Skip to main content
Erschienen in: Pediatric Cardiology 4/2008

01.07.2008 | Original Article

Multidetector CT Angiography and 3D Reconstruction in Young Children with Coarctation of the Aorta

verfasst von: Xi-Hong Hu, Guo-Ying Huang, Mier Pa, Xin Li, Lin Wu, Fang Liu, Bing Jia, Guo-ping Li

Erschienen in: Pediatric Cardiology | Ausgabe 4/2008

Einloggen, um Zugang zu erhalten

Abstract

The purpose of this study was to assess the reliability of multidetector CT (MDCT) angiography and three-dimensional (3D) reconstruction in patients with coarctation of the aorta. Sixteen patients (median age, 2 months; range, 15 days to 28 months) with suspected coarctation of the aorta underwent both color Doppler echocardiography (CDE) and MDCT. In addition to the CT axial slices, 3D reconstructions such as volume rendering and multiple planar reformation were used to diagnose coarctation and associated cardiac abnormalities. The sensitivities of diagnosis were evaluated compared with MDCT and echocardiography and surgical findings. Sixteen cases were diagnosed as coarctation of the aorta by MDCT. This included hypoplasia of the aortic arch (n = 5). The results were confirmed at the time of surgery. Diagnosis sensitivities of coarctation were 87.5% for axial and 100% for both multiplanar and 3D volume-rendered images. Moreover, MDCT was able to clearly display the location and extent of the coarctation. Focal defects were observed in 14 cases, and diffuse defects in 2 cases. The sensitivity of MDCT diagnosis for coarctation of the aorta was 100%, which was higher than that of CDE (87.5%). Ventricular septum defect was diagnosed by MDCT in 11 cases, with 1 missed, and the sensitivity was 91.7% (11/12), which was lower than that of CDE (100%; 12/12). In addition, six patients had patent ductus arteriosus. Two patients in this study had collateral vessel formation. We conclude that CTA with 3D reconstruction represents a reliable noninvasive technique for the assessment of coarctation. It may serve as a noninvasive diagnostic tool before intervention or surgical treatment.
Literatur
1.
Zurück zum Zitat Cody DD (2002) Image processing in CT. RadioGraphics 22:1255–1268PubMed Cody DD (2002) Image processing in CT. RadioGraphics 22:1255–1268PubMed
2.
Zurück zum Zitat Cohen RA, Frush DP, Donnelly LF (2000) Data acquisition for pediatric CT angiography: problems and solutions. Pediatr Radiol 30:813–822PubMedCrossRef Cohen RA, Frush DP, Donnelly LF (2000) Data acquisition for pediatric CT angiography: problems and solutions. Pediatr Radiol 30:813–822PubMedCrossRef
3.
Zurück zum Zitat Gilkeson RC, Ciancidello L, Zahka K (2003) Multidetector CT evaluation of congenital heart disease in pediatric and adult patients. Am J Roentgenol 180:973–980 Gilkeson RC, Ciancidello L, Zahka K (2003) Multidetector CT evaluation of congenital heart disease in pediatric and adult patients. Am J Roentgenol 180:973–980
4.
Zurück zum Zitat Goo HW, Park IS, Ko JK, Kim YH, Seo DM, Yun TJ, Park JJ, Yoon CH (2003) CT of congenital heart disease: normal anatomy and typical pathologic conditions. Radiographics 23:S147–S165PubMedCrossRef Goo HW, Park IS, Ko JK, Kim YH, Seo DM, Yun TJ, Park JJ, Yoon CH (2003) CT of congenital heart disease: normal anatomy and typical pathologic conditions. Radiographics 23:S147–S165PubMedCrossRef
5.
Zurück zum Zitat Goo HW, Park IS, Ko JK, Kim YH, Seo DM, Park JJ (2005) Computed tomography for the diagnosis of congenital heart disease in pediatric and adult patients. Int J of Cardiovasc Imaging 21:347–365CrossRef Goo HW, Park IS, Ko JK, Kim YH, Seo DM, Park JJ (2005) Computed tomography for the diagnosis of congenital heart disease in pediatric and adult patients. Int J of Cardiovasc Imaging 21:347–365CrossRef
6.
Zurück zum Zitat Kuszyk BS, Heath DG, Johnson PT, Eng J, Fishman EK (1999) CT angiography with volume rendering for quantifying vascular stenoses: in vitro validation of accuracy. Am J Roentgenol 173:449–455 Kuszyk BS, Heath DG, Johnson PT, Eng J, Fishman EK (1999) CT angiography with volume rendering for quantifying vascular stenoses: in vitro validation of accuracy. Am J Roentgenol 173:449–455
7.
Zurück zum Zitat Ravenel JG, McAdams HP, Remy-Jardin M, Remy J (2001) Multidimensional imaging of the thorax. Practical applications. J Thorac Imaging 16:269–281CrossRef Ravenel JG, McAdams HP, Remy-Jardin M, Remy J (2001) Multidimensional imaging of the thorax. Practical applications. J Thorac Imaging 16:269–281CrossRef
8.
Zurück zum Zitat Shih MC, Tholpady A, Kramer CM, Sydnor MK, Hagspiel KD (2006) Surgical and endovascular repair of aortic coarctation: normal findings and appearance of complications on CT angiography and MR angiography. Am J Roentgenol 187:W302–W312CrossRef Shih MC, Tholpady A, Kramer CM, Sydnor MK, Hagspiel KD (2006) Surgical and endovascular repair of aortic coarctation: normal findings and appearance of complications on CT angiography and MR angiography. Am J Roentgenol 187:W302–W312CrossRef
Metadaten
Titel
Multidetector CT Angiography and 3D Reconstruction in Young Children with Coarctation of the Aorta
verfasst von
Xi-Hong Hu
Guo-Ying Huang
Mier Pa
Xin Li
Lin Wu
Fang Liu
Bing Jia
Guo-ping Li
Publikationsdatum
01.07.2008
Verlag
Springer-Verlag
Erschienen in
Pediatric Cardiology / Ausgabe 4/2008
Print ISSN: 0172-0643
Elektronische ISSN: 1432-1971
DOI
https://doi.org/10.1007/s00246-008-9226-z

Weitere Artikel der Ausgabe 4/2008

Pediatric Cardiology 4/2008 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.