrylic fixed prostheses
NR
Reported loosening in 7 abutments. 1 patient experienced abutment loosening twice within a 12-month period
90
Miglioranca et al. 2012
21
95.2% (n = 20)
NR
NR
Fracture of the metal bar supporting a prosthesis in 1 patient
NR
NR
96
Fortin Y. 2017
58
100% (n = 58)
NR
NR
NR
NR
NR
100.8
Bothur et al. 2015
14
92.9% (n = 13)
NR
NR
NR
NR
Reported loosening of 2 angled abutments and a third with a damaged thread
111.6
Aparicio et al. 2014
22
95.5% (n = 21)
 
NR
4 incidents of fracture of the acrylic coating material, 25 fractures of the porcelain coating material, and fracture of 2 metal frameworks
 
Reported 6 episodes of screw fractures and 9 episodes of screw or abutment loosening
120

Sinus pathology

Sinusitis

Sinusitis was reported by 11 studies with a total prevalence of 14.2% [95% CI 8.8; 22.0] over a mean of 65.4 months follow-up (Fig. 9). The prevalence of sinusitis ranged from 2.8% [95% CI 0.1;14.5] at 60 months mean follow-up [20], to 36.4% [95% CI 20.4; 54.9] at 141.6 months of mean follow-up [30]. Disease was diagnosed clinically, radiographically, using patient reported questionnaires, or combined methods [11]. Sinusitis was the most commonly reported factor related to implant loss.
Table 7 reports the data involving the sinus within the studies.
Table 7
Reported sinus pathology
Study
Mean follow-up
% of patients experiencing sinusitis during follow-up
Individual patient level timeframe data
Presence of oro-antral communication/fistula during follow-up
Intra or extra-sinus zygomatic implant path
Zygomatic implant loss related to sinusitis
Management
Previous history of sinusitis
Kahnberg et al. 2007
36
18.4% (n = 14)
Not reported
3.9% (n = 3)
Path involving the sinus
Not reported
Not reported
Not reported
Aparicio et al. 2014
55.24
3.7% (n = 3)
Not reported
2.5% (n = 2)
Path involving the sinus
Not reported
Not reported
Not reported
Malo et al. 2014
60
13% (n = 5)
Sinusitis diagnosed in 2 patients at 2 months then individual patients at 6, 12 and 24 months, respectively
1.08% (n = 1)
Extra-maxillary approach
1.08% (n = 1) in 2.6% (n = 1) patient
Antibiotics for 2 patients and surgical management for 2 successful for 4 of 5 patients
13% (n = 5) patients
Davo, Malevez and Pons 2013
60
1.7% (n = 1)
Not reported
Sinusitis (n = 1)
Pain and swelling at zygomatic level (n = 1)
Intra and extra-maxillary paths
Not reported
Antibiotics and meatotomy successful
Not reported
Davo 2009
60
23.8% (n = 5)
Not reported
Not reported
Path involving the sinus
No failures due to sinusitis
2 patients Antibiotics, 2 patients meatotomy or 1 patient Caldwell Luc. All successful treatments
Not reported
Branemark et al. 2004
60
14.2% (n = 4)
Not reported
Not reported
Path involving the sinus
Not reported
Meatotomy on 4 patients
3.5% (n = 1) patient
Davo and Pons 2015
60
14% (n = 2)
Sinus infection diagnosed at 24 and 30 months, respectively
Fistula at 1 implant
Path involving the sinus
Not reported
Antimicrobial therapy successful in managing disease
Not reported
Chana et al. 2019
90
6.6% (n = 3)
Not reported
Not reported
Intra and extra-maxillary paths
3.4% (n = 3) in 6.6% (n = 3) patients
Not reported
Not reported
Agliardi et al. 2017
85.04
6.7% (n = 1)
5 months after placement
6.7% (n = 1)
Path involving the sinus
0% (n = 0)
Antimicrobial therapy successful in managing disease
Not reported
Aparicio et al. 2014
120
27.3% (n = 6)
Post placement, 1–2 years, 2–3 years, 7–8, 8–9, 10–11
3.75% (n = 80)
Path involving the sinus
1.5% (n = 2) in 4.5% (n = 1) patient
5 patients successfully managed with antimicrobials
Not reported
Cosola et al. 2021
141.6
32.8% (n = 12)
Not reported
Not reported
70.2% (n = 47) completely intrasinusal. 29.85% (n = 20) not completely intrasinusal
23.9% (n = 16) in 24.24% (n = 8) patients
Not reported
Not reported

Oral health impact of zygomatic implant therapy

Patient reported outcomes using the Oral Health Impact 14 score (OHIP14) were reported by Pellegrino et al. [16] and Davo and Pons [18]. Pellegrino et al. [16] reported OHIP scores of 30.4 (± 9.5) pre-operative and 6.3 (± 3.7) after 60 months follow-up. Davo and Pons [18] reported total mean OHIP14 scores of 3.4, 2.5, 3.8 at 1, 2 and 5 year follow-up recalls, respectively. No pre-operative OHIP14 questionnaires were carried out.
Oral Health Impact Profile Edentulous questionnaires (OHIP EDENT) were reported for 22 patients within a control group (Classical Branemark approach) [29]. 84% reported satisfaction scores above 80%. 31.8% of those patients reporting a maximum satisfaction score of 100%. This control group was compared against a test group (ZAGA approach), of which 76.3% (n = 61) recorded satisfaction rates of between 81 and 100% [11]. The difference between the groups was not statistically significant (P = 0.92).
A Likert scale to investigate satisfaction following a full-arch, immediate restoration supported by ZIs, was reported by Agliardi et al. [13]. Aesthetics and function were reported as excellent or very good by the entire group of 15 patients. Phonetics was considered excellent or very good by 13 of 15 patients.
Subjective satisfaction for oral rehabilitation using ZIs and prosthetic reconstructions were reported by Kahnberg et al. [15]. 73 Patients reported 86% satisfaction with the aesthetics and 71% satisfaction with the functional outcomes at 3 years of follow-up.
Malo et al. [19] assessed aesthetic and functional complaints in a group of 39 patients over a 5-year period. There were no reports of complaints at the final follow-up by any patients.

