Skip to main content
main-content

15.12.2015 | Original Article | Ausgabe 3/2017

Clinical Neuroradiology 3/2017

Low-Dose Volume-Perfusion CT of the Brain: Effects of Radiation Dose Reduction on Performance of Perfusion CT Algorithms

Zeitschrift:
Clinical Neuroradiology > Ausgabe 3/2017
Autoren:
MD A. E. Othman, S. Afat, C. Brockmann, O. Nikoubashman, G. Bier, M. A. Brockmann, K. Nikolaou, J. H. Tai, Z. P. Yang, J. H. Kim, M. Wiesmann

Abstract

Purpose

We aimed to compare different computed tomography (CT) perfusion post-processing algorithms regarding image quality of perfusion maps from low-dose volume perfusion CT (VPCT) and their diagnostic performance regarding the detection of ischemic brain lesions.

Methods and Materials

We included VPCT data of 21 patients with acute stroke (onset < 6h), which were acquired at 80 kV and 180 mAs. Low-dose VPCT datasets with 72 mAs (40 % of original dose) were generated using realistic low-dose simulation. Perfusion maps (cerebral blood volume (CBV); cerebral blood flow (CBF) from original and low-dose datasets were generated using two different commercially available post-processing methods: deconvolution-based method (DC) and maximum slope algorithm (MS). The resulting DC and MS perfusion maps were compared regarding perfusion values, signal-to-noise ratio (SNR) as well as image quality and diagnostic accuracy as rated by two blinded neuroradiologists.

Results

Quantitative perfusion parameters highly correlated for both algorithms and both dose levels (r ≥ 0.613, p < 0.001). Regarding SNR levels and image quality of the CBV maps, no significant differences between DC and MS were found (p ≥ 0.683). Low-dose MS CBF maps yielded significantly higher SNR levels (p < 0.001) and quality scores (p = 0.014) than those of DC. Low-dose CBF and CBV maps from both DC and MS yielded high sensitivity and specificity for the detection of ischemic lesions (sensitivity ≥ 0.82, specificity ≥ 0.90).

Conclusion

Our results indicate that both methods produce diagnostically sufficient perfusion maps from simulated low-dose VPCT. However, MS produced CBF maps with significantly higher image quality and SNR than DC, indicating that MS might be more suitable for low-dose VPCT imaging.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag als Mediziner

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

Alle e.Med Abos bis 30. April 2021 zum halben Preis!

Jetzt e.Med zum Sonderpreis bestellen!

Weitere Produktempfehlungen anzeigen
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 3/2017

Clinical Neuroradiology 3/2017 Zur Ausgabe
  1. Sie können e.Med Neurologie & Psychiatrie 14 Tage kostenlos testen (keine Print-Zeitschrift enthalten). Der Test läuft automatisch und formlos aus. Es kann nur einmal getestet werden.

  2. Sie können e.Med Neurologie 14 Tage kostenlos testen (keine Print-Zeitschrift enthalten). Der Test läuft automatisch und formlos aus. Es kann nur einmal getestet werden.

  3. Sie können e.Med Radiologie 14 Tage kostenlos testen (keine Print-Zeitschrift enthalten). Der Test läuft automatisch und formlos aus. Es kann nur einmal getestet werden.

Neu im Fachgebiet Radiologie

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Radiologie und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise