Skip to main content
Erschienen in: International Orthopaedics 4/2009

01.08.2009 | Original Paper

Nail over nail technique for distal locking of femoral intramedullary nails

verfasst von: Rajesh Rohilla, Roop Singh, Narender Magu, Ashish Devgun, Ramchander Siwach, Ashish Gulia

Erschienen in: International Orthopaedics | Ausgabe 4/2009

Einloggen, um Zugang zu erhalten

Abstract

The free hand technique remains the most popular method for distal locking; however, radiation exposure is a major concern. In an endeavour to overcome this concern, distal locking with the nail over nail technique is evaluated. Seventy patients with femoral diaphyseal fractures treated by intramedullary nailing were divided in two groups for distal locking: either using the free hand technique (group I) or with the nail over nail technique (group II). The average number of images taken to achieve nail insertion without locking, for distal locking, and for the complete procedure in group I was 25.8, 24.2, and 50.08, respectively, compared with 24.8, 4.1, and 28.9, respectively, in group II (statistically extremely significant decrease in radiation). The nail over nail technique appears to be a reliable solution for decreasing radiation exposure during closed femoral intramedullary nailing. However, over-reaming of 1.5 mm is the key to the success of the technique.
Literatur
1.
Zurück zum Zitat Aiyer S, Jagiasi J, Argekar H, Sharan S, Dasgupta B (2006) Closed antegrade interlocked nailing of femoral shaft fractures operated up to 2 weeks postinjury in the absence of a fracture table or c-arm. J Trauma 61:457–460PubMedCrossRef Aiyer S, Jagiasi J, Argekar H, Sharan S, Dasgupta B (2006) Closed antegrade interlocked nailing of femoral shaft fractures operated up to 2 weeks postinjury in the absence of a fracture table or c-arm. J Trauma 61:457–460PubMedCrossRef
2.
Zurück zum Zitat Bong MR, Kummer FJ, Koval KJ, Eqol KA (2007) Intramedullary nailing of the lower extremity: biomechanics and biology. J Am Acad Orthop Surg 15(2):97–106PubMed Bong MR, Kummer FJ, Koval KJ, Eqol KA (2007) Intramedullary nailing of the lower extremity: biomechanics and biology. J Am Acad Orthop Surg 15(2):97–106PubMed
3.
Zurück zum Zitat Goodall JD (1991) An image intensifier laser guidance system for the distal locking of an intramedullary nail. Injury 22:339PubMedCrossRef Goodall JD (1991) An image intensifier laser guidance system for the distal locking of an intramedullary nail. Injury 22:339PubMedCrossRef
4.
Zurück zum Zitat Hajek PD, Bicknell HR Jr, Bronson WE, Albright JA, Saha S (1993) The use of one compared with two distal screws in the treatment of femoral shaft fractures with interlocking intramedullary nailing. A clinical and biomechanical analysis. J Bone Joint Surg 75A:519–525 Hajek PD, Bicknell HR Jr, Bronson WE, Albright JA, Saha S (1993) The use of one compared with two distal screws in the treatment of femoral shaft fractures with interlocking intramedullary nailing. A clinical and biomechanical analysis. J Bone Joint Surg 75A:519–525
5.
Zurück zum Zitat Kanellopoulos AD, Yiannakopoulos CK, Vossinakis I, Badras LS (2003) Distal locking of femoral nails under direct vision through a cortical window. J Orthop Trauma 17(8):574–577PubMedCrossRef Kanellopoulos AD, Yiannakopoulos CK, Vossinakis I, Badras LS (2003) Distal locking of femoral nails under direct vision through a cortical window. J Orthop Trauma 17(8):574–577PubMedCrossRef
6.
Zurück zum Zitat Krettek C, Konemann B, Miclau T, Kolbli R, Machreich T, Kromm A, Tscherne H (1999) A mechanical distal aiming device for distal locking in femoral nails. Clin Orthop 364:267–275PubMedCrossRef Krettek C, Konemann B, Miclau T, Kolbli R, Machreich T, Kromm A, Tscherne H (1999) A mechanical distal aiming device for distal locking in femoral nails. Clin Orthop 364:267–275PubMedCrossRef
7.
Zurück zum Zitat Levin PE, Schoen RW, Browner BD (1987) Radiation exposure to the surgeon during closed interlocking intramedullary nailing. J Bone Joint Surg 69A:761–766 Levin PE, Schoen RW, Browner BD (1987) Radiation exposure to the surgeon during closed interlocking intramedullary nailing. J Bone Joint Surg 69A:761–766
8.
Zurück zum Zitat Mehlman CT, DiPasquale TG (1997) Radiation exposure to the orthopaedic surgical team during fluoroscopy: "How far away is far enough?" J Orthop Trauma 11:392–398PubMedCrossRef Mehlman CT, DiPasquale TG (1997) Radiation exposure to the orthopaedic surgical team during fluoroscopy: "How far away is far enough?" J Orthop Trauma 11:392–398PubMedCrossRef
9.
Zurück zum Zitat Muller LP, Suffner J, Wenda K, Mohr W, Rommens PM (1998) Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing. Injury 29:461–468PubMedCrossRef Muller LP, Suffner J, Wenda K, Mohr W, Rommens PM (1998) Radiation exposure to the hands and the thyroid of the surgeon during intramedullary nailing. Injury 29:461–468PubMedCrossRef