Assessment of bias

The risk of bias assessment is summarised in Table 8. Consecutive inclusion of participants and complete inclusion of participants presented the most common risk of bias, as this was unclear in several studies. Older studies reported data in a less systematic fashion when compared to contemporary studies. Descriptive analysis was the most common reporting methodology.
Table 8
Assessment of studies using the Joanna Briggs Institute critical appraisal tools for case series
Study
Was there clear criteria for inclusion?
Was the condition measured in a standard, reliable way for all participants?
Were valid methods used for identification of the condition for all participants included in the case series
Did the case series have consecutive inclusion of the participants
Did the case series have complete inclusion of participants
Was there clear reporting of the demographics of the participants in the study
Was the clear reporting of clinical information of the participants
With the outcomes or follow-up results of cases clearly reported
Was there clear reporting of the presenting site/clinic demographic information
Was statistical analysis appropriate
Kahnberg et al. 2007
Unclear
Unclear
Unclear
Unclear
Unclear
Unclear
Yes
Yes
Yes
Not applicable
Pellegrino et al. 2020
Yes
Yes
Yes
Unclear
Unclear
Yes
Yes
Yes
Unclear
Yes
Aparicio et al. 2014
Unclear
Yes
Unclear
Yes
Unclear
Yes
Yes
Yes
Yes
Not applicable
Coppede et al. 2017
Yes
Yes
Yes
Unclear
Unclear
Yes
Yes
Yes
Yes
Not applicable
Davo & Pons. 2015
Yes
Yes
Yes
Yes
Yes
Unclear
Yes
Yes
No
Not applicable
Malo et al. 2014
Yes
Yes
Yes
Unclear
Unclear
Yes
Yes
Yes
Yes
Not applicable
Davo, Malevez and Pons 2013
Yes
Yes
Yes
Yes
Unclear
Unclear
Yes
Yes
Yes
Not applicable
Davo 2009
Yes
Yes
Unclear
Yes
Unclear
Unclear
Yes
Yes
Yes
Not applicable
Branemark et al. 2004
Unclear
Unclear
Unclear
Yes
Unclear
Yes
Yes
Yes
Yes
Not applicable
Yates et al. 2013
Yes
Yes
Yes
Unclear
Yes
Unclear
Yes
Yes
Yes
Yes
Bedrossian 2010
Yes
Yes
Yes
No
No
No
Unclear
Yes
No
Not applicable
Agliardi et al. 2017
Yes
Yes
Yes
Yes
Unclear
Yes
Yes
Yes
Yes
Not applicable
Chana et al. 2019
Yes
Yes
Yes
Unclear
Yes
Yes
Yes
Yes
Yes
Not applicable
Miglioranca et al. 2012
Yes
Yes
Yes
Unclear
Unclear
Yes
Yes
Yes
Yes
Not applicable
Fortin 2017
Unclear
Yes
Yes
Yes
Unclear
Unclear
Yes
Yes
Yes
Not applicable
Bothur et al. 2015
Unclear
Yes
Yes
Unclear
Unclear
Yes
Yes
Yes
Yes
Not applicable
Aparicio et al. 2014
Yes
Yes
Yes
Yes
Unclear
Yes
Yes
Yes
Yes
Yes
Cosola et al. 2021
Yes
Yes
Yes
Unclear
Unclear
Yes
Yes
Yes
Yes
Yes

Discussion

ZIs present a therapeutic opportunity to rehabilitate patients who lack either the desire to undergo extensive augmentation procedures, or lack the anatomical structures required, to deliver conventional implant therapy in the maxilla. Custom, increased-length, end osseous implants anchored in the zygomatic process was first reported by Aparicio et al. in 1993 [2], with subsequent international studies exploring this treatment modality and its outcomes. The present systematic review focused on long-term ZI survival (≥ 3 years). Unfortunately no controlled trials, randomised or otherwise, that met our criteria were identified. Severe maxillary atrophy was the predominant clinical indication, and described patients who were unable to receive conventional implants without additional augmentation procedures. Other clinical indications for ZIs included trauma, cleft, and oncologic patient groups. There was a paucity of studies meeting the inclusion criteria for ZI placement in oncology patients. This could be related to the reduced survival rates of such individuals, alongside the increased risk of osteoradionecrosis (ORN) for those who received adjuvant radiotherapy to the zygomatic region. Only one study within this systematic review [16] compared ZI survival in the atrophic maxilla against ZIs placed after oncologic resections, and identified no difference in survival between the groups.

Zygomatic implant survival

In this review, ZI survival was 96.2% [95% CI 93.8; 97.7] over the mean follow-up of 75.4 months (6.3 years). The results are consistent with two other systematic reviews. The first included 68 studies [32], which reported a cumulative survival rate of 95.2% with no minimum follow-up, to a maximum follow-up of 12 years. The second, Sola Perez et al. [33] reported survival rates of 98.5% within the first year, 97.5% between 1 and 3 years, 96.8% at 3–5 years and 96.1% at more than 5 years. The current study also investigated the overall incidence of ZI failure (failure being defined as the antagonist of ZI survival), incidence of failure within the first year, and incidence of failure in subsequent years. When ZI failure did occur, sinusitis, oro-antral communications, failure of osseointegration, loss of osseointegration, infection or peri-implantitis, pain and zygomatic implant fracture were the related factors in descending order of frequency. A higher incidence of failure was identified within the first year (2%) compared to that of subsequent years (0.5%/year), whilst the overall annual failure incidence was 0.7% with intra-study mean follow-up times ranging from 36 to 142 months, again corroborated by the systematic review from Chrcanovic et al. [34], and Chrcanovic et al. [32]. These findings reflect the possibility that some patients will suffer from early infective, or medically related, post-surgical complications, which may result in ZI loss.
We found the mean ZI survival rate to be higher for immediate Loading protocols over delayed loading protocols. Di Cosola et al. [30] reported that immediate loading resulted in significantly lower risk of infective, neurological and overall complications compared with the two-step rehabilitation. The latter finding was supported by Chrcanovic et al. [32], who hypothesised this to be related to the length of follow-up, as delayed loading protocols were associated with increased time frames allowing greater chance of failure to occur during this period. The slightly higher ZI survival rate could also be due to evolution in the delivery of ZI therapy. Delayed load protocols are associated with the original technical approach, whilst immediate load protocols were introduced alongside refinements to the surgical technique, operator familiarity with the procedure, and ZI/ZI reconstruction design innovations. The difference was statistically significant between the protocols (p = 0.03) but may not be clinically relevant, and so should be interpreted with caution. Both loading protocols result in high ZI survival prevalence.
A common theme across all studies, was the combination of ZI in the posterior maxilla splinted to conventional implants in the anterior maxilla. Moraschini et al. [35], through a systematic review, compared ZI survival to conventional implant survival, which reported survival at 96.5% ± 5.0 for ZIs and 95.8% ± 6.4% for conventional implants at 78 months of mean follow-up. These findings suggest that ZIs have long-term survival rates comparable to conventional implants, with a positive inference for the ability to deliver dual implant modality supported reconstructions.
ZI survival rates also appear to be comparable to alternative techniques in the atrophic maxilla, including short implants, tilted implants, and implants placed in grafted sinuses. Slot et al. [36] reported 96.1% and 100% survival at 10 years in a randomised controlled trial of 6 or 4 conventional implants, respectively, when supporting maxillary overdentures. A meta-analysis and systematic review by Kotsovilis et al. [37] revealed no statistically significant difference in survival between short (≤ 8 mm or < 10 mm) and conventional (≥ 10 mm) rough surface implants placed in partially or totally edentulous individuals. ZIs may confer treatment time benefits to patients due to the immediacy of reconstruction when compared to implants placed in grafted sites. Further benefits are realised through reduced morbidity, due to the absence of a second donor sites, and potential cost savings due to a reduced number of procedures or number of conventional implant required to support full-arch prostheses. However, ZI placement is an advanced surgical procedure, requiring appropriate technical skillsets, and may also require sedation or a general anaesthetic, which in turn, adds additional cost and complexity to the process.

