Several techniques are now available to detect and quantify pulmonary edema, from the laboratory postmortem method (gravimetry) to non-invasive wearable sensors. In critically ill patients with adult respiratory distress syndrome (ARDS), computed tomography scans are often performed to visualize lung lesions and quantify lung aeration, but their value seems somewhat limited to quantify pulmonary edema on a routine basis and of course to track changes with therapy. In this context, transpulmonary thermodilution is a convenient technique. It is invasive but most patients with ARDS have a central line and an arterial catheter in place. In addition to extravascular lung water measurements, transpulmonary thermodilution enables the measurement of hemodynamic variables that are useful to guide fluid and diuretic therapy. Echo probes are about to replace the stethoscope in our pocket and, if B lines (aka comet tails) do not allow a real quantification of pulmonary edema, they are useful to detect an increase in lung water. Finally, wireless and wearable sensors are now available to monitor patients on hospital wards and beyond (home monitoring). They should enable the detection of pulmonary congestion at a very early stage, and if combined with a proactive therapeutic strategy, have potential to improve outcome.
Literatur
1.
Zurück zum Zitat Michard F. Bedside assessment of extravascular lung water by dilution methods: temptations and pitfalls. Crit Care Med. 2007;35:1186–92.CrossRefPubMed Michard F. Bedside assessment of extravascular lung water by dilution methods: temptations and pitfalls. Crit Care Med. 2007;35:1186–92.CrossRefPubMed
2.
Zurück zum Zitat Patroniti N, Bellani G, Maggioni E, et al. Measurement of pulmonary edema in patients with acute respiratory distress syndrome. Crit Care Med. 2005;33:2547–54.CrossRefPubMed Patroniti N, Bellani G, Maggioni E, et al. Measurement of pulmonary edema in patients with acute respiratory distress syndrome. Crit Care Med. 2005;33:2547–54.CrossRefPubMed
3.
Zurück zum Zitat Lewis FR, Elings VB, Hill SL, Christensen JM. The measurement of extravascular lung water by thermal-green dye indicator dilution. Ann N Y Acad Sci. 1982;384:394–410.CrossRefPubMed Lewis FR, Elings VB, Hill SL, Christensen JM. The measurement of extravascular lung water by thermal-green dye indicator dilution. Ann N Y Acad Sci. 1982;384:394–410.CrossRefPubMed
4.
Zurück zum Zitat Mihm FG, Feeley TW, Jamieson SW. Thermal dye double indicator dilution measurement of lung water in man: comparison with gravimetric measurements. Thorax. 1987;42:72–6.CrossRefPubMedPubMedCentral Mihm FG, Feeley TW, Jamieson SW. Thermal dye double indicator dilution measurement of lung water in man: comparison with gravimetric measurements. Thorax. 1987;42:72–6.CrossRefPubMedPubMedCentral
5.
Zurück zum Zitat Sakka SG, Ruhl CC, Pfeiffer UJ, et al. Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution. Intensive Care Med. 2000;26:180–7.CrossRefPubMed Sakka SG, Ruhl CC, Pfeiffer UJ, et al. Assessment of cardiac preload and extravascular lung water by single transpulmonary thermodilution. Intensive Care Med. 2000;26:180–7.CrossRefPubMed
7.
Zurück zum Zitat Michard F, Schachtrupp A, Toens C. Factors influencing the estimation of extravascular lung water by transpulmonary thermodilution in critically ill patients. Crit Care Med. 2005;33:1243–7.CrossRefPubMed Michard F, Schachtrupp A, Toens C. Factors influencing the estimation of extravascular lung water by transpulmonary thermodilution in critically ill patients. Crit Care Med. 2005;33:1243–7.CrossRefPubMed
8.
Zurück zum Zitat Zhang F, Li C, Zhang J, Guo H, Wu D. Comparison of quantitative computed tomography analysis and single-indicator thermodilution to measure pulmonary edema in patients with acute respiratory distress syndrome. BioMed Eng Online. 2014;13:30.CrossRefPubMedPubMedCentral Zhang F, Li C, Zhang J, Guo H, Wu D. Comparison of quantitative computed tomography analysis and single-indicator thermodilution to measure pulmonary edema in patients with acute respiratory distress syndrome. BioMed Eng Online. 2014;13:30.CrossRefPubMedPubMedCentral
9.
