Skip to main content
Erschienen in: International Orthopaedics 11/2018

24.03.2018 | Original Paper

Minimally invasive plate osteosynthesis in humerus nonunion after intramedullary nailing

verfasst von: Christian Allende, Fernando Vanoli, Luciano Gentile, Natalia Gutierrez

Erschienen in: International Orthopaedics | Ausgabe 11/2018

Einloggen, um Zugang zu erhalten

Abstract

Introduction

The purpose of this study was to evaluate the results achieved after the use of lateral minimally invasive plate osteosynthesis (MIPO) in oligotrophic humerus nonunions resulting from failed intramedullary nailing (IM).

Method

We evaluated nine patients with humerus nonunion after failed locked intramedullary nailing, all treated using 3.5-mm locked compression plates (LCP) placed through lateral minimally invasive approaches, between 2010 and 2016. Patient’s age averaged 39.7 years. All nonunions were diaphyseal and oligotrophic. All nonunions had previous surgical treatment with static locked nails (seven antegrade and two retrograde). The IM nails were all well inserted in the humerus (none of them protruded or had rotator cuff lesions associated). Pre-operative Disabilities of the Arm, Shoulder and Hand (DASH) score averaged 25.5 points. Pre-operative Constant’s score averaged 80.2. Pre-operative visual analog scale of pain averaged 2.4 points.

Results

Follow-up averaged 17.7 months. Time between initial surgery and revision procedure averaged 11.7 months. Union was achieved in all cases, after an average of 4.8 months. DASH score at last follow-up averaged 5.1 points, and final Constant’s score averaged 93.7 points. The analog scale of pain averaged 0.7 points. Time from definitive surgery to work return averaged 3.9 months. Long 3.5-mm LCPs were used (plate length averaged 16.9 screw holes). In two cases, a third 4-cm incision at the nonunion site was performed and cancellous autologous iliac crest bone graft was associated.

