Skip to main content
Erschienen in: Skeletal Radiology 12/2017

19.08.2017 | Scientific Article

Magnetic resonance cinematography of the fingers: a 3.0 Tesla feasibility study with comparison of incremental and continuous dynamic protocols

verfasst von: Thomas Bayer, Werner Adler, Rolf Janka, Michael Uder, Frank Roemer

Erschienen in: Skeletal Radiology | Ausgabe 12/2017

Einloggen, um Zugang zu erhalten

Abstract

Objective

To study the feasibility of magnetic resonance cinematography of the fingers (MRCF) with comparison of image quality of different protocols for depicting the finger anatomy during motion.

Materials and methods

MRCF was performed during a full flexion and extension movement in 14 healthy volunteers using a finger-gating device. Three real-time sequences (frame rates 17–59 images/min) and one proton density (PD) sequence (3 images/min) were acquired during incremental and continuous motion. Analyses were performed independently by three readers. Qualitative image analysis included Likert-scale grading from 0 (useless) to 5 (excellent) and specific visual analog scale (VAS) grading from 0 (insufficient) to 100 (excellent). Signal-to-noise calculation was performed. Overall percentage agreement and mean absolute disagreement were calculated.

Results

Within the real-time sequences a high frame-rate true fast imaging with steady-state free precession (TRUFI) yielded the best image quality with Likert and overall VAS scores of 3.0 ± 0.2 and 60.4 ± 25.3, respectively. The best sequence regarding image quality was an incremental PD with mean values of 4.8 ± 0.2 and 91.2 ± 9.4, respectively. Overall percentage agreement and mean absolute disagreement were 47.9 and 0.7, respectively. No statistically significant SNR differences were found between continuous and incremental motion for the real-time protocols.