Zurück zum Zitat Lichtenstein D. BLUE-protocol and FALLS-protocol: two applications of lung ultrasound in the critically ill. Chest. 2015;147;1659–70.CrossRefPubMed Lichtenstein D. BLUE-protocol and FALLS-protocol: two applications of lung ultrasound in the critically ill. Chest. 2015;147;1659–70.CrossRefPubMed
10.
Zurück zum Zitat Agricola E, Bove T, Oppizzi M, et al. Ultrasound comet-tail images: a marker of pulmonary edema. A comparative study with wedge pressure and extravascular lung water. Chest. 2005;127:1690–5.CrossRefPubMed Agricola E, Bove T, Oppizzi M, et al. Ultrasound comet-tail images: a marker of pulmonary edema. A comparative study with wedge pressure and extravascular lung water. Chest. 2005;127:1690–5.CrossRefPubMed
11.
Zurück zum Zitat Picano E, Frassi F, Agricola E, et al. Ultrasound lung comets: a clinically useful sign of extravascular lung water. J Am Soc Echocardiogr 2006;19:356–63.CrossRef Picano E, Frassi F, Agricola E, et al. Ultrasound lung comets: a clinically useful sign of extravascular lung water. J Am Soc Echocardiogr 2006;19:356–63.CrossRef
12.
Zurück zum Zitat Michard F. A sneak peek into digital innovations and wearable sensors for cardiac monitoring. J Clin Monit Comput. 2017;31:253–9.CrossRefPubMed Michard F. A sneak peek into digital innovations and wearable sensors for cardiac monitoring. J Clin Monit Comput. 2017;31:253–9.CrossRefPubMed
13.
Zurück zum Zitat Keren H, Burkhoff D, Squara P. Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance. Am J Physiol Heart Circ Physiol. 2007;293:H583-9.CrossRefPubMed Keren H, Burkhoff D, Squara P. Evaluation of a noninvasive continuous cardiac output monitoring system based on thoracic bioreactance. Am J Physiol Heart Circ Physiol. 2007;293:H583-9.CrossRefPubMed
15.
Zurück zum Zitat Kossari N, Hufnagel G, Squara P. Bioreactance: a new tool for cardiac output and thoracic fluid content monitoring during hemodialysis. Hemodial Int. 2009;13:512–7.CrossRefPubMed Kossari N, Hufnagel G, Squara P. Bioreactance: a new tool for cardiac output and thoracic fluid content monitoring during hemodialysis. Hemodial Int. 2009;13:512–7.CrossRefPubMed
16.
Zurück zum Zitat Abraham WT, Stevenson LW, Bourge RC, et al. Sustained efficacy of pulmonary artery pressure to guide adjustment of chronic heart failure therapy: complete follow-up results from the CHAMPION randomized trial. Lancet 2016;387:453–61.CrossRefPubMed Abraham WT, Stevenson LW, Bourge RC, et al. Sustained efficacy of pulmonary artery pressure to guide adjustment of chronic heart failure therapy: complete follow-up results from the CHAMPION randomized trial. Lancet 2016;387:453–61.CrossRefPubMed
17.
Zurück zum Zitat Amir O, Azzam ZS, Gaspar T, et al. Validation of remote dielectric sensing (ReDS) technology for quantification of lung fluid status: comparison to high resolution chest computed tomography in patients with and without acute heart failure. Int J Cardiol. 2016;221:841–6.CrossRefPubMed Amir O, Azzam ZS, Gaspar T, et al. Validation of remote dielectric sensing (ReDS) technology for quantification of lung fluid status: comparison to high resolution chest computed tomography in patients with and without acute heart failure. Int J Cardiol. 2016;221:841–6.CrossRefPubMed
18.
Zurück zum Zitat Amir O, Ben-Gal T, Weinstein JM, et al. Evaluation of remote dielectric sensing (ReDS) technology-guided therapy for decreasing heart failure re-hospitalizations. Int J Cardiol. 2017;240:279–84.CrossRefPubMed Amir O, Ben-Gal T, Weinstein JM, et al. Evaluation of remote dielectric sensing (ReDS) technology-guided therapy for decreasing heart failure re-hospitalizations. Int J Cardiol. 2017;240:279–84.CrossRefPubMed
Metadaten
Titel
Lung water assessment: from gravimetry to wearables
verfasst von
Frederic Michard
Publikationsdatum
11.05.2018
Verlag
Springer Netherlands
Erschienen in
Journal of Clinical Monitoring and Computing / Ausgabe 1/2019
Print ISSN: 1387-1307
Elektronische ISSN: 1573-2614
DOI
https://doi.org/10.1007/s10877-018-0154-z

Weitere Artikel der Ausgabe 1/2019

Journal of Clinical Monitoring and Computing 1/2019 Zur Ausgabe

Update AINS

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.