Abstract

Purpose

The aim of the study was to validate a minimally invasive, multi-port approach to the internal auditory canal at the lateral skull base on a cadaver specimen.

Methods

Fiducials and a custom baseplate were fixed on a cadaver skull, and a computed tomography image was acquired. Three trajectories from the mastoid surface to the internal auditory canal were computed with a custom planning tool. A self-developed positioning system with a drill guide was attached to the baseplate. After referencing on a high precision coordinate measuring machine, the drill guide was aligned according to the planned trajectories. Drilling of three trajectories was performed with a medical stainless steel drill bit.

Results

The process of planning and drilling three trajectories to the internal auditory canal with the presented workflow and tools was successful. The mean drilling error of the system (Euclidian distance between the planned trajectory and centerline of the actual drilled canal) was \(0.53 \pm 0.12\) mm at the entry point and \(1.01\pm 0.39\) mm at the target. The inaccuracy of the drill process itself and its physical limitations were identified as the main contributing factors.

Conclusion

The presented system allows the planning and drilling of multiple minimally invasive canals at the lateral skull base. Further studies are required to reduce the drilling error and evaluate the clinical application of the system.
Literatur
1.
Zurück zum Zitat Schipper J, Klenzner T, Aschendorff A, Arapakis I, Ridder GJ, Laszig R (2004) Navigation-controlled cochleostomy. Is an improvement in the quality of results for cochlear implant surgery possible? HNO 52(4):329–335 Schipper J, Klenzner T, Aschendorff A, Arapakis I, Ridder GJ, Laszig R (2004) Navigation-controlled cochleostomy. Is an improvement in the quality of results for cochlear implant surgery possible? HNO 52(4):329–335
2.
Zurück zum Zitat Sauerland S, Jaschinski Neugebauer EA (2010) Laparoscopic versus open surgery for suspected appendicitis. Cochrane Database Syst Rev 10:CD001546 Sauerland S, Jaschinski Neugebauer EA (2010) Laparoscopic versus open surgery for suspected appendicitis. Cochrane Database Syst Rev 10:CD001546
3.
Zurück zum Zitat Keus F, de Jong JA, Gooszen HG, van Laarhoven CJ (2006) Laparoscopic versus open cholecystectomy for patients with symptomatic cholecystolithiasis. Cochrane Database Syst Rev 4:CD006231 Keus F, de Jong JA, Gooszen HG, van Laarhoven CJ (2006) Laparoscopic versus open cholecystectomy for patients with symptomatic cholecystolithiasis. Cochrane Database Syst Rev 4:CD006231
4.
Zurück zum Zitat Majdani O, Rau TS, Baron S, Eilers H, Baier C, Heimann B, Ortmaier T, Bartling S, Lenarz T, Leinung M (2009) A robot-guided minimally invasive approach for cochlear implant surgery: preliminary results of a temporal bone study. Int J Comput Assist Radiol Surg 4:475–486CrossRefPubMed Majdani O, Rau TS, Baron S, Eilers H, Baier C, Heimann B, Ortmaier T, Bartling S, Lenarz T, Leinung M (2009) A robot-guided minimally invasive approach for cochlear implant surgery: preliminary results of a temporal bone study. Int J Comput Assist Radiol Surg 4:475–486CrossRefPubMed
5.
Zurück zum Zitat Bell B, Gerber N, Williamson T, Gavaghan K, Wimmer W, Caversaccio M, Weber S (2013) In vitro accuracy evaluation of image-guided robot system for direct cochlear access. Otol Neurotol 34:1284–1290CrossRefPubMed Bell B, Gerber N, Williamson T, Gavaghan K, Wimmer W, Caversaccio M, Weber S (2013) In vitro accuracy evaluation of image-guided robot system for direct cochlear access. Otol Neurotol 34:1284–1290CrossRefPubMed