Zygomatic implant success

ZI success was 96%. Reporting ZI success demonstrated challenges because of significant heterogeneity (I2=90%) across the studies. ZIs in situ was a prerequisite, whilst specifying an absence of pain [13, 16, 17, 19, 20, 26] may have reflected reports of pain and neurosensory disturbances in the zygomaticofacial and infraorbital regions reported in other studies [21, 24, 25]. Absence of infection (included sinus disease, oro-antral communications, peri-implantitis and peri-implant mucositis) was included by 3 studies [13, 19, 23]. There are no recognised criteria for ZI success, and criteria for conventional implant success, as reported by Albrektsson and Isidor [38], have been suggested as a reference. Radiographic changes were considered as success criteria for 3 studies [13, 19, 21]. 3-dimensional imaging may provide the most accurate data on bone volume maintenance, but is unsuitable as a tool for monitoring success due to the dose of radiation received by the patient. Plain film, 2-dimensional, radiographic examinations are unsatisfactory for monitoring bone volume around ZIs, due to anatomical challenges and the possible fixture head positions in relation to the alveolar crest [39]. An attempt to standardise these reporting challenges has been suggested by Aparicio et al. [40] with the publication of the ORIS criteria (offset of prosthesis, rhino-sinusitis status, infection in soft tissue, stability of ZI) for documenting ZI success.

Zygomatic prosthesis survival and success

Prosthesis survival ranged from 82 to 100% with the mean at 94% at 76 months of follow-up. The high prosthesis survival mirrored that of ZI survival, although there was a potential for confounding as the definitive prosthesis was placed between 3 and 6 months after ZI installation. Early ZI failures could have influenced survival of the provisional prosthesis, but not the definitive reconstruction. Provisional prosthesis success was not reported in the literature, but there was little mention of complication rates as a counter argument. The mechanism of catastrophic failure was either related to loss of the supporting ZI or conventional implants, or fracture of the reconstruction [11, 18, 19, 25, 26]. Fracture of the metal substructure or fracture of the ceramic / acrylic attached to the metal substructure were the reported modes of prosthesis failure. Although not reported in this study, reconstructions supported by conventional implants alone showed no statistically significance difference between the construction materials used for full-arch screw-retained prostheses [41]. Mean ZI prosthesis survival appears comparable to full-arch screw-retained fixed prostheses supported by conventional implants. Sailer et al. [42] reported a 5-year cumulative survival of 95.8% for full-arch, screw-retained prostheses, whilst Wittneben et al. [41] reported a 5-year cumulative survival of 96.7% in comparison to this review, with 94% survival at 6 years for combined full-arch and partial ZI-supported reconstruction data.
Significant heterogeneity was found when reporting prosthesis success. Success criteria, such as allowing a prosthesis to be out of the mouth for up to 2 weeks, potentially affected the results and allowed for a higher prosthesis survival rate. In addition, Kahnberg et al. [15] and Branemark et al. [22], when faced with ZI loss, reported modification rather than replacement of the definitive prosthesis. The use of acrylic/acrylic teeth across the majority of studies potentially aided survival rates, as the prosthesis was repairable rather than lost. Chipping of the veneering resin was reported to be the second most common complication after loss of retention [41]. Technical complications for full-arch ZI screw-retained reconstructions appear to reflect those seen in conventional full-arch screw-retained implant reconstructions. Screw and abutment loosening events were frequently reported [11, 15, 16, 18, 19, 25, 28]. These complications have been reported in the implant literature [42], but adverse incidence rates for ZI reconstructions could be influenced by increased movement of the prosthesis due to bending moments of the ZIs [18, 20, 28]. These technical complications occurred regardless of whether the ZIs were splinted to conventional implants, or whether the prosthesis was supported by Quad ZIs. It is also possible that this bending phenomenon contributed to veneering material fractures away from the metal substructure. If a similarity between ZI-supported and conventional implant-supported prostheses is considered, Sailer et al.’s [42] report suggests that patient education and consent is essential in managing patients’ expectations when a 54.1% technical complication rate over 5 years exists for screw-retained, full-arch, conventional implant-supported prostheses.

Sinus pathology

The overall prevalence of sinusitis was 14.2% with a follow-up of 65.4 months. There was significant heterogeneity in the methodology employed to diagnose sinusitis across the studies, which included clinical, radiographic, patient reported questionnaires, or combined methods [11]. The 95% CI ranged from 8.8 to 22%, with an increased prevalence over longer follow-up periods [20, 30]. This finding might suggest a relationship between the two, although a reported confounding factor is the background population prevalence of chronic rhinosinusitis. This has been reported at > 10% in a western population, when measured by objective criteria [43], but when using guideline-based diagnostic criteria, the true prevalence of chronic rhinosinusitis is reportedly less than 5%.
The classical approach, or Branemark protocol [22], for ZI placement is via an intra-sinus route, with a window raised in the lateral sinus wall to allow direct visualisation for ZI placement. In contrast, the extra-sinus  approach, first reported by Miglioranca [51] does not breach the sinus cavity during placement although the extra-maxillary approach may do so at the at the most apical extent before entering the Zygoma. Extra-maxillary refers to the coronal portion of the implant at intra-oral exit site. The biological consequences of the presence or absence of a ZI within the sinus cavity are therefore worth consideration. Sinusitis was the most commonly reported factor related to ZI loss within this review. Aparicio et al. [11] reported a statistically significant difference in Lund–MacKay sinus staging score (radiographic examination) between classical and ZAGA groups (p = 0.04). Dual Lanza–Kennedy scores (patient reported) and Lund–MacKay scores, again reported a statistically significant difference between the treatment protocols. Sinus pneumatisation was found to be statistically related to overall complications and implant loss by Di Cosola et al. [30] However, these findings may relate to the fact that larger sinuses require an intra-sinus path for ZI placement, rather than presenting the surgical option for an extra-maxillary approach. It would appear logical that ZIs not breaching the sinus wall would not be likely to cause sinusitis. Ultimately, the patient’s individual anatomy and the desired prosthetic envelope, dictate the ZIs trajectory towards an intra- or extra-sinus approach.
When sinusitis was diagnosed, successful treatment with antibiotics and/or via a surgical meatotomy was reported with no further consequences. ZI failure due to loss of osseointegration, was infrequent when presented on a background of sinusitis, with surgical removal being the more common mode of ZI loss to treat un-resolving sinusitis. This suggests sinusitis may not always be a catastrophic event, although a concern of bacterial colonisation onto an exposed ZI surface within the sinus, with subsequent inflammation or infection might be prudent. Petruson [44] conducted sinuscopies on patients whose ZIs had been in function after at least 1 year. Total or partial mucosal coverage had occurred with no signs of infection or increased secretion. However, there is potential evidence to show that inflammatory bone changes may occur, as Bothur et al. [28] reported signs of osteitis when examining sinus walls (not directly surgically altered) after ZI placement. New bone development, measured radiographically, was seen in all patients within at least one of their sinuses. Di Cosola et al. [30] reported that a sinus mucosa thickness of > 3 mm was related to an increased odds ratio (1:2.8) of infective complications (sinusitis, oro-antral fistula, infection of the soft tissues). Obstruction of the osteum was not associated with implant failure or infective complications. Davo et al. reported no clinical consequences in patients who exhibited radiological thickening of the sinus mucosa associated with zygomatic implants [45]. It appears that ZIs within the sinus are not always a cause of clinically diagnosed or reported sinusitis, and that antibiotic therapy or surgery can successfully treat acute cases of sinusitis. Some cases may persist however, with a need to remove the ZI in order to resolve the situation.
Oro-antral communication was also linked to ZI loss [11, 13, 15, 19, 20]. Preventing oro-antral communications is reliant on hard or soft tissue attachment to the coronal aspect of the implant. It has been suggested that 2 stage procedures, with repeat surgery or abutment changes at this level, could have a negative effect [7]. Early infective processes may also jeopardise this seal, as potentially might bending movements when in function. Patient education, compliance in oral hygiene measures, and prosthesis cleansability are undoubtedly important in maintaining peri-ZI tissue health and for the long-term prevention of peri-ZI mucositis.