10.
Zurück zum Zitat Owen TD, Coorsh J (1993) Insertion of the distal locking screws in femoral nailing: a simplified technique. Injury 24:101–103PubMedCrossRef Owen TD, Coorsh J (1993) Insertion of the distal locking screws in femoral nailing: a simplified technique. Injury 24:101–103PubMedCrossRef
11.
Zurück zum Zitat Pardiwala D, Prabhu V, Dudhniwala G, Katre R (2001) The AO distal locking aiming device: an evaluation of efficacy and learning curve. Injury 32:713–718PubMedCrossRef Pardiwala D, Prabhu V, Dudhniwala G, Katre R (2001) The AO distal locking aiming device: an evaluation of efficacy and learning curve. Injury 32:713–718PubMedCrossRef
12.
Zurück zum Zitat Rao JP, Allegra MP, Benevenia J, Dauhajre TA (1989) Distal screw targeting of interlocking nails. Clin Orthop 238:245–248PubMed Rao JP, Allegra MP, Benevenia J, Dauhajre TA (1989) Distal screw targeting of interlocking nails. Clin Orthop 238:245–248PubMed
13.
Zurück zum Zitat Steriopoulos KA, Kontakis GM, Kantonis PG, Galanakis IA, Dretakis EK (1996) Placement of the distal locking screws of the femoral intramedullary nail without radiation. Arch Orthop Trauma Surg 115:43–44PubMedCrossRef Steriopoulos KA, Kontakis GM, Kantonis PG, Galanakis IA, Dretakis EK (1996) Placement of the distal locking screws of the femoral intramedullary nail without radiation. Arch Orthop Trauma Surg 115:43–44PubMedCrossRef
14.
Zurück zum Zitat Suhm N, Messmer P, Zuna I, Jacob LA, Reqazzoni P (2004) Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants: A prospective, controlled clinical study. Injury 35:567–574PubMedCrossRef Suhm N, Messmer P, Zuna I, Jacob LA, Reqazzoni P (2004) Fluoroscopic guidance versus surgical navigation for distal locking of intramedullary implants: A prospective, controlled clinical study. Injury 35:567–574PubMedCrossRef
15.
Zurück zum Zitat Tanna DD (1994) Interlocking tibial nailing without an image intensifier. J Bone Joint Surg 76B:670 Tanna DD (1994) Interlocking tibial nailing without an image intensifier. J Bone Joint Surg 76B:670
16.
Zurück zum Zitat Tyropoulos S, Garnavos C (2001) A new distal targeting device for closed interlocking nailing. Injury 32:732–735PubMedCrossRef Tyropoulos S, Garnavos C (2001) A new distal targeting device for closed interlocking nailing. Injury 32:732–735PubMedCrossRef
17.
Zurück zum Zitat Whatling GM, Nokes LDM (2006) Literature review of current techniques for the insertion of distal screws into intramedullary locking nails. Injury 37:109–119PubMedCrossRef Whatling GM, Nokes LDM (2006) Literature review of current techniques for the insertion of distal screws into intramedullary locking nails. Injury 37:109–119PubMedCrossRef
18.
Zurück zum Zitat Whittle AP, Wood GW (2003) Fractures of lower extremity. In: Canale ST (ed) Campbell’s operative orthopaedics. Mosby, St. Louis, pp 2841–2845 Whittle AP, Wood GW (2003) Fractures of lower extremity. In: Canale ST (ed) Campbell’s operative orthopaedics. Mosby, St. Louis, pp 2841–2845
19.
Zurück zum Zitat Wu CC, Shih CH (1992) Biomechanical analysis of the mechanism of interlocking nail failure. Arch Orthop Trauma Surg 111(5):268–272PubMedCrossRef Wu CC, Shih CH (1992) Biomechanical analysis of the mechanism of interlocking nail failure. Arch Orthop Trauma Surg 111(5):268–272PubMedCrossRef
20.
Zurück zum Zitat Yiannakopoulos CK, Kanellopoulos AD, Apostolou C, Antonoqiannakis E, Korres DS (2005) Distal intramedullary nail interlocking: the flag and grid technique. J Orthop Trauma 19(6):407–411CrossRef Yiannakopoulos CK, Kanellopoulos AD, Apostolou C, Antonoqiannakis E, Korres DS (2005) Distal intramedullary nail interlocking: the flag and grid technique. J Orthop Trauma 19(6):407–411CrossRef
21.
Zurück zum Zitat Zheng G, Zhang X, Haschtmann D, Gedet P, Lanqlotz F, Nolte LP (2007) Accurate and reliable pose recovery of distal locking holes in computer-assisted intramedullary nailing of femoral shaft fractures: a preliminary study. Comput Aided Surg 12:138–151PubMedCrossRef Zheng G, Zhang X, Haschtmann D, Gedet P, Lanqlotz F, Nolte LP (2007) Accurate and reliable pose recovery of distal locking holes in computer-assisted intramedullary nailing of femoral shaft fractures: a preliminary study. Comput Aided Surg 12:138–151PubMedCrossRef
Metadaten
Titel
Nail over nail technique for distal locking of femoral intramedullary nails
verfasst von
Rajesh Rohilla
Roop Singh
Narender Magu
Ashish Devgun
Ramchander Siwach
Ashish Gulia
Publikationsdatum
01.08.2009
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 4/2009
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-008-0579-y

Weitere Artikel der Ausgabe 4/2009

International Orthopaedics 4/2009 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.