Skip to main content
Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy 6/2018

12.10.2017 | Knee

Neutral alignment leads to higher knee society scores after total knee arthroplasty in preoperatively non-varus patients: a prospective clinical study using 3D-CT

verfasst von: Omer Slevin, Anna Hirschmann, Filippo F. Schiapparelli, Felix Amsler, Rolf W. Huegli, Michael T. Hirschmann

Erschienen in: Knee Surgery, Sports Traumatology, Arthroscopy | Ausgabe 6/2018

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The optimal coronal alignment is still under debate. However, in most of the studies, alignment was only assessed using radiographs, which are not accurate enough for assessment of tibial and femoral TKA position. The primary purpose of this study was to assess the relationship between coronal TKA alignment using 3D-reconstructed CTs and clinical outcome in patients with preoperative varus in comparison with patients with natural or valgus deformity. It was the hypothesis that neutral limb alignment shows a better outcome after TKA.

Methods

Prospectively collected data of 38 patients were included. The clinical and radiological follow-up was 24 months. The patients were grouped into two groups with regard to their preoperative limb alignment. Group A (varus) consisted of 21 patients with preoperative varus of 3° or more, while group B (non-varus) consisted of 17 patients with neutral (− 3 < 0 > + 3) or valgus alignment (> + 3). For assessment of TKA component position and orientation, 3D-reconstructed CT was used. The measurements of the deviation from the whole limb mechanical axis (HKA angle) and the joint line alignment in the femoral (mLDFA) and the tibial side (MPTA) were assessed in the preoperative leg as well as during follow-up after TKA. For clinical outcome assessment, the Knee Society Score (KSS) was used at 1 and 2 years postoperatively. Correlation between KSS score and each variable was done using a linear and quadratic regression model (p < 0.05).

Results

The mean postoperative HKA angle was − 1.3 (varus) in the varus group and + 1.4 (valgus) in the non-varus group. Overall, significant correlations between the preoperative and postoperative alignments were found. In the preoperatively non-varus group, a highly significant correlation was found between neutral limb alignment (HKA = 0° ± 3°) and higher KSS (r 2 = 0.74, p = 0.00). In the varus group, no correlation was found between the postoperative whole limb alignment and the components’ position in the coronal plane to KSS score.

Conclusion

A significant correlation was found between neutral limb alignment and higher KSS only in patients with preoperative non-varus alignment. The concept of constitutional varus alignment is still under debate. Moreover, it appears that one should aim for a more individualized, alignment target based on the individual knee morphotype.