Patient reported outcomes with zygomatic implants

Across the studies, there was significant heterogeneity in recording patient reported outcomes. Few studies investigated PROMs with the same tool, which made comparison between studies impossible. PROMs where investigated via the OHIP 14 system [16, 18] developed by Slade et al. [46], the OHIP EDENT [11] or via Likert-style questionnaires [13]. Improvements were reported in all studies comparing qualify of life (QoL) start points to end points. When considering conventional implant literature and associated reconstructions, edentulous patients report improvements in satisfaction when provided with implant retained or supported prostheses, regardless of fixed or removable design. Removable was found to be preferential for performing hygiene related procedures [47]. In addition, either immediate or delayed reconstructions were found to be acceptable. Heydecke et al. [48], in a crossover study, found implant retained removable prostheses to be preferred over fixed reconstructions for phonetics. This was either due to prior patient experience with palatal coverage, or that not enough time was given for adaptation. An extended period for normalisation might therefore be recommended. Conversely, Brennan et al. [49], reported patients with fixed reconstructions were more satisfied than counterparts with removable reconstructions. Edentulism is recognised as having a detractive effect on the emotional status of patients [50]. Any implant-supported or retained reconstruction might reasonably be expected to improve QoL if individuals previously managed with conventional removable prostheses, or had undergone partial or total maxillary resection for trauma or oncology. Factors influencing satisfaction were comfort, aesthetics and phonetics. These are more challenging in ZI therapy, which may have a more palatal emergence profile of the implant platform related to the local anatomy and level of alveolar bone atrophy. This may lead to prostheses that encroach upon the palate, and might challenge patients’ adaptive capabilities. This relies on surgical skill coupled with prosthetically driven planning to reduce the chance of prosthetic complications. The use of PROMs and QoL assessments within ZI research is an essential component of patient-centred research, but standardised criteria and recording by investigators is recommended to construct a more detailed picture.

Limitations of the evidence

Limitations centred around the quality of reporting. Although the inclusion criteria of primary studies were clear, it was often unclear as to whether there had been consecutive and/or complete inclusion of the participants. As such, inclusion bias may have played a part in the selection of participants selected for studies. Older studies were less systematic in their approach to reporting. Patient demographics were generally well reported. Narrative results were sufficient to extract datasets that allowed the systematic review to be conducted along with the meta-analysis. Heterogeneity in reporting ZI success and PROMs was notable across the studies, which challenged comparisons. However, we tried to account for several factors that led to heterogeneity, e.g., the duration of follow-up (i.e. by calculating annual incidence rates) and loading protocol (i.e. by performing subgroup analysis).

Limitations of the review

This systematic review followed the PRISMA guidelines for reporting, which created a framework for the structure, assessment, introspection, and reporting process in order to conduct a review and analysis of the relevant literature. The main limitations were related to the study quality, as no clinical trials or randomised controlled trials were included. In addition, we were unable to analyse ZI success for all studies, or carry out further subgroup analyses of complications due to heterogeneity in reporting. Caution should be used when interpreting the results due to the lack of high-quality evidence.

Implications for practice and future research

These results indicate that ZIs are a predictable treatment modality for use in the atrophic maxilla, and represent a reconstructive therapy to consider against techniques including sinus augmentation with conventional implant rehabilitation. Five-year ZI survival rates appear comparable to conventional implants, although mean longer term comparable survival and complication data are still lacking. The reported survival rates are reassuring, as ZI therapy presents the opportunity for immediate reconstruction at the time of implant placement, and reduces both morbidity from donor site procedures and reduces overall treatment times. The study indicates that ZI-supported prosthetic reconstruction survival is satisfactory, with complications comparable to that experienced by reconstructions supported by conventional implants. Further investigation into ZI-supported prosthesis performance, material choices and prosthetic complications are required. Sinusitis appears to be a complication affecting around 14% of individuals with ZIs, but can respond to antibiotic or surgical treatment with total resolution. PROMs indicate that ZIs improve quality of life for those treated in this fashion.
Future research should be focused on the creation of uniform research core datasets to ensure standardised reporting within the field of ZIs, in order to capture and compare study data. There is also a need to identify guidelines for diagnosis and management of sinus pathology related to ZIs. Finally, standardised PROMs should be included when measuring clinical outcomes.

Conclusions

Zygomatic implants may represent a predictable treatment modality for management of the atrophic or resected maxilla, with comparable survival rates to conventional implants over similar time frames. Immediate loading showed a statistically significant increase in survival rates over delayed loading, but this difference may not be clinically significant. Prosthesis survival was satisfactory and similar to that of prostheses supported by conventional implants, with similar complications. Sinusitis was the most frequently encountered biological complication. Patient reported outcomes show an increase in satisfaction when rehabilitated with ZIs.

Acknowledgements

Evidence search carried out by Jo Hooper from the University Hospitals Bristol & Weston Library & Knowledge Services. Bristol:UK. Statistical analysis was conducted by Gareb Barzi. Advice on Risk of Bias tools was provided by Alex Gormley, PhD candidate, Restorative Department, Bristol Dental Hospital. This systematic review was initiated and steered by the Scientific Committee of the International Team for Implantology (ITI).

Declarations

Not applicable.
Not applicable.

Competing interests

Matthew Brennand Roper declares that he has no conflict of interests. He has a grant from BioHorizons outside and unrelated to the submitted work. The authors declare they have no competing interests.
Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://​creativecommons.​org/​licenses/​by/​4.​0/​.