Conclusion

In our series of nine patients, we achieved union and good objective and subjective results, with high patient satisfaction, using a lateral MIPO technique and placing long 3.5-mm LCPs in selected oligotrophic humerus nonunions after failed IM nailing.
Literatur
1.
Zurück zum Zitat Brinker MR, O’Connor DP (2007) Exchange nailing of ununited fractures. J Bone Joint Surg Am 89:177–188CrossRef Brinker MR, O’Connor DP (2007) Exchange nailing of ununited fractures. J Bone Joint Surg Am 89:177–188CrossRef
2.
Zurück zum Zitat Ouyang H, Xiong J, Xiang P et al (2013) Plate versus intramedullary nail fixation in the treatment of humeral shaft fractures: an updated meta-analysis. J Shoulder Elb Surg 22:387–395CrossRef Ouyang H, Xiong J, Xiang P et al (2013) Plate versus intramedullary nail fixation in the treatment of humeral shaft fractures: an updated meta-analysis. J Shoulder Elb Surg 22:387–395CrossRef
3.
Zurück zum Zitat Kurup H, Hossain M, Andrew JG (2011) Dynamic compression plating versus locked intramedullary nailing for humeral shaft fractures in adults. Cochrane Database Syst Rev Cochrane Database Syst Rev. (6): CD005959 Kurup H, Hossain M, Andrew JG (2011) Dynamic compression plating versus locked intramedullary nailing for humeral shaft fractures in adults. Cochrane Database Syst Rev Cochrane Database Syst Rev. (6): CD005959
4.
Zurück zum Zitat Gessmann J, Konigshausen M, Coulibaly MO et al (2016) Anterior augmentation plating of aseptic humeral shaft nonunions after intramedullary nailing. Arch Orthop Trauma Surg 136:631–638CrossRef Gessmann J, Konigshausen M, Coulibaly MO et al (2016) Anterior augmentation plating of aseptic humeral shaft nonunions after intramedullary nailing. Arch Orthop Trauma Surg 136:631–638CrossRef
5.
Zurück zum Zitat Emmerson KP, Sher JL (1998) A method of treatment of nonunion of humeral shaft fractures following treatment by locked intramedullary nail: a report of three cases. Injury 29:550–552CrossRef Emmerson KP, Sher JL (1998) A method of treatment of nonunion of humeral shaft fractures following treatment by locked intramedullary nail: a report of three cases. Injury 29:550–552CrossRef
6.
Zurück zum Zitat Gerber A, Marti R, Jupiter J (2003) Surgical management of diaphyseal humerus nonunion after intramedullary nailing: wave-plate fixation and autologous bone grafting without nail removal. J Shoulder Elb Surg 12:309–313CrossRef Gerber A, Marti R, Jupiter J (2003) Surgical management of diaphyseal humerus nonunion after intramedullary nailing: wave-plate fixation and autologous bone grafting without nail removal. J Shoulder Elb Surg 12:309–313CrossRef
7.
Zurück zum Zitat Ring D, Jupiter J (2004) Humerus nonunion after intramedullary rod fixation. Locking compression plate without removing the nail. Tech Orthop 18:356–359CrossRef Ring D, Jupiter J (2004) Humerus nonunion after intramedullary rod fixation. Locking compression plate without removing the nail. Tech Orthop 18:356–359CrossRef
8.
Zurück zum Zitat Nadkarni B, Srivastav SH, Mittal V, Agarwal SH (2008) Use of locking compression plates for long bone nonunions without removing existing intramedullary nail: review of literature and our experience. J Trauma 65:482–486CrossRef Nadkarni B, Srivastav SH, Mittal V, Agarwal SH (2008) Use of locking compression plates for long bone nonunions without removing existing intramedullary nail: review of literature and our experience. J Trauma 65:482–486CrossRef
9.
Zurück zum Zitat Allende C, Paz A, Altube G et al (2014) Revision with plates of humerus nonunions secondary to failed intramedullary nailing. Int Orthop 38:899–903CrossRef Allende C, Paz A, Altube G et al (2014) Revision with plates of humerus nonunions secondary to failed intramedullary nailing. Int Orthop 38:899–903CrossRef
10.
Zurück zum Zitat Vilaca PR, Uezumi MK (2012) Anterior minimally invasive bridge-plate technique for treatment of humeral shaft nonunion. J Orthopaed Traumatol 13:211–216CrossRef Vilaca PR, Uezumi MK (2012) Anterior minimally invasive bridge-plate technique for treatment of humeral shaft nonunion. J Orthopaed Traumatol 13:211–216CrossRef
11.
Zurück zum Zitat Weber BG, Pseudoarthrosis CO (1976) Pathophysiology, biomechanics, therapy, results. Huber, Bern Weber BG, Pseudoarthrosis CO (1976) Pathophysiology, biomechanics, therapy, results. Huber, Bern
12.
