Skip to main content
Erschienen in: International Orthopaedics 1/2009

01.02.2009 | Original Paper

Navigated non-image-based positioning of the acetabulum during total hip replacement

verfasst von: Jean-Yves Jenny, Cyril Boeri, Jean-Claude Dosch, Marius Uscatu, Eugen Ciobanu

Erschienen in: International Orthopaedics | Ausgabe 1/2009

Einloggen, um Zugang zu erhalten

Abstract

We tested the hypothesis that the non-image-based navigation system used in our department was able to measure accurately the 3D positioning of the acetabular cup of a total hip replacement (THR) and to increase the accuracy of its implantation during THR. We studied 50 consecutive navigated implantations of a THR and compared the intra-operative measurement of the cup by the navigation system to the post-operative measurement by computed tomography (CT) scan. The mean difference between the navigated and CT scan measurements for cup inclination was 2°. The mean difference between the navigated and CT-scan measurements for cup flexion was 4°. These differences were significant but considered to be clinically irrelevant in most cases. A total of 73% of the cases were within the safe zone defined prior to the study. The non-image-based system used allows a precise orientation of the cup during THR.
Literatur
1.
Zurück zum Zitat Biedermann R, Tonin A, Krismer M, Rachbauer F, Eibl G, Stöckl B (2005) Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component. J Bone Joint Surg Br 87:762–769PubMedCrossRef Biedermann R, Tonin A, Krismer M, Rachbauer F, Eibl G, Stöckl B (2005) Reducing the risk of dislocation after total hip arthroplasty: the effect of orientation of the acetabular component. J Bone Joint Surg Br 87:762–769PubMedCrossRef
2.
Zurück zum Zitat Blendea S, Troccaz J, Merloz P (2007) Accuracy measurements of acetabular cup positioning using CT less navigation. Rev Chir Orthop Reparatrice Appar Mot 93:157–164PubMed Blendea S, Troccaz J, Merloz P (2007) Accuracy measurements of acetabular cup positioning using CT less navigation. Rev Chir Orthop Reparatrice Appar Mot 93:157–164PubMed
3.
Zurück zum Zitat Delp SL, Stulberg SD, Davies BL, Picard F, Leitner F (1998) Computer assisted knee replacement. Clin Orthop Relat Res 354:49–56PubMedCrossRef Delp SL, Stulberg SD, Davies BL, Picard F, Leitner F (1998) Computer assisted knee replacement. Clin Orthop Relat Res 354:49–56PubMedCrossRef
4.
Zurück zum Zitat Digioia AM 3rd, Jaramaz B, Plakseychuk AY, Moody JE Jr, Nikou C, Labarca RS, Levison TJ, Picard F (2002) Comparison of a mechanical acetabular alignment guide with computer placement of the socket. J Arthroplasty 17:359–364PubMedCrossRef Digioia AM 3rd, Jaramaz B, Plakseychuk AY, Moody JE Jr, Nikou C, Labarca RS, Levison TJ, Picard F (2002) Comparison of a mechanical acetabular alignment guide with computer placement of the socket. J Arthroplasty 17:359–364PubMedCrossRef
5.
Zurück zum Zitat Grützner PA, Zheng G, Langlotz U, von Recum J, Nolte LP, Wentzensen A, Widmer KH, Wendl K (2004) C-arm based navigation in total hip arthroplasty—background and clinical experience. Injury 35(Suppl 1):S-A90–S-A95 Grützner PA, Zheng G, Langlotz U, von Recum J, Nolte LP, Wentzensen A, Widmer KH, Wendl K (2004) C-arm based navigation in total hip arthroplasty—background and clinical experience. Injury 35(Suppl 1):S-A90–S-A95
6.
Zurück zum Zitat Haaker RGA, Tiedjen K, Ottersbach A, Rubenthaler F, Stockheim M, Stiehl JB (2007) Comparison of conventional versus computer-navigated acetabular component insertion. J Arthoplasty 22:151–159CrossRef Haaker RGA, Tiedjen K, Ottersbach A, Rubenthaler F, Stockheim M, Stiehl JB (2007) Comparison of conventional versus computer-navigated acetabular component insertion. J Arthoplasty 22:151–159CrossRef
7.
Zurück zum Zitat Hirakawa K, Mitsugi N, Koshino T, Saito T, Hirasawa Y, Kubo T (2001) Effect of acetabular cup position and orientation in cemented total hip arthroplasty. Clin Orthop Relat Res 388:135–142PubMedCrossRef Hirakawa K, Mitsugi N, Koshino T, Saito T, Hirasawa Y, Kubo T (2001) Effect of acetabular cup position and orientation in cemented total hip arthroplasty. Clin Orthop Relat Res 388:135–142PubMedCrossRef
