Skip to main content
Erschienen in: International Orthopaedics 2/2009

01.04.2009 | Original Paper

Minimally invasive percutaneous plate osteosynthesis (MIPPO) technique applied in the treatment of humeral shaft distal fractures through a lateral approach

verfasst von: Fang Ji, Dake Tong, Hao Tang, Xiaobing Cai, Qiulin Zhang, Jingfeng Li, Qiugen Wang

Erschienen in: International Orthopaedics | Ausgabe 2/2009

Einloggen, um Zugang zu erhalten

Abstract

The minimally invasive percutaneous plate osteosynthesis (MIPPO) technique through the anterior approach has been successfully used in the treatment of humeral shaft fractures and has gained satisfactory clinical outcome. An anatomical study and a preliminary clinic report were performed to evaluate the feasibility of applying the MIPPO technique in the treatment of humeral shaft distal fractures through the lateral approach. This study was done on 14 arms from seven fresh cadavers. The results of this study showed that it is possible to treat humeral shaft distal fractures by using the MIPPO technique through the lateral approach. The results of using the MIPPO technique through the lateral approach in the treatment of humeral shaft fractures in 22 patients were also reviewed.
Literatur
1.
Zurück zum Zitat Apivatthakakul T, Arpornchayanon O (2005) Minimally invasive plate osteosynthesis (MIPO) combined with distraction osteogenesis in the treatment of bone defects. A new technique of bone transport: a report of two cases. Injury 36(4):530–538PubMedCrossRef Apivatthakakul T, Arpornchayanon O (2005) Minimally invasive plate osteosynthesis (MIPO) combined with distraction osteogenesis in the treatment of bone defects. A new technique of bone transport: a report of two cases. Injury 36(4):530–538PubMedCrossRef
2.
Zurück zum Zitat Fernandez Dell Oca AA (2002) The principle of helical implants. Unusual ideas worth considering. Injury Suppl 33:19–27 Fernandez Dell Oca AA (2002) The principle of helical implants. Unusual ideas worth considering. Injury Suppl 33:19–27
3.
Zurück zum Zitat Frigg R (2001) Locking compression plate (LCP): an osteosynthesis plate based on the dynamic compression plate and point contact fixator (PCFix). Injury 32(Suppl 2):636 Frigg R (2001) Locking compression plate (LCP): an osteosynthesis plate based on the dynamic compression plate and point contact fixator (PCFix). Injury 32(Suppl 2):636
4.
5.
Zurück zum Zitat Gerwin M, Hotchkiss RN, Weiland AJ (1996) Alternative operative exposures of the posterior aspect of the humeral diaphysis with reference to the radial nerve. J Bone Joint Surg Am 78-A:1690–1695 Gerwin M, Hotchkiss RN, Weiland AJ (1996) Alternative operative exposures of the posterior aspect of the humeral diaphysis with reference to the radial nerve. J Bone Joint Surg Am 78-A:1690–1695
6.
Zurück zum Zitat Heim D, Herkert F, Hess P, Regazzni P (1993) Surgical treatment of humeral shaft fracture: the Basel experience. J Trauma 35:22632CrossRef Heim D, Herkert F, Hess P, Regazzni P (1993) Surgical treatment of humeral shaft fracture: the Basel experience. J Trauma 35:22632CrossRef
7.
Zurück zum Zitat Heitemeyer U, Kemper F, Hierholzer G, Haines J (1987) Severely comminuted femoral shaft fracture: treatment by bridging plate osteosynthesis. Arch Orthop Trauma Surg 106:327–330PubMedCrossRef Heitemeyer U, Kemper F, Hierholzer G, Haines J (1987) Severely comminuted femoral shaft fracture: treatment by bridging plate osteosynthesis. Arch Orthop Trauma Surg 106:327–330PubMedCrossRef
8.
Zurück zum Zitat Helfet DL, Shonnard PY, Levine D, Borrelli J Jr(1997) Minimally invasive plate osteosynthesis of distal fractures of the tibia. Injury 28(Suppl 1):428 Helfet DL, Shonnard PY, Levine D, Borrelli J Jr(1997) Minimally invasive plate osteosynthesis of distal fractures of the tibia. Injury 28(Suppl 1):428