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Literatur
1.
Zurück zum Zitat Jensen J, Sindet-Pedersen S, Oliver AJ. Varying treatment strategies for reconstruction of maxillary atrophy with implants: results in 98 patients. J Oral Maxillofac Surg. 1994;52(3):210–6 (discussion 216-8).PubMedCrossRef Jensen J, Sindet-Pedersen S, Oliver AJ. Varying treatment strategies for reconstruction of maxillary atrophy with implants: results in 98 patients. J Oral Maxillofac Surg. 1994;52(3):210–6 (discussion 216-8).PubMedCrossRef
2.
Zurück zum Zitat Aparicio C, Branemark PI, Keller EE, Olive J. Reconstruction of the premaxilla with autogenous iliac bone in combination with osseointegrated implants. Int J Oral Maxillofac Implants. 1993;8:61–7. Aparicio C, Branemark PI, Keller EE, Olive J. Reconstruction of the premaxilla with autogenous iliac bone in combination with osseointegrated implants. Int J Oral Maxillofac Implants. 1993;8:61–7.
3.
Zurück zum Zitat Bedrossian E, Rangert B, Stumpel L, Indresano T. Immediate function with the zygomatic implant: a graftless solution for the patient with mild to advanced atrophy of the maxilla. Int J Oral Maxillofac Implants. 2006;21(6):937–42.PubMed Bedrossian E, Rangert B, Stumpel L, Indresano T. Immediate function with the zygomatic implant: a graftless solution for the patient with mild to advanced atrophy of the maxilla. Int J Oral Maxillofac Implants. 2006;21(6):937–42.PubMed
4.
Zurück zum Zitat Butterworth CJ, Lowe D, Rogers SN. The Zygomatic Implant Perforated (ZIP) flap reconstructive technique for the management of low-level maxillary malignancy—clinical & patient related outcomes on 35 consecutively treated patients. Head Neck. 2022;44(2):345–58.PubMedCrossRef Butterworth CJ, Lowe D, Rogers SN. The Zygomatic Implant Perforated (ZIP) flap reconstructive technique for the management of low-level maxillary malignancy—clinical & patient related outcomes on 35 consecutively treated patients. Head Neck. 2022;44(2):345–58.PubMedCrossRef
5.
Zurück zum Zitat Duarte LR, Filho HN, Francischone CE, Peredo LG, Brånemark PI. The establishment of a protocol for the total rehabilitation of atrophic maxillae employing four zygomatic fixtures in an immediate loading system—a 30-month clinical and radiographic follow-up. Clin Implant Dent Relat Res. 2007;9(4):186–96.PubMedCrossRef Duarte LR, Filho HN, Francischone CE, Peredo LG, Brånemark PI. The establishment of a protocol for the total rehabilitation of atrophic maxillae employing four zygomatic fixtures in an immediate loading system—a 30-month clinical and radiographic follow-up. Clin Implant Dent Relat Res. 2007;9(4):186–96.PubMedCrossRef
6.
Zurück zum Zitat Chow J, Hui E, Lee PK, Li W. Zygomatic implants–protocol for immediate occlusal loading: a preliminary report. J Oral Maxillofac Surg. 2006;64(5):804–11.PubMedCrossRef Chow J, Hui E, Lee PK, Li W. Zygomatic implants–protocol for immediate occlusal loading: a preliminary report. J Oral Maxillofac Surg. 2006;64(5):804–11.PubMedCrossRef
7.
Zurück zum Zitat Davó R, Malevez C, Rojas J, Rodríguez J, Regolf J. Clinical outcome of 42 patients treated with 81 immediately loaded zygomatic implants: a 12- to 42-month retrospective study. Eur J Oral Implantol. 2008;9(Suppl 1):141–50.PubMed Davó R, Malevez C, Rojas J, Rodríguez J, Regolf J. Clinical outcome of 42 patients treated with 81 immediately loaded zygomatic implants: a 12- to 42-month retrospective study. Eur J Oral Implantol. 2008;9(Suppl 1):141–50.PubMed
8.
Zurück zum Zitat Krekmanov L, Kahn M, Rangert B, Lindström H. Tilting of posterior mandibular and maxillary implants for improved prosthesis support. Int J Oral Maxillofac Implants. 2000;15(3):405–14.PubMed Krekmanov L, Kahn M, Rangert B, Lindström H. Tilting of posterior mandibular and maxillary implants for improved prosthesis support. Int J Oral Maxillofac Implants. 2000;15(3):405–14.PubMed
9.
Zurück zum Zitat Aparicio C, Ouazzani W, Aparicio A, Fortes V, Muela R, Pascual A, Codesal M, Barluenga N, Franch M. Immediate/early loading of zygomatic implants: clinical experiences after 2 to 5 years of follow-up. Clin Implant Dent Relat Res. 2010;12(Suppl1):e77-82.PubMed Aparicio C, Ouazzani W, Aparicio A, Fortes V, Muela R, Pascual A, Codesal M, Barluenga N, Franch M. Immediate/early loading of zygomatic implants: clinical experiences after 2 to 5 years of follow-up. Clin Implant Dent Relat Res. 2010;12(Suppl1):e77-82.PubMed
10.
Zurück zum Zitat Ahlgren F, Størksen K, Tornes K. A study of 25 zygomatic dental implants with 11 to 49 months follow-up after loading. Int J Oral Maxillofac Implants. 2006;21(3):421–5.PubMed Ahlgren F, Størksen K, Tornes K. A study of 25 zygomatic dental implants with 11 to 49 months follow-up after loading. Int J Oral Maxillofac Implants. 2006;21(3):421–5.PubMed
11.
Zurück zum Zitat Aparicio C, Manresa C, Francisco K, Aparicio A, Nunes J, Claros P, Potau J. Zygomatic implants placed using the zygomatic anatomy guided approach versus the classical technique: a proposed system to report rhinosinusitis diagnosis. Clin Implant Dent Relat Res. 2014;16:627–42.PubMedCrossRef Aparicio C, Manresa C, Francisco K, Aparicio A, Nunes J, Claros P, Potau J. Zygomatic implants placed using the zygomatic anatomy guided approach versus the classical technique: a proposed system to report rhinosinusitis diagnosis. Clin Implant Dent Relat Res. 2014;16:627–42.PubMedCrossRef
12.
Zurück zum Zitat Maló P, Nobre Mde A, Lopes I. A new approach to rehabilitate the severely atrophic maxilla using extramaxillary anchored implants in immediate function: a pilot study. J Prosthet Dent. 2008;100(5):354–66.PubMedCrossRef Maló P, Nobre Mde A, Lopes I. A new approach to rehabilitate the severely atrophic maxilla using extramaxillary anchored implants in immediate function: a pilot study. J Prosthet Dent. 2008;100(5):354–66.PubMedCrossRef
13.
Zurück zum Zitat Agliardi E, Romeo D, Panigatti S, de Araujo Nobre M, Malo P. Immediate full- arch rehabilitation of the severely atrophic maxilla supported by zygomatic implants: a prospective clinical study with minimum follow-up of 6 years. Int J Oral Maxillofac Surg. 2017;46:1592–9.PubMedCrossRef Agliardi E, Romeo D, Panigatti S, de Araujo Nobre M, Malo P. Immediate full- arch rehabilitation of the severely atrophic maxilla supported by zygomatic implants: a prospective clinical study with minimum follow-up of 6 years. Int J Oral Maxillofac Surg. 2017;46:1592–9.PubMedCrossRef
14.
Zurück zum Zitat Higgins JPT, Thomas J, Chandler J, Cumpston M, Li T, Page MJ, Welch VA (editors). Cochrane handbook for systematic reviews of interventions version 6.3 (updated February 2022). Cochrane, 2022. Higgins JPT, Thomas J, Chandler J, Cumpston M, Li T, Page MJ, Welch VA (editors). Cochrane handbook for systematic reviews of interventions version 6.3 (updated February 2022). Cochrane, 2022.
15.
Zurück zum Zitat Kahnberg K-E, Henry P, Hirsch J-M, Ohrnell L-O, Andreasson L, Branemarl P-I, Chiapasco M, Gynther G, Finne K, Higuchi K, Isaksson S, Malevez C, Neukam F, Sevetz E, Urgell J, Widmark G, Bolind P. Clinical evaluation of the zygoma implant: 3-year follow-up at 16 clinics. J Oral Maillofac Surg. 2007;65:2033–8.CrossRef Kahnberg K-E, Henry P, Hirsch J-M, Ohrnell L-O, Andreasson L, Branemarl P-I, Chiapasco M, Gynther G, Finne K, Higuchi K, Isaksson S, Malevez C, Neukam F, Sevetz E, Urgell J, Widmark G, Bolind P. Clinical evaluation of the zygoma implant: 3-year follow-up at 16 clinics. J Oral Maillofac Surg. 2007;65:2033–8.CrossRef
16.
Zurück zum Zitat Pellegrino G, Francesco Basile F, Relics D, Ferri A, Grande F, Tarsitano A, Marchetti C. Computer-aided rehabilitation supported by zygomatic implants: a cohort study comparing atrophic with oncologic patients after five years of follow-up. J Clin Med. 2020;9:3254.PubMedPubMedCentralCrossRef Pellegrino G, Francesco Basile F, Relics D, Ferri A, Grande F, Tarsitano A, Marchetti C. Computer-aided rehabilitation supported by zygomatic implants: a cohort study comparing atrophic with oncologic patients after five years of follow-up. J Clin Med. 2020;9:3254.PubMedPubMedCentralCrossRef
17.
