Skip to main content
Erschienen in: Abdominal Radiology 11/2020

20.05.2020 | Special Section: chronic liver disease

MR imaging assessment and quantification of liver iron

verfasst von: Manuela França, João Gomes Carvalho

Erschienen in: Abdominal Radiology | Ausgabe 11/2020

Einloggen, um Zugang zu erhalten

Abstract

Iron overload is a common clinical problem resulting from hereditary hemochromatosis or secondary hemosiderosis (mainly associated with transfusion therapy), being also associated with chronic liver diseases and metabolic disorders. Excess of iron accumulates in organs like the liver, pancreas and heart. Without treatment, patients with iron overload disorders will develop liver cirrhosis, diabetes and cardiomyopathy. Iron quantification is therefore crucial not only for diagnosis of iron overload but also to monitor iron-reducing therapies. Liver iron concentration is considered the surrogate marker of total body iron stores. Because liver biopsy is invasive and prone to high variability and sampling bias, MR imaging has emerged as a non-invasive method and gained wide acceptance, now being considered the standard of care for assessing iron overload. Nevertheless, there are different MR techniques for iron quantification and there is still no consensus about the best technique or postprocessing tool for hepatic iron quantification, with the choice of imaging technique depending mainly on the local expertise as well on the available equipment and software. Because different methods should not be used interchangeably, it is important to choose one method and use the same one when following up patients over time.
Literatur
9.
Zurück zum Zitat Piperno A (1998) Classification and diagnosis of iron overload. Haematologica 83:447–455.PubMed Piperno A (1998) Classification and diagnosis of iron overload. Haematologica 83:447–455.PubMed
17.
Zurück zum Zitat Brissot P, Bourel M, Herry D, Verger JP, Messner M, Beaumont C, Regnouard F, Ferrand B, Simon M (1981) Assessment of liver iron content in 271 patients: a re-evaluation of direct and indirect methods. Gastroenterology 80:557–565.CrossRefPubMed Brissot P, Bourel M, Herry D, Verger JP, Messner M, Beaumont C, Regnouard F, Ferrand B, Simon M (1981) Assessment of liver iron content in 271 patients: a re-evaluation of direct and indirect methods. Gastroenterology 80:557–565.CrossRefPubMed
20.
Zurück zum Zitat Villeneuve JP, Bilodeau M, Lepage R, Côté J, Lefebvre M (1996) Variability in hepatic iron concentration measurement from needle-biopsy specimens. J Hepatol 25:172–177.CrossRefPubMed Villeneuve JP, Bilodeau M, Lepage R, Côté J, Lefebvre M (1996) Variability in hepatic iron concentration measurement from needle-biopsy specimens. J Hepatol 25:172–177.CrossRefPubMed
30.
Zurück zum Zitat Garbowski MW, Carpenter J-P, Smith G, Roughton M, Alam MH, He T, Pennell DJ, Porter JB (2014) Biopsy-based calibration of T2* magnetic resonance for estimation of liver iron concentration and comparison with R2 Ferriscan. J Cardiovasc Magn Reson 16:1–11. https://doi.org/10.1186/1532-429X-16-40CrossRef Garbowski MW, Carpenter J-P, Smith G, Roughton M, Alam MH, He T, Pennell DJ, Porter JB (2014) Biopsy-based calibration of T2* magnetic resonance for estimation of liver iron concentration and comparison with R2 Ferriscan. J Cardiovasc Magn Reson 16:1–11. https://​doi.​org/​10.​1186/​1532-429X-16-40CrossRef
44.
Zurück zum Zitat Yokoo T, Browning JD. Fat and iron quantification in the liver: past, present, and future. Top Magn Reson Imaging. 2014;23(2):73-94.CrossRefPubMed Yokoo T, Browning JD. Fat and iron quantification in the liver: past, present, and future. Top Magn Reson Imaging. 2014;23(2):73-94.CrossRefPubMed
46.
47.
49.
Zurück zum Zitat Kirk P, He T, Anderson LJ, Roughton M, Tanner MA, Lam WWM, Au WY, Chu WCW, Chan G, Galanello R, Matta G, Fogel M, Cohen AR, Tan RS, Chen K, Ng I, Lai A, Fucharoen S, Laothamata J, Chuncharunee S, Jongjirasiri S, Firmin DN, Smith GC, Pennell DJ (2010) International reproducibility of single breathhold T2* MR for cardiac and liver iron assessment among five thalassemia centers. J Magn Reson Imaging 32:315–319. https://doi.org/10.1002/jmri.22245CrossRefPubMedPubMedCentral Kirk P, He T, Anderson LJ, Roughton M, Tanner MA, Lam WWM, Au WY, Chu WCW, Chan G, Galanello R, Matta G, Fogel M, Cohen AR, Tan RS, Chen K, Ng I, Lai A, Fucharoen S, Laothamata J, Chuncharunee S, Jongjirasiri S, Firmin DN, Smith GC, Pennell DJ (2010) International reproducibility of single breathhold T2* MR for cardiac and liver iron assessment among five thalassemia centers. J Magn Reson Imaging 32:315–319. https://​doi.​org/​10.​1002/​jmri.​22245CrossRefPubMedPubMedCentral
