New method to measure and improve consistency of baroreflex sensitivity values

verfasst von: Luciano Bernardi, Giacomo De Barbieri, Milla Rosengård-Bärlund, Ville-Petteri Mäkinen, Cesare Porta, Per-Henrik Groop

Erschienen in: Clinical Autonomic Research | Ausgabe 6/2010

Einloggen, um Zugang zu erhalten

Abstract

Objective

Baroreflex sensitivity (BRS) is an important prognostic index in cardiovascular diseases, however, its use is complicated by different methods difficult to compare and standardize, often providing conflicting results. We tested whether the simple ratio of RR interval to systolic blood pressure global variabilities (assessed by standard deviations) is a reliable measure of BRS, by measuring the agreement with six established methods. In addition, we tested whether high-pass filtering of data, by removing slow non-baroreflex-mediated fluctuations, could improve the agreement between different BRS methods.

Methods

In 1,409 subjects, we compared 6 established methods (derived by cross-spectral and sequence analysis) and the new method, supine and in response to tilting (1,175 subjects). Data were analyzed after linear detrending, high-pass filtering at 0.025 and 0.05 Hz.

Results

Although all seven methods showed a general agreement, the new method consistently showed the lowest distance from the median of the remaining methods (0.04 ± 0.06 ms/mmHg over 2,584 files, p < 0.05 with respect to the second best method). High-pass filtering improved (p < 0.001) the agreement between methods without reducing the sensitivity to changes induced by tilting. Only the new method could provide estimates in all 2,584 files tested.