Level of evidence

Diagnostic study, Level II.
Literatur
1.
Zurück zum Zitat Abdel MP, Oussedik S, Parratte S, Lustig S, Haddad FS (2014) Coronal alignment in total knee replacement: historical review, contemporary analysis, and future direction. Bone Jt J 96–B:857–862CrossRef Abdel MP, Oussedik S, Parratte S, Lustig S, Haddad FS (2014) Coronal alignment in total knee replacement: historical review, contemporary analysis, and future direction. Bone Jt J 96–B:857–862CrossRef
2.
Zurück zum Zitat Anderl W, Pauzenberger L, Kölblinger R, Kiesselbach G, Brandl G, Laky B, Kriegleder B, Heuberer P, Schwameis E (2016) Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA. Knee Surg Sports Traumatol Arthrosc 24:102–111CrossRefPubMed Anderl W, Pauzenberger L, Kölblinger R, Kiesselbach G, Brandl G, Laky B, Kriegleder B, Heuberer P, Schwameis E (2016) Patient-specific instrumentation improved mechanical alignment, while early clinical outcome was comparable to conventional instrumentation in TKA. Knee Surg Sports Traumatol Arthrosc 24:102–111CrossRefPubMed
3.
Zurück zum Zitat Becker R, Döring C, Denecke A, Brosz M (2011) Expectation, satisfaction and clinical outcome of patients after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 19:1433–1441CrossRefPubMed Becker R, Döring C, Denecke A, Brosz M (2011) Expectation, satisfaction and clinical outcome of patients after total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 19:1433–1441CrossRefPubMed
4.
Zurück zum Zitat Bellemans J, Colyn W, Vandenneucker H, Victor J (2012) The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res 470:45–53CrossRefPubMed Bellemans J, Colyn W, Vandenneucker H, Victor J (2012) The Chitranjan Ranawat award: is neutral mechanical alignment normal for all patients? The concept of constitutional varus. Clin Orthop Relat Res 470:45–53CrossRefPubMed
5.
Zurück zum Zitat Blakeney WG, Khan RJK, Palmer JL (2014) Functional outcomes following total knee arthroplasty: a randomised trial comparing computer-assisted surgery with conventional techniques. Knee 21:364–368CrossRefPubMed Blakeney WG, Khan RJK, Palmer JL (2014) Functional outcomes following total knee arthroplasty: a randomised trial comparing computer-assisted surgery with conventional techniques. Knee 21:364–368CrossRefPubMed
6.
Zurück zum Zitat Bonner TJ, Eardley WG, Patterson P, Gregg PJ (2011) The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years. J Bone Jt Surg Br 93:1217–1222CrossRef Bonner TJ, Eardley WG, Patterson P, Gregg PJ (2011) The effect of post-operative mechanical axis alignment on the survival of primary total knee replacements after a follow-up of 15 years. J Bone Jt Surg Br 93:1217–1222CrossRef
7.
Zurück zum Zitat Bourne RB, Chesworth BM, Davis AM, Mahomed NN, Charron KDJ (2010) Patient Satisfaction after Total Knee Arthroplasty: Who is Satisfied and Who is Not? Clin Orthop Relat Res 468:57–63CrossRefPubMed Bourne RB, Chesworth BM, Davis AM, Mahomed NN, Charron KDJ (2010) Patient Satisfaction after Total Knee Arthroplasty: Who is Satisfied and Who is Not? Clin Orthop Relat Res 468:57–63CrossRefPubMed
8.
Zurück zum Zitat Choong PF, Dowsey MM, Stoney JD (2016) Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and computer-assisted total knee arthroplasty. J Arthroplast 24:560–569CrossRef Choong PF, Dowsey MM, Stoney JD (2016) Does accurate anatomical alignment result in better function and quality of life? Comparing conventional and computer-assisted total knee arthroplasty. J Arthroplast 24:560–569CrossRef
9.
