Abstract

Large acetabular defects can be reconstructed with various methods depending on size and location of the defect. We prospectively followed our first 37 patients in whom we reconstructed the acetabulum with a trabecular metal augment combined with a trabecular metal shell. Three patients died before completing the minimum 24 months followup while the remaining 34 were followed a minimum of 24 months (mean, 34 months; range, 24–55 months). All defects were classified according to Paprosky. Radiographic signs of osseointegration were classified according to Moore. Quality of life was measured with the SF-12, WOMAC, and Oxford Hip Score. There were 15 men and 19 women with an average age of 64 years. At a minimum of two years followup 32 of the 34 patients required no further surgery for aseptic loosening, while two had rerevision. Of the 32 patients who had not been revised, all had stable cups radiographically. All quality-of-life parameters improved. The early results with tantalum augments are promising but longer followup is required.
Level of Evidence: Level IV, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.
Literatur
1.
Zurück zum Zitat Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW. Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol. 1988;15:1833–1840.PubMed Bellamy N, Buchanan WW, Goldsmith CH, Campbell J, Stitt LW. Validation study of WOMAC: a health status instrument for measuring clinically important patient relevant outcomes to antirheumatic drug therapy in patients with osteoarthritis of the hip or knee. J Rheumatol. 1988;15:1833–1840.PubMed
3.
Zurück zum Zitat Bobyn JD, Poggie RA, Krygier JJ, Lewallen DG, Hanssen AD, Lewis RJ, Unger AS, O’Keefe, TJ, Christie MJ, Nasser S, Wood JE, Stulberg SD, Tanzer M. Clinical validation of a structural porous tantalum biomaterial for adult reconstruction. J Bone Joint Surg Am. 2004;86(Suppl 2):123–129. Bobyn JD, Poggie RA, Krygier JJ, Lewallen DG, Hanssen AD, Lewis RJ, Unger AS, O’Keefe, TJ, Christie MJ, Nasser S, Wood JE, Stulberg SD, Tanzer M. Clinical validation of a structural porous tantalum biomaterial for adult reconstruction. J Bone Joint Surg Am. 2004;86(Suppl 2):123–129.
4.
Zurück zum Zitat Chen WM, Engh CA Jr, Hopper RH Jr, McAuley JP, Engh CA. Acetabular revision with use of a bilobed component inserted without cement in patients who have acetabular bone-stock deficiency. J Bone Joint Surg Am. 2000;82:197–206.PubMed Chen WM, Engh CA Jr, Hopper RH Jr, McAuley JP, Engh CA. Acetabular revision with use of a bilobed component inserted without cement in patients who have acetabular bone-stock deficiency. J Bone Joint Surg Am. 2000;82:197–206.PubMed
5.
Zurück zum Zitat Christie MJ. Clinical applications of trabecular metal. Am J Orthop. 2002;31:219–220.PubMed Christie MJ. Clinical applications of trabecular metal. Am J Orthop. 2002;31:219–220.PubMed
6.
Zurück zum Zitat Dawson J, Fitzpatrick R, Carr A, Murray D. Questionnaire on the perceptions of patients about total hip replacement. J Bone Joint Surg Br. 1996;78:185–190.PubMed Dawson J, Fitzpatrick R, Carr A, Murray D. Questionnaire on the perceptions of patients about total hip replacement. J Bone Joint Surg Br. 1996;78:185–190.PubMed
7.
Zurück zum Zitat Dearborn JT, Harris WH. High placement of an acetabular component inserted without cement in a revision total hip arthroplasty. Results after a mean of ten years. J Bone Joint Surg Am. 1999;81:469–480.PubMed Dearborn JT, Harris WH. High placement of an acetabular component inserted without cement in a revision total hip arthroplasty. Results after a mean of ten years. J Bone Joint Surg Am. 1999;81:469–480.PubMed
8.
