20.07.2017 | Technical Note

Methods for optimizing the display conditions of brain magnetic resonance images

verfasst von: Toshimasa Hara, Yusuke Inoue, Ryutaro Ukisu, Hirofumi Hata

Erschienen in: Japanese Journal of Radiology | Ausgabe 10/2017

Einloggen, um Zugang zu erhalten

Abstract

Purpose

To investigate a method for optimizing the display conditions of brain magnetic resonance (MR) images.

Materials and methods

We retrospectively analyzed brain MR images of 120 adults classified into screening, acute cerebral infarction, and brain tumor groups (n = 40 each). Two observers independently displayed the images on a monitor and optimized the display conditions using the W/L and U/L methods. In the W/L method, the observers manipulated the width and level of the display window, while in the U/L method they manipulated the upper and lower levels of the window. The times required were compared between the two methods. Additionally, the appropriateness of the determined window setting was evaluated visually by the respective observer to exclude the possibility that rough, suboptimal adjustment shortened the adjustment time.

Results

For both observers and all groups, the time required for optimization was significantly shorter for the U/L method than for the W/L method. The appropriateness of the window setting for the U/L method was equal to or better than that for the W/L method.

Conclusion

Manipulating the upper and lower levels of the display window appears to improve the efficiency of interpreting brain MR images through rapid optimization of the display condition.
Literatur
1.
Zurück zum Zitat Pomerantz SM, White CS, Krebs TL, Daly B, Sukumar SA, Hooper F, et al. Liver and bone window settings for soft-copy interpretation of chest and abdominal CT. AJR Am J Roentgenol. 2000;174:311–4.CrossRefPubMed Pomerantz SM, White CS, Krebs TL, Daly B, Sukumar SA, Hooper F, et al. Liver and bone window settings for soft-copy interpretation of chest and abdominal CT. AJR Am J Roentgenol. 2000;174:311–4.CrossRefPubMed
2.
Zurück zum Zitat Lamba R, McGahan JP, Corwin MT, Li CS, Tran T, Seibert JA, et al. CT Hounsfield numbers of soft tissues on unenhanced abdominal CT scans: variability between two different manufacturers’ MDCT scanners. AJR Am J Roentgenol. 2014;203:1013–20.CrossRefPubMedPubMedCentral Lamba R, McGahan JP, Corwin MT, Li CS, Tran T, Seibert JA, et al. CT Hounsfield numbers of soft tissues on unenhanced abdominal CT scans: variability between two different manufacturers’ MDCT scanners. AJR Am J Roentgenol. 2014;203:1013–20.CrossRefPubMedPubMedCentral
3.
Zurück zum Zitat Nyúl LG, Udupa JK. On standardizing the MR image intensity scale. Magn Reson Med. 1999;42:1072–81.CrossRefPubMed Nyúl LG, Udupa JK. On standardizing the MR image intensity scale. Magn Reson Med. 1999;42:1072–81.CrossRefPubMed
4.
Zurück zum Zitat Robitaille N, Mouiha A, Crépeault B, Valdivia F, Duchesne S. The Alzheimer’s disease neuroimaging initiative. Tissue-based MRI intensity standardization: application to multicentric datasets. Int J Biomed Imaging. 2012;2012:347120.PubMedPubMedCentral Robitaille N, Mouiha A, Crépeault B, Valdivia F, Duchesne S. The Alzheimer’s disease neuroimaging initiative. Tissue-based MRI intensity standardization: application to multicentric datasets. Int J Biomed Imaging. 2012;2012:347120.PubMedPubMedCentral
5.
Zurück zum Zitat Sasaki M, Ida M, Yamada K, Watanabe Y, Matsui M. Standardizing display conditions of diffusion-weighted images using concurrent b0 images: a multi-vendor multi-institutional study. Magn Reson Med Sci. 2007;6:133–7.CrossRefPubMed Sasaki M, Ida M, Yamada K, Watanabe Y, Matsui M. Standardizing display conditions of diffusion-weighted images using concurrent b0 images: a multi-vendor multi-institutional study. Magn Reson Med Sci. 2007;6:133–7.CrossRefPubMed
6.
Zurück zum Zitat Hirai T, Sasaki M, Maeda M, Ida M, Katsuragawa S, Sakoh M, et al. Diffusion-weighted imaging in ischemic stroke: effect of display method on observers’ diagnostic performance. Acad Radiol. 2009;16:305–12.CrossRefPubMed Hirai T, Sasaki M, Maeda M, Ida M, Katsuragawa S, Sakoh M, et al. Diffusion-weighted imaging in ischemic stroke: effect of display method on observers’ diagnostic performance. Acad Radiol. 2009;16:305–12.CrossRefPubMed
7.
Zurück zum Zitat Nagashima H, Doi K, Ogura T, Fujita H. Automated adjustment of display conditions in brain MR images: diffusion-weighted MRIs and apparent diffusion coefficient maps for hyperacute ischemic stroke. Radiol Phys Technol. 2013;6:202–9.CrossRefPubMed Nagashima H, Doi K, Ogura T, Fujita H. Automated adjustment of display conditions in brain MR images: diffusion-weighted MRIs and apparent diffusion coefficient maps for hyperacute ischemic stroke. Radiol Phys Technol. 2013;6:202–9.CrossRefPubMed
8.
Zurück zum Zitat Gillespy T 3rd, Rowberg AH. Displaying radiologic images on personal computers. J Digit Imaging. 1993;6:151–63.CrossRefPubMed Gillespy T 3rd, Rowberg AH. Displaying radiologic images on personal computers. J Digit Imaging. 1993;6:151–63.CrossRefPubMed
10.
Zurück zum Zitat Wheaton AJ, Miyazaki M. Non-contrast enhanced MR angiography: physical principles. J Magn Reson Imaging. 2012;36:286–304.CrossRefPubMed Wheaton AJ, Miyazaki M. Non-contrast enhanced MR angiography: physical principles. J Magn Reson Imaging. 2012;36:286–304.CrossRefPubMed
Metadaten
Titel
Methods for optimizing the display conditions of brain magnetic resonance images
verfasst von
Toshimasa Hara
Yusuke Inoue
Ryutaro Ukisu
Hirofumi Hata
Publikationsdatum
20.07.2017
Verlag
Springer Japan
Erschienen in
Japanese Journal of Radiology / Ausgabe 10/2017
Print ISSN: 1867-1071
Elektronische ISSN: 1867-108X
DOI
https://doi.org/10.1007/s11604-017-0669-0

Weitere Artikel der Ausgabe 10/2017

Japanese Journal of Radiology 10/2017 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.