Zurück zum Zitat D’Lima DD, Chen PC, Colwell CWJ (2001) Polyethylene contact stresses, articular congruity, and knee alignment. Clin Orthop Relat Res 392:232–238CrossRef D’Lima DD, Chen PC, Colwell CWJ (2001) Polyethylene contact stresses, articular congruity, and knee alignment. Clin Orthop Relat Res 392:232–238CrossRef
10.
Zurück zum Zitat Delport H, Labey L, Innocenti B, De Corte R, Vander Sloten J, Bellemans J (2014) Restoration of constitutional alignment in TKA leads to more physiological strains in the collateral ligaments. Knee Surg Sports Traumatol Arthrosc 23:2159–2169CrossRefPubMed Delport H, Labey L, Innocenti B, De Corte R, Vander Sloten J, Bellemans J (2014) Restoration of constitutional alignment in TKA leads to more physiological strains in the collateral ligaments. Knee Surg Sports Traumatol Arthrosc 23:2159–2169CrossRefPubMed
11.
Zurück zum Zitat Gromov K, Korchi M, Thomsen MG, Husted H, Troelsen A (2014) What is the optimal alignment of the tibial and femoral components in knee arthroplasty? Acta Orthop 85:480–487CrossRefPubMedPubMedCentral Gromov K, Korchi M, Thomsen MG, Husted H, Troelsen A (2014) What is the optimal alignment of the tibial and femoral components in knee arthroplasty? Acta Orthop 85:480–487CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Henckel J, Richards R, Lozhkin K, Harris S, Rodriguez y Baena FM, Barrett AR, Cobb JP (2006) Very low-dose computed tomography for planning and outcome measurement in knee replacement. The imperial knee protocol. J Bone Jt Surg Br 88:1513–1518CrossRef Henckel J, Richards R, Lozhkin K, Harris S, Rodriguez y Baena FM, Barrett AR, Cobb JP (2006) Very low-dose computed tomography for planning and outcome measurement in knee replacement. The imperial knee protocol. J Bone Jt Surg Br 88:1513–1518CrossRef
13.
Zurück zum Zitat Hirschmann MT, Amsler F, Rasch H (2015) Clinical value of SPECT/CT in the painful total knee arthroplasty (TKA): a prospective study in a consecutive series of 100 TKA. Eur J Nucl Med Mol Imaging 42:1869–1882CrossRefPubMed Hirschmann MT, Amsler F, Rasch H (2015) Clinical value of SPECT/CT in the painful total knee arthroplasty (TKA): a prospective study in a consecutive series of 100 TKA. Eur J Nucl Med Mol Imaging 42:1869–1882CrossRefPubMed
14.
Zurück zum Zitat Hirschmann MT, Iranpour F, Konala P, Kerner A, Rasch H, Cobb JP, Friederich NF (2010) A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography. Knee Surg Sports Traumatol Arthrosc 18:939–944CrossRefPubMed Hirschmann MT, Iranpour F, Konala P, Kerner A, Rasch H, Cobb JP, Friederich NF (2010) A novel standardized algorithm for evaluating patients with painful total knee arthroplasty using combined single photon emission tomography and conventional computerized tomography. Knee Surg Sports Traumatol Arthrosc 18:939–944CrossRefPubMed
15.
Zurück zum Zitat Hirschmann MT, Konala P, Amsler F, Iranpour F, Friederich NF, Cobb JP (2011) The position and orientation of total knee replacement components: a comparison of conventional radiographs, transverse 2D-CT slices and 3D-CT reconstruction. J Bone Jt Surg Br 93:629–633CrossRef Hirschmann MT, Konala P, Amsler F, Iranpour F, Friederich NF, Cobb JP (2011) The position and orientation of total knee replacement components: a comparison of conventional radiographs, transverse 2D-CT slices and 3D-CT reconstruction. J Bone Jt Surg Br 93:629–633CrossRef
16.
Zurück zum Zitat Hirschmann MT, Müller W (2015) Complex function of the knee joint: the current understanding of the knee. Knee Surg Sports Traumatol Arthrosc 23:2780–2788CrossRefPubMed Hirschmann MT, Müller W (2015) Complex function of the knee joint: the current understanding of the knee. Knee Surg Sports Traumatol Arthrosc 23:2780–2788CrossRefPubMed
17.
