Skip to main content
Erschienen in: Journal of Cardiovascular Magnetic Resonance 1/2016

Open Access 01.12.2016 | Review

Myocardial arterial spin labeling

verfasst von: Frank Kober, Terrence Jao, Thomas Troalen, Krishna S. Nayak

Erschienen in: Journal of Cardiovascular Magnetic Resonance | Ausgabe 1/2016

Abstract

Arterial spin labeling (ASL) is a cardiovascular magnetic resonance (CMR) technique for mapping regional myocardial blood flow. It does not require any contrast agents, is compatible with stress testing, and can be performed repeatedly or even continuously. ASL-CMR has been performed with great success in small-animals, but sensitivity to date has been poor in large animals and humans and remains an active area of research. This review paper summarizes the development of ASL-CMR techniques, current state-of-the-art imaging methods, the latest findings from pre-clinical and clinical studies, and future directions. We also explain how successful developments in brain ASL and small-animal ASL-CMR have helped to inform developments in large animal and human ASL-CMR.
Hinweise

Competing interests

The authors declare that they have no competing interests.

Authors’ contribution

FK: manuscript design, drafting, and revision, literature review, coordination among co-authors, final revisions. TJ: literature review, manuscript drafting and revision. TT: literature review, manuscript drafting and revision. KN: manuscript design, drafting, and revision, literature review, coordination among co-authors. All authors read and approved the manuscript.
Abkürzungen
1.5 T
1.5 Tesla
2D
2-dimensional
3 T
3 Tesla
ASL
arterial spin labeling
ATT
arterial transit time
BBB
blood - brain barrier
BLOSM
block low-rank sparsity with motion guidance
CAD
coronary artery disease
CBF
cerebral blood flow
CHD
coronary heart disease
CKD
chronic kidney disease
CMR
cardiovascular magnetic resonance
ECG
electrocardiogram
ESRD
end-stage renal disease
EPI
echo-planar Imaging
EPISTAR
EPI signal tagging with alternating radiofrequency
FAIR
flow-sensitive alternating inversion recovery
FLASH
fast low angle shot
GBCA
Gadolinium-based contrast agents
Gd
Gadolinium
GRAPPA
generalized autocalibrating partially parallel acquisitions
GRE
gradient echo
HR
heart rate
k-t PCA
k-space-time principle component analysis
k-t SENSE
k-space-time sensitivity encoding
LLFAIR
Look-Locker flow-sensitive alternating inversion recovery
LLFAIRGE
Look-Locker flow-sensitive alternating inversion recovery respiratory gated
LV
left ventricle
MBF
myocardial blood flow
MBV
myocardial blood volume
nNOS
neuronal nitric oxide synthase
PASL
pulsed arterial spin labeling
PCASL
psuedo-continuous arterial spin labeling
PET
positron emission tomography
PN
physiological noise
RF
radiofrequency
SNR
signal - to - noise ratio
spASL
steady pulsed arterial spin labeling
SPECT
single-photon emission computed tomography
SSFP
steady - state free precession
Time-SLIP
time-spatial inversion pulse

Background

Arterial spin labeling is a cardiovascular magnetic resonance (CMR) technique for quantifying tissue blood flow, non-invasively and without contrast agents [1, 2]. Radiofrequency pulses are used to modify the longitudinal magnetization of arterial blood, creating an endogenous label (or tracer) that decays with the time-constant equal to the T1 relaxation time, about 1.5 seconds for blood at 3 Tesla. After a delay to allow labeled blood to flow into the target tissue, images are acquired that reflect inflow of labeled blood as well as static tissue whose magnetization exchanges with that of the inflowing blood. A second set of images is acquired in the absence of a preceding labeling pulse. The difference between these two image sets reflects the amount of labeled blood that has been delivered to the imaging region, and with appropriate labeling, imaging, and perfusion model, can be made directly proportional to tissue blood flow (in mL-blood per g-tissue per minute). This process is illustrated in Fig. 1.
For myocardial perfusion applications, ASL is an attractive alternative to first-pass CMR and traditional nuclear medicine for two reasons. First, it does not require intravenous contrast agents or ionizing radionuclides, and therefore can be performed repeatedly or even continuously with no incremental risk to the patient. Second, it provides measurements that are directly proportional to myocardial blood flow as opposed to a relative measurement that requires designating an area of normal myocardium for comparison [3, 4]. Therefore, ASL could be more sensitive for detection of disease that reduces perfusion globally such as balanced ischemia, microvascular disease and multi-vessel disease.

Review

First-pass gadolinium enhanced perfusion CMR has a long history in both clinical research and diagnostic routine, mainly for the evaluation of ischemic heart disease [5]. Its superiority for diagnosing CAD compared with SPECT was shown in several large multi-center trials including CE-MARC and MR-IMPACT [68]. First-pass CMR owes its success mainly to its high spatial resolution compared with nuclear imaging techniques. Also, the contrast change produced by the contrast agent bolus during a perfusion measurement is high (of the order of 60 % with saturation-recovery SSFP techniques in normal myocardium [9]), the delineation of territories with perfusion defects can be done without sophisticated post-processing tools. The standard approach for clinical interpretation is visual delineation of hypo-perfused territories.
Quantitative or at least a semi-quantitative analysis of perfusion is desirable particularly in non-ischemic cardiomyopathies affecting microvasculature, which cause only subtle and non-focal defects. While first-pass CMR does allow quantification of blood flow, the mathematical modeling of contrast dynamics is relatively complex and hasn’t yet found consensus in the community. Absolute quantification with first-pass CMR requires a measurement of the Arterial Input Function (AIF), which has to be obtained without saturation of the contrast/concentration curve. This implies the use of either dual-contrast pulse sequences [10] or dual-bolus protocols [11, 12]. First-pass CMR is therefore an excellent and widely recognized method for identifying and delineating altered tissue in ischemic heart disease thanks to very good detection sensitivity. Robust absolute MBF quantification approaches are, however, still subject of ongoing research.
One important limitation of first-pass CMR stems from the use of Gadolinium-based contrast agents (GBCA), which have known toxicity in patients with renal failure. In these patients, excessive use can lead to organ fibrosis and failure. GBCA’s are contraindicated in patients with end-stage renal disease (ESRD), which is a small but significant part of the CMR patient population, due to their need for frequent cardiovascular assessment. ESRD prevalence is on the rise, with an annual growth rate of 3–4 % in the US [13], and ~7 % worldwide [14]. These patients would benefit from a new safer alternative, as they require ischemic heart disease testing every 12 months to a) determine preoperative cardiovascular risk prior to kidney transplant surgery and b) because they have >10 times higher cardiovascular mortality than the general population [15, 16]. These patients cannot receive GBCA because of poor kidney function and experience an unreasonably large radiation dose from frequent stress testing using SPECT or PET [1719]. Today, many centers use a less sensitive dobutamine stress echo test to screen for cardiovascular disease in ESRD patients.
ASL-CMR is a totally non-invasive alternative that uses magnetically labeled blood as an endogenous tracer. It would therefore offer accessibility of perfusion CMR to patients with contraindications to GBCA. ASL-CMR is therefore increasingly relevant in patients with Chronic Kidney Disease (CKD), the elderly in general, and the growing number of patients who simply refuse diagnostic tests involving contrast or radiation.
The contrast differences created by magnetic labeling of blood are inherently limited, and ASL therefore features much lower sensitivity than 1st pass techniques. The signal in ASL is indeed directly proportional to myocardial blood flow. The myocardial tissue magnetization difference created by magnetic blood labeling depends on the labeling type and is lower than 4 % in humans (as an example: 1.5 % [20]). However, for a number of reasons, absolute quantification with ASL is at least theoretically more reliable and more accurate: 1) The created bolus of labeled magnetization is short and its spatial profile is almost perfectly rectangular, 2) the timing and shape of this bolus do not vary between experiments, 3) the signal to concentration relation is perfectly linear, since only water is used as tracer, and 4) the measurement is freely repeatable without bias across consecutive measurements.
The repeatability of ASL-CMR is particularly interesting for rest/stress comparisons, since measurements could be carried out in a continuous way to monitor tissue blood flow changes during stress. Furthermore, the possibility to do absolute quantification would make ASL a good candidate for longitudinal therapeutic monitoring and disease follow-up studies.

From the brain to the heart

ASL methods for measuring cerebral blood flow are robust and widely used in the research setting, for example, to assess stroke [21, 22], and functional brain activation [2325]. A recent consensus document has provided recommended protocols that are available on commercial platforms and has received broad support from the developer and user community [26]. The success and maturity of ASL in the brain has provided significant motivation for ASL-CMR and has provided a significant toolbox of techniques that may be applied in ASL-CMR.
There are several important physiological and practical factors that necessitate the use of different ASL labeling and imaging methods for measuring myocardial blood flow (MBF) and cerebral blood flow (CBF), respectively. These are summarized in Table 1, and discussed briefly here. Tissue blood flow is higher in the myocardium compared to the brain, roughly 2x higher at rest and 5–7x higher during vasodilation, resulting in a stronger ASL signal. Water exchange kinetics of labeled spins to tissue water are assumed to be instantaneous in the heart while the blood-brain barrier (BBB) decreases the exchange rate of water in the brain. The upstream pathway that blood travels to perfuse the myocardium is complicated compared to the brain. This influences scan timing, and the selection of labeling geometries as blood that perfuses the myocardium may have been in the imaging volume a few seconds prior. The heart is also moving rapidly and blood flow is highly pulsatile. This requires labeling and imaging methods that are synchronized to the cardiac cycle. Imaging is typically performed during quiescent periods, end-systole and mid-diastole. The intrinsic SNR efficiency of modern MRI systems with the latest in receiver coil technology is 3.5x lower in the heart compared to the brain (for normal weight subjects). This is due largely to the need for large coil arrays, with greater distance between coil and tissue, and larger noise volume. This SNR penalty is greater for overweight and obese subjects. Finally, the optimal imaging methods must provide highest possible tissue SNR efficiency, which is influenced by T1 and T2, which are different for myocardium compared to gray/white matter. These differences are all critical for the design of ASL-CMR methods, and for understanding how they subtly and significantly differ from brain ASL methods.
Table 1
Factors that impact the use of ASL in heart and in the brain, for measuring myocardial blood flow (MBF) and cerebral blood flow (CBF), respectively
 
Heart (MBF)
Brain (CBF)
Tissue Blood Flow
0.5 – 1.5 mL/g/min (rest)
3.0 – 5.0 mL/g/min (stress)
0.35 – 0.55 mL/g/min [100]
Water Kinetics
Instantaneous exchange
Decreased water exchange due to blood brain barrier (BBB)
Blood pathway
Many directions; Blood passes through left atrium, left ventricle, aortic root, coronary arteries and then myocardium.
Unidirectional; Internal carotids and vertebral arteries deliver blood to the Circle of Willis, then to branch vessels, then to the brain. Blood flowing primarily inferior to superior.
Motion
Significant cardiac motion; Quiescent periods are:
End systole: ~80 ms long
Mid diastole: 0-150 ms long depending on heart rate.
Respiratory motion must be handled either by limiting the acquisition time to a breath-hold or by correcting for motion
Insignificant motion compared to the spatial resolution typically used (~2 mm).
Intrinsic SNR efficiency
1/3 of Brain (normal weight subjects); due to larger distance from receiver coil elements and larger noise volume
 
Imaging Concerns
Imaging must be performed during quiescent cardiac phases.
 
Labeling Concerns
Direction of Flow
Pulsatile Flow
Cardiac Motion
Maximum efficiency (pseudo-continuous labeling recommended [26])
Optimal Readouts
For maximum myocardial signal:
Snapshot balanced SSFP
Single-shot EPI
For maximum gray/white matter signal:
Single-shot Spiral
Single-shot EPI
Many of the fundamental developments in ASL were first applied and validated in the brain. Of particular relevance, two signal models have been developed for extracting tissue blood flow from ASL signals. The “dual T1” approach by Detre et al. and the general kinetic model by Buxton et al. have both been used in ASL-CMR [2729]. Methods for pulsed labeling, including methods that balance magnetization transfer effects, were first developed in the brain and have been applied in ASL-CMR [29, 30]. And several other methods have not yet been successfully used in ASL-CMR, but show promise. These include: background suppression (to reduce physiological noise), velocity-selective labeling (to provide measurements independent of transit delay), pseudo-continuous labeling (to maximize labeling efficiency), and simultaneous multi-slice imaging (to broaden spatial coverage without increasing scan time).

