Skip to main content
Erschienen in: Journal of Interventional Cardiac Electrophysiology 3/2010

01.12.2010

Morphological analysis of sinus and retrograde atrial waves detected through a permanent pacemaker atrial lead

verfasst von: Sami Pakarinen, Anne-Mari Vitikainen, Giorgio Corbucci, Lauri Toivonen

Erschienen in: Journal of Interventional Cardiac Electrophysiology | Ausgabe 3/2010

Einloggen, um Zugang zu erhalten

Abstract

Aims

The main objective of this study was to characterize morphological differences between sinus and retrograde atrial waves.

Methods

We collected intracardiac atrial signals through a DDDR pacemaker to characterize their morphologies and discriminate retrograde from sinus atrial waves off-line. Intracardiac unipolar and bipolar signals were collected at an 800-Hz sampling rate through a 0.4-Hz high-pass filter. Sinus and retrograde atrial waves during ventricular pacing were recorded in the supine and upright positions.

Results

Eleven different form parameters (FPs) were applied to describe atrial wave morphology. Data from 14 patients were collected and analyzed. Atrial signals differed markedly between the two body postures. However, it was possible to discriminate retrograde from sinus atrial waves on the basis of at least one FP in 12 of 14 (86%) patients when unipolar and bipolar atrial signals recorded in both body postures were analyzed separately. When body postures were pooled together to mimic natural conditions, discrimination was successful in nine of 14 patients with either configuration of the atrial signal.