Zurück zum Zitat Hirschmann MT, Testa E, Amsler F, Friederich NF (2013) The unhappy total knee arthroplasty (TKA) patient: Higher WOMAC and lower KSS in depressed patients prior and after TKA. Knee Surg Sports Traumatol Arthrosc 21:2405–2411CrossRefPubMed Hirschmann MT, Testa E, Amsler F, Friederich NF (2013) The unhappy total knee arthroplasty (TKA) patient: Higher WOMAC and lower KSS in depressed patients prior and after TKA. Knee Surg Sports Traumatol Arthrosc 21:2405–2411CrossRefPubMed
18.
Zurück zum Zitat Howell SM, Howell SJ, Kuznik KT, Cohen J, Hull ML (2013) Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category? Clin Orthop Relat Res 471:1000–1007CrossRefPubMed Howell SM, Howell SJ, Kuznik KT, Cohen J, Hull ML (2013) Does a kinematically aligned total knee arthroplasty restore function without failure regardless of alignment category? Clin Orthop Relat Res 471:1000–1007CrossRefPubMed
19.
Zurück zum Zitat Hsu HP, Garg A, Walker PS, Spector M, Ewald FC (1989) Effect of knee component alignment on tibial load distribution with clinical correlation. Clin Orthop Relat Res 248:135–144 Hsu HP, Garg A, Walker PS, Spector M, Ewald FC (1989) Effect of knee component alignment on tibial load distribution with clinical correlation. Clin Orthop Relat Res 248:135–144
20.
Zurück zum Zitat Huijbregts HJTAM, Khan RJK, Fick DP, Jarrett OM, Haebich S (2016) Prosthetic alignment after total knee replacement is not associated with dissatisfaction or change in Oxford Knee Score. Knee 23:535–539CrossRefPubMed Huijbregts HJTAM, Khan RJK, Fick DP, Jarrett OM, Haebich S (2016) Prosthetic alignment after total knee replacement is not associated with dissatisfaction or change in Oxford Knee Score. Knee 23:535–539CrossRefPubMed
21.
Zurück zum Zitat Insall JN, Binazzi R, Soudry M, Mestriner LA (1985) Total knee arthroplasty. Clin Orthop Relat Res 192:13–22 Insall JN, Binazzi R, Soudry M, Mestriner LA (1985) Total knee arthroplasty. Clin Orthop Relat Res 192:13–22
22.
Zurück zum Zitat Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 248:13–14 Insall JN, Dorr LD, Scott RD, Scott WN (1989) Rationale of the Knee Society clinical rating system. Clin Orthop Relat Res 248:13–14
23.
Zurück zum Zitat Kuster M, Bistschnau B, Votruba T (2004) Influence of collateral ligament laxity on patient satisfaction after total knee arthroplasty : a comparative bilateral study. Arch Orthop Trauma Surg 124:415–417CrossRefPubMed Kuster M, Bistschnau B, Votruba T (2004) Influence of collateral ligament laxity on patient satisfaction after total knee arthroplasty : a comparative bilateral study. Arch Orthop Trauma Surg 124:415–417CrossRefPubMed
24.
Zurück zum Zitat Lee B-S, Lee S-J, Kim J-M, Lee D-H, Cha E-J, Bin S-I (2011) No impact of severe varus deformity on clinical outcome after posterior stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 19:960–966CrossRefPubMed Lee B-S, Lee S-J, Kim J-M, Lee D-H, Cha E-J, Bin S-I (2011) No impact of severe varus deformity on clinical outcome after posterior stabilized total knee arthroplasty. Knee Surg Sports Traumatol Arthrosc 19:960–966CrossRefPubMed
25.
Zurück zum Zitat Longstaff LM, Sloan K, Stamp N, Scaddan M, Beaver R (2009) Good alignment after total knee arthroplasty leads to faster rehabilitation and better function. J Arthroplast 24:570–578CrossRef Longstaff LM, Sloan K, Stamp N, Scaddan M, Beaver R (2009) Good alignment after total knee arthroplasty leads to faster rehabilitation and better function. J Arthroplast 24:570–578CrossRef
26.
Zurück zum Zitat Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Jt Surg Am 59:77–79CrossRef Lotke PA, Ecker ML (1977) Influence of positioning of prosthesis in total knee replacement. J Bone Jt Surg Am 59:77–79CrossRef