9.
Zurück zum Zitat Henle MB (1993) Humeral shaft fracture. In: Hansen ST, Swiontkowski MF (eds) Orthopedic trauma protocols. Raven Press, New York, pp 91–95 Henle MB (1993) Humeral shaft fracture. In: Hansen ST, Swiontkowski MF (eds) Orthopedic trauma protocols. Raven Press, New York, pp 91–95
10.
Zurück zum Zitat Ji Fang, Yang Tie-yi, Wang Ming-chun et al (2005) Anatomic analysis of MIPPO technique in treatment of humeral fractures: a preliminary clinic report. Chinese J Orthop Trauma 7(12):1128–1131 Ji Fang, Yang Tie-yi, Wang Ming-chun et al (2005) Anatomic analysis of MIPPO technique in treatment of humeral fractures: a preliminary clinic report. Chinese J Orthop Trauma 7(12):1128–1131
11.
Zurück zum Zitat Lau TW, Leung F, Chan CF, Chow SP (2007) Minimally invasive plate osteosynthesis in the treatment of proximal humeral fracture. Int Orthop 31(5):657–664PubMedCrossRef Lau TW, Leung F, Chan CF, Chow SP (2007) Minimally invasive plate osteosynthesis in the treatment of proximal humeral fracture. Int Orthop 31(5):657–664PubMedCrossRef
12.
Zurück zum Zitat Perren SM (2002) The technology of minimally invasive percutaneous osteosynthesis (MIPO). Injury 33(Suppl 1):VI–VIIPubMedCrossRef Perren SM (2002) The technology of minimally invasive percutaneous osteosynthesis (MIPO). Injury 33(Suppl 1):VI–VIIPubMedCrossRef
13.
Zurück zum Zitat Perren SM (2002) Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br 84(8):1093–1110PubMedCrossRef Perren SM (2002) Evolution of the internal fixation of long bone fractures. The scientific basis of biological internal fixation: choosing a new balance between stability and biology. J Bone Joint Surg Br 84(8):1093–1110PubMedCrossRef
14.
Zurück zum Zitat Stoffel K, Dieter U, Stachowiak G, Gachter A, Kuster MS (2003) Biomechanical testing of the LCP-how can stability in locked internal fixators be controlled? Injury 34(Suppl 2):B11–B19PubMedCrossRef Stoffel K, Dieter U, Stachowiak G, Gachter A, Kuster MS (2003) Biomechanical testing of the LCP-how can stability in locked internal fixators be controlled? Injury 34(Suppl 2):B11–B19PubMedCrossRef
15.
Zurück zum Zitat Wagner M (2003) General principles for the clinical use of the LCP. Injury 34(Suppl 2):B31–B42PubMedCrossRef Wagner M (2003) General principles for the clinical use of the LCP. Injury 34(Suppl 2):B31–B42PubMedCrossRef
16.
Zurück zum Zitat Wagner M, Frenk A, Frigg R (2004) New concepts for bone fracture treatment and the locking compression plate. Surg Technol Int 12:271–277PubMed Wagner M, Frenk A, Frigg R (2004) New concepts for bone fracture treatment and the locking compression plate. Surg Technol Int 12:271–277PubMed
17.
Zurück zum Zitat Zhiquan A, Bingfang Z, Yeming W, Chi Z, Peiyan H (2007) Minimally invasive plating osteosynthesis (MIPO) of middle and distal third humeral shaft fractures. J Orthop Trauma 21(9):628–633PubMedCrossRef Zhiquan A, Bingfang Z, Yeming W, Chi Z, Peiyan H (2007) Minimally invasive plating osteosynthesis (MIPO) of middle and distal third humeral shaft fractures. J Orthop Trauma 21(9):628–633PubMedCrossRef
Metadaten
Titel
Minimally invasive percutaneous plate osteosynthesis (MIPPO) technique applied in the treatment of humeral shaft distal fractures through a lateral approach
verfasst von
Fang Ji
Dake Tong
Hao Tang
Xiaobing Cai
Qiulin Zhang
Jingfeng Li
Qiugen Wang
Publikationsdatum
01.04.2009
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 2/2009
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-008-0522-2

Weitere Artikel der Ausgabe 2/2009

International Orthopaedics 2/2009 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.