Zurück zum Zitat Dearborn JT, Harris WH. Acetabular revision arthroplasty using so-called jumbo cementless components: an average 7-year follow-up study. J Arthroplasty. 2000;15:8–15.PubMedCrossRef Dearborn JT, Harris WH. Acetabular revision arthroplasty using so-called jumbo cementless components: an average 7-year follow-up study. J Arthroplasty. 2000;15:8–15.PubMedCrossRef
9.
Zurück zum Zitat Dewal H, Chen F, Su E, Di Cesare PE. Use of structural bone graft with cementless acetabular cups in total hip arthroplasty. J Arthroplasty. 2003;18:23–28.PubMedCrossRef Dewal H, Chen F, Su E, Di Cesare PE. Use of structural bone graft with cementless acetabular cups in total hip arthroplasty. J Arthroplasty. 2003;18:23–28.PubMedCrossRef
10.
Zurück zum Zitat Garbuz D. Revision total hip: a novel modular cementless acetabular system for reconstruction of severe acetabular bone loss. Operative Techniques in Orthopaedics. 2004;14:117–120.CrossRef Garbuz D. Revision total hip: a novel modular cementless acetabular system for reconstruction of severe acetabular bone loss. Operative Techniques in Orthopaedics. 2004;14:117–120.CrossRef
11.
Zurück zum Zitat Goodman S, Saastamoinen H, Shasha N, Gross A. Complications of ilioischial reconstruction rings in revision total hip arthroplasty. J Arthroplasty. 2004;19:436–446.PubMedCrossRef Goodman S, Saastamoinen H, Shasha N, Gross A. Complications of ilioischial reconstruction rings in revision total hip arthroplasty. J Arthroplasty. 2004;19:436–446.PubMedCrossRef
12.
Zurück zum Zitat Gross AE. Revision arthroplasty of the acetabulum with restoration of bone stock. Clin Orthop Relat Res. 1999;369:198–207.PubMedCrossRef Gross AE. Revision arthroplasty of the acetabulum with restoration of bone stock. Clin Orthop Relat Res. 1999;369:198–207.PubMedCrossRef
13.
Zurück zum Zitat Gross AE, Goodman S. The role of cages and rings: when all else fails. Orthopedics. 2004;27:969–970.PubMed Gross AE, Goodman S. The role of cages and rings: when all else fails. Orthopedics. 2004;27:969–970.PubMed
14.
Zurück zum Zitat Gross AE, Goodman S. The current role of structural grafts and cages in revision arthroplasty of the hip. Clin Orthop Relat Res. 2004;429:193–200.PubMedCrossRef Gross AE, Goodman S. The current role of structural grafts and cages in revision arthroplasty of the hip. Clin Orthop Relat Res. 2004;429:193–200.PubMedCrossRef
15.
Zurück zum Zitat Moore MS, McAuley JP, Young AM, Engh CA Sr. Radiographic signs of osseointegration in porous-coated acetabular components. Clin Orthop Relat Res. 2006;444:176–183.PubMedCrossRef Moore MS, McAuley JP, Young AM, Engh CA Sr. Radiographic signs of osseointegration in porous-coated acetabular components. Clin Orthop Relat Res. 2006;444:176–183.PubMedCrossRef
16.
Zurück zum Zitat Nehme A, Lewallen DG, Hanssen AD. Modular porous metal augments for treatment of severe acetabular bone loss during revision hip arthroplasty. Clin Orthop Relat Res. 2004;429:201–208.PubMedCrossRef Nehme A, Lewallen DG, Hanssen AD. Modular porous metal augments for treatment of severe acetabular bone loss during revision hip arthroplasty. Clin Orthop Relat Res. 2004;429:201–208.PubMedCrossRef
17.
Zurück zum Zitat Paprosky WG, Perona PG, Lawrence JM. Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. J Arthroplasty. 1994;9:33–44. Paprosky WG, Perona PG, Lawrence JM. Acetabular defect classification and surgical reconstruction in revision arthroplasty. A 6-year follow-up evaluation. J Arthroplasty. 1994;9:33–44.
18.