From mouse to man

Interestingly, perfusion MRI including perfusion CMR has gone in two completely different directions for clinical and pre-clinical application. The reasons for this become clear when comparing the major morphologic, physiologic and MRI-technical factors that differ between humans and rodents, summarized in Table 2. Beyond the obvious differences in size, the rodent heart is characterized by dramatically higher heart rate, cardiac index and blood turnover in the body. Another interesting difference is given by the flow velocities in large vessels, which are indeed comparable between humans and rodents despite the difference in body size. Myocardial blood flow is roughly five times higher in rodents than in humans. These given facts have consequences for the design and the feasibility of CMR techniques in rodents in general and for perfusion CMR techniques in particular.
Table 2
Comparison of typical major cardiovascular features between humans and rodents. The values for rats and mice are average values typical for animals under isoflurane anesthesia. The differences in blood recirculation time and capillary blood flow have strong impact on the choice of methods for measuring perfusion
 
Human
Rat
Mouse
Body weight
80 kg
0.3 kg
0.03 kg
Total blood volume
5 L
18 mL
1.8 mL
End diastolic volume (EDV)
180 mL
300 μL
50 μL
Myocardial Mass
150 g
0.6 g
0.1 g
Heart Rate
80 bpm
300 bpm
600 bpm
Cardiac Output
5 L/min
0.15 L/min
0.020 L/min
Time of recirculation
60 s
7 s
5 s
Aortic ejection velocity [101103]
100 cm/s
200 cm/s
300 cm/s
Breathing rate
12 bpm
70 bpm
110 bpm
Myocardial perfusion (MBF)
1 mL/g/min
5 mL/g/min
7 mL/g/min
For first-pass CMR, the fact that blood circulation times in rodents are very short requires short bolus injection durations with high demand on the power injector performance for generating a reproducible shape. It also requires very rapid imaging techniques for sampling the AIF with sufficient time resolution. Fast imaging is also required due to the high heart rates. 1st pass imaging in the mouse heart became indeed only feasible by the use of accelerated acquisition techniques [7, 8]. Bolus injection volumes in the mouse are of the order of 100 μL injected at a flow rate of 2 mL/min [31]. A second difficulty is given by the high capillary blood flow itself, which produces rather sharp signal increases during first pass. This makes the deconvolution techniques used for perfusion quantification less reliable. Nevertheless, an important advantage of first-pass techniques is their speed. Reported acquisition times are of the order of 60 s in the mouse heart [32].
For ASL-CMR in the rodent heart, the short blood traveling times and high capillary blood flow are beneficial, since the signal used for quantification is directly proportional to MBF. It does not suffer from limitations related to bolus sharpness and reproducibility, since the generated magnetic labeling zone has a perfectly defined shape and negligible duration. Since the labeling can be unconditionally repeated, k-space acquisition can be segmented, and the spatial resolution is therefore not limited by acquisition speed requirements. However, even with the high MBF in rodents, the produced contrast (approximately 20 %) is still much lower than that produced by GBCA. Both the segmentation used for producing high-resolution images and the comparatively small signal therefore lead to long acquisition times compared with first-pass CMR; 4–20 min have been reported [3336]. In humans, ASL-CMR is more challenging given the lower blood flow values and heart rates. Also, since respiration gating in humans is not as regular and reliable as in animals, the scans are in general performed under breath-hold, which limits the available acquisition time.

ASL-CMR in rodents

The feasibility of ASL was first demonstrated in the rodent brain [27, 37], and application to the perfused excised rat heart was also in the focus of the very first ASL studies [38]. Since then, a significant amount of work has been carried out on methods for ASL-CMR in rodents in vivo.
Most studies have used the flow-sensitive alternating inversion recovery (FAIR) scheme [39] consisting of a pair of global and slice-selective inversion recovery experiments Fig. 2. Combined with a Look-Locker readout scheme (LLFAIR), absolute MBF quantification was shown feasible by comparison of T1 relaxation times measured with both experiments. The first successful report of MBF mapping in rats by Belle et al. [33] employed a LLFAIR snapshot-FLASH approach. These authors used a two-compartment quantification model that was initially setup with the goal to correct for errors induced by perfusion on myocardial blood volume measurements [40, 41], and which resulted in a slightly modified relation between perfusion and slice-selective and global inversion tissue T1 values from the initial Detre relation [27]. The study was done in animals under artificial respiration that was arrested during image acquisition to avoid artifacts.
More recent efforts have improved the robustness of MBF quantification using a respiration- and ECG-gated LLFAIRGE single-gradient echo technique [34, 42], which allowed for higher spatial resolutions, freely breathing animals and reduced blurring. These improvements were particularly useful in the mouse heart, which features very high heart rates making snapshot acquisitions prone to blurring [43]. As a drawback, this led to significantly increased measurement times of about 25 min. An example showing the magnetization recovery for two different regions of interest in a mouse is shown in Fig. 3. It can be seen that the Look-Locker approach is advantageous in a small animal context, since – owing to the high heart rate - magnetization recovery can be sampled with good temporal resolution. One more recent improvement of LLFAIRGE incorporated better handling of respiratory motion and heart rate variations using fuzzy C-means clustering but did not shorten the acquisition duration [44].
Campbell-Washburn et al. have suggested several improvements of LLFAIRGE. A segmented k-space acquisition was done using a data logger in addition for recording individual repetition times [35]. The same group also showed the feasibility of multi-slice ASL in mice [45] using a segmented LLFAIR method, in which they also concentrated on ways to take into account the influence of partial saturation of the LV chamber blood by the image acquisition itself. Finally, a detailed analysis of potential error sources in LLFAIR measurements has recently been published by Kampf et al. [46].
Abeykoon et al. [47] proposed a single-inversion-time FAIR-ASL method instead of the T1-based methods used beforehand. Similar approaches had been used earlier, but in the human heart [48]. In the mouse heart, the authors found lower standard deviations within myocardial regions of interest on the perfusion maps than with the well-established LLFAIRGE technique, while absolute quantification of MBF led to similar values.
The FAIR technique is a pulsed ASL (PASL) technique, which has limited acquisition efficiency compared with the continuous ASL (CASL) techniques well known from brain studies [37]. To benefit from the sensitivity advantages of CASL in CMR applications, a steady-pulsed ASL (spASL) scheme using a cine readout incorporating one labeling pulse per cardiac cycle (cine-ASL) was suggested [36, 49]. This steady-pulsed ASL method was shown to allow shorter acquisition times (8 min) than the LLFAIR technique while preserving signal to noise ratio, spatial resolution and robustness with respect to cardiac motion, since no k-space segmentation was used. Unlike other continuous ASL techniques, a drawback of cine-ASL is that a separate T1 measurement is necessary for absolute quantification, but it is an efficient technique in particular when repeated measurements are required during a single exam, such as in rest/stress comparisons. This technique was also shown to be able to detect perfusion variations across the cardiac cycle [50].

Validation studies

All small animal ASL-CMR validation studies to-date were performed in rats. Waller et al. [51] provided validation of the snapshot-FLASH FAIR Look Locker technique against microspheres in pentobarbital-anesthetized rats at rest and under adenosine stress and found good correlation between both techniques. Jacquier et al. [52] validated the LLFAIRGE technique in rats under isoflurane anesthesia at rest and under stress, although in two different groups of animals undergoing MRI and microsphere surgery. The latter study reported much larger perfusion reserve and MBF, which was attributed to the differences in the anesthetics used. However, quantitative MBF values were similar between microspheres and ASL-CMR.

First-pass CMR in rodents

Despite the technical challenges, small-animal first-pass bolus tracking techniques were recently shown feasible thanks to efforts made in accelerating image acquisition. Makowski et al. [53] introduced a k-t SENSE technique for rodent myocardial blood flow (MBF) measurements on a clinical 3 T scanner. First-pass CMR was performed based on a saturation recovery spoiled gradient echo method with 10-fold k-space and time domain undersampling (k-t PCA, [54]), and the technique was validated in healthy mice by comparison with fluorescent microspheres [55] at rest and during dipyridamole-induced vasodilator stress. In parallel, Coolen et al. [32] proposed another approach using a four-element detection coil and GRAPPA k-space acceleration allowing for semi-quantitative assessment of the myocardial perfusion status. Naresh and coworkers recently used BLOSM-accelerated 1st pass CMR to study myocardial blood flow in a high-sucrose diet diabetic mouse model [56]. The same group has provided a systematic comparison of this approach with a FAIR Look-Locker technique in terms of image quality, quantification and reproducibility [57].

Performance

Among the published methods, it is difficult to identify a method of choice in general terms. Table 3 provides an overview over the major published methods along with their advantages and drawbacks. In a recent study by Naresh et al. [57], a BLOSM-accelerated 1st pass technique was compared with a FAIR-spiral ASL technique pointing out that 1st pass CMR had advantages in low blood flow situations whereas ASL gave better perfusion mapping quality and better reproducibility when high blood flow was high.
Table 3
Rodent ASL-CMR methods used in different studies along with their advantages and drawbacks
Method
Post-processing
Advantages
Drawbacks
Author
LLFAIR-snap
T1 sl / T1 gl maps
pixel fit
sat. correction
short acq. time
good accuracy
T1 map included
low res.
low SNR
Belle [33], Waller [51, 58], Hiller [104]
Seg. LLFAIR LLFAIRGE
T1 sl / T1 gl maps
pixel fit
sat. correction
high res.
good accuracy
T1 map included
long acq. time
Kober [34, 42] Campbell-Washburn [35, 45], Streif [43], Vandsburger [44, 60], Caudron [61]
FAIR-1TI
difference image
short acq. time
unknown T1
Abeykoon [47]
cine-ASL
difference image
short acq. time
high res.
cine aspect
unknown T1
unknown
labeling
efficiency
Troalen [36, 50]

Interesting recent findings

There are a number of examples using ASL in rodent models of cardiovascular disease. The topic of infarction and the role of microcirculation in infarction has been extensively studied particularly in rat models [51, 58, 59]. Among the more recent ones, Vandsburger et al. [60] have studied MBF along with many other parameters including regional function in a nNOS-/- knockout mouse model. They found normal perfusion reserve under β-adrenergic stimulation despite a severely altered functional response. In another study, both relaxation times and perfusion were analyzed in spontaneously hypertensive rats at various stages of the disease [61]. Along with correlations of T1 and T2 with fibrotic content obtained by histology, the authors showed that MBF decreased in hypertensive rats without any correlation between perfusion and capillary density of the myocardium. Namely, anti-hypertensive therapy was shown to produce a significant improvement of myocardial perfusion in this model.
Several studies focusing on the infarcted heart made use of LLFAIR ASL. For example, the impact of endothelial cell transplantation in the infarcted myocardium was investigated by Zhang et al. [62]. MBF was quantified with and without transplantation of human endothelial cells into the infarcted heart, and a significant perfusion increase was observed in the treated hearts. This perfusion improvement was thus accompanied by an increase of microvasculature density in the infarcted regions. ASL CMR was also able to show improved myocardial perfusion after myocardial infarction in mice with PTP1B deficiency. The improved perfusion was likely due to an enhancement of angiogenesis in this genetically modified mouse model [63].
Absolute MBF quantification using LLFAIR was shown to be a unique and sensitive index to evaluate therapy in rodent heart disease models. Another therapy based on soluble epoxide hydrolase inhibition, which increases cardiovascular protective acids, has been shown to exert beneficial effects in a chronic heart failure model [64]. Increased perfusion in infarcted myocardium was found to be a short-term process preceding the long-term effects of LV remodeling. In a study exploring overstimulation of the rat heart by chronic infusion of isoproterenol, perfusion was shown to accompany the strong workload increase only temporarily, such that a chronic mismatch between workload and oxygen supply occurred, which resulted in reduced cardiac performance after one week of isoproterenol administration [65] (Fig. 4). More recently, the quantification capabilities of ASL have been used in a longitudinal study using multiple CMR modalities in a high-fat high-sucrose mouse model of type 2 diabetes [66] to monitor microvascular changes induced by the modified diet.