8.
Zurück zum Zitat Honl M, Schwieger K, Salineros M, Jacobs J, Morlock M, Wimmer M (2006) Orientation of the acetabular component. A comparison of five navigation systems with conventional surgical technique. J Bone Joint Surg Br 88:1401–1405PubMedCrossRef Honl M, Schwieger K, Salineros M, Jacobs J, Morlock M, Wimmer M (2006) Orientation of the acetabular component. A comparison of five navigation systems with conventional surgical technique. J Bone Joint Surg Br 88:1401–1405PubMedCrossRef
9.
Zurück zum Zitat Jenny JY, Boeri C (2003) Unicompartmental knee prosthesis implantation with a non-image-based navigation system: rationale, technique, case-control comparative study with a conventional instrumented implantation. Knee Surg Sports Traumatol Arthrosc 11:40–45PubMed Jenny JY, Boeri C (2003) Unicompartmental knee prosthesis implantation with a non-image-based navigation system: rationale, technique, case-control comparative study with a conventional instrumented implantation. Knee Surg Sports Traumatol Arthrosc 11:40–45PubMed
10.
Zurück zum Zitat Kalteis T, Handel M, Herold T, Perlick L, Baethis H, Grifka J (2005) Greater accuracy in positioning of the acetabular cup by using an image-free navigation system. Int Orthop 29:272–276PubMedCrossRef Kalteis T, Handel M, Herold T, Perlick L, Baethis H, Grifka J (2005) Greater accuracy in positioning of the acetabular cup by using an image-free navigation system. Int Orthop 29:272–276PubMedCrossRef
11.
Zurück zum Zitat Kalteis T, Handel M, Herold T, Perlick L, Paetzel C, Grifka J (2006) Position of the acetabular cup—accuracy of radiographic calculation compared to CT-based measurement. Eur J Radiol 58:294–300PubMedCrossRef Kalteis T, Handel M, Herold T, Perlick L, Paetzel C, Grifka J (2006) Position of the acetabular cup—accuracy of radiographic calculation compared to CT-based measurement. Eur J Radiol 58:294–300PubMedCrossRef
12.
Zurück zum Zitat Kalteis T, Handel M, Bäthis H, Perlick L, Tingart M, Grifka J (2006) Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation. J Bone Joint Surg Br 88:163–167PubMedCrossRef Kalteis T, Handel M, Bäthis H, Perlick L, Tingart M, Grifka J (2006) Imageless navigation for insertion of the acetabular component in total hip arthroplasty: is it as accurate as CT-based navigation. J Bone Joint Surg Br 88:163–167PubMedCrossRef
13.
Zurück zum Zitat Kiefer H, Othman A (2005) OrthoPilot total hip arthroplasty workflow and surgery. Orthopedics 28(Suppl 10):s1221–s1226PubMed Kiefer H, Othman A (2005) OrthoPilot total hip arthroplasty workflow and surgery. Orthopedics 28(Suppl 10):s1221–s1226PubMed
14.
Zurück zum Zitat Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60:217–220PubMed Lewinnek GE, Lewis JL, Tarr R, Compere CL, Zimmerman JR (1978) Dislocations after total hip-replacement arthroplasties. J Bone Joint Surg Am 60:217–220PubMed
15.
Zurück zum Zitat Marx A, von Knoch M, Pförtner J, Wiese M, Saxler G (2006) Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography. Arch Orthop Trauma Surg 126:487–492PubMedCrossRef Marx A, von Knoch M, Pförtner J, Wiese M, Saxler G (2006) Misinterpretation of cup anteversion in total hip arthroplasty using planar radiography. Arch Orthop Trauma Surg 126:487–492PubMedCrossRef
16.
Zurück zum Zitat Mayr E, Kessler O, Prassl A, Rachbauer F, Krismer M, Nogler M (2005) The frontal pelvic plane provides a valid reference system for implantation of the acetabular cup: spatial orientation of the pelvis in different positions. Acta Orthop 76:848–853PubMedCrossRef Mayr E, Kessler O, Prassl A, Rachbauer F, Krismer M, Nogler M (2005) The frontal pelvic plane provides a valid reference system for implantation of the acetabular cup: spatial orientation of the pelvis in different positions. Acta Orthop 76:848–853PubMedCrossRef