Zurück zum Zitat Coppede A, de Mayo T, de sa Zamper-lini M, Amorin R, DePadua APAT, Shibli JA. Three-year clinical prospective follow-up of extrasinus zygomatic implants for the rehabilitation of the atrophic maxilla. Clin Implant Dent Relat Res. 2017;19:926–34.PubMedCrossRef Coppede A, de Mayo T, de sa Zamper-lini M, Amorin R, DePadua APAT, Shibli JA. Three-year clinical prospective follow-up of extrasinus zygomatic implants for the rehabilitation of the atrophic maxilla. Clin Implant Dent Relat Res. 2017;19:926–34.PubMedCrossRef
18.
Zurück zum Zitat Davo R, Pons O. 5-year outcome of cross-arch prostheses supported by four immediately loaded zygomatic implants: a prospective case series. Eur J Oral Implantol. 2015;8:169–74.PubMed Davo R, Pons O. 5-year outcome of cross-arch prostheses supported by four immediately loaded zygomatic implants: a prospective case series. Eur J Oral Implantol. 2015;8:169–74.PubMed
19.
Zurück zum Zitat Malo P, de Araujo NM, Lopes A, Ferro A, Moss S. Five-year outcome of a retrospective cohort study on the rehabilitation of completely edentulous atrophic maxillae with immediate loaded zygomatic implants placed extra-maxillary. Eur J Oral Implantol. 2014;7:267–81.PubMed Malo P, de Araujo NM, Lopes A, Ferro A, Moss S. Five-year outcome of a retrospective cohort study on the rehabilitation of completely edentulous atrophic maxillae with immediate loaded zygomatic implants placed extra-maxillary. Eur J Oral Implantol. 2014;7:267–81.PubMed
20.
Zurück zum Zitat Davo R, Malevez C, Pons O. Immediately loaded zygomatic implants: a five year prospective study. Eur J Oral Implantol. 2013;6:39–47.PubMed Davo R, Malevez C, Pons O. Immediately loaded zygomatic implants: a five year prospective study. Eur J Oral Implantol. 2013;6:39–47.PubMed
21.
Zurück zum Zitat Davo R. Zygomatic implants placed with a two-stage procedure: a 5-year retrospective study. Eur J Oral Implantol. 2009;2:115–24.PubMed Davo R. Zygomatic implants placed with a two-stage procedure: a 5-year retrospective study. Eur J Oral Implantol. 2009;2:115–24.PubMed
22.
Zurück zum Zitat Brånemark PI, Gröndahl K, Ohrnell LO, Nilsson P, Petruson B, Svensson B, Engstrand P, Nannmark U. Zygoma fixture in the management of advanced atrophy of the maxilla: technique and long-term results. Scand J Plast Reconstr Surg Hand Surg. 2004;38(2):70–85.PubMedCrossRef Brånemark PI, Gröndahl K, Ohrnell LO, Nilsson P, Petruson B, Svensson B, Engstrand P, Nannmark U. Zygoma fixture in the management of advanced atrophy of the maxilla: technique and long-term results. Scand J Plast Reconstr Surg Hand Surg. 2004;38(2):70–85.PubMedCrossRef
23.
Zurück zum Zitat Yates J, Brook I, Patel R, Wragg P, Atkins S, El-Awa A, Bakri I, Bolt R. Treatment of the edentulous atrophic maxilla using zygomatic implants: evaluation of survival rates over 5–10 years. Int J Oral Maxillofac Surg. 2014;43:237–42.PubMedCrossRef Yates J, Brook I, Patel R, Wragg P, Atkins S, El-Awa A, Bakri I, Bolt R. Treatment of the edentulous atrophic maxilla using zygomatic implants: evaluation of survival rates over 5–10 years. Int J Oral Maxillofac Surg. 2014;43:237–42.PubMedCrossRef
24.
Zurück zum Zitat Bedrossian E. Rehabilitation of the edentulous maxilla with the zygoma concept: a 7-year prospective study. Int J Oral Maxillofac Implants. 2010;25:1213–21.PubMed Bedrossian E. Rehabilitation of the edentulous maxilla with the zygoma concept: a 7-year prospective study. Int J Oral Maxillofac Implants. 2010;25:1213–21.PubMed
25.
Zurück zum Zitat Chana H, Smith G, Bansal H, Zahra D. A retrospective cohort study of the survival rate of 88 zygomatic implants placed over an 18 year period. Int J Oral Maxillofac Implants. 2019;34:461–70.PubMedCrossRef Chana H, Smith G, Bansal H, Zahra D. A retrospective cohort study of the survival rate of 88 zygomatic implants placed over an 18 year period. Int J Oral Maxillofac Implants. 2019;34:461–70.PubMedCrossRef
26.
Zurück zum Zitat Miglioranca R, Sotto-Maior B, Senna P, Francischone C, Del Bel CA. Immediate occlusal loading of extrasinus zygomatic implants: a prospective cohort study with a follow-up period of 8 years. Int J Oral Maxillofac Surg. 2012;41:1072–6.PubMedCrossRef Miglioranca R, Sotto-Maior B, Senna P, Francischone C, Del Bel CA. Immediate occlusal loading of extrasinus zygomatic implants: a prospective cohort study with a follow-up period of 8 years. Int J Oral Maxillofac Surg. 2012;41:1072–6.PubMedCrossRef
27.
Zurück zum Zitat Fortin Y. Placement of zygomatic implants into the male prominence of the maxillary bone for apical fixation: a clinical report 5 to 13 years. Int J Oral Maxillofac Implants. 2017;32:633–41.PubMedCrossRef Fortin Y. Placement of zygomatic implants into the male prominence of the maxillary bone for apical fixation: a clinical report 5 to 13 years. Int J Oral Maxillofac Implants. 2017;32:633–41.PubMedCrossRef
28.
Zurück zum Zitat Bothur S, Kullendorff B, Olsson-Sandin G. Asymptomatic chronic rhinosinusitis and osteitis in patients treated with multiple zygomatic implants: a long-term radiographic follow-up. Int J Oral Maxillofac Implants. 2015;30:161–8.PubMedCrossRef Bothur S, Kullendorff B, Olsson-Sandin G. Asymptomatic chronic rhinosinusitis and osteitis in patients treated with multiple zygomatic implants: a long-term radiographic follow-up. Int J Oral Maxillofac Implants. 2015;30:161–8.PubMedCrossRef
29.
Zurück zum Zitat Aparicio C, Manresa C, Francisco K, Ouazzani W, Claros P, Potau J, Aparicio A. The long-term use of zygomatic implants: a 10-year clinical and radiographic report. Clin Implant Dent Relat Res. 2014;16(3):447–59.PubMedCrossRef Aparicio C, Manresa C, Francisco K, Ouazzani W, Claros P, Potau J, Aparicio A. The long-term use of zygomatic implants: a 10-year clinical and radiographic report. Clin Implant Dent Relat Res. 2014;16(3):447–59.PubMedCrossRef
30.
Zurück zum Zitat Di Cosola M, Ballini A, Zhurakivska K, Ceccarello A, Nocini R, Malcangi A, Mori G, Lo Muzio L, Cantore S, Olivo A. Retrospective analysis of clinical and radiologic data regarding zygomatic implant rehabilitation with a long-term follow-up. Int J Environ Res Public Health. 2021;18:12963.PubMedPubMedCentralCrossRef Di Cosola M, Ballini A, Zhurakivska K, Ceccarello A, Nocini R, Malcangi A, Mori G, Lo Muzio L, Cantore S, Olivo A. Retrospective analysis of clinical and radiologic data regarding zygomatic implant rehabilitation with a long-term follow-up. Int J Environ Res Public Health. 2021;18:12963.PubMedPubMedCentralCrossRef
31.
Zurück zum Zitat Aparicio C. A proposed classification for zygomatic implants based on the zygoma anatomy guided approach (ZAGA). A cross-sectional survey. Eur J Oral Implantol. 2011;4:269–75.PubMed Aparicio C. A proposed classification for zygomatic implants based on the zygoma anatomy guided approach (ZAGA). A cross-sectional survey. Eur J Oral Implantol. 2011;4:269–75.PubMed
32.
Zurück zum Zitat Chrcanovic BR, Albrektsson T, Wennerberg A. Survival and complications of zygomatic implants: an updated systematic review. J Oral Maxillofac Surg. 2016;74:1949–64.PubMedCrossRef Chrcanovic BR, Albrektsson T, Wennerberg A. Survival and complications of zygomatic implants: an updated systematic review. J Oral Maxillofac Surg. 2016;74:1949–64.PubMedCrossRef
33.
Zurück zum Zitat Solà Pérez A, Pastorino D, Aparicio C, Pegueroles Neyra M, Khan RS, Wright S, Ucer C. Success rates of zygomatic implants for the rehabilitation of severely atrophic maxilla: a systematic review. Dent J. 2022;10:151.CrossRef Solà Pérez A, Pastorino D, Aparicio C, Pegueroles Neyra M, Khan RS, Wright S, Ucer C. Success rates of zygomatic implants for the rehabilitation of severely atrophic maxilla: a systematic review. Dent J. 2022;10:151.CrossRef
34.
Zurück zum Zitat Chrcanovic BR, Abreu MH. Survival and complications of zygomatic implants: a systematic review. Oral Maxillofac Surg. 2003;17:81.CrossRef Chrcanovic BR, Abreu MH. Survival and complications of zygomatic implants: a systematic review. Oral Maxillofac Surg. 2003;17:81.CrossRef
35.
Zurück zum Zitat Moraschini V, de Queiroz TR, Sartoretto SC, de Almeida DCF, Calasans-Maia MD, Louro RS. Survival and complications of zygomatic implants compared to conventional implants reported in longitudinal studies with a follow-up period of at least 5 years: a systematic review and meta-analysis. Clin Implant Dent Relat Res. 2022;1–13. Moraschini V, de Queiroz TR, Sartoretto SC, de Almeida DCF, Calasans-Maia MD, Louro RS. Survival and complications of zygomatic implants compared to conventional implants reported in longitudinal studies with a follow-up period of at least 5 years: a systematic review and meta-analysis. Clin Implant Dent Relat Res. 2022;1–13.