ASL-CMR in large animals and humans

A different set of ASL pulse sequences are used in large animals and humans because of their vastly lower heart rates and perfusion when compared to small animals; these sequences are summarized in Table 4.
Table 4
Large Animal and Human ASL-CMR methods used in different studies. To date, with exception of the spASL technique, all studies used the FAIR labeling approach combined with different readout strategies
Author
Year
Post-labeling delay
Labeling method
Imaging method
Quantification
Capron [75]
2014
HR dependent
spASL
bSSFP
spASL
Wang [20]
2010
200 - 1700 ms
FAIR
bSSFP
Signal Difference
Zun [48]
2009
1 RR
FAIR
bSSFP
Signal Difference
Northrup [76]
2007
(1-12)RR + 91-177 ms
FAIR
GRE
Dual T1
Wacker [69]
2003
100 -1400 ms
FAIR-sat
FLASH
Dual T1
Poncelet [67]
1999
1 RR
FAIR
EPI
Signal Difference
The first published ASL studies in the human heart were independently carried out by Poncelet et al. [67] and Wacker et al. [68]. Poncelet et al. used a FAIR-EPI technique on a clinical 3 T system with a single-loop receive coil. Two cardiac-gated EPI readouts were performed after slice-selective and global inversion pulses, and the individual inversion times were recorded and used in the quantification model. The authors used the original quantification model by Detre et al. [27] approximating relaxation times of blood and tissue as equal. Physiological noise was assessed and considered as a major challenge. The sequence was also used in pigs under rest and stress conditions, and the ASL results were compared with microspheres showing a moderate correlation. As a result, the technique was considered to give reliable measurements, but only under pharmacologic stress conditions, in which blood flow is high. In parallel, Wacker and coworkers published ASL-CMR data from humans using a saturation-recovery snapshot FLASH technique at 1.5 T using a 4-channel array. They performed 9 cardiac-gated readouts per slice-selective or global saturation and used a slightly modified approach for quantification via fitted global and slice-selective T1 values [33]. In a second study, Wacker et al. [69] used a similar technique at 2 Tesla in CAD patients and were able to show reduced perfusion reserve in affected myocardial territories.
Zun et al. [48] later provided an experimental measurement metric for physiological noise based on signal variation across repetitions. They employed a single-TI FAIR bSSFP technique at 3 T. Wang et al. [20] employed a similar but navigator-gated approach with FAIR labeling under free breathing conditions. They used a non-rigid motion correction algorithm inspired from 1st pass CMR perfusion sequences to correct for residual motion [70]. The sequence was performed at multiple labeling delay times to allow for simultaneous quantification of myocardial blood flow and arterial transit time (ATT). They reported resting perfusion values that compared favorably with perfusion values reported in the literature from PET [71, 72] and first-pass perfusion MRI [73]. Miyazaki et al. adapted a time-spatial inversion pulse (time-SLIP) for non-contrast angiography to ASL perfusion at multiple labeling delay times followed by 3D bSSFP imaging [74]. In the labeled condition, a non-selective inversion was followed by a slice-selective inversion centered on the aortic root while in the control condition, a single non-selective inversion pulse was used. They observed a transit time of 200–400 ms from the aortic root to the imaging volume.
A new free-breathing labeling scheme called steady pulsed ASL (spASL) was developed by Capron et al. [75] for the heart that brought the advantage of high signal to noise found in continuous ASL to a pulsed ASL technique. Labeling and snapshot bSSFP imaging were performed every cardiac cycle during end-systole and mid-diastole respectively to drive the perfusion signal to a steady state. Two cardiac gated image series were acquired under labeled and control conditions. The labeling slab was placed at the coronary root while the control slab was placed symmetrically about the imaging slice in a manner similar to EPISTAR. The authors found that spASL had higher SNR compared to FAIR while maintaining similar perfusion quantification. The spASL method will, however, require further improvements regarding motion management of labeling and acquisition to become fully efficient.

Myocardial Blood Flow (MBF) quantification

Quantification of FAIR ASL falls into two main categories that either use a signal intensity difference method or a dual T1 approach. Two variations of the difference method have emerged. In its original implementation, both the labeling pulse and the image acquisition were gated to the same cardiac phase in consecutive heartbeats. While this ensured that labeling and image acquisition excited the same volume of heart, it also introduced a changing labeling time (TI) from heart rate variation that prevents direct subtraction of global and slice-selective image pairs. Instead, myocardial data along with two additional images at a short and long TI were fit to a three parameter inversion recovery model to generate a global and a slice-selective inversion recovery curve [67]. The signal difference was subsequently extrapolated at the average labeling time.
Zun et al. [48] and Wang et al. [20] used a simplified version of the difference method that kept the TI constant between pairs of control and slice-selective images [48]. The pulse sequence they used is shown in Fig. 5. While this allows for direct subtraction of image pairs, it is more susceptible to quantification errors when heart rate variations are ≥ 4 bpm between image pairs (unpublished data). Wang et al. [20] found that non-rigid motion correction was able to mitigate quantification error and improve reliability.
The dual T1 approach to perfusion quantification was first formulated by Detre et al. [27] and experimentally verified by Bauer et al. [41] in an isolated perfused cardioplegic rat heart. Wacker et al. [69] used a saturation recovery FLASH sequence at nine different saturation delays for T1 quantification. They reported overestimated perfusion values, potentially related to the fact that the labeling saturation was done in varying cardiac phases. Northrup et al. [76] used a Look-Locker inversion recovery sequence to ensure that labeling and imaging occurred in the same cardiac phase. However, the authors noted that in a study by Zhou et. al [77], dual T1 quantification can either underestimate or overestimate FAIR perfusion in the presence of transit delay while the difference approach can only underestimate perfusion.
Quantification of perfusion with spASL [49] takes into account the influence of multiple labeling pulses that are applied to blood as it travels from the left ventricular blood pool to the capillary bed of the myocardium. The steady state signal evolution changes depending on the image acquisition scheme and is incorporated into the quantification equation. By acquiring a large number of images, images that are mistriggered or corrupted by respiratory motion can be rejected. Figure 6 compares the pulse sequence of spASL and FAIR.

Registration

Image registration has proven to be an important step in the analysis of ASL-CMR images, primarily because it is a subtraction technique, so small spatial errors can result in errors in perfusion quantification and/or increased physiological noise. This is very important during free-breathing acquisitions [20], but also has benefits during breath-held acquisitions [78]. There are a variety of established techniques for registering CMR images that can be directly applied to ASL-CMR images [7982].

Performance/interesting findings

In large animals, MBF measurements based on FAIR Look-Locker gradient-echo ASL-CMR have correlated well with microsphere histology [83]. Zhang et al. measured perfusion at rest and under dipyridamole induce stress in two healthy dogs and four dogs with 70 % occlusion to the left circumflex artery. Correlation between MRI and microsphere measured perfusion were 0.9 and 0.63 for myocardium supplied by normal and stenotic vessels respectively.
To date, ASL-CMR in humans has not been validated against a gold standard such as PET. However, resting values have correlated well with PET literature, and the expected signal increases with stress have been observed. In particular, 30–40 % increases [84] were observed with isometric handgrip or leg elevation and 3–5x increases [85] were observed with vasodilation via intravenous adenosine. Zun et al. [86] performed ASL-CMR in both healthy human volunteers and patients with suspected CAD and reported clinically relevant changes in myocardial blood flow with vasodilation. Myocardial territories with low perfusion reserve (MBFstress/MBFrest) were also validated with coronary angiography. Two examples of CAD within the LAD and RCA found by ASL-CMR with their corresponding coronary angiograms are shown in Fig. 7. Perfusion reserve in normal and ischemic myocardial perfusion territories in 11 patients are shown in Fig. 8.
Northrup et al. [76] repeated ASL-CMR scans at 1.5 T and 3 T, and showed that although 3 T provided higher SNR (signal-to-thermal-noise ratio), it did not provide higher temporal SNR (signal-to-physiological-noise ratio). This interesting study suggests that unresolved sources of physiological noise limit sensitivity of ASL-CMR; an idea that was confirmed by a recent finding that shortening the imaging window via parallel imaging provides improved temporal SNR despite lower SNR [87]. Physiological noise remains as one of the important factors limiting sensitivity of the technique. Even small amounts of cardiac or respiratory motion can significantly corrupt the ASL difference image because inflowing blood signal is significantly smaller than background myocardial tissue signal. Most studies have tried to reduce physiological noise from cardiac and respiratory motion through breath-held, rapid single shot imaging during a stable cardiac phase. Physiological noise is measured as the variance of MBF from individual control and labeled image pairs. This calculation is straightforward using the signal intensity difference method at a single TI. Zun et al. [48] reported that physiological noise was 0.23 ml/g/min in 15 healthy volunteers. Physiological noise using the dual T1 approach is not directly measured because MBF from individual image pairs are never determined. Instead a surrogate for physiological noise is calculated from residuals of T1 curve fitting.

Open questions

Absolute quantification and error sources

Quantification is a strength of ASL-CMR compared to first-pass techniques. The models as well as the post-processing algorithms are comparatively simple, since only water molecules are involved in the process, and since the labeling pulses create a perfectly reproducible bolus of well-known shape that is placed close to the imaged region. However, some uncertainties remain. Among them, the arterial transit time (ATT) from the labeled region to the entry of the capillary system may vary as a function of physiology. ATT becomes a significant source of error when it is much longer than the labeling delay time. Multi-delay protocols mitigate this source of error and can derive both ATT and MBF [20, 74]. The labeling efficiency affects the absolute MBF calculation in a direct proportional way. While variations of the labeling efficiency are likely negligible for the FAIR technique, the spASL technique is more prone to such errors. Other error sources are potential variations in T1 of tissue and blood if they are not measured along with perfusion. T1 variations in blood may be caused by differences in hematocrit.

Complete coverage during stress

Current large animal and human ASL-CMR methods can capture a single slice in roughly 3 min of scan time. This has made it difficult to perform a comprehensive evaluation of ischemic disease which would require covering all coronary territories during the typical duration of peak vasodilation during a pharmacologic stress test (roughly 3 min for adenosine, less for regadenosin). The use of accelerated acquisition schemes including simultaneous multislice imaging [88, 89] or undersampled 3D acquisition [9092] may be able to address this current limitation.

High field imaging

Due to the increasing T1 with field strength, the life time of the magnetic labeling increases as well, and ASL is therefore a technique doubly benefiting from higher field in theory. This advantage is, however, compromised and yet unclear when considering the important contribution of physiological noise identified earlier [48, 76]. Whether high or even ultra-high field strengths (≥7 Tesla) can be used in a beneficial way for ASL-CMR will strongly depend on the ability of reducing motion contributions to signal variations observed in the myocardium.

Motion correction

Beyond the most widely used ECG-triggered acquisition under breath-hold, available motion management techniques include post-processing image registration (rigid or non-rigid), but also advanced real-time techniques like motion tracking using a navigator. In ASL-CMR, motion tracking may be applied not only to the imaging slice, but it might also be useful to specific labeling volumes such as 2D spatial RF inversions [93]. Finally, advanced acquisition-reconstruction strategies like the Generalized Reconstruction by Inversion of Coupled Systems (GRICS) framework [94] directly integrate motion information collected during the acquisition into the reconstruction model and may be a way towards more efficient ASL-CMR acquisitions in the future.

Clinical applications

Due to its unlimited repeatability, ASL-CMR is an excellent candidate for perfusion stress testing. The technique can be used to assess and quantify regional myocardial perfusion and perfusion reserve in CKD or ESRD patients who suffer from higher rates of cardiovascular events, but cannot tolerate contrast agents required by other perfusion imaging techniques. However, challenges in applying ASL methods in the clinical setting remain. Current ASL methods require precise timing of labeling and imaging to the cardiac cycle, which is difficult to perform in the setting of cardiac arrhythmias. Developments in self gated, ECG free CINE imaging can be applied to ASL to help overcome this limitation [95, 96]. In disease processes with extremely low coronary flow such as in heart failure, severe coronary stenosis, or high coronary collateralization, ATT may be much longer that the labeling delay resulting in marked loss of the ASL signal. Velocity selective arterial spin labeling, which is insensitive to ATT by labeling blood based on its velocity within the arterioles adjacent to tissue, have been used successfully in the brain to and may be adapted for cardiac ASL [97, 98]. While not a direct measurement for viability and scar, ASL can potentially detect regions of hypo-perfusion associated with scar and can become a surrogate for scar localization with improvements in the spatial resolution of the technique. Figure 9 shows that rest ASL-CMR is comparable with rest first-pass CMR at detecting scar in a porcine model of myocardial infarction [99]. Finally, ASL-CMR may be used to assess diffuse disease processes such as coronary microvascular disease and diffuse interstitial fibrosis that result from diabetes, hypertension, and cardiomyopathy because it interrogates tissue perfusion directly.