17.
Zurück zum Zitat Parratte S, Argenson JNA (2007) Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty. A prospective, randomized, controlled study. J Bone Joint Surg Am 89:494–499PubMedCrossRef Parratte S, Argenson JNA (2007) Validation and usefulness of a computer-assisted cup-positioning system in total hip arthroplasty. A prospective, randomized, controlled study. J Bone Joint Surg Am 89:494–499PubMedCrossRef
18.
Zurück zum Zitat Richolt JA, Effenberger H, Rittmeister ME (2005) How does soft tissue distribution affect anteversion accuracy of the palpation procedure in image-free acetabular cup navigation? An ultrasonographic assessment. Comput Aided Surg 10:87–92PubMedCrossRef Richolt JA, Effenberger H, Rittmeister ME (2005) How does soft tissue distribution affect anteversion accuracy of the palpation procedure in image-free acetabular cup navigation? An ultrasonographic assessment. Comput Aided Surg 10:87–92PubMedCrossRef
19.
Zurück zum Zitat Saragaglia D, Picard F, Chaussard C, Montbarbon E, Leitner F, Cinquin P (2001) Computer-assisted knee arthroplasty: comparison with a conventional procedure. Results of 50 cases in a prospective randomized study. Rev Chir Orthop Reparatrice Appar Mot 87:18–28PubMed Saragaglia D, Picard F, Chaussard C, Montbarbon E, Leitner F, Cinquin P (2001) Computer-assisted knee arthroplasty: comparison with a conventional procedure. Results of 50 cases in a prospective randomized study. Rev Chir Orthop Reparatrice Appar Mot 87:18–28PubMed
20.
Zurück zum Zitat Spencer JMF, Day RE, Sloan KE, Beaver RJ (2006) Computer navigation of the acetabular component: a cadaver reliability study. J Bone Joint Surg Br 88:972–975PubMedCrossRef Spencer JMF, Day RE, Sloan KE, Beaver RJ (2006) Computer navigation of the acetabular component: a cadaver reliability study. J Bone Joint Surg Br 88:972–975PubMedCrossRef
21.
Zurück zum Zitat Sugano N, Nishii T, Miki H, Yoshikawa H, Sato Y, Tamura S (2007) Mid-term results of cementless total hip replacement using a ceramic-on-ceramic bearing with and without computer navigation. J Bone Joint Surg Br 89:455–460PubMedCrossRef Sugano N, Nishii T, Miki H, Yoshikawa H, Sato Y, Tamura S (2007) Mid-term results of cementless total hip replacement using a ceramic-on-ceramic bearing with and without computer navigation. J Bone Joint Surg Br 89:455–460PubMedCrossRef
22.
Zurück zum Zitat Tannast M, Murphy SB, Langlotz F, Anderson SE, Siebenrock KA (2006) Estimation of pelvic tilt on anteroposterior X-rays—a comparison of six parameters. Skeletal Radiol 35:149–155PubMedCrossRef Tannast M, Murphy SB, Langlotz F, Anderson SE, Siebenrock KA (2006) Estimation of pelvic tilt on anteroposterior X-rays—a comparison of six parameters. Skeletal Radiol 35:149–155PubMedCrossRef
23.
Zurück zum Zitat Wines AP, McNicol D (2006) Computed tomography measurement of the accuracy of component version in total hip arthroplasty. J Arthroplasty 21:696–701PubMedCrossRef Wines AP, McNicol D (2006) Computed tomography measurement of the accuracy of component version in total hip arthroplasty. J Arthroplasty 21:696–701PubMedCrossRef
24.
Zurück zum Zitat Wolf A, Digioia AM 3rd, Mor AB, Jaramaz B (2005) Cup alignment error model for total hip arthroplasty. Clin Orthop Relat Res 437:132–137PubMedCrossRef Wolf A, Digioia AM 3rd, Mor AB, Jaramaz B (2005) Cup alignment error model for total hip arthroplasty. Clin Orthop Relat Res 437:132–137PubMedCrossRef
Metadaten
Titel
Navigated non-image-based positioning of the acetabulum during total hip replacement
verfasst von
Jean-Yves Jenny
Cyril Boeri
Jean-Claude Dosch
Marius Uscatu
Eugen Ciobanu
Publikationsdatum
01.02.2009
Verlag
Springer-Verlag
Erschienen in
International Orthopaedics / Ausgabe 1/2009
Print ISSN: 0341-2695
Elektronische ISSN: 1432-5195
DOI
https://doi.org/10.1007/s00264-007-0479-6

Weitere Artikel der Ausgabe 1/2009

International Orthopaedics 1/2009 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.