27.
Zurück zum Zitat Manjunath KS, Gopalakrishna KG, Vineeth G (2015) Evaluation of alignment in total knee arthroplasty: a prospective study. Eur J Orthop Surg Traumatol 25:895–903CrossRefPubMed Manjunath KS, Gopalakrishna KG, Vineeth G (2015) Evaluation of alignment in total knee arthroplasty: a prospective study. Eur J Orthop Surg Traumatol 25:895–903CrossRefPubMed
28.
Zurück zum Zitat Matsuda S, Whiteside LA, White SE (1999) The effect of varus tilt on contact stresses in total knee arthroplasty: a biomechanical study. Orthopedics 22:303–307PubMed Matsuda S, Whiteside LA, White SE (1999) The effect of varus tilt on contact stresses in total knee arthroplasty: a biomechanical study. Orthopedics 22:303–307PubMed
29.
Zurück zum Zitat Matziolis G, Adam J, Perka C (2010) Varus malalignment has no influence on clinical outcome in midterm follow-up after total knee replacement. Arch Orthop Trauma Surg 130:1487–1491CrossRefPubMed Matziolis G, Adam J, Perka C (2010) Varus malalignment has no influence on clinical outcome in midterm follow-up after total knee replacement. Arch Orthop Trauma Surg 130:1487–1491CrossRefPubMed
30.
Zurück zum Zitat Mugnai R, Zambianchi F, Digennaro V, Marcovigi A, Tarallo L, Del Giovane C, Catani F (2016) Clinical outcome is not affected by total knee arthroplasty alignment. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-016-4094-1 PubMedCrossRef Mugnai R, Zambianchi F, Digennaro V, Marcovigi A, Tarallo L, Del Giovane C, Catani F (2016) Clinical outcome is not affected by total knee arthroplasty alignment. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-016-4094-1 PubMedCrossRef
31.
Zurück zum Zitat Parratte S, Pagnano MW, Trousdale RT, Berry DJ (2010) Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Jt Surg Am 92:2143–2149CrossRef Parratte S, Pagnano MW, Trousdale RT, Berry DJ (2010) Effect of postoperative mechanical axis alignment on the fifteen-year survival of modern, cemented total knee replacements. J Bone Jt Surg Am 92:2143–2149CrossRef
32.
Zurück zum Zitat Perillo-Marcone A, Barrett DS, Taylor M (2000) The importance of tibial alignment: finite element analysis of tibial malalignment. J Arthroplasty 15:1020–1027CrossRefPubMed Perillo-Marcone A, Barrett DS, Taylor M (2000) The importance of tibial alignment: finite element analysis of tibial malalignment. J Arthroplasty 15:1020–1027CrossRefPubMed
33.
Zurück zum Zitat Radtke K, Becher C, Noll Y, Ostermeier S (2010) Effect of limb rotation on radiographic alignment in total knee arthroplasties. Arch Orthop Trauma Surg 130:451–457CrossRefPubMed Radtke K, Becher C, Noll Y, Ostermeier S (2010) Effect of limb rotation on radiographic alignment in total knee arthroplasties. Arch Orthop Trauma Surg 130:451–457CrossRefPubMed
34.
Zurück zum Zitat Rasch H, Falkowski AL, Forrer F, Henckel J, Hirschmann MT (2013) 4D-SPECT/CT in orthopaedics: a new method of combined quantitative volumetric 3D analysis of SPECT/CT tracer uptake and component position measurements in patients after total knee arthroplasty. Skelet Radiol 42:1215–1223CrossRef Rasch H, Falkowski AL, Forrer F, Henckel J, Hirschmann MT (2013) 4D-SPECT/CT in orthopaedics: a new method of combined quantitative volumetric 3D analysis of SPECT/CT tracer uptake and component position measurements in patients after total knee arthroplasty. Skelet Radiol 42:1215–1223CrossRef
35.
Zurück zum Zitat Scott CEH, Howie CR, MacDonald D, Biant LC (2010) Predicting dissatisfaction following total knee replacement: a prospective study of 1217 patients. J Bone Jt Surg Br 92:1253–1258CrossRef Scott CEH, Howie CR, MacDonald D, Biant LC (2010) Predicting dissatisfaction following total knee replacement: a prospective study of 1217 patients. J Bone Jt Surg Br 92:1253–1258CrossRef