Conclusion

ASL-CMR is a safe technique for mapping regional myocardial perfusion and perfusion reserve. It does not require any contrast agents, is compatible with stress testing, and can be performed repeatedly and even continuously, with no incremental risk to the subject. ASL-CMR has been performed with great success in small-animals, and is the current method of choice when overall scan time is not a constraint. Its application to large animals and humans has been limited primarily by physiological noise (per-segment measurement variation approximately ±0.2 ml/g/min). It remains an active area of research, with many possible solutions on the horizon. Successful developments in brain ASL and small-animal ASL-CMR have helped to inform many of the most recent developments in large animal and human ASL-CMR.

Acknowledgements

We thank our many collaborators and funding sources. F.K. and T.T. thank Thibaut Capron, Julien Pugnaire, Monique Bernard, and funding from Centre National de la Recherche Scientifique (CNRS-UMR7339), Agence Nationale de la Recherche (ANR-14-CE17-0016-01 COFLORES) and Fondation de la Recherche Médicale (DBS20140930772). K.S.N. and T.J. thank Zungho Zun, Eric Wong, Gerald Pohost, Ramdas Pai, Padmini Varadarajan, Hung Phi Do, Vanessa Landes, Ahsan Javed, Andrew Yoon, and funding from the Wallace H. Coulter Foundation (Phase 1 and Phase 2 Translational Research Award) and American Heart Association (#13GRNT13850012). We acknowledge support from the Visitor Program of the Ming Hsieh Institute of the University of Southern California.
Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://​creativecommons.​org/​licenses/​by/​4.​0/​), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://​creativecommons.​org/​publicdomain/​zero/​1.​0/​) applies to the data made available in this article, unless otherwise stated.

Competing interests

The authors declare that they have no competing interests.