50.
Zurück zum Zitat Tanner MA, He T, Westwood MA, Firmin DN, Pennell DJ. Multi-center validation of the transferability of the magnetic resonance T2* technique for the quantification of tissue iron. Haematologica. 2006;91(10):1388-1391.PubMed Tanner MA, He T, Westwood MA, Firmin DN, Pennell DJ. Multi-center validation of the transferability of the magnetic resonance T2* technique for the quantification of tissue iron. Haematologica. 2006;91(10):1388-1391.PubMed
55.
Zurück zum Zitat Meloni A, Positano V, Keilberg P, De Marchi D, Pepe P, Zuccarelli A, Campisi S, Romeo MA, Casini T, Bitti PP, Gerardi C, Lai ME, Piraino B, Giuffrida G, Secchi G, Midiri M, Lombardi M, Pepe A (2012) Feasibility, reproducibility, and reliability for the T2* iron evaluation at 3 T in comparison with 1.5 T. Magn Reson Med 68:543–551. https://doi.org/10.1002/mrm.23236CrossRefPubMed Meloni A, Positano V, Keilberg P, De Marchi D, Pepe P, Zuccarelli A, Campisi S, Romeo MA, Casini T, Bitti PP, Gerardi C, Lai ME, Piraino B, Giuffrida G, Secchi G, Midiri M, Lombardi M, Pepe A (2012) Feasibility, reproducibility, and reliability for the T2* iron evaluation at 3 T in comparison with 1.5 T. Magn Reson Med 68:543–551. https://​doi.​org/​10.​1002/​mrm.​23236CrossRefPubMed
56.
Zurück zum Zitat Li J, Lin H, Liu T, Zhang Z, Prince MR, Gillen K, Yan X, Song Q, Hua T, Zhao X, Zhang M, Zhao Y, Li G, Tang G, Yang G, Brittenham GM, Wang Y (2018) Quantitative susceptibility mapping (QSM) minimizes interference from cellular pathology in R2* estimation of liver iron concentration. J Magn Reson Imaging 48:1069–1079. https://doi.org/10.1002/jmri.26019CrossRefPubMedPubMedCentral Li J, Lin H, Liu T, Zhang Z, Prince MR, Gillen K, Yan X, Song Q, Hua T, Zhao X, Zhang M, Zhao Y, Li G, Tang G, Yang G, Brittenham GM, Wang Y (2018) Quantitative susceptibility mapping (QSM) minimizes interference from cellular pathology in R2* estimation of liver iron concentration. J Magn Reson Imaging 48:1069–1079. https://​doi.​org/​10.​1002/​jmri.​26019CrossRefPubMedPubMedCentral
62.
Zurück zum Zitat Schwenzer NF, Machann J, Haap MM, Martirosian P, Schraml C, Liebig G, Stefan N, Häring H-U, Claussen CD, Fritsche A, Schick F (2008) T2* relaxometry in liver, pancreas, and spleen in a healthy cohort of one hundred twenty-nine subjects-correlation with age, gender, and serum ferritin. Invest Radiol 43:854–860. https://doi.org/10.1097/RLI.0b013e3181862413CrossRefPubMed Schwenzer NF, Machann J, Haap MM, Martirosian P, Schraml C, Liebig G, Stefan N, Häring H-U, Claussen CD, Fritsche A, Schick F (2008) T2* relaxometry in liver, pancreas, and spleen in a healthy cohort of one hundred twenty-nine subjects-correlation with age, gender, and serum ferritin. Invest Radiol 43:854–860. https://​doi.​org/​10.​1097/​RLI.​0b013e3181862413​CrossRefPubMed
64.
Zurück zum Zitat França M, Martí-Bonmatí L, Silva S, Oliveira C, Alberich-Bayarri A, Vilas Boas F, Pessegueiro-Miranda H, Porto G (2017) Optimizing the management of hereditary haemochromatosis: the value of MRI R2* quantification to predict and monitor body iron stores. Br J Haematol 183:491–493. https://doi.org/10.1111/bjh.14982CrossRefPubMed França M, Martí-Bonmatí L, Silva S, Oliveira C, Alberich-Bayarri A, Vilas Boas F, Pessegueiro-Miranda H, Porto G (2017) Optimizing the management of hereditary haemochromatosis: the value of MRI R2* quantification to predict and monitor body iron stores. Br J Haematol 183:491–493. https://​doi.​org/​10.​1111/​bjh.​14982CrossRefPubMed
Metadaten
Titel
MR imaging assessment and quantification of liver iron
verfasst von
Manuela França
João Gomes Carvalho
Publikationsdatum
20.05.2020
Verlag
Springer US
Erschienen in
Abdominal Radiology / Ausgabe 11/2020
Print ISSN: 2366-004X
Elektronische ISSN: 2366-0058
DOI
https://doi.org/10.1007/s00261-020-02574-8

Weitere Artikel der Ausgabe 11/2020

Abdominal Radiology 11/2020 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.