01.03.2018 | Original Article | Ausgabe 2/2018

Clinical Oral Investigations 2/2018

Mechanical performance of cement– and screw–retained all–ceramic single crowns on dental implants

Zeitschrift:
Clinical Oral Investigations > Ausgabe 2/2018
Autoren:
Matthias Obermeier, Oliver Ristow, Kurt Erdelt, Florian Beuer

Abstract

Objectives

This in-vitro study was performed to compare the contact wear, fracture strength and failure mode of implant-supported all-ceramic single crowns manufactured with various fabrication and fixation concepts.

Materials and methods

Fifty dental implants (Conelog Ø 4,3mm/L11mm, Camlog Biotechnologies AG) were embedded and treated with all-ceramic molar single-crowns. Three groups received hand-layered zirconia crowns (IPS e.max Ceram/ IPS e.max ZirCAD, Ivoclar Vivadent AG): CZL (cement-retained zirconia-based layered) group crowns were cemented conventionally, SZL (screw-retained zirconia-based layered) group crowns were screw-retained, MZL (modified zirconia-based layered) group crowns showed a different coping design with screw retention. The specimens of SST (screw-retained sintering-technique) and SFL (screw-retained full-contour lithium-disilicate) group were CAD/CAM (Computer-aided design/computer-aided manufacturing) fabricated in the sintering technique (IPS e.max ZirCAD/IPS e.max CAD, Ivoclar Vivadent AG) and full-contour of lithium disilicate (IPS e.max CAD, Ivoclar Vivadent AG) respectively and screw-retained. All specimens underwent artificial aging, load until failure and a scanning electron microscopy (SEM) analysis. The received data were statistically compared (one-way ANOVA; Student-Newman-Keuls test; Mann-Whitney U-test) at a significance level of 5%.

Results

Mouth-motion fatigue testing caused two abutment fractures (SST group and SZL group) and two chipping events (CZL group). Specimens of MZL group showed statistically significant less contact wear compared to the other groups (p<0.001). There was no statistical difference between the groups in terms of the maximum fracture load. SEM-analysis showed a more homogenous structure and surface of CAD/CAM fabricated specimens towards manually veneered components.

Conclusions

The mode of retention did not influence the fracture resistance but the failure patterns of the specimens. CAD/CAM milled lithium-disilicate crowns seemed to be a preserving factor for dental implants.

Clinical relevance

The mode of retention and veneering influences the mechanical performance of implant-supported single crowns.

Bitte loggen Sie sich ein, um Zugang zu diesem Inhalt zu erhalten

★ PREMIUM-INHALT
e.Med Interdisziplinär

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de. Zusätzlich können Sie eine Zeitschrift Ihrer Wahl in gedruckter Form beziehen – ohne Aufpreis.

Weitere Produktempfehlungen anzeigen
Literatur
Über diesen Artikel

Weitere Artikel der Ausgabe 2/2018

Clinical Oral Investigations 2/2018 Zur Ausgabe
  1. Das kostenlose Testabonnement läuft nach 14 Tagen automatisch und formlos aus. Dieses Abonnement kann nur einmal getestet werden.

Neu im Fachgebiet Zahnmedizin

Mail Icon II Newsletter

Bestellen Sie unseren kostenlosen Newsletter Update Zahnmedizin und bleiben Sie gut informiert – ganz bequem per eMail.

Bildnachweise