Authors’ contribution

FK: manuscript design, drafting, and revision, literature review, coordination among co-authors, final revisions. TJ: literature review, manuscript drafting and revision. TT: literature review, manuscript drafting and revision. KN: manuscript design, drafting, and revision, literature review, coordination among co-authors. All authors read and approved the manuscript.
Literatur
1.
Zurück zum Zitat Calamante F, Thomas DL, Pell GS, Wiersma J, Turner R. Measuring cerebral blood flow using magnetic resonance imaging techniques. J Cereb Blood Flow Metab. 1999;19:701–35.CrossRefPubMed Calamante F, Thomas DL, Pell GS, Wiersma J, Turner R. Measuring cerebral blood flow using magnetic resonance imaging techniques. J Cereb Blood Flow Metab. 1999;19:701–35.CrossRefPubMed
2.
Zurück zum Zitat Wolf RL, Detre JA. Clinical neuroimaging using arterial spin-labeled perfusion magnetic resonance imaging. Neurother J Am Soc Exp Neurother. 2007;4:346–59.CrossRef Wolf RL, Detre JA. Clinical neuroimaging using arterial spin-labeled perfusion magnetic resonance imaging. Neurother J Am Soc Exp Neurother. 2007;4:346–59.CrossRef
3.
Zurück zum Zitat Klocke FJ, Baird MG, Lorell BH, Bateman TM, Messer JV, Berman DS, O’Gara PT, Carabello BA, Russell RO, Cerqueira MD, St John Sutton MG, DeMaria AN, Udelson JE, Kennedy JW, Verani MS,Williams KA, Antman EM, Smith SC, Alpert JS, Gregoratos G, Anderson JL, Hiratzka LF, Faxon DP,Hunt SA, Fuster V, Jacobs AK, Gibbons RJ, Russell RO, American College of Cardiology, American Heart Association, et al. ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging--executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to Revise the 1995 Guidelines for the Clinical Use of Cardiac Radionuclide Imaging). J Am Coll Cardiol. 2003;42:1318–33. Klocke FJ, Baird MG, Lorell BH, Bateman TM, Messer JV, Berman DS, O’Gara PT, Carabello BA, Russell RO, Cerqueira MD, St John Sutton MG, DeMaria AN, Udelson JE, Kennedy JW, Verani MS,Williams KA, Antman EM, Smith SC, Alpert JS, Gregoratos G, Anderson JL, Hiratzka LF, Faxon DP,Hunt SA, Fuster V, Jacobs AK, Gibbons RJ, Russell RO, American College of Cardiology, American Heart Association, et al. ACC/AHA/ASNC guidelines for the clinical use of cardiac radionuclide imaging--executive summary: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASNC Committee to Revise the 1995 Guidelines for the Clinical Use of Cardiac Radionuclide Imaging). J Am Coll Cardiol. 2003;42:1318–33.
4.
Zurück zum Zitat Ragosta M, Bishop AH, Lipson LC, Watson DD, Gimple LW, Sarembock IJ, Powers ER. Comparison between angiography and fractional flow reserve versus single-photon emission computed tomographic myocardial perfusion imaging for determining lesion significance in patients with multivessel coronary disease. Am J Cardiol. 2007;99:896–902.CrossRefPubMed Ragosta M, Bishop AH, Lipson LC, Watson DD, Gimple LW, Sarembock IJ, Powers ER. Comparison between angiography and fractional flow reserve versus single-photon emission computed tomographic myocardial perfusion imaging for determining lesion significance in patients with multivessel coronary disease. Am J Cardiol. 2007;99:896–902.CrossRefPubMed
5.
Zurück zum Zitat Gerber BL, Raman SV, Nayak K, Epstein FH, Ferreira P, Axel L, Kraitchman DL. Myocardial first-pass perfusion cardiovascular magnetic resonance: history, theory, and current state of the art. J Cardiovasc Magn Reson. 2008;10:18.CrossRefPubMedPubMedCentral Gerber BL, Raman SV, Nayak K, Epstein FH, Ferreira P, Axel L, Kraitchman DL. Myocardial first-pass perfusion cardiovascular magnetic resonance: history, theory, and current state of the art. J Cardiovasc Magn Reson. 2008;10:18.CrossRefPubMedPubMedCentral
6.
Zurück zum Zitat Schwitter J, Wacker CM, Wilke N, Al-Saadi N, Sauer E, Huettle K, Schönberg SO, Debl K, Strohm O, Ahlstrom H, Dill T, Hoebel N, Simor T, MR-IMPACT investigators. Superior diagnostic performance of perfusion-cardiovascular magnetic resonance versus SPECT to detect coronary artery disease: The secondary endpoints of the multicenter multivendor MR-IMPACT II (Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary Artery Disease Trial). J Cardiovasc Magn Reson. 2012;14:61.CrossRefPubMedPubMedCentral Schwitter J, Wacker CM, Wilke N, Al-Saadi N, Sauer E, Huettle K, Schönberg SO, Debl K, Strohm O, Ahlstrom H, Dill T, Hoebel N, Simor T, MR-IMPACT investigators. Superior diagnostic performance of perfusion-cardiovascular magnetic resonance versus SPECT to detect coronary artery disease: The secondary endpoints of the multicenter multivendor MR-IMPACT II (Magnetic Resonance Imaging for Myocardial Perfusion Assessment in Coronary Artery Disease Trial). J Cardiovasc Magn Reson. 2012;14:61.CrossRefPubMedPubMedCentral
7.
Zurück zum Zitat Schwitter J, Wacker CM, Wilke N, Al-Saadi N, Sauer E, Huettle K, Schönberg SO, Luchner A, Strohm O, Ahlstrom H, Dill T, Hoebel N, Simor T, MR-IMPACT Investigators. MR-IMPACT II: Magnetic resonance imaging for myocardial perfusion assessment in coronary artery disease trial: perfusion-cardiac magnetic resonance vs. single-photon emission computed tomography for the detection of coronary artery disease: a comparative multicentre, multivendor trial. Eur Heart J. 2013;34:775–81.CrossRefPubMed Schwitter J, Wacker CM, Wilke N, Al-Saadi N, Sauer E, Huettle K, Schönberg SO, Luchner A, Strohm O, Ahlstrom H, Dill T, Hoebel N, Simor T, MR-IMPACT Investigators. MR-IMPACT II: Magnetic resonance imaging for myocardial perfusion assessment in coronary artery disease trial: perfusion-cardiac magnetic resonance vs. single-photon emission computed tomography for the detection of coronary artery disease: a comparative multicentre, multivendor trial. Eur Heart J. 2013;34:775–81.CrossRefPubMed
8.
Zurück zum Zitat Greenwood JP, Maredia N, Younger JF, Brown JM, Nixon J, Everett CC, Bijsterveld P, Ridgway JP, Radjenovic A, Dickinson CJ, Ball SG, Plein S. Cardiovascular magnetic resonance and single-photon emission computed tomography for diagnosis of coronary heart disease (CE-MARC): a prospective trial. Lancet Lond Engl. 2012;379:453–60.CrossRef Greenwood JP, Maredia N, Younger JF, Brown JM, Nixon J, Everett CC, Bijsterveld P, Ridgway JP, Radjenovic A, Dickinson CJ, Ball SG, Plein S. Cardiovascular magnetic resonance and single-photon emission computed tomography for diagnosis of coronary heart disease (CE-MARC): a prospective trial. Lancet Lond Engl. 2012;379:453–60.CrossRef
9.
Zurück zum Zitat Ritter CO, Wilke A, Wichmann T, Beer M, Hahn D, Köstler H. Comparison of intravascular and extracellular contrast media for absolute quantification of myocardial rest-perfusion using high-resolution MRI. J Magn Reson Imaging. 2011;33:1047–51.CrossRefPubMed Ritter CO, Wilke A, Wichmann T, Beer M, Hahn D, Köstler H. Comparison of intravascular and extracellular contrast media for absolute quantification of myocardial rest-perfusion using high-resolution MRI. J Magn Reson Imaging. 2011;33:1047–51.CrossRefPubMed
10.
Zurück zum Zitat Gatehouse PD, Elkington AG, Ablitt NA, Yang G-Z, Pennell DJ, Firmin DN. Accurate assessment of the arterial input function during high-dose myocardial perfusion cardiovascular magnetic resonance. J Magn Reson Imaging JMRI. 2004;20:39–45.CrossRefPubMed Gatehouse PD, Elkington AG, Ablitt NA, Yang G-Z, Pennell DJ, Firmin DN. Accurate assessment of the arterial input function during high-dose myocardial perfusion cardiovascular magnetic resonance. J Magn Reson Imaging JMRI. 2004;20:39–45.CrossRefPubMed
11.
Zurück zum Zitat Ishida M, Schuster A, Morton G, Chiribiri A, Hussain S, Paul M, Merkle N, Steen H, Lossnitzer D, Schnackenburg B, Alfakih K, Plein S, Nagel E. Development of a universal dual-bolus injection scheme for the quantitative assessment of myocardial perfusion cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2011;13:28.CrossRefPubMedPubMedCentral Ishida M, Schuster A, Morton G, Chiribiri A, Hussain S, Paul M, Merkle N, Steen H, Lossnitzer D, Schnackenburg B, Alfakih K, Plein S, Nagel E. Development of a universal dual-bolus injection scheme for the quantitative assessment of myocardial perfusion cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2011;13:28.CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Larghat AM, Maredia N, Biglands J, Greenwood JP, Ball SG, Jerosch-Herold M, Radjenovic A, Plein S. Reproducibility of first-pass cardiovascular magnetic resonance myocardial perfusion. J Magn Reson Imaging JMRI. 2013;37:865–74.CrossRefPubMed Larghat AM, Maredia N, Biglands J, Greenwood JP, Ball SG, Jerosch-Herold M, Radjenovic A, Plein S. Reproducibility of first-pass cardiovascular magnetic resonance myocardial perfusion. J Magn Reson Imaging JMRI. 2013;37:865–74.CrossRefPubMed
15.
Zurück zum Zitat Di Angelantonio E. Chronic kidney disease and risk of major cardiovascular disease and non-vascular mortality: prospective population based cohort study. BMJ. 2010;341:c4986.CrossRefPubMedPubMedCentral Di Angelantonio E. Chronic kidney disease and risk of major cardiovascular disease and non-vascular mortality: prospective population based cohort study. BMJ. 2010;341:c4986.CrossRefPubMedPubMedCentral
16.
Zurück zum Zitat Go AS, Chertow GM, Fan D, McCulloch CE, Hsu C. Chronic kidney disease and the risks of death, cardiovascular events, and hospitalization. N Engl J Med. 2004;351:1296–305.CrossRefPubMed Go AS, Chertow GM, Fan D, McCulloch CE, Hsu C. Chronic kidney disease and the risks of death, cardiovascular events, and hospitalization. N Engl J Med. 2004;351:1296–305.CrossRefPubMed
17.
Zurück zum Zitat Cerqueira MD, Allman KC, Ficaro EP, Hansen CL, Nichols KJ, Thompson RC, Van Decker WA, Yakovlevitch M. Recommendations for reducing radiation exposure in myocardial perfusion imaging. J Nucl Cardiol. 2010;17:709–18.CrossRefPubMed Cerqueira MD, Allman KC, Ficaro EP, Hansen CL, Nichols KJ, Thompson RC, Van Decker WA, Yakovlevitch M. Recommendations for reducing radiation exposure in myocardial perfusion imaging. J Nucl Cardiol. 2010;17:709–18.CrossRefPubMed
18.
Zurück zum Zitat Fazel R, Dilsizian V, Einstein AJ, Ficaro EP, Henzlova M, Shaw LJ. Strategies for defining an optimal risk-benefit ratio for stress myocardial perfusion SPECT. J Nucl Cardiol. 2011;18:385–92.CrossRefPubMed Fazel R, Dilsizian V, Einstein AJ, Ficaro EP, Henzlova M, Shaw LJ. Strategies for defining an optimal risk-benefit ratio for stress myocardial perfusion SPECT. J Nucl Cardiol. 2011;18:385–92.CrossRefPubMed
20.
Zurück zum Zitat Wang DJ, Bi X, Avants BB, Meng T, Zuehlsdorff S, Detre JA. Estimation of perfusion and arterial transit time in myocardium using free-breathing myocardial arterial spin labeling with navigator-echo. Magn Reson Med. 2010;64:1289–95.CrossRefPubMedPubMedCentral Wang DJ, Bi X, Avants BB, Meng T, Zuehlsdorff S, Detre JA. Estimation of perfusion and arterial transit time in myocardium using free-breathing myocardial arterial spin labeling with navigator-echo. Magn Reson Med. 2010;64:1289–95.CrossRefPubMedPubMedCentral
21.
Zurück zum Zitat Bokkers RPH, Hernandez DA, Merino JG, Mirasol RV, van Osch MJ, Hendrikse J, Warach S, Latour LL, National Institutes of Health Stroke Natural History Investigators. Whole-brain arterial spin labeling perfusion MRI in patients with acute stroke. Stroke J Cereb Circ. 2012;43:1290–4.CrossRef Bokkers RPH, Hernandez DA, Merino JG, Mirasol RV, van Osch MJ, Hendrikse J, Warach S, Latour LL, National Institutes of Health Stroke Natural History Investigators. Whole-brain arterial spin labeling perfusion MRI in patients with acute stroke. Stroke J Cereb Circ. 2012;43:1290–4.CrossRef
23.
Zurück zum Zitat Wang J, Aguirre GK, Kimberg DY, Roc AC, Li L, Detre JA. Arterial spin labeling perfusion fMRI with very low task frequency. Magn Reson Med. 2003;49:796–802.CrossRefPubMed Wang J, Aguirre GK, Kimberg DY, Roc AC, Li L, Detre JA. Arterial spin labeling perfusion fMRI with very low task frequency. Magn Reson Med. 2003;49:796–802.CrossRefPubMed
24.
Zurück zum Zitat Yang Y, Engelien W, Xu S, Gu H, Silbersweig DA, Stern E. Transit time, trailing time, and cerebral blood flow during brain activation: Measurement using multislice, pulsed spin-labeling perfusion imaging. Magn Reson Med. 2000;44:680–5.CrossRefPubMed Yang Y, Engelien W, Xu S, Gu H, Silbersweig DA, Stern E. Transit time, trailing time, and cerebral blood flow during brain activation: Measurement using multislice, pulsed spin-labeling perfusion imaging. Magn Reson Med. 2000;44:680–5.CrossRefPubMed