36.
Zurück zum Zitat Slot W, Raghoebar GM, Cune MS, Vissink A, Meijer HJA. Maxillary overdentures supported by four or six implants in the anterior region: 10-year randomized controlled trial results. J Clin Periodontol. 2023;50(1):36–44.PubMedCrossRef Slot W, Raghoebar GM, Cune MS, Vissink A, Meijer HJA. Maxillary overdentures supported by four or six implants in the anterior region: 10-year randomized controlled trial results. J Clin Periodontol. 2023;50(1):36–44.PubMedCrossRef
37.
Zurück zum Zitat Kotsovilis S, Fourmousis I, Karroussis IK, Bamia C. A systematic review and meta-analysis on the effect of implant length on the survival of rough surface dental implants. J Periodontol. 2009;80:1700–18.PubMedCrossRef Kotsovilis S, Fourmousis I, Karroussis IK, Bamia C. A systematic review and meta-analysis on the effect of implant length on the survival of rough surface dental implants. J Periodontol. 2009;80:1700–18.PubMedCrossRef
38.
Zurück zum Zitat Albrektsson T, Isador F. Consensus report of Session IV. In: Lang NP, Karring T, editors. Proceedings of the 1st European Workshop on Periodontology. London: Quintessence. 1994;365–369. Albrektsson T, Isador F. Consensus report of Session IV. In: Lang NP, Karring T, editors. Proceedings of the 1st European Workshop on Periodontology. London: Quintessence. 1994;365–369.
39.
Zurück zum Zitat Malevez C, Abarca M, Durdu F, Daelemans P. Clinical outcome of 103 consecutive zygomatic implants: a 6–48 months follow-up study. Clin Oral Implants Res. 2004;15:18–22.PubMedCrossRef Malevez C, Abarca M, Durdu F, Daelemans P. Clinical outcome of 103 consecutive zygomatic implants: a 6–48 months follow-up study. Clin Oral Implants Res. 2004;15:18–22.PubMedCrossRef
40.
Zurück zum Zitat Aparicio C, Lopez-Piriz R, Albrektsson T. ORIS criteria of success for the zygoma-related rehabilitation: the (revisited) zygoma success code. Int J Oral Maxillofac Implants. 2020;35:366–78.PubMedCrossRef Aparicio C, Lopez-Piriz R, Albrektsson T. ORIS criteria of success for the zygoma-related rehabilitation: the (revisited) zygoma success code. Int J Oral Maxillofac Implants. 2020;35:366–78.PubMedCrossRef
41.
Zurück zum Zitat Wittneben JG, Millen C, Brägger U. Clinical performance of screw- versus cement-retained fixed implant-supported reconstructions—a systematic review. Int J Oral Maxillofac Implants. 2014;29(Suppl):84–98.PubMedCrossRef Wittneben JG, Millen C, Brägger U. Clinical performance of screw- versus cement-retained fixed implant-supported reconstructions—a systematic review. Int J Oral Maxillofac Implants. 2014;29(Suppl):84–98.PubMedCrossRef
42.
Zurück zum Zitat Sailer I, Muhlemann S, Zwahlen M, Hammerle CHF, Schneider D. Cemented and screw-retained implant reconstructions: a systematic review of the survival and complication rates. Clin Oral Implants Res. 2012;23(Suppl. 6):163–201.PubMedCrossRef Sailer I, Muhlemann S, Zwahlen M, Hammerle CHF, Schneider D. Cemented and screw-retained implant reconstructions: a systematic review of the survival and complication rates. Clin Oral Implants Res. 2012;23(Suppl. 6):163–201.PubMedCrossRef
43.
Zurück zum Zitat Sedaghat AR, Kuan EC, Scadding GK. Epidemiology of chronic rhinosinusitis: prevalence and risk factors. J Allergy Clin Immunol Pract. 2022;10(6):1395–403.PubMedCrossRef Sedaghat AR, Kuan EC, Scadding GK. Epidemiology of chronic rhinosinusitis: prevalence and risk factors. J Allergy Clin Immunol Pract. 2022;10(6):1395–403.PubMedCrossRef
44.
Zurück zum Zitat Petruson B. Sinuscopy in patients with titanium implants in the nose and sinuses. Scand J Plast Reconstr Surg Hand Surg. 2004;38(2):86–93.PubMedCrossRef Petruson B. Sinuscopy in patients with titanium implants in the nose and sinuses. Scand J Plast Reconstr Surg Hand Surg. 2004;38(2):86–93.PubMedCrossRef
45.
Zurück zum Zitat Davo R, Malevez C, Lopez-Orellana C, Pastor-Bevia F, Rojas J. Sinus reactions to immediately loaded zygomatic implants: clinical and radiological study. Eur J Oral Implantol. 2008;1:53–60.PubMed Davo R, Malevez C, Lopez-Orellana C, Pastor-Bevia F, Rojas J. Sinus reactions to immediately loaded zygomatic implants: clinical and radiological study. Eur J Oral Implantol. 2008;1:53–60.PubMed
46.
Zurück zum Zitat Slade GD. Derivation and validation of a short-form oral health impact profile. Community Dent Oral Epidemiol. 1997;25(4):284–90.PubMedCrossRef Slade GD. Derivation and validation of a short-form oral health impact profile. Community Dent Oral Epidemiol. 1997;25(4):284–90.PubMedCrossRef
47.
Zurück zum Zitat Feine J, Abou-Ayash S, Al Mardini M, de Santana RB, Bjelke-Holtermann T, Bornstein MM, Braegger U, Cao O, Cordaro L, Eycken D, Fillion M, Gebran G, Huynh-Ba G, Joda T, Levine R, Mattheos N, Oates TW, Abd-Ul-Salam H, Santosa R, Shahdad S, Storelli S, Sykaras N, Treviño Santos A, Stephanie Webersberger U, Williams MAH, Wilson TG Jr, Wismeijer D, Wittneben JG, Yao CJ, Zubiria JPV. Group 3 ITI Consensus Report: patient-reported outcome measures associated with implant dentistry. Clin Oral Implants Res. 2018;29(Suppl16):270–5.PubMedCrossRef Feine J, Abou-Ayash S, Al Mardini M, de Santana RB, Bjelke-Holtermann T, Bornstein MM, Braegger U, Cao O, Cordaro L, Eycken D, Fillion M, Gebran G, Huynh-Ba G, Joda T, Levine R, Mattheos N, Oates TW, Abd-Ul-Salam H, Santosa R, Shahdad S, Storelli S, Sykaras N, Treviño Santos A, Stephanie Webersberger U, Williams MAH, Wilson TG Jr, Wismeijer D, Wittneben JG, Yao CJ, Zubiria JPV. Group 3 ITI Consensus Report: patient-reported outcome measures associated with implant dentistry. Clin Oral Implants Res. 2018;29(Suppl16):270–5.PubMedCrossRef
48.
Zurück zum Zitat Heydecke G, Boudrias P, Awad MA, De Albuquerque RF, Lund JP, Feine JS. Within-subject comparisons of maxillary fixed and removable implant prostheses: patient satisfaction and choice of prosthesis. Clin Oral Implants Res. 2003;14(1):125–30.PubMedCrossRef Heydecke G, Boudrias P, Awad MA, De Albuquerque RF, Lund JP, Feine JS. Within-subject comparisons of maxillary fixed and removable implant prostheses: patient satisfaction and choice of prosthesis. Clin Oral Implants Res. 2003;14(1):125–30.PubMedCrossRef
49.
Zurück zum Zitat Brennan M, Houston F, O’Sullivan M, O’Connell B. Patient satisfaction and oral health-related quality of life outcomes of implant overdentures and fixed complete dentures. Int J Oral Maxillofac Implants. 2010;25(4):791–800.PubMed Brennan M, Houston F, O’Sullivan M, O’Connell B. Patient satisfaction and oral health-related quality of life outcomes of implant overdentures and fixed complete dentures. Int J Oral Maxillofac Implants. 2010;25(4):791–800.PubMed
50.
Zurück zum Zitat Fiske J, Davis DM, Frances C, Gelbier S. The emotional effects of tooth loss in edentulous people. Br Dent J. 1998;184(2):90–3 (discussion 79).PubMedCrossRef Fiske J, Davis DM, Frances C, Gelbier S. The emotional effects of tooth loss in edentulous people. Br Dent J. 1998;184(2):90–3 (discussion 79).PubMedCrossRef
51.
Zurück zum Zitat Migliorança RM, Coppedê A, Dias Rezende RC, de Mayo T. Restoration of the edentulous maxilla using extrasinus zygomatic implants combined with anterior conventional implants: a retrospective study. Int J Oral Maxillofac Implants. 2011;26(3):665–72 (PMID: 21691615).PubMed Migliorança RM, Coppedê A, Dias Rezende RC, de Mayo T. Restoration of the edentulous maxilla using extrasinus zygomatic implants combined with anterior conventional implants: a retrospective study. Int J Oral Maxillofac Implants. 2011;26(3):665–72 (PMID: 21691615).PubMed
Metadaten
Titel
Long-term treatment outcomes with zygomatic implants: a systematic review and meta-analysis
verfasst von
Matthew Brennand Roper
Arjan Vissink
Tom Dudding
Alex Pollard
Barzi Gareb
Chantal Malevez
Thomas Balshi
Lawrence Brecht
Vinay Kumar
Yiqun Wu
Ronald Jung
Publikationsdatum
01.12.2023
Verlag
Springer Berlin Heidelberg
Erschienen in
International Journal of Implant Dentistry / Ausgabe 1/2023
Elektronische ISSN: 2198-4034
DOI
https://doi.org/10.1186/s40729-023-00479-x