36.
Zurück zum Zitat Sikorski JM (2008) Alignment in total knee replacement. J Bone Jt Surg Br 90:1121–11277CrossRef Sikorski JM (2008) Alignment in total knee replacement. J Bone Jt Surg Br 90:1121–11277CrossRef
37.
Zurück zum Zitat Skytta ET, Lohman M, Tallroth K, Remes V (2009) Comparison of standard anteroposterior knee and hip-to-ankle radiographs in determining the lower limb and implant alignment after total knee arthroplasty. Scand J Surg 98:250–253CrossRefPubMed Skytta ET, Lohman M, Tallroth K, Remes V (2009) Comparison of standard anteroposterior knee and hip-to-ankle radiographs in determining the lower limb and implant alignment after total knee arthroplasty. Scand J Surg 98:250–253CrossRefPubMed
38.
Zurück zum Zitat Slevin O, Amsler F, Hirschmann MT (2016) No correlation between coronal alignment of total knee arthroplasty and clinical outcomes: a prospective clinical study using 3D-CT. Knee Surg Sports Traumatol Arthrosc. doi:10.1007/s00167-016-4400-y CrossRefPubMed Slevin O, Amsler F, Hirschmann MT (2016) No correlation between coronal alignment of total knee arthroplasty and clinical outcomes: a prospective clinical study using 3D-CT. Knee Surg Sports Traumatol Arthrosc. doi:10.​1007/​s00167-016-4400-y CrossRefPubMed
39.
Zurück zum Zitat Vandekerckhove P-J, Lanting B, Bellemans J, Victor J, MacDonald S (2016) The current role of coronal plane alignment in Total Knee Arthroplasty in a preoperative varus aligned population: an evidence based review. Acta Orthop Belg 82:129–142PubMed Vandekerckhove P-J, Lanting B, Bellemans J, Victor J, MacDonald S (2016) The current role of coronal plane alignment in Total Knee Arthroplasty in a preoperative varus aligned population: an evidence based review. Acta Orthop Belg 82:129–142PubMed
40.
Zurück zum Zitat Vanlommel L, Vanlommel J, Claes S, Bellemans J (2013) Slight undercorrection following total knee arthroplasty results in superior clinical outcomes in varus knees. Knee Surg Sports Traumatol Arthrosc 21:2325–2330CrossRefPubMed Vanlommel L, Vanlommel J, Claes S, Bellemans J (2013) Slight undercorrection following total knee arthroplasty results in superior clinical outcomes in varus knees. Knee Surg Sports Traumatol Arthrosc 21:2325–2330CrossRefPubMed
41.
Zurück zum Zitat Wagner CR, Hirschmann MT, Beasley RA (2015) Specific orthopaedic imaging analysis software: clinical benefit from TKR revision surgeon. In: Hirschmann MT, Becker R (eds) The unhappy total knee replacement: a comprehensive review and management guide. Springer, Cham, pp 69–83. doi:10.1007/978-3-319-08099-4 Wagner CR, Hirschmann MT, Beasley RA (2015) Specific orthopaedic imaging analysis software: clinical benefit from TKR revision surgeon. In: Hirschmann MT, Becker R (eds) The unhappy total knee replacement: a comprehensive review and management guide. Springer, Cham, pp 69–83. doi:10.​1007/​978-3-319-08099-4
Metadaten
Titel
Neutral alignment leads to higher knee society scores after total knee arthroplasty in preoperatively non-varus patients: a prospective clinical study using 3D-CT
verfasst von
Omer Slevin
Anna Hirschmann
Filippo F. Schiapparelli
Felix Amsler
Rolf W. Huegli
Michael T. Hirschmann
Publikationsdatum
12.10.2017
Verlag
Springer Berlin Heidelberg
Erschienen in
Knee Surgery, Sports Traumatology, Arthroscopy / Ausgabe 6/2018
Print ISSN: 0942-2056
Elektronische ISSN: 1433-7347
DOI
https://doi.org/10.1007/s00167-017-4744-y

Weitere Artikel der Ausgabe 6/2018

Knee Surgery, Sports Traumatology, Arthroscopy 6/2018 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.