25.
Zurück zum Zitat Gonzalez-At JB, Alsop DC, Detre JA. Cerebral perfusion and arterial transit time changes during task activation determined with continuous arterial spin labeling. Magn Reson Med. 2000;43:739–46.CrossRefPubMed Gonzalez-At JB, Alsop DC, Detre JA. Cerebral perfusion and arterial transit time changes during task activation determined with continuous arterial spin labeling. Magn Reson Med. 2000;43:739–46.CrossRefPubMed
26.
Zurück zum Zitat Alsop DC, Detre JA, Golay X, Günther M, Hendrikse J, Hernandez-Garcia L, Lu H, Macintosh BJ, Parkes LM, Smits M, van Osch MJP, Wang DJJ, Wong EC, Zaharchuk G. Recommended implementation of arterial spin-labeled perfusion MRI for clinical applications: A consensus of the ISMRM perfusion study group and the european consortium for ASL in dementia. Magn Reson Med. 2014;116(October 2013):102–16. Alsop DC, Detre JA, Golay X, Günther M, Hendrikse J, Hernandez-Garcia L, Lu H, Macintosh BJ, Parkes LM, Smits M, van Osch MJP, Wang DJJ, Wong EC, Zaharchuk G. Recommended implementation of arterial spin-labeled perfusion MRI for clinical applications: A consensus of the ISMRM perfusion study group and the european consortium for ASL in dementia. Magn Reson Med. 2014;116(October 2013):102–16.
27.
Zurück zum Zitat Detre JA, Leigh JS, Williams DS, Koretsky AP. Perfusion imaging. Magn Reson Med. 1992;23:37–45.CrossRefPubMed Detre JA, Leigh JS, Williams DS, Koretsky AP. Perfusion imaging. Magn Reson Med. 1992;23:37–45.CrossRefPubMed
28.
Zurück zum Zitat Buxton RB, Frank LR, Wong EC, Siewert B, Warach S, Edelman RR. A general kinetic model for quantitative perfusion imaging with arterial spin labeling. Magn Reson Med. 1998;40:383–96.CrossRefPubMed Buxton RB, Frank LR, Wong EC, Siewert B, Warach S, Edelman RR. A general kinetic model for quantitative perfusion imaging with arterial spin labeling. Magn Reson Med. 1998;40:383–96.CrossRefPubMed
29.
Zurück zum Zitat Wong EC. Quantifying CBF with pulsed ASL: technical and pulse sequence factors. J Magn Reson Imaging JMRI. 2005;22:727–31.CrossRefPubMed Wong EC. Quantifying CBF with pulsed ASL: technical and pulse sequence factors. J Magn Reson Imaging JMRI. 2005;22:727–31.CrossRefPubMed
30.
Zurück zum Zitat Wong EC. An Introduction to ASL Labeling Techniques. J Magn Reson Imaging JMRI. 2014. Wong EC. An Introduction to ASL Labeling Techniques. J Magn Reson Imaging JMRI. 2014.
31.
Zurück zum Zitat van Nierop BJ, Coolen BF, Dijk WJR, Hendriks AD, de Graaf L, Nicolay K, Strijkers GJ. Quantitative first-pass perfusion MRI of the mouse myocardium. Magn Reson Med. 2013;69:1735–44.CrossRefPubMed van Nierop BJ, Coolen BF, Dijk WJR, Hendriks AD, de Graaf L, Nicolay K, Strijkers GJ. Quantitative first-pass perfusion MRI of the mouse myocardium. Magn Reson Med. 2013;69:1735–44.CrossRefPubMed
32.
Zurück zum Zitat Coolen BF, Moonen RP, Paulis LE, Geelen T, Nicolay K, Strijkers GJ. Mouse myocardial first-pass perfusion MR imaging. Magn Reson Med. 2010;64:1658–63.CrossRefPubMed Coolen BF, Moonen RP, Paulis LE, Geelen T, Nicolay K, Strijkers GJ. Mouse myocardial first-pass perfusion MR imaging. Magn Reson Med. 2010;64:1658–63.CrossRefPubMed
33.
Zurück zum Zitat Belle V, Kahler E, Waller C, Rommel E, Voll S, Hiller K, Bauer W, Haase A. In vivo quantitative mapping of cardiac perfusion in rats using a noninvasive MR spin-labeling method. J Magn Reson Imaging. 1998;8:1240–5.CrossRefPubMed Belle V, Kahler E, Waller C, Rommel E, Voll S, Hiller K, Bauer W, Haase A. In vivo quantitative mapping of cardiac perfusion in rats using a noninvasive MR spin-labeling method. J Magn Reson Imaging. 1998;8:1240–5.CrossRefPubMed
34.
Zurück zum Zitat Kober F, Iltis I, Cozzone PJ, Bernard M. Myocardial blood flow mapping in mice using high-resolution spin labeling magnetic resonance imaging: influence of ketamine/xylazine and isoflurane anesthesia. Magn Reson Med. 2005;53:601–6.CrossRefPubMed Kober F, Iltis I, Cozzone PJ, Bernard M. Myocardial blood flow mapping in mice using high-resolution spin labeling magnetic resonance imaging: influence of ketamine/xylazine and isoflurane anesthesia. Magn Reson Med. 2005;53:601–6.CrossRefPubMed
35.
Zurück zum Zitat Campbell-Washburn AE, Price AN, Wells JA, Thomas DL, Ordidge RJ, Lythgoe MF. Cardiac arterial spin labeling using segmented ECG-gated Look-Locker FAIR: variability and repeatability in preclinical studies. Magn Reson Med. 2013;69:238–47.CrossRefPubMed Campbell-Washburn AE, Price AN, Wells JA, Thomas DL, Ordidge RJ, Lythgoe MF. Cardiac arterial spin labeling using segmented ECG-gated Look-Locker FAIR: variability and repeatability in preclinical studies. Magn Reson Med. 2013;69:238–47.CrossRefPubMed
36.
Zurück zum Zitat Troalen T, Capron T, Cozzone PJ, Bernard M, Kober F. Cine-ASL: A steady-pulsed arterial spin labeling method for myocardial perfusion mapping in mice. Part I. Experimental study. Magn Reson Med. 2013;70:1389–98.CrossRefPubMed Troalen T, Capron T, Cozzone PJ, Bernard M, Kober F. Cine-ASL: A steady-pulsed arterial spin labeling method for myocardial perfusion mapping in mice. Part I. Experimental study. Magn Reson Med. 2013;70:1389–98.CrossRefPubMed
37.
Zurück zum Zitat Williams DS, Detre JA, Leigh JS, Koretsky AP. Magnetic resonance imaging of perfusion using spin inversion of arterial water. Proc Natl Acad Sci U A. 1992;89:212–6.CrossRef Williams DS, Detre JA, Leigh JS, Koretsky AP. Magnetic resonance imaging of perfusion using spin inversion of arterial water. Proc Natl Acad Sci U A. 1992;89:212–6.CrossRef
38.
Zurück zum Zitat Williams DS, Grandis DJ, Zhang W, Koretsky AP. Magnetic resonance imaging of perfusion in the isolated rat heart using spin inversion of arterial water. Magn Reson Med. 1993;30:361–5.CrossRefPubMed Williams DS, Grandis DJ, Zhang W, Koretsky AP. Magnetic resonance imaging of perfusion in the isolated rat heart using spin inversion of arterial water. Magn Reson Med. 1993;30:361–5.CrossRefPubMed
39.
Zurück zum Zitat Kim SG. Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping. Magn Reson Med. 1995;34:293–301.CrossRefPubMed Kim SG. Quantification of relative cerebral blood flow change by flow-sensitive alternating inversion recovery (FAIR) technique: application to functional mapping. Magn Reson Med. 1995;34:293–301.CrossRefPubMed
40.
Zurück zum Zitat Bauer WR, Hiller KH, Roder F, Rommel E, Ertl G, Haase A. Magnetization exchange in capillaries by microcirculation affects diffusion-controlled spin-relaxation: a model which describes the effect of perfusion on relaxation enhancement by intravascular contrast agents. Magn Reson Med. 1996;35:43–55.CrossRefPubMed Bauer WR, Hiller KH, Roder F, Rommel E, Ertl G, Haase A. Magnetization exchange in capillaries by microcirculation affects diffusion-controlled spin-relaxation: a model which describes the effect of perfusion on relaxation enhancement by intravascular contrast agents. Magn Reson Med. 1996;35:43–55.CrossRefPubMed
41.
Zurück zum Zitat Bauer WR, Roder F, Hiller KH, Han H, Fröhlich S, Rommel E, Haase A, Ertl G. The effect of perfusion on T1 after slice-selective spin inversion in the isolated cardioplegic rat heart: measurement of a lower bound of intracapillary-extravascular water proton exchange rate. Magn Reson Med. 1997;38:917–23.CrossRefPubMed Bauer WR, Roder F, Hiller KH, Han H, Fröhlich S, Rommel E, Haase A, Ertl G. The effect of perfusion on T1 after slice-selective spin inversion in the isolated cardioplegic rat heart: measurement of a lower bound of intracapillary-extravascular water proton exchange rate. Magn Reson Med. 1997;38:917–23.CrossRefPubMed
42.
Zurück zum Zitat Kober F, Iltis I, Cozzone PJ, Bernard M. Cine-MRI assessment of cardiac function in mice anesthetized with ketamine/xylazine and isoflurane. Magn Reson Mater Phys Biol Med. 2004;17:157–61.CrossRef Kober F, Iltis I, Cozzone PJ, Bernard M. Cine-MRI assessment of cardiac function in mice anesthetized with ketamine/xylazine and isoflurane. Magn Reson Mater Phys Biol Med. 2004;17:157–61.CrossRef
43.
Zurück zum Zitat Streif JU, Nahrendorf M, Hiller KH, Waller C, Wiesmann F, Rommel E, Haase A, Bauer WR. In vivo assessment of absolute perfusion and intracapillary blood volume in the murine myocardium by spin labeling magnetic resonance imaging. Magn Reson Med. 2005;53:584–92.CrossRefPubMed Streif JU, Nahrendorf M, Hiller KH, Waller C, Wiesmann F, Rommel E, Haase A, Bauer WR. In vivo assessment of absolute perfusion and intracapillary blood volume in the murine myocardium by spin labeling magnetic resonance imaging. Magn Reson Med. 2005;53:584–92.CrossRefPubMed
44.
Zurück zum Zitat Vandsburger MH, Janiczek RL, Xu Y, French BA, Meyer CH, Kramer CM, Epstein FH. Improved arterial spin labeling after myocardial infarction in mice using cardiac and respiratory gated look-locker imaging with fuzzy C-means clustering. Magn Reson Med. 2010;63:648–57.CrossRefPubMedPubMedCentral Vandsburger MH, Janiczek RL, Xu Y, French BA, Meyer CH, Kramer CM, Epstein FH. Improved arterial spin labeling after myocardial infarction in mice using cardiac and respiratory gated look-locker imaging with fuzzy C-means clustering. Magn Reson Med. 2010;63:648–57.CrossRefPubMedPubMedCentral
45.
Zurück zum Zitat Campbell-Washburn AE, Zhang H, Siow BM, Price AN, Lythgoe MF, Ordidge RJ, Thomas DL. Multislice cardiac arterial spin labeling using improved myocardial perfusion quantification with simultaneously measured blood pool input function. Magn Reson Med. 2013;70:1125–36.CrossRefPubMed Campbell-Washburn AE, Zhang H, Siow BM, Price AN, Lythgoe MF, Ordidge RJ, Thomas DL. Multislice cardiac arterial spin labeling using improved myocardial perfusion quantification with simultaneously measured blood pool input function. Magn Reson Med. 2013;70:1125–36.CrossRefPubMed
46.
Zurück zum Zitat Kampf T, Helluy X, Gutjahr FT, Winter P, Meyer CB, Jakob PM, Bauer WR, Ziener CH. Myocardial perfusion quantification using the T1-based FAIR-ASL method: The influence of heart anatomy, cardiopulmonary blood flow and look–locker readout. Magn Reson Med. 2013. Kampf T, Helluy X, Gutjahr FT, Winter P, Meyer CB, Jakob PM, Bauer WR, Ziener CH. Myocardial perfusion quantification using the T1-based FAIR-ASL method: The influence of heart anatomy, cardiopulmonary blood flow and look–locker readout. Magn Reson Med. 2013.
47.
Zurück zum Zitat Abeykoon S, Sargent M, Wansapura JP. Quantitative myocardial perfusion in mice based on the signal intensity of flow sensitized CMR. J Cardiovasc Magn Reson. 2012;14:73.CrossRefPubMedPubMedCentral Abeykoon S, Sargent M, Wansapura JP. Quantitative myocardial perfusion in mice based on the signal intensity of flow sensitized CMR. J Cardiovasc Magn Reson. 2012;14:73.CrossRefPubMedPubMedCentral
48.
Zurück zum Zitat Zun Z, Wong EC, Nayak KS. Assessment of myocardial blood flow (MBF) in humans using arterial spin labeling (ASL): Feasibility and noise analysis. Magn Reson Med. 2009;62:975–83.CrossRefPubMed Zun Z, Wong EC, Nayak KS. Assessment of myocardial blood flow (MBF) in humans using arterial spin labeling (ASL): Feasibility and noise analysis. Magn Reson Med. 2009;62:975–83.CrossRefPubMed
49.
Zurück zum Zitat Capron T, Troalen T, Cozzone PJ, Bernard M, Kober F. Cine-ASL: A steady-pulsed arterial spin labeling method for myocardial perfusion mapping in mice. Part II. Theoretical model and sensitivity optimization. Magn Reson Med. 2013;70:1399–408.CrossRefPubMed Capron T, Troalen T, Cozzone PJ, Bernard M, Kober F. Cine-ASL: A steady-pulsed arterial spin labeling method for myocardial perfusion mapping in mice. Part II. Theoretical model and sensitivity optimization. Magn Reson Med. 2013;70:1399–408.CrossRefPubMed
50.
Zurück zum Zitat Troalen T, Capron T, Bernard M, Kober F. In vivo characterization of rodent cyclic myocardial perfusion variation at rest and during adenosine-induced stress using cine-ASL cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2014;16:18.CrossRefPubMedPubMedCentral Troalen T, Capron T, Bernard M, Kober F. In vivo characterization of rodent cyclic myocardial perfusion variation at rest and during adenosine-induced stress using cine-ASL cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2014;16:18.CrossRefPubMedPubMedCentral
51.