Weitere Artikel der Ausgabe 1/2023

International Journal of Implant Dentistry 1/2023 Zur Ausgabe

Neu im Fachgebiet Zahnmedizin

Sechs Monate E-Rezept – Erfolgsgeschichte mit Schattenseiten

IT für Ärzte Nachrichten

244 Millionen E-Rezepte sind in sechs Monaten eingelöst worden: Nach einem halben Jahr zieht die Betriebsgesellschaft gematik eine positive Zwischenbilanz. Doch noch sind nicht alle Akteure begeistert.

So können sich Praxen vor Cyberkriminalität schützen

IT für Ärzte Nachrichten

Immer wieder werden Arztpraxen Opfer von Netzverbrechern. Der typische Hacker war einmal, Cyberkriminalität ist sehr vielfältig, berichtet Lars Korunalp. Der IT-Berater gibt Tipps und nennt konkrete Maßnahmen, wie sich Praxen vor Zugriffen aus dem Internet schützen können.

Thüringer Landtag beschließt Vorab-Quote im Medizinstudium

Bewerber, die sich zu einer langen Tätigkeit als Haus- oder Zahnarzt in Thüringen verpflichten, bekommen in Jena künftig leichter einen Studienplatz. Sechs Prozent der Plätze sollen so vergeben werden.

Notfallreform: Lauterbach nimmt KVen und ausgewählte Kliniken in die Pflicht

06.06.2024 Klinik aktuell Nachrichten

Die Ampelkoalition nimmt einen neuen Anlauf für die Reform der Notfallversorgung. Der Gesetzentwurf zeigt: Die Vertragsärzte müssen sich auf erhebliche Veränderungen in der Organisation der Notdienste einstellen.

Update Zahnmedizin

Bestellen Sie unseren kostenlosen Newsletter und bleiben Sie gut informiert – ganz bequem per eMail.