Conclusion

MRCF is feasible with appropriate image quality during continuous motion using a finger-gating device. Almost perfect image quality is achievable with incremental PD imaging, which represents a compromise for MRCF with the drawback of prolonged scanning time.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
1.
Zurück zum Zitat Shellock FG, Mink JH, Deutsch A, Pressman BD. Kinematic magnetic resonance imaging of the joints: techniques and clinical applications. Magn Reson Q. 1991;7(2):104–35.PubMed Shellock FG, Mink JH, Deutsch A, Pressman BD. Kinematic magnetic resonance imaging of the joints: techniques and clinical applications. Magn Reson Q. 1991;7(2):104–35.PubMed
2.
Zurück zum Zitat Quick HH, Ladd ME, Hoevel M, Bosk S, Debatin JF, Laub G, et al. Real-time MRI of joint movement with trueFISP. J Magn Reson Imaging. 2002;15(6):710–5.CrossRefPubMed Quick HH, Ladd ME, Hoevel M, Bosk S, Debatin JF, Laub G, et al. Real-time MRI of joint movement with trueFISP. J Magn Reson Imaging. 2002;15(6):710–5.CrossRefPubMed
3.
Zurück zum Zitat Shellock FG, Mink JH, Deutsch AL, Foo TK, Sullenberger P. Patellofemoral joint: identification of abnormalities with active-movement, “unloaded” versus “loaded” kinematic MR imaging techniques. Radiology. 1993;188(2):575–8.CrossRefPubMed Shellock FG, Mink JH, Deutsch AL, Foo TK, Sullenberger P. Patellofemoral joint: identification of abnormalities with active-movement, “unloaded” versus “loaded” kinematic MR imaging techniques. Radiology. 1993;188(2):575–8.CrossRefPubMed
4.
Zurück zum Zitat Muhle C, Brinkmann G, Brossmann J, Wesner F, Heller M. Kinematic MR imaging of the ankle—initial results with ultra-fast sequence imaging. Acta Radiol. 1997;38(5):885–9.CrossRefPubMed Muhle C, Brinkmann G, Brossmann J, Wesner F, Heller M. Kinematic MR imaging of the ankle—initial results with ultra-fast sequence imaging. Acta Radiol. 1997;38(5):885–9.CrossRefPubMed
5.
Zurück zum Zitat Boutin RD, Buonocore MH, Immerman I, Ashwell Z, Sonico GJ, Szabo RM, et al. Real-time magnetic resonance imaging (MRI) during active wrist motion—initial observations. PLoS One. 2013;8(12):e84004.CrossRefPubMedPubMedCentral Boutin RD, Buonocore MH, Immerman I, Ashwell Z, Sonico GJ, Szabo RM, et al. Real-time magnetic resonance imaging (MRI) during active wrist motion—initial observations. PLoS One. 2013;8(12):e84004.CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Nordmeyer-Massner JA, Pruessmann KP, Wyss M, Manoliu A, Hodler J, Andreisek G, et al. MR imaging of healthy knees in varying degrees of flexion using a stretchable coil array provides comparable image quality compared to a standard knee coil array. Eur J Radiol. 2016;85(3):518–23.CrossRefPubMed Nordmeyer-Massner JA, Pruessmann KP, Wyss M, Manoliu A, Hodler J, Andreisek G, et al. MR imaging of healthy knees in varying degrees of flexion using a stretchable coil array provides comparable image quality compared to a standard knee coil array. Eur J Radiol. 2016;85(3):518–23.CrossRefPubMed
7.
Zurück zum Zitat Tempelaere C, Pierrart J, Lefevre-Colau MM, Vuillemin V, Cuenod CA, Hansen U, et al. Dynamic three-dimensional shoulder MRI during active motion for investigation of rotator cuff diseases. PLoS One. 2016;11(7):e0158563.CrossRefPubMedPubMedCentral Tempelaere C, Pierrart J, Lefevre-Colau MM, Vuillemin V, Cuenod CA, Hansen U, et al. Dynamic three-dimensional shoulder MRI during active motion for investigation of rotator cuff diseases. PLoS One. 2016;11(7):e0158563.CrossRefPubMedPubMedCentral
8.
Zurück zum Zitat Bayer T, Schweizer A, Muller-Gerbl M, Bongartz G. Proximal interphalangeal joint volar plate configuration in the crimp grip position. J Hand Surg Am. 2012;37(5):899–905.CrossRefPubMed Bayer T, Schweizer A, Muller-Gerbl M, Bongartz G. Proximal interphalangeal joint volar plate configuration in the crimp grip position. J Hand Surg Am. 2012;37(5):899–905.CrossRefPubMed
9.
Zurück zum Zitat Bayer T, Adler W, Schweizer A, Schoffl I, Uder M, Janka R. Evaluation of finger A3 pulley rupture in the crimp grip position-a magnetic resonance imaging cadaver study. Skelet Radiol. 2015;44(9):1279–85.CrossRef Bayer T, Adler W, Schweizer A, Schoffl I, Uder M, Janka R. Evaluation of finger A3 pulley rupture in the crimp grip position-a magnetic resonance imaging cadaver study. Skelet Radiol. 2015;44(9):1279–85.CrossRef
10.