Zurück zum Zitat Lammens J, Bauduin G, Driesen R et al (1998) Treatment of nonunion of the humerus using the Ilizarov external fixator. Clin Orthop Relat Res 353:223–230CrossRef Lammens J, Bauduin G, Driesen R et al (1998) Treatment of nonunion of the humerus using the Ilizarov external fixator. Clin Orthop Relat Res 353:223–230CrossRef
13.
Zurück zum Zitat Patel VR, Menon DK, Pool RD, Simonis RB (2000) Nonunion of the humerus after failure of surgical treatment. Management using the Ilizarov circular fixator. J Bone Joint Surg Br 82:977–983CrossRef Patel VR, Menon DK, Pool RD, Simonis RB (2000) Nonunion of the humerus after failure of surgical treatment. Management using the Ilizarov circular fixator. J Bone Joint Surg Br 82:977–983CrossRef
14.
Zurück zum Zitat McKee MD, Miranda MA, Riemer BL (1996) Management of humeral nonunion after the failure of locking intramedullary nails. J Orthop Trauma 10:492–499CrossRef McKee MD, Miranda MA, Riemer BL (1996) Management of humeral nonunion after the failure of locking intramedullary nails. J Orthop Trauma 10:492–499CrossRef
15.
Zurück zum Zitat Dujardin FH, Mazirt N, Tobenas AC et al (2000) Failure of locked centro-medullary nailing in pseudarthrosis of the humeral diaphysis. Rev Chir Orthop Reparatrice Appar Mot 86:773–780PubMed Dujardin FH, Mazirt N, Tobenas AC et al (2000) Failure of locked centro-medullary nailing in pseudarthrosis of the humeral diaphysis. Rev Chir Orthop Reparatrice Appar Mot 86:773–780PubMed
16.
Zurück zum Zitat Ji F, Tong D, Tang H et al (2009) Minimally invasive percutaneous plate osteosynthesis (MIPPO) technique applied in the treatment of humeral shaft distal fractures through a lateral approach. Int Orthop 33:543–547CrossRef Ji F, Tong D, Tang H et al (2009) Minimally invasive percutaneous plate osteosynthesis (MIPPO) technique applied in the treatment of humeral shaft distal fractures through a lateral approach. Int Orthop 33:543–547CrossRef
17.
Zurück zum Zitat Rancan M, Dietrich M, Lamdark T et al (2010) Minimal invasive long Philos plate ostheosynthesis in methaphyseal fractures of the proximal humerus. Injury 41:1277–1283CrossRef Rancan M, Dietrich M, Lamdark T et al (2010) Minimal invasive long Philos plate ostheosynthesis in methaphyseal fractures of the proximal humerus. Injury 41:1277–1283CrossRef
18.
Zurück zum Zitat Wu CC (1996) Humeral shaft nonunion treated by a Seidel interlocking nail with a supplementary staple. Clin Orthop 326:203–208CrossRef Wu CC (1996) Humeral shaft nonunion treated by a Seidel interlocking nail with a supplementary staple. Clin Orthop 326:203–208CrossRef
19.
Zurück zum Zitat Flinkkila T, Ristiniemi J, Hamalainen M (2001) Nonunion after intramedullary nailing of humeral shaft fractures. J Trauma 50:540–544CrossRef Flinkkila T, Ristiniemi J, Hamalainen M (2001) Nonunion after intramedullary nailing of humeral shaft fractures. J Trauma 50:540–544CrossRef
20.
Zurück zum Zitat Anglen JO, Archdeacon MT, Cannada LK et al (2009) Avoiding complications in the treatment of humeral fractures. Instr Course Lect 58:3–11PubMed Anglen JO, Archdeacon MT, Cannada LK et al (2009) Avoiding complications in the treatment of humeral fractures. Instr Course Lect 58:3–11PubMed
21.
Zurück zum Zitat Rommens PM, Kuechle R, Bord T et al (2008) Humeral nailing revisited. Injury 39:1319–1328CrossRef Rommens PM, Kuechle R, Bord T et al (2008) Humeral nailing revisited. Injury 39:1319–1328CrossRef
22.
Zurück zum Zitat Reed AA, Joyner CJ, Brownlow HC, Simpson AH (2002) Human atrophic fracture non-unions are not avascular. J Orthop Res 20:593–599CrossRef Reed AA, Joyner CJ, Brownlow HC, Simpson AH (2002) Human atrophic fracture non-unions are not avascular. J Orthop Res 20:593–599CrossRef
23.
Zurück zum Zitat Ramoutar DN, Rodrigues J, Quah C et al (2011) Decortication and compression plate fixation of long bone non-union: is bone graft necessary? Injury 42:24–1434CrossRef Ramoutar DN, Rodrigues J, Quah C et al (2011) Decortication and compression plate fixation of long bone non-union: is bone graft necessary? Injury 42:24–1434CrossRef
Metadaten
Titel
Minimally invasive plate osteosynthesis in humerus nonunion after intramedullary nailing
verfasst von
Christian Allende
Fernando Vanoli
Luciano Gentile
Natalia Gutierrez
Publikationsdatum
24.03.2018
Verlag
Springer Berlin Heidelberg
Erschienen in
International Orthopaedics / Ausgabe 11/2018
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-018-3911-1

Weitere Artikel der Ausgabe 11/2018

International Orthopaedics 11/2018 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.