Zurück zum Zitat Waller C, Kahler E, Hiller K-H, Hu K, Nahrendorf M, Voll S, Haase A, Ertl G, Bauer WR. Myocardial Perfusion and Intracapillary Blood Volume in Rats at Rest and with Coronary Dilatation: MR Imaging in Vivo with Use of a Spin-Labeling Technique1. Radiology. 2000;215:189–97.CrossRefPubMed Waller C, Kahler E, Hiller K-H, Hu K, Nahrendorf M, Voll S, Haase A, Ertl G, Bauer WR. Myocardial Perfusion and Intracapillary Blood Volume in Rats at Rest and with Coronary Dilatation: MR Imaging in Vivo with Use of a Spin-Labeling Technique1. Radiology. 2000;215:189–97.CrossRefPubMed
52.
Zurück zum Zitat Jacquier A, Kober F, Bun S, Giorgi R, Cozzone PJ, Bernard M. Quantification of myocardial blood flow and flow reserve in rats using arterial spin labeling MRI: comparison with a fluorescent microsphere technique. NMR Biomed. 2011;24:1047–53.CrossRefPubMed Jacquier A, Kober F, Bun S, Giorgi R, Cozzone PJ, Bernard M. Quantification of myocardial blood flow and flow reserve in rats using arterial spin labeling MRI: comparison with a fluorescent microsphere technique. NMR Biomed. 2011;24:1047–53.CrossRefPubMed
53.
Zurück zum Zitat Makowski M, Jansen C, Webb I, Chiribiri A, Nagel E, Botnar R, Kozerke S, Plein S. First-pass contrast-enhanced myocardial perfusion MRI in mice on a 3-T clinical MR scanner. Magn Reson Med. 2010;64:1592–8.CrossRefPubMedPubMedCentral Makowski M, Jansen C, Webb I, Chiribiri A, Nagel E, Botnar R, Kozerke S, Plein S. First-pass contrast-enhanced myocardial perfusion MRI in mice on a 3-T clinical MR scanner. Magn Reson Med. 2010;64:1592–8.CrossRefPubMedPubMedCentral
54.
Zurück zum Zitat Pedersen H, Kozerke S, Ringgaard S, Nehrke K, Kim WY. k-t PCA: temporally constrained k-t BLAST reconstruction using principal component analysis. Magn Reson Med. 2009;62:706–16.CrossRefPubMed Pedersen H, Kozerke S, Ringgaard S, Nehrke K, Kim WY. k-t PCA: temporally constrained k-t BLAST reconstruction using principal component analysis. Magn Reson Med. 2009;62:706–16.CrossRefPubMed
55.
Zurück zum Zitat Jogiya R, Makowski M, Phinikaridou A, Patel AS, Jansen C, Zarinabad N, Chiribiri A, Botnar R, Nagel E, Kozerke S, Plein S. Hyperemic stress myocardial perfusion cardiovascular magnetic resonance in mice at 3 Tesla: initial experience and validation against microspheres. J Cardiovasc Magn Reson. 2013;15:62.CrossRefPubMedPubMedCentral Jogiya R, Makowski M, Phinikaridou A, Patel AS, Jansen C, Zarinabad N, Chiribiri A, Botnar R, Nagel E, Kozerke S, Plein S. Hyperemic stress myocardial perfusion cardiovascular magnetic resonance in mice at 3 Tesla: initial experience and validation against microspheres. J Cardiovasc Magn Reson. 2013;15:62.CrossRefPubMedPubMedCentral
56.
Zurück zum Zitat Naresh NK, Chen X, Roy RJ, Antkowiak PF, Annex BH, Epstein FH. Accelerated dual-contrast first-pass perfusion MRI of the mouse heart: development and application to diet-induced obese mice. Magn Reson Med. 2015;73:1237–45.CrossRefPubMedPubMedCentral Naresh NK, Chen X, Roy RJ, Antkowiak PF, Annex BH, Epstein FH. Accelerated dual-contrast first-pass perfusion MRI of the mouse heart: development and application to diet-induced obese mice. Magn Reson Med. 2015;73:1237–45.CrossRefPubMedPubMedCentral
57.
Zurück zum Zitat Naresh NK, Chen X, Moran E, Tian Y, French BA, Epstein FH. Repeatability and variability of myocardial perfusion imaging techniques in mice: Comparison of arterial spin labeling and first-pass contrast-enhanced MRI: Repeatability and Variability of First-Pass MRI and ASL in Mice. Magn Reson Med 2015:n/a–n/a. doi:10.1002/mrm.25769. [Epub ahead of print] Naresh NK, Chen X, Moran E, Tian Y, French BA, Epstein FH. Repeatability and variability of myocardial perfusion imaging techniques in mice: Comparison of arterial spin labeling and first-pass contrast-enhanced MRI: Repeatability and Variability of First-Pass MRI and ASL in Mice. Magn Reson Med 2015:n/a–n/a. doi:10.​1002/​mrm.​25769. [Epub ahead of print]
58.
Zurück zum Zitat Waller C, Hiller KH, Kahler E, Hu K, Nahrendorf M, Voll S, Haase A, Ertl G, Bauer WR. Serial magnetic resonance imaging of microvascular remodeling in the infarcted rat heart. Circulation. 2001;103:1564–9.CrossRefPubMed Waller C, Hiller KH, Kahler E, Hu K, Nahrendorf M, Voll S, Haase A, Ertl G, Bauer WR. Serial magnetic resonance imaging of microvascular remodeling in the infarcted rat heart. Circulation. 2001;103:1564–9.CrossRefPubMed
59.
Zurück zum Zitat Hiller KH, Ruile P, Kraus G, Bauer WR, Waller C. Tissue ACE inhibition improves microcirculation in remote myocardium after coronary stenosis: MR imaging study in rats. Microvasc Res. 2010;80:484–90.CrossRefPubMed Hiller KH, Ruile P, Kraus G, Bauer WR, Waller C. Tissue ACE inhibition improves microcirculation in remote myocardium after coronary stenosis: MR imaging study in rats. Microvasc Res. 2010;80:484–90.CrossRefPubMed
60.
Zurück zum Zitat Vandsburger MH, French BA, Helm PA, Roy RJ, Kramer CM, Young AA, Epstein FH. Multi-parameter in vivo cardiac magnetic resonance imaging demonstrates normal perfusion reserve despite severely attenuated beta-adrenergic functional response in neuronal nitric oxide synthase knockout mice. Eur Heart J. 2007;28:2792–8.CrossRefPubMed Vandsburger MH, French BA, Helm PA, Roy RJ, Kramer CM, Young AA, Epstein FH. Multi-parameter in vivo cardiac magnetic resonance imaging demonstrates normal perfusion reserve despite severely attenuated beta-adrenergic functional response in neuronal nitric oxide synthase knockout mice. Eur Heart J. 2007;28:2792–8.CrossRefPubMed
61.
Zurück zum Zitat Caudron J, Mulder P, Nicol L, Richard V, Thuillez C, Dacher J-N. MR relaxometry and perfusion of the myocardium in spontaneously hypertensive rat: correlation with histopathology and effect of anti-hypertensive therapy. Eur Radiol. 2013;23:1871–81.CrossRefPubMed Caudron J, Mulder P, Nicol L, Richard V, Thuillez C, Dacher J-N. MR relaxometry and perfusion of the myocardium in spontaneously hypertensive rat: correlation with histopathology and effect of anti-hypertensive therapy. Eur Radiol. 2013;23:1871–81.CrossRefPubMed
62.
Zurück zum Zitat Zhang H, Qiao H, Frank RS, Huang B, Propert KJ, Margulies S, Ferrari VA, Epstein JA, Zhou R. Spin-labeling magnetic resonance imaging detects increased myocardial blood flow after endothelial cell transplantation in the infarcted heart. Circ Cardiovasc Imaging. 2012;5:210–7.CrossRefPubMedPubMedCentral Zhang H, Qiao H, Frank RS, Huang B, Propert KJ, Margulies S, Ferrari VA, Epstein JA, Zhou R. Spin-labeling magnetic resonance imaging detects increased myocardial blood flow after endothelial cell transplantation in the infarcted heart. Circ Cardiovasc Imaging. 2012;5:210–7.CrossRefPubMedPubMedCentral
63.
Zurück zum Zitat Besnier M, Galaup A, Nicol L, Henry J-P, Coquerel D, Gueret A, Mulder P, Brakenhielm E, Thuillez C, Germain S, Richard V, Ouvrard-Pascaud A. Enhanced angiogenesis and increased cardiac perfusion after myocardial infarction in protein tyrosine phosphatase 1B-deficient mice. FASEB J. 2014;28:3351–61.CrossRefPubMed Besnier M, Galaup A, Nicol L, Henry J-P, Coquerel D, Gueret A, Mulder P, Brakenhielm E, Thuillez C, Germain S, Richard V, Ouvrard-Pascaud A. Enhanced angiogenesis and increased cardiac perfusion after myocardial infarction in protein tyrosine phosphatase 1B-deficient mice. FASEB J. 2014;28:3351–61.CrossRefPubMed
64.
Zurück zum Zitat Merabet N, Bellien J, Glevarec E, Nicol L, Lucas D, Remy-Jouet I, Bounoure F, Dreano Y, Wecker D, Thuillez C, Mulder P. Soluble epoxide hydrolase inhibition improves myocardial perfusion and function in experimental heart failure. J Mol Cell Cardiol. 2012;52:660–6.CrossRefPubMed Merabet N, Bellien J, Glevarec E, Nicol L, Lucas D, Remy-Jouet I, Bounoure F, Dreano Y, Wecker D, Thuillez C, Mulder P. Soluble epoxide hydrolase inhibition improves myocardial perfusion and function in experimental heart failure. J Mol Cell Cardiol. 2012;52:660–6.CrossRefPubMed
65.
Zurück zum Zitat Desrois M, Kober F, Lan C, Dalmasso C, Cole M, Clarke K, Cozzone PJ, Bernard M. Effect of isoproterenol on myocardial perfusion, function, energy metabolism and nitric oxide pathway in the rat heart - a longitudinal MR study. NMR Biomed. 2014;27:529–38.CrossRefPubMed Desrois M, Kober F, Lan C, Dalmasso C, Cole M, Clarke K, Cozzone PJ, Bernard M. Effect of isoproterenol on myocardial perfusion, function, energy metabolism and nitric oxide pathway in the rat heart - a longitudinal MR study. NMR Biomed. 2014;27:529–38.CrossRefPubMed
66.
Zurück zum Zitat Abdesselam I, Pepino P, Troalen T, Macia M, Ancel P, Masi B, Fourny N, Gaborit B, Giannesini B, Kober F, Dutour A, Bernard M. Time course of cardiometabolic alterations in a high fat high sucrose diet mice model and improvement after GLP-1 analog treatment using multimodal cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2015;17. Abdesselam I, Pepino P, Troalen T, Macia M, Ancel P, Masi B, Fourny N, Gaborit B, Giannesini B, Kober F, Dutour A, Bernard M. Time course of cardiometabolic alterations in a high fat high sucrose diet mice model and improvement after GLP-1 analog treatment using multimodal cardiovascular magnetic resonance. J Cardiovasc Magn Reson. 2015;17.
67.
Zurück zum Zitat Poncelet BP, Koelling TM, Schmidt CJ, Kwong KK, Reese TG, Ledden P, Kantor HL, Brady TJ, Weisskoff RM. Measurement of human myocardial perfusion by double-gated flow alternating inversion recovery EPI. Magn Reson Med. 1999;41:510–9.CrossRefPubMed Poncelet BP, Koelling TM, Schmidt CJ, Kwong KK, Reese TG, Ledden P, Kantor HL, Brady TJ, Weisskoff RM. Measurement of human myocardial perfusion by double-gated flow alternating inversion recovery EPI. Magn Reson Med. 1999;41:510–9.CrossRefPubMed
68.
Zurück zum Zitat Wacker CM, Bock M, Hartlep AW, Beck G, van Kaick G, Ertl G, Bauer WR, Schad LR. Changes in myocardial oxygenation and perfusion under pharmacological stress with dipyridamole: assessment using T*2 and T1 measurements. Magn Reson Med. 1999;41:686–95.CrossRefPubMed Wacker CM, Bock M, Hartlep AW, Beck G, van Kaick G, Ertl G, Bauer WR, Schad LR. Changes in myocardial oxygenation and perfusion under pharmacological stress with dipyridamole: assessment using T*2 and T1 measurements. Magn Reson Med. 1999;41:686–95.CrossRefPubMed
69.
Zurück zum Zitat Wacker CM, Fidler F, Dueren C, Hirn S, Jakob PM, Ertl G, Haase A, Bauer WR. Quantitative assessment of myocardial perfusion with a spin-labeling technique: preliminary results in patients with coronary artery disease. J Magn Reson Imaging. 2003;18:555–60.CrossRefPubMed Wacker CM, Fidler F, Dueren C, Hirn S, Jakob PM, Ertl G, Haase A, Bauer WR. Quantitative assessment of myocardial perfusion with a spin-labeling technique: preliminary results in patients with coronary artery disease. J Magn Reson Imaging. 2003;18:555–60.CrossRefPubMed
70.
Zurück zum Zitat Chefd’Hotel C, Hermosillo G, Faugeras O. Flows of Diffeomorphisms for Multimodal Image Registration. Proc IEEE Int Symp Biomed Imaging ISBI’2002 Wash DC USA 2002 2004:753–756. Chefd’Hotel C, Hermosillo G, Faugeras O. Flows of Diffeomorphisms for Multimodal Image Registration. Proc IEEE Int Symp Biomed Imaging ISBI’2002 Wash DC USA 2002 2004:753–756.
71.
Zurück zum Zitat Chareonthaitawee P, Kaufmann PA, Rimoldi O, Camici PG. Heterogeneity of resting and hyperemic myocardial blood flow in healthy humans. Cardiovasc Res. 2001;50:151–61.CrossRefPubMed Chareonthaitawee P, Kaufmann PA, Rimoldi O, Camici PG. Heterogeneity of resting and hyperemic myocardial blood flow in healthy humans. Cardiovasc Res. 2001;50:151–61.CrossRefPubMed
72.
Zurück zum Zitat Schepis T, Gaemperli O, Treyer V, Valenta I, Burger C, Koepfli P, Namdar M, Adachi I, Alkadhi H, Kaufmann PA. Absolute quantification of myocardial blood flow with 13 N-ammonia and 3-dimensional PET. J Nucl Med. 2007;48:1783–9.CrossRefPubMed Schepis T, Gaemperli O, Treyer V, Valenta I, Burger C, Koepfli P, Namdar M, Adachi I, Alkadhi H, Kaufmann PA. Absolute quantification of myocardial blood flow with 13 N-ammonia and 3-dimensional PET. J Nucl Med. 2007;48:1783–9.CrossRefPubMed
73.
Zurück zum Zitat Hsu L-Y, Rhoads KL, Holly JE, Kellman P, Aletras AH, Arai AE. Quantitative myocardial perfusion analysis with a dual-bolus contrast-enhanced first-pass MRI technique in humans. J Magn Reson Imaging JMRI. 2006;23:315–22.CrossRefPubMed Hsu L-Y, Rhoads KL, Holly JE, Kellman P, Aletras AH, Arai AE. Quantitative myocardial perfusion analysis with a dual-bolus contrast-enhanced first-pass MRI technique in humans. J Magn Reson Imaging JMRI. 2006;23:315–22.CrossRefPubMed