Zurück zum Zitat Schreurs BW, Bolder SB, Gardeniers JW, Verdonschot N, Slooff TJ, Veth RP. Acetabular revision with impacted morsellised cancellous bone grafting and a cemented cup. A 15- to 20-year follow-up. J Bone Joint Surg Br. 2004;86:492–497.PubMed Schreurs BW, Bolder SB, Gardeniers JW, Verdonschot N, Slooff TJ, Veth RP. Acetabular revision with impacted morsellised cancellous bone grafting and a cemented cup. A 15- to 20-year follow-up. J Bone Joint Surg Br. 2004;86:492–497.PubMed
19.
Zurück zum Zitat Shinar AA, Harris WH. Bulk structural autogenous grafts and allografts for reconstruction of the acetabulum in total hip arthroplasty. Sixteen-year-average follow-up. J Bone Joint Surg Am. 1997;79:159–168.PubMed Shinar AA, Harris WH. Bulk structural autogenous grafts and allografts for reconstruction of the acetabulum in total hip arthroplasty. Sixteen-year-average follow-up. J Bone Joint Surg Am. 1997;79:159–168.PubMed
20.
Zurück zum Zitat Sporer SM, Paprosky WG. The use of a trabecular metal acetabular component and trabecular metal augment for severe acetabular defects. J Arthroplasty. 2006;21:83–86.PubMedCrossRef Sporer SM, Paprosky WG. The use of a trabecular metal acetabular component and trabecular metal augment for severe acetabular defects. J Arthroplasty. 2006;21:83–86.PubMedCrossRef
21.
Zurück zum Zitat Templeton JE, Callaghan, JJ, Goetz DD, Sullivan PM, Johnston RC. Revision of a cemented acetabular component to a cementless acetabular component. A ten to fourteen-year follow-up study. J Bone Joint Surg Am. 2001;83:1706–1711.PubMed Templeton JE, Callaghan, JJ, Goetz DD, Sullivan PM, Johnston RC. Revision of a cemented acetabular component to a cementless acetabular component. A ten to fourteen-year follow-up study. J Bone Joint Surg Am. 2001;83:1706–1711.PubMed
22.
Zurück zum Zitat Unger AS, Lewis RJ, Gruen T. Evaluation of a porous tantalum uncemented acetabular cup in revision total hip arthroplasty: clinical and radiological results of 60 hips. J Arthroplasty. 2005;20:1002–1009.PubMedCrossRef Unger AS, Lewis RJ, Gruen T. Evaluation of a porous tantalum uncemented acetabular cup in revision total hip arthroplasty: clinical and radiological results of 60 hips. J Arthroplasty. 2005;20:1002–1009.PubMedCrossRef
23.
Zurück zum Zitat Ware JE Jr, Sherbourne CD. The MOS 36-item short-form health survey (SF-36). I. Conceptual framework and item selection. Med Care. 1992;30:473–483.PubMedCrossRef Ware JE Jr, Sherbourne CD. The MOS 36-item short-form health survey (SF-36). I. Conceptual framework and item selection. Med Care. 1992;30:473–483.PubMedCrossRef
24.
Zurück zum Zitat Whaley AL, Berry DJ, Harmsen WS. Extra-large uncemented hemispherical acetabular components for revision total hip arthroplasty. J Bone Joint Surg Am. 2001;83:1352–1357.PubMed Whaley AL, Berry DJ, Harmsen WS. Extra-large uncemented hemispherical acetabular components for revision total hip arthroplasty. J Bone Joint Surg Am. 2001;83:1352–1357.PubMed
Metadaten
Titel
Modular Tantalum Augments for Acetabular Defects in Revision Hip Arthroplasty
verfasst von
Alexander Siegmeth, MD
Clive P. Duncan, MD, MSc
Bassam A. Masri, MD
Winston Y. Kim, MBChB
Donald S. Garbuz, MD, MHSc
Publikationsdatum
01.01.2009
Verlag
Springer-Verlag
Erschienen in
Clinical Orthopaedics and Related Research® / Ausgabe 1/2009
Print ISSN: 0009-921X
Elektronische ISSN: 1528-1132
DOI
https://doi.org/10.1007/s11999-008-0549-0

Weitere Artikel der Ausgabe 1/2009

Clinical Orthopaedics and Related Research® 1/2009 Zur Ausgabe

Symposium: Papers Presented at the Hip Society Meetings 2008

Cementing the Metaphyseal Stem in Metal-on-Metal Resurfacing: When and Why

Symposium: Papers Presented at the Hip Society Meetings 2008

Robert Merle d’Aubigné, 1900–1989

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.