Zurück zum Zitat Klauser A, Frauscher F, Bodner G, Halpern EJ, Schocke MF, Springer P, et al. Finger pulley injuries in extreme rock climbers: depiction with dynamic US. Radiology. 2002;222(3):755–61.CrossRefPubMed Klauser A, Frauscher F, Bodner G, Halpern EJ, Schocke MF, Springer P, et al. Finger pulley injuries in extreme rock climbers: depiction with dynamic US. Radiology. 2002;222(3):755–61.CrossRefPubMed
11.
Zurück zum Zitat Saito S, Suzuki Y. Biomechanics of the volar plate of the proximal interphalangeal joint: a dynamic ultrasonographic study. J Hand Surg Am. 2011;36(2):265–71.CrossRefPubMed Saito S, Suzuki Y. Biomechanics of the volar plate of the proximal interphalangeal joint: a dynamic ultrasonographic study. J Hand Surg Am. 2011;36(2):265–71.CrossRefPubMed
12.
Zurück zum Zitat Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF. MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study. Radiology. 2001;219(1):264–9.CrossRefPubMed Barkhausen J, Ruehm SG, Goyen M, Buck T, Laub G, Debatin JF. MR evaluation of ventricular function: true fast imaging with steady-state precession versus fast low-angle shot cine MR imaging: feasibility study. Radiology. 2001;219(1):264–9.CrossRefPubMed
13.
Zurück zum Zitat Abolmaali ND, Schmitt J, Schwarz W, Toll DE, Hinterwimmer S, Vogl TJ. Visualization of the articular disk of the temporomandibular joint in near-real-time MRI: feasibility study. Eur Radiol. 2004;14(10):1889–94.CrossRefPubMed Abolmaali ND, Schmitt J, Schwarz W, Toll DE, Hinterwimmer S, Vogl TJ. Visualization of the articular disk of the temporomandibular joint in near-real-time MRI: feasibility study. Eur Radiol. 2004;14(10):1889–94.CrossRefPubMed
14.
Zurück zum Zitat Morales H, Cornelius R. Imaging approach to Temporomandibular joint disorders. Clin Neuroradiol. 2016;26(1):5–22.CrossRefPubMed Morales H, Cornelius R. Imaging approach to Temporomandibular joint disorders. Clin Neuroradiol. 2016;26(1):5–22.CrossRefPubMed
15.
Zurück zum Zitat Tomas X, Pomes J, Berenguer J, Quinto L, Nicolau C, Mercader JM, et al. MR imaging of temporomandibular joint dysfunction: a pictorial review. Radiographics. 2006;26(3):765–81.CrossRefPubMed Tomas X, Pomes J, Berenguer J, Quinto L, Nicolau C, Mercader JM, et al. MR imaging of temporomandibular joint dysfunction: a pictorial review. Radiographics. 2006;26(3):765–81.CrossRefPubMed
16.
Zurück zum Zitat Tomas X, Pomes J, Berenguer J, Mercader JM, Pons F, Donoso L. Temporomandibular joint soft-tissue pathology, II: nondisc abnormalities. Semin Ultrasound CT MR. 2007;28(3):205–12.CrossRefPubMed Tomas X, Pomes J, Berenguer J, Mercader JM, Pons F, Donoso L. Temporomandibular joint soft-tissue pathology, II: nondisc abnormalities. Semin Ultrasound CT MR. 2007;28(3):205–12.CrossRefPubMed
17.
Zurück zum Zitat Lasalarie JC, Serfaty JM, Carre C, Messika-Zeitoun D, Jeannot C, Schouman-Claeys E, et al. Accuracy of contrast-enhanced cine-MR sequences in the assessment of left ventricular function: comparison with precontrast cine-MR sequences. Results of a bicentric study. Eur Radiol. 2007;17(11):2838–44.CrossRefPubMed Lasalarie JC, Serfaty JM, Carre C, Messika-Zeitoun D, Jeannot C, Schouman-Claeys E, et al. Accuracy of contrast-enhanced cine-MR sequences in the assessment of left ventricular function: comparison with precontrast cine-MR sequences. Results of a bicentric study. Eur Radiol. 2007;17(11):2838–44.CrossRefPubMed
18.
Zurück zum Zitat Grothues F, Boenigk H, Graessner J, Kanowski M, Klein HU. Balanced steady-state free precession vs segmented fast low-angle shot for the evaluation of ventricular volumes, mass, and function at 3 Tesla. J Magn Reson Imaging. 2007;26(2):392–400.CrossRefPubMed Grothues F, Boenigk H, Graessner J, Kanowski M, Klein HU. Balanced steady-state free precession vs segmented fast low-angle shot for the evaluation of ventricular volumes, mass, and function at 3 Tesla. J Magn Reson Imaging. 2007;26(2):392–400.CrossRefPubMed
Metadaten
Titel
Magnetic resonance cinematography of the fingers: a 3.0 Tesla feasibility study with comparison of incremental and continuous dynamic protocols
verfasst von
Thomas Bayer
Werner Adler
Rolf Janka
Michael Uder
Frank Roemer
Publikationsdatum
19.08.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
Skeletal Radiology / Ausgabe 12/2017
Print ISSN: 0364-2348
Elektronische ISSN: 1432-2161
DOI
https://doi.org/10.1007/s00256-017-2742-2

Weitere Artikel der Ausgabe 12/2017

Skeletal Radiology 12/2017 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.