74.
Zurück zum Zitat Miyazaki M, Zhou X, Hoshino T, Yokoyama K, Ishimura R, Nitatori T. Non-contrast myocardial perfusion using a novel 4D magnetic resonance arterial spin labeling technique: initial experience. Microvasc Res. 2015;98:94–101.CrossRefPubMed Miyazaki M, Zhou X, Hoshino T, Yokoyama K, Ishimura R, Nitatori T. Non-contrast myocardial perfusion using a novel 4D magnetic resonance arterial spin labeling technique: initial experience. Microvasc Res. 2015;98:94–101.CrossRefPubMed
75.
Zurück zum Zitat Capron T, Troalen T, Robert B, Jacquier A, Bernard M, Kober F. Myocardial perfusion assessment in humans using steady-pulsed arterial spin labeling: Human MBF Using Steady-Pulsed Arterial Spin Labeling. Magn Reson Med. 2015;74:990–8.CrossRefPubMed Capron T, Troalen T, Robert B, Jacquier A, Bernard M, Kober F. Myocardial perfusion assessment in humans using steady-pulsed arterial spin labeling: Human MBF Using Steady-Pulsed Arterial Spin Labeling. Magn Reson Med. 2015;74:990–8.CrossRefPubMed
76.
Zurück zum Zitat Northrup BE, McCommis KS, Zhang H, Ray S, Woodard PK, Gropler RJ, Zheng J. Resting myocardial perfusion quantification with CMR arterial spin labeling at 1.5 T and 3.0 T. J Cardiovasc Magn Reson. 2008;10:53.CrossRefPubMedPubMedCentral Northrup BE, McCommis KS, Zhang H, Ray S, Woodard PK, Gropler RJ, Zheng J. Resting myocardial perfusion quantification with CMR arterial spin labeling at 1.5 T and 3.0 T. J Cardiovasc Magn Reson. 2008;10:53.CrossRefPubMedPubMedCentral
77.
Zurück zum Zitat Zhou J, van Zijl PC. Effect of transit times on quantification of cerebral blood flow by the FAIR T(1)-difference approach. Magn Reson Med. 1999;42:890–4.CrossRefPubMed Zhou J, van Zijl PC. Effect of transit times on quantification of cerebral blood flow by the FAIR T(1)-difference approach. Magn Reson Med. 1999;42:890–4.CrossRefPubMed
78.
Zurück zum Zitat Javed A, Jao TR, Nayak KS. Motion correction facilitates the automation of cardiac ASL perfusion imaging. J Cardiovasc Magn Reson. 2015;17 Suppl 1:51.CrossRef Javed A, Jao TR, Nayak KS. Motion correction facilitates the automation of cardiac ASL perfusion imaging. J Cardiovasc Magn Reson. 2015;17 Suppl 1:51.CrossRef
80.
Zurück zum Zitat Kellman P, Chefd’hotel C, Lorenz CH, Mancini C, Arai AE, McVeigh ER. Fully automatic, retrospective enhancement of real-time acquired cardiac cine MR images using image-based navigators and respiratory motion-corrected averaging. Magn Reson Med. 2008;59:771–8.CrossRefPubMed Kellman P, Chefd’hotel C, Lorenz CH, Mancini C, Arai AE, McVeigh ER. Fully automatic, retrospective enhancement of real-time acquired cardiac cine MR images using image-based navigators and respiratory motion-corrected averaging. Magn Reson Med. 2008;59:771–8.CrossRefPubMed
81.
Zurück zum Zitat Kellman P, Chefd’hotel C, Lorenz CH, Mancini C, Arai AE, McVeigh ER. High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting. Magn Reson Med. 2009;62:1557–64.CrossRefPubMedPubMedCentral Kellman P, Chefd’hotel C, Lorenz CH, Mancini C, Arai AE, McVeigh ER. High spatial and temporal resolution cardiac cine MRI from retrospective reconstruction of data acquired in real time using motion correction and resorting. Magn Reson Med. 2009;62:1557–64.CrossRefPubMedPubMedCentral
83.
Zurück zum Zitat Zhang H, Shea SM, Park V, Li D, Woodard PK, Gropler RJ, Zheng J. Accurate myocardial T1 measurements: toward quantification of myocardial blood flow with arterial spin labeling. Magn Reson Med. 2005;53:1135–42.CrossRefPubMed Zhang H, Shea SM, Park V, Li D, Woodard PK, Gropler RJ, Zheng J. Accurate myocardial T1 measurements: toward quantification of myocardial blood flow with arterial spin labeling. Magn Reson Med. 2005;53:1135–42.CrossRefPubMed
84.
Zurück zum Zitat Lowe DK, Rothbaum DA, McHenry PL, Corya BC, Knoebel SB. Myocardial blood flow response to isometric (handgrip) and treadmill exercise in coronary artery disease. Circulation. 1975;51:126–31.CrossRefPubMed Lowe DK, Rothbaum DA, McHenry PL, Corya BC, Knoebel SB. Myocardial blood flow response to isometric (handgrip) and treadmill exercise in coronary artery disease. Circulation. 1975;51:126–31.CrossRefPubMed
85.
Zurück zum Zitat Chan SY, Brunken RC, Czernin J, Porenta G, Kuhle W, Krivokapich J, Phelps ME, Schelbert HR. Comparison of maximal myocardial blood flow during adenosine infusion with that of intravenous dipyridamole in normal men. J Am Coll Cardiol. 1992;20:979–85.CrossRefPubMed Chan SY, Brunken RC, Czernin J, Porenta G, Kuhle W, Krivokapich J, Phelps ME, Schelbert HR. Comparison of maximal myocardial blood flow during adenosine infusion with that of intravenous dipyridamole in normal men. J Am Coll Cardiol. 1992;20:979–85.CrossRefPubMed
86.
Zurück zum Zitat Zun Z, Varadarajan P, Pai RG, Wong EC, Nayak KS. Arterial Spin Labeled CMR Detects Clinically Relevant Increase in Myocardial Blood Flow With Vasodilation. JACC Cardiovasc Imaging. 2011;4:1253–61.CrossRefPubMed Zun Z, Varadarajan P, Pai RG, Wong EC, Nayak KS. Arterial Spin Labeled CMR Detects Clinically Relevant Increase in Myocardial Blood Flow With Vasodilation. JACC Cardiovasc Imaging. 2011;4:1253–61.CrossRefPubMed
87.
88.
Zurück zum Zitat Lau AZ, Tunnicliffe EM, Frost R, Koopmans PJ, Tyler DJ, Robson MD. Accelerated human cardiac diffusion tensor imaging using simultaneous multislice imaging. Magn Reson Med. 2015;73:995–1004.CrossRefPubMed Lau AZ, Tunnicliffe EM, Frost R, Koopmans PJ, Tyler DJ, Robson MD. Accelerated human cardiac diffusion tensor imaging using simultaneous multislice imaging. Magn Reson Med. 2015;73:995–1004.CrossRefPubMed
89.
Zurück zum Zitat Stäb D, Ritter CO, Breuer FA, Weng AM, Hahn D, Köstler H. CAIPIRINHA accelerated SSFP imaging. Magn Reson Med. 2011;65:157–64.CrossRefPubMed Stäb D, Ritter CO, Breuer FA, Weng AM, Hahn D, Köstler H. CAIPIRINHA accelerated SSFP imaging. Magn Reson Med. 2011;65:157–64.CrossRefPubMed
90.
Zurück zum Zitat Larson AC, Simonetti OP, Li D. Coronary MRA with 3D undersampled projection reconstruction TrueFISP. Magn Reson Med. 2002;48:594–601.CrossRefPubMed Larson AC, Simonetti OP, Li D. Coronary MRA with 3D undersampled projection reconstruction TrueFISP. Magn Reson Med. 2002;48:594–601.CrossRefPubMed
91.
Zurück zum Zitat Peters DC, Ennis DB, Rohatgi P, Syed MA, McVeigh ER, Arai AE. 3D breath-held cardiac function with projection reconstruction in steady state free precession validated using 2D cine MRI. J Magn Reson Imaging. 2004;20:411–6.CrossRefPubMedPubMedCentral Peters DC, Ennis DB, Rohatgi P, Syed MA, McVeigh ER, Arai AE. 3D breath-held cardiac function with projection reconstruction in steady state free precession validated using 2D cine MRI. J Magn Reson Imaging. 2004;20:411–6.CrossRefPubMedPubMedCentral
92.
Zurück zum Zitat Stehning C, Börnert P, Nehrke K, Eggers H, Stuber M. Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction. Magn Reson Med. 2005;54:476–80.CrossRefPubMed Stehning C, Börnert P, Nehrke K, Eggers H, Stuber M. Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction. Magn Reson Med. 2005;54:476–80.CrossRefPubMed
93.
Zurück zum Zitat Zun Z, Wong EC, Nayak KS. Myocardial ASL perfusion imaging using pulsed 2D tagging of the proximal aorta. Proc Intl Soc Mag Reson Med. 2009;17:1737. Zun Z, Wong EC, Nayak KS. Myocardial ASL perfusion imaging using pulsed 2D tagging of the proximal aorta. Proc Intl Soc Mag Reson Med. 2009;17:1737.
94.
Zurück zum Zitat Odille F, Vuissoz P-A, Marie P-Y, Felblinger J. Generalized Reconstruction by Inversion of Coupled Systems (GRICS) applied to free-breathing MRI. Magn Reson Med. 2008;60:146–57.CrossRefPubMed Odille F, Vuissoz P-A, Marie P-Y, Felblinger J. Generalized Reconstruction by Inversion of Coupled Systems (GRICS) applied to free-breathing MRI. Magn Reson Med. 2008;60:146–57.CrossRefPubMed
95.
Zurück zum Zitat Liu J, Spincemaille P, Codella NCF, Nguyen TD, Prince MR, Wang Y. Respiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition. Magn Reson Med. 2010;63:1230–7.CrossRefPubMedPubMedCentral Liu J, Spincemaille P, Codella NCF, Nguyen TD, Prince MR, Wang Y. Respiratory and cardiac self-gated free-breathing cardiac CINE imaging with multiecho 3D hybrid radial SSFP acquisition. Magn Reson Med. 2010;63:1230–7.CrossRefPubMedPubMedCentral
96.
Zurück zum Zitat Han F, Zhou Z, Rapacchi S, Finn PJ, Hu P. Segmented golden ratio radial reordering for dynamic cardiac MRI with variable temporal resolution. J Cardiovasc Magn Reson. 2015;17 Suppl 1:Q124.CrossRefPubMedCentral Han F, Zhou Z, Rapacchi S, Finn PJ, Hu P. Segmented golden ratio radial reordering for dynamic cardiac MRI with variable temporal resolution. J Cardiovasc Magn Reson. 2015;17 Suppl 1:Q124.CrossRefPubMedCentral
97.
Zurück zum Zitat Wong EC, Cronin M, Wu W-C, Inglis B, Frank LR, Liu TT. Velocity-selective arterial spin labeling. Magn Reson Med. 2006;55:1334–41.CrossRefPubMed Wong EC, Cronin M, Wu W-C, Inglis B, Frank LR, Liu TT. Velocity-selective arterial spin labeling. Magn Reson Med. 2006;55:1334–41.CrossRefPubMed
98.
Zurück zum Zitat Qiu D, Straka M, Zun Z, Bammer R, Moseley ME, Zaharchuk G. CBF measurements using multidelay pseudocontinuous and velocity-selective arterial spin labeling in patients with long arterial transit delays: Comparison with xenon CT CBF. J Magn Reson Imaging. 2012;36:110–9.CrossRefPubMedPubMedCentral Qiu D, Straka M, Zun Z, Bammer R, Moseley ME, Zaharchuk G. CBF measurements using multidelay pseudocontinuous and velocity-selective arterial spin labeling in patients with long arterial transit delays: Comparison with xenon CT CBF. J Magn Reson Imaging. 2012;36:110–9.CrossRefPubMedPubMedCentral
100.
Zurück zum Zitat Madsen PL, Holm S, Herning M, Lassen NA. Average blood flow and oxygen uptake in the human brain during resting wakefulness: a critical appraisal of the Kety-Schmidt technique. J Cereb Blood Flow Metab. 1993;13:646–55. Madsen PL, Holm S, Herning M, Lassen NA. Average blood flow and oxygen uptake in the human brain during resting wakefulness: a critical appraisal of the Kety-Schmidt technique. J Cereb Blood Flow Metab. 1993;13:646–55.
101.
Zurück zum Zitat Daley PJ, Sagar KB, Wann LS. Doppler echocardiographic measurement of flow velocity in the ascending aorta during supine and upright exercise. Br Heart J. 1985;54:562–7.CrossRefPubMedPubMedCentral Daley PJ, Sagar KB, Wann LS. Doppler echocardiographic measurement of flow velocity in the ascending aorta during supine and upright exercise. Br Heart J. 1985;54:562–7.CrossRefPubMedPubMedCentral
102.
Zurück zum Zitat Naruse M, Inagami T. Markedly elevated specific renin levels in the adrenal in genetically hypertensive rats. Proc Natl Acad Sci. 1982;79:3295–9.CrossRefPubMedPubMedCentral Naruse M, Inagami T. Markedly elevated specific renin levels in the adrenal in genetically hypertensive rats. Proc Natl Acad Sci. 1982;79:3295–9.CrossRefPubMedPubMedCentral
103.
Zurück zum Zitat Winter P, Kampf T, Helluy X, Gutjahr FT, Meyer CB, Rommel E, Bauer WR, Jakob PM, Herold V. Fast retrospectively triggered local pulse-wave velocity measurements in mice with CMR-microscopy using a radial trajectory. J Cardiovasc Magn Reson. 2013;15:88.CrossRefPubMedPubMedCentral Winter P, Kampf T, Helluy X, Gutjahr FT, Meyer CB, Rommel E, Bauer WR, Jakob PM, Herold V. Fast retrospectively triggered local pulse-wave velocity measurements in mice with CMR-microscopy using a radial trajectory. J Cardiovasc Magn Reson. 2013;15:88.CrossRefPubMedPubMedCentral
104.
Zurück zum Zitat Hiller KH, Waller C, Voll S, Haase A, Ertl G, Bauer WR. Combined high-speed NMR imaging of perfusion and microscopic coronary conductance vessels in the isolated rat heart. Microvasc Res. 2001;62:327–34.CrossRefPubMed Hiller KH, Waller C, Voll S, Haase A, Ertl G, Bauer WR. Combined high-speed NMR imaging of perfusion and microscopic coronary conductance vessels in the isolated rat heart. Microvasc Res. 2001;62:327–34.CrossRefPubMed
Metadaten
Titel
Myocardial arterial spin labeling
verfasst von
Frank Kober
Terrence Jao
Thomas Troalen
Krishna S. Nayak
Publikationsdatum
01.12.2016
Verlag
BioMed Central
Erschienen in
Journal of Cardiovascular Magnetic Resonance / Ausgabe 1/2016
Elektronische ISSN: 1532-429X
DOI
https://doi.org/10.1186/s12968-016-0235-4

Weitere Artikel der Ausgabe 1/2016

Journal of Cardiovascular Magnetic Resonance 1/2016 Zur Ausgabe

Update Radiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.