6.
Zurück zum Zitat Labadie RF, Balachandran R, Noble JH, Blachon GS, Mitchell JE, Reda FA, Dawant BM, Fitzpatrick JM (2014) Minimally invasive image-guided cochlear implantation surgery: first report of clinical implementation. Laryngoscope 124:1915–1922CrossRefPubMedPubMedCentral Labadie RF, Balachandran R, Noble JH, Blachon GS, Mitchell JE, Reda FA, Dawant BM, Fitzpatrick JM (2014) Minimally invasive image-guided cochlear implantation surgery: first report of clinical implementation. Laryngoscope 124:1915–1922CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Wanna GB, Balachandran R, Majdani O, Mitchell J, Labadie RF (2009) Percutaneous access to the petrous apex in vitro using customized micro-stereotactic frames based on image-guided surgical technology. Acta Otolaryngol 25:1–6CrossRef Wanna GB, Balachandran R, Majdani O, Mitchell J, Labadie RF (2009) Percutaneous access to the petrous apex in vitro using customized micro-stereotactic frames based on image-guided surgical technology. Acta Otolaryngol 25:1–6CrossRef
8.
Zurück zum Zitat Kobler JP, Nuelle K, Lexow GJ, Rau TS, Majdani O, Kahrs LA, Kotlarski J, Ortmaier T (2016) Configuration optimization and experimental accuracy evaluation of a bone-attached, parallel robot for skull surgery. Int J Comput Assist Radiol Surg 11(3):421–436CrossRefPubMed Kobler JP, Nuelle K, Lexow GJ, Rau TS, Majdani O, Kahrs LA, Kotlarski J, Ortmaier T (2016) Configuration optimization and experimental accuracy evaluation of a bone-attached, parallel robot for skull surgery. Int J Comput Assist Radiol Surg 11(3):421–436CrossRefPubMed
9.
Zurück zum Zitat Stenin I, Hansen S, Becker M, Sakas G, Fellner D, Klenzner T, Schipper J (2014) Minimally invasive multiport surgery of the lateral skull base. Biomed Res Int 2014:379295CrossRefPubMedPubMedCentral Stenin I, Hansen S, Becker M, Sakas G, Fellner D, Klenzner T, Schipper J (2014) Minimally invasive multiport surgery of the lateral skull base. Biomed Res Int 2014:379295CrossRefPubMedPubMedCentral
10.
Zurück zum Zitat Yushkevich PA, Piven J, Hazlett HC, Smith RG, Ho S, Gee JC, Gerig G (2006) User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage 31(3):1116–1128CrossRefPubMed Yushkevich PA, Piven J, Hazlett HC, Smith RG, Ho S, Gee JC, Gerig G (2006) User-guided 3D active contour segmentation of anatomical structures: significantly improved efficiency and reliability. Neuroimage 31(3):1116–1128CrossRefPubMed
11.
Zurück zum Zitat Lorensen WE, Cline HE (1987) Marching cubes: a high resolution 3D surface construction algorithm. ACM Siggraph Comput Gr 21(4):163–169CrossRef Lorensen WE, Cline HE (1987) Marching cubes: a high resolution 3D surface construction algorithm. ACM Siggraph Comput Gr 21(4):163–169CrossRef
12.
Zurück zum Zitat Kratchman LB, Fitzpatrick JM (2013) Robotically-adjustable microstereotactic frames for image-guided neurosurgery. In: Proceedings of the SPIE 8671, medical imaging, image-guided procedures. Robotic interventions, and modeling, p 86711U. doi:10.1117/12.2008172 Kratchman LB, Fitzpatrick JM (2013) Robotically-adjustable microstereotactic frames for image-guided neurosurgery. In: Proceedings of the SPIE 8671, medical imaging, image-guided procedures. Robotic interventions, and modeling, p 86711U. doi:10.​1117/​12.​2008172
13.
Zurück zum Zitat Balachandran R, Mitchell JE, Blachon G, Noble JH, Dawant BM, Fitzpatrick JM, Labadie RF (2010) Percutaneous cochlear implant drilling via customized frames: an in vitro study. Otolaryngol Head Neck Surg 142:421–426CrossRefPubMedPubMedCentral Balachandran R, Mitchell JE, Blachon G, Noble JH, Dawant BM, Fitzpatrick JM, Labadie RF (2010) Percutaneous cochlear implant drilling via customized frames: an in vitro study. Otolaryngol Head Neck Surg 142:421–426CrossRefPubMedPubMedCentral