Conclusions

The results indicate that retrograde atrial waves can be discriminated from sinus waves by using high sampling rate, digital signal processing, and specific FPs incorporated in these pacemakers.
Literatur
1.
Zurück zum Zitat Padeletti, L., & Barold, S. S. (2005). Digital technology for cardiac pacing. The American Journal of Cardiology, 95, 479–482.CrossRefPubMed Padeletti, L., & Barold, S. S. (2005). Digital technology for cardiac pacing. The American Journal of Cardiology, 95, 479–482.CrossRefPubMed
2.
Zurück zum Zitat Chiang, C. M., Jenkins, J. M., & Di Carlo, L. A. (1994). Digital signal processing chip implementation for detection and analysis of intracardiac electrograms. PACE, 17, 1373–1379.PubMed Chiang, C. M., Jenkins, J. M., & Di Carlo, L. A. (1994). Digital signal processing chip implementation for detection and analysis of intracardiac electrograms. PACE, 17, 1373–1379.PubMed
3.
Zurück zum Zitat van Hemel, N. M., Wohlgemuth, P., Engbers, J. G., Lawo, T., Nebaznivy, J., Taborsky, M., et al. (2004). Form analysis using digital signal processing reliably discriminates far field R-waves from P-waves. Pacing and Clinical Electrophysiology, 27, 1615–1624.CrossRefPubMed van Hemel, N. M., Wohlgemuth, P., Engbers, J. G., Lawo, T., Nebaznivy, J., Taborsky, M., et al. (2004). Form analysis using digital signal processing reliably discriminates far field R-waves from P-waves. Pacing and Clinical Electrophysiology, 27, 1615–1624.CrossRefPubMed
4.
Zurück zum Zitat Padeletti, L., Michelucci, A., Fröhlig, G., Corbucci, G., van Oort, G., & Barold, S. S. (2005). Digital technology in cardiac pacing: methods for morphology analysis of sensed endocavitary signal. Journal of Interventional Cardiac Electrophysiology, 14, 9–16.CrossRefPubMed Padeletti, L., Michelucci, A., Fröhlig, G., Corbucci, G., van Oort, G., & Barold, S. S. (2005). Digital technology in cardiac pacing: methods for morphology analysis of sensed endocavitary signal. Journal of Interventional Cardiac Electrophysiology, 14, 9–16.CrossRefPubMed
5.
Zurück zum Zitat Throne, R. D., Jenkins, J. M., Winston, S. A., Finelli, C. J., & Di Carlo, L. A. (1989). Discrimination of retrograde from anterograde atrial activation using intracardiac electrogram waveform analysis. Pacing and Clinical Electrophysiology, 12, 1622–1630.CrossRefPubMed Throne, R. D., Jenkins, J. M., Winston, S. A., Finelli, C. J., & Di Carlo, L. A. (1989). Discrimination of retrograde from anterograde atrial activation using intracardiac electrogram waveform analysis. Pacing and Clinical Electrophysiology, 12, 1622–1630.CrossRefPubMed
6.
Zurück zum Zitat Stroobandt, R. X. (2002). Morphology discrimination of ventricular tachycardia from supraventricular tachycardia by implantable cardioverter defibrillators: are implantable cardioverter defibrillators really starting to look at arrhythmias with the eyes of a cardiologist? Journal of Cardiovascular Electrophysiology, 13, 442–443.CrossRefPubMed Stroobandt, R. X. (2002). Morphology discrimination of ventricular tachycardia from supraventricular tachycardia by implantable cardioverter defibrillators: are implantable cardioverter defibrillators really starting to look at arrhythmias with the eyes of a cardiologist? Journal of Cardiovascular Electrophysiology, 13, 442–443.CrossRefPubMed
7.
Zurück zum Zitat Lewalter, T., Tuininga, Y., Fröhlig, G., Remerie, S., Eberhardt, F., Schmidt, J., et al. (2007). Morphology-enhanced atrial event classification improves sensing in pacemakers. Pacing and Clinical Electrophysiology, 30, 1455–1463.CrossRefPubMed Lewalter, T., Tuininga, Y., Fröhlig, G., Remerie, S., Eberhardt, F., Schmidt, J., et al. (2007). Morphology-enhanced atrial event classification improves sensing in pacemakers. Pacing and Clinical Electrophysiology, 30, 1455–1463.CrossRefPubMed
8.
Zurück zum Zitat Råde, L., & Westergren, B. (1989). Mathematics handbook for science and engineering (4th ed.). New York: Springer. Råde, L., & Westergren, B. (1989). Mathematics handbook for science and engineering (4th ed.). New York: Springer.
9.
Zurück zum Zitat McAllister, H. F., Klementowicz, P. T., Calderon, E. M., Benedek, Z. M., & Furman, S. (1988). Atrial electrogram analysis: antegrade versus retrograde. Pacing and Clinical Electrophysiology, 11(Pt 2), 1703–1707.CrossRef McAllister, H. F., Klementowicz, P. T., Calderon, E. M., Benedek, Z. M., & Furman, S. (1988). Atrial electrogram analysis: antegrade versus retrograde. Pacing and Clinical Electrophysiology, 11(Pt 2), 1703–1707.CrossRef
10.
Zurück zum Zitat Barold, S. S., Leonelli, F., Khan, N., Cutro, R., & Herweg, B. (2007). Pacemaker tachycardia: is it pacemaker-mediated tachycardia or sinus tachycardia? Pacing and Clinical Electrophysiology, 30(2), 256–257.CrossRefPubMed Barold, S. S., Leonelli, F., Khan, N., Cutro, R., & Herweg, B. (2007). Pacemaker tachycardia: is it pacemaker-mediated tachycardia or sinus tachycardia? Pacing and Clinical Electrophysiology, 30(2), 256–257.CrossRefPubMed
11.
Zurück zum Zitat Nielsen, J. C., Kristensen, L., Andersen, H. R., Mortensen, P. T., Pedersen, O. L., & Pedersen, A. K. (2003). A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome. Echocardiographic and clinical outcome. Journal of the American College of Cardiology, 42, 614–623.CrossRefPubMed Nielsen, J. C., Kristensen, L., Andersen, H. R., Mortensen, P. T., Pedersen, O. L., & Pedersen, A. K. (2003). A randomized comparison of atrial and dual-chamber pacing in 177 consecutive patients with sick sinus syndrome. Echocardiographic and clinical outcome. Journal of the American College of Cardiology, 42, 614–623.CrossRefPubMed
12.
Zurück zum Zitat Sweeney, M. O., Bank, A. J., Nsah, E., Koullick, M., Zeng, Q. C., Hettrick, D., et al. (2007). Minimizing ventricular pacing to reduce atrial fibrillation in sinus-node disease. The New England Journal of Medicine, 357, 1000–1008.CrossRefPubMed Sweeney, M. O., Bank, A. J., Nsah, E., Koullick, M., Zeng, Q. C., Hettrick, D., et al. (2007). Minimizing ventricular pacing to reduce atrial fibrillation in sinus-node disease. The New England Journal of Medicine, 357, 1000–1008.CrossRefPubMed
13.
Zurück zum Zitat Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., et al. (2002). ACC/AHA/NASPE 2002 guideline update for implantation of cardiac pacemakers and antiarrhythmia devices: summary article. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee on Pacemaker Implantation). Circulation, 106, 2145–2161. www.acc.org/clinical/guidelines/pacemaker/pacemaker.pdf.CrossRefPubMed Gregoratos, G., Abrams, J., Epstein, A. E., Freedman, R. A., Hayes, D. L., Hlatky, M. A., et al. (2002). ACC/AHA/NASPE 2002 guideline update for implantation of cardiac pacemakers and antiarrhythmia devices: summary article. A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/NASPE Committee on Pacemaker Implantation). Circulation, 106, 2145–2161. www.​acc.​org/​clinical/​guidelines/​pacemaker/​pacemaker.​pdf.CrossRefPubMed
14.
Zurück zum Zitat Barold, S. S., & Levine, P. A. (2001). Pacemaker repetitive nonreentrant ventriculoatrial synchronous rhythm. A review. Journal of Interventional Cardiac Electrophysiology, 5, 45–58.CrossRefPubMed Barold, S. S., & Levine, P. A. (2001). Pacemaker repetitive nonreentrant ventriculoatrial synchronous rhythm. A review. Journal of Interventional Cardiac Electrophysiology, 5, 45–58.CrossRefPubMed
15.
Zurück zum Zitat Gillis, A. M., Unterberg-Buchwald, C., Schmidinger, H., Massimo, S., Wolfe, K., Kavaney, D. J., et al. (2002). Safety and efficacy of advanced atrial pacing therapies for atrial tachyarrhythmias in patients with a new implantable dual-chamber cardioverter-defibrillator. Journal of the American College of Cardiology, 40, 1653–1659.CrossRefPubMed Gillis, A. M., Unterberg-Buchwald, C., Schmidinger, H., Massimo, S., Wolfe, K., Kavaney, D. J., et al. (2002). Safety and efficacy of advanced atrial pacing therapies for atrial tachyarrhythmias in patients with a new implantable dual-chamber cardioverter-defibrillator. Journal of the American College of Cardiology, 40, 1653–1659.CrossRefPubMed
Metadaten
Titel
Morphological analysis of sinus and retrograde atrial waves detected through a permanent pacemaker atrial lead
verfasst von
Sami Pakarinen
Anne-Mari Vitikainen
Giorgio Corbucci
Lauri Toivonen
Publikationsdatum
01.12.2010
Verlag
Springer US
Erschienen in
Journal of Interventional Cardiac Electrophysiology / Ausgabe 3/2010
Print ISSN: 1383-875X
Elektronische ISSN: 1572-8595
DOI
https://doi.org/10.1007/s10840-010-9515-3

Weitere Artikel der Ausgabe 3/2010

Journal of Interventional Cardiac Electrophysiology 3/2010 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.