Erschienen in:
27.10.2018 | KNEE
New design total knee arthroplasty shows medial pivoting movement under weight-bearing conditions
verfasst von:
Laura Bragonzoni, Giulio Maria Marcheggiani Muccioli, Marco Bontempi, Tommaso Roberti di Sarsina, Umberto Cardinale, Domenico Alesi, Francesco Iacono, Maria Pia Neri, Stefano Zaffagnini
Erschienen in:
Knee Surgery, Sports Traumatology, Arthroscopy
|
Ausgabe 4/2019
Einloggen, um Zugang zu erhalten
Abstract
Purpose
To assess, using model-based dynamic radiostereometric analysis (RSA), the biomechanical behaviour of a new design posterior-stabilized (PS) fixed-bearing (FB) total knee arthroplasty (TKA) in vivo while patients performing two common motor tasks. The hypothesis was that model-based dynamic RSA is able to detect different behaviour of the implant under weight-bearing and non-weight-bearing conditions.
Methods
A cohort of 15 non-consecutive patients was evaluated by dynamic RSA 9 months after TKA implantation. The mean age of patients was 73.4 (65–72) years. The kinematic evaluations were performed using an RSA device (BI-STAND DRX 2) developed in our Institute. The patients were asked to perform two active motor tasks: sit-to-stand in weight-bearing condition; range of motion (ROM) while sitting on the chair. The motion parameters were evaluated using the Grood and Suntay decomposition and the low-point kinematics methods.
Results
The dynamic RSA evaluation showed a significant difference (p < 0.05) between the biomechanical behaviour of the prosthesis during the two motor tasks. When subjected to the patient weight (in the sit-to-stand) the low point of the medial compartment had a shorter motion (5.7 ± 0.2 mm) than the lateral (11.0 ± 0.2 mm). This realizes a medial pivot motion as in the normal knee. In the ROM task, where the patient had no weight on the prosthesis, this difference was not present: the medial compartment had a displacement of 12.7 ± 0.2 mm, while the lateral had 17.3 ± 0.2 mm.
Conclusions
Model-based RSA proved to be an effective tool for the evaluation of TKA biomechanics. In particular, it was able to determine that the fixed-bearing posterior-stabilized TKA design evaluated in this study showed a medial pivoting movement under weight-bearing conditions that was not present when load was not applied. Under loading conditions what drives the pattern of movement is the prosthetic design itself. By the systematic use of this study protocol future comparisons among different implants could be performed, thus contributing significantly to the improvement of TKA design.