14.
Zurück zum Zitat Kahrs LA, McRackan TR, Labadie RF (2011) Intracochlear visualization: comparing established and novel endoscopy techniques. Otol Neurotol 32(9):1590–1595 Kahrs LA, McRackan TR, Labadie RF (2011) Intracochlear visualization: comparing established and novel endoscopy techniques. Otol Neurotol 32(9):1590–1595
15.
Zurück zum Zitat Kobler JP, Prielozny L, Lexow GJ, Rau TS, Majdani O, Ortmaier T (2015) Mechanical characterization of bone anchors used with a bone-attached, parallel robot for skull surgery. Med Eng Phys 37(5):460–468CrossRefPubMed Kobler JP, Prielozny L, Lexow GJ, Rau TS, Majdani O, Ortmaier T (2015) Mechanical characterization of bone anchors used with a bone-attached, parallel robot for skull surgery. Med Eng Phys 37(5):460–468CrossRefPubMed
16.
Zurück zum Zitat Nau-Hermes M (2014) Ein messtechnischer beurteilungsansatz für das verletzungsrisiko anatomischer strukturen bei bildgestützten minimalinvasiven eingriffen. Apprimus Wissenschaftsverlag, Aachen Nau-Hermes M (2014) Ein messtechnischer beurteilungsansatz für das verletzungsrisiko anatomischer strukturen bei bildgestützten minimalinvasiven eingriffen. Apprimus Wissenschaftsverlag, Aachen
17.
Zurück zum Zitat Labadie RF, Davis BM, Fitzpatrick JM (2005) Image-guided surgery: what is the accuracy? Curr Opin Otolaryngol Head Neck Surg 13:27–31CrossRefPubMed Labadie RF, Davis BM, Fitzpatrick JM (2005) Image-guided surgery: what is the accuracy? Curr Opin Otolaryngol Head Neck Surg 13:27–31CrossRefPubMed
18.
Zurück zum Zitat Dillon NP, Kratchman LB, Dietrich MS, Labadie RF, Webster RJ 3rd, Withrow TJ (2013) An experimental evaluation of the force requirements for robotic mastoidectomy. Otol Neurotol 34:e93CrossRefPubMedPubMedCentral Dillon NP, Kratchman LB, Dietrich MS, Labadie RF, Webster RJ 3rd, Withrow TJ (2013) An experimental evaluation of the force requirements for robotic mastoidectomy. Otol Neurotol 34:e93CrossRefPubMedPubMedCentral
19.
Zurück zum Zitat Kobler JP, Schoppe M, Lexow GJ, Rau TS, Majdani O, Kahrs LA, Ortmaier T (2014) Temporal bone borehole accuracy for cochlear implantation influenced by drilling strategy: an in vitro study. Int J Comput Assist Radiol Surg 9(6):1033–1043CrossRefPubMed Kobler JP, Schoppe M, Lexow GJ, Rau TS, Majdani O, Kahrs LA, Ortmaier T (2014) Temporal bone borehole accuracy for cochlear implantation influenced by drilling strategy: an in vitro study. Int J Comput Assist Radiol Surg 9(6):1033–1043CrossRefPubMed
20.
Zurück zum Zitat Feldmann A, Wandel J, Zysset P (2016) Reducing temperature elevation of robotic bone drilling. Med Eng Phys 38(12):1495–1504CrossRefPubMed Feldmann A, Wandel J, Zysset P (2016) Reducing temperature elevation of robotic bone drilling. Med Eng Phys 38(12):1495–1504CrossRefPubMed
Metadaten
Titel
Minimally invasive, multi-port approach to the lateral skull base: a first in vitro evaluation
verfasst von
Igor Stenin
Stefan Hansen
M. Nau-Hermes
W. El-Hakimi
M. Becker
J. Bredemann
J. Kristin
T. Klenzner
J. Schipper
Publikationsdatum
14.02.2017
Verlag
Springer International Publishing
Erschienen in
International Journal of Computer Assisted Radiology and Surgery / Ausgabe 5/2017
Print ISSN: 1861-6410
Elektronische ISSN: 1861-6429
DOI
https://doi.org/10.1007/s11548-017-1533-5

Weitere Artikel der Ausgabe 5/2017

International Journal of Computer Assisted Radiology and Surgery 5/2017 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.