Interpretation

The new method intercepts the mean information of all other methods better than any other method, hence providing a simple, easy to standardize (no mathematical constraints) and yet robust and reliable BRS estimate. High-pass filtering markedly improves the agreement of all methods, without loss of sensitivity, and could be routinely used in clinical trials, to provide comparable BRS estimates.
Literatur
1.
Zurück zum Zitat La Rovere MT, Bigger JT Jr, Marcus FI, Mortara A, Schwartz PJ (1998) Baroreflex sensitivity and heart-rate variability in prediction of total cardiac mortality after myocardial infarction. ATRAMI (Autonomic Tone and Reflexes After Myocardial Infarction) Investigators. Lancet 351:478–484CrossRefPubMed La Rovere MT, Bigger JT Jr, Marcus FI, Mortara A, Schwartz PJ (1998) Baroreflex sensitivity and heart-rate variability in prediction of total cardiac mortality after myocardial infarction. ATRAMI (Autonomic Tone and Reflexes After Myocardial Infarction) Investigators. Lancet 351:478–484CrossRefPubMed
2.
Zurück zum Zitat Sykora M, Diedler J, Rupp A, Turcani P, Rocco A, Steiner T (2008) Impaired baroreflex sensitivity predicts outcome of acute intracerebral hemorrhage. Crit Care Med 36:3074–3079CrossRefPubMed Sykora M, Diedler J, Rupp A, Turcani P, Rocco A, Steiner T (2008) Impaired baroreflex sensitivity predicts outcome of acute intracerebral hemorrhage. Crit Care Med 36:3074–3079CrossRefPubMed
3.
Zurück zum Zitat Johansson M, Gao SA, Friberg P et al (2007) Baroreflex effectiveness index and baroreflex sensitivity predict all-cause mortality and sudden death in hypertensive patients with chronic renal failure. J Hypertens 25:163–168CrossRefPubMed Johansson M, Gao SA, Friberg P et al (2007) Baroreflex effectiveness index and baroreflex sensitivity predict all-cause mortality and sudden death in hypertensive patients with chronic renal failure. J Hypertens 25:163–168CrossRefPubMed
4.
Zurück zum Zitat Ormezzano O, Cracowski JL, Quesada JL, Pierre H, Mallion JM, Baguet JP (2008) EVAluation of the prognostic value of BARoreflex sensitivity in hypertensive patients: the EVABAR study. J Hypertens 26:1373–1378CrossRefPubMed Ormezzano O, Cracowski JL, Quesada JL, Pierre H, Mallion JM, Baguet JP (2008) EVAluation of the prognostic value of BARoreflex sensitivity in hypertensive patients: the EVABAR study. J Hypertens 26:1373–1378CrossRefPubMed
5.
Zurück zum Zitat Smyth HS, Sleight P, Pickering GW (1969) Reflex regulation of arterial pressure during sleep in man. A quantitative method of assessing baroreflex sensitivity. Circ Res 24:109–121PubMed Smyth HS, Sleight P, Pickering GW (1969) Reflex regulation of arterial pressure during sleep in man. A quantitative method of assessing baroreflex sensitivity. Circ Res 24:109–121PubMed
6.
Zurück zum Zitat Laude D, Elghozi JL, Girard A et al (2004) Comparison of various techniques used to estimate spontaneous baroreflex sensitivity (the EuroBaVar study). Am J Physiol (Regul Integr Comp Physiol) 286:R226–R231 Laude D, Elghozi JL, Girard A et al (2004) Comparison of various techniques used to estimate spontaneous baroreflex sensitivity (the EuroBaVar study). Am J Physiol (Regul Integr Comp Physiol) 286:R226–R231
7.
Zurück zum Zitat Pitzalis MV, Mastropasqua F, Passantino A et al (1998) Comparison between noninvasive indices of baroreceptor sensitivity and the phenylephrine method in post-myocardial infarction patients. Circulation 97:1362–1367PubMed Pitzalis MV, Mastropasqua F, Passantino A et al (1998) Comparison between noninvasive indices of baroreceptor sensitivity and the phenylephrine method in post-myocardial infarction patients. Circulation 97:1362–1367PubMed
8.
Zurück zum Zitat Maestri R, Pinna GD, Mortara A, La Rovere MT, Tavazzi L (1998) Assessing baroreflex sensitivity in post-myocardial infarction patients: comparison of spectral and phenylephrine techniques. J Am Coll Cardiol 31:344–351CrossRefPubMed Maestri R, Pinna GD, Mortara A, La Rovere MT, Tavazzi L (1998) Assessing baroreflex sensitivity in post-myocardial infarction patients: comparison of spectral and phenylephrine techniques. J Am Coll Cardiol 31:344–351CrossRefPubMed
9.
Zurück zum Zitat Colombo R, Mazzuero G, Spinatonda G et al (1999) Comparison between spectral analysis and the phenylephrine method for the assessment of baroreflex sensitivity in chronic heart failure. Clin Sci (Lond) 97:503–513CrossRef Colombo R, Mazzuero G, Spinatonda G et al (1999) Comparison between spectral analysis and the phenylephrine method for the assessment of baroreflex sensitivity in chronic heart failure. Clin Sci (Lond) 97:503–513CrossRef
10.
Zurück zum Zitat Rosengård-Bärlund M, Bernardi L, Fagerudd J et al (2009) Early autonomic dysfunction in type 1 diabetes: a reversible disorder? Diabetologia 52:1164–1172CrossRefPubMed Rosengård-Bärlund M, Bernardi L, Fagerudd J et al (2009) Early autonomic dysfunction in type 1 diabetes: a reversible disorder? Diabetologia 52:1164–1172CrossRefPubMed
11.
Zurück zum Zitat Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310PubMed Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310PubMed
12.
Zurück zum Zitat Bertinieri G, Di Rienzo M, Cavallazzi A, Ferrari AU, Pedotti A, Mancia G (1985) A new approach to analysis of the arterial baroreflex. J Hypertens Suppl 3:S79–S81PubMed Bertinieri G, Di Rienzo M, Cavallazzi A, Ferrari AU, Pedotti A, Mancia G (1985) A new approach to analysis of the arterial baroreflex. J Hypertens Suppl 3:S79–S81PubMed
13.
Zurück zum Zitat Pagani M, Somers V, Furlan R et al (1988) Changes in autonomic regulation induced by physical training in mild hypertension. Hypertension 12:600–610PubMed Pagani M, Somers V, Furlan R et al (1988) Changes in autonomic regulation induced by physical training in mild hypertension. Hypertension 12:600–610PubMed
14.
Zurück zum Zitat Pinna GD, Maestri R (2001) Reliability of transfer function estimates in cardiovascular variability analysis. Med Biol Eng Comput 39:338–347CrossRefPubMed Pinna GD, Maestri R (2001) Reliability of transfer function estimates in cardiovascular variability analysis. Med Biol Eng Comput 39:338–347CrossRefPubMed
15.
Zurück zum Zitat Bland JM, Altman DG (1997) Cronbach’s alpha. Br Med J 314:572 Bland JM, Altman DG (1997) Cronbach’s alpha. Br Med J 314:572
16.
Zurück zum Zitat Bravo G, Potvin L (1991) Estimating the reliability of continuous measures with Cronbach’s alpha or the intraclass correlation coefficient: toward the integration of two traditions. J Clin Epidemiol 44:381–390CrossRefPubMed Bravo G, Potvin L (1991) Estimating the reliability of continuous measures with Cronbach’s alpha or the intraclass correlation coefficient: toward the integration of two traditions. J Clin Epidemiol 44:381–390CrossRefPubMed
17.
Zurück zum Zitat Mäkinen VP, Forsblom C, Thorn LM et al (2009) Network of clinical and biochemical characteristics in a set of 4,197 patients with type 1 diabetes. Cardiovasc Diabetol 8:54–59CrossRefPubMed Mäkinen VP, Forsblom C, Thorn LM et al (2009) Network of clinical and biochemical characteristics in a set of 4,197 patients with type 1 diabetes. Cardiovasc Diabetol 8:54–59CrossRefPubMed
18.
19.
Zurück zum Zitat Mäkinen VP, Forsblom C, Thorn LM et al (2008) Metabolic phenotypes, vascular complications, and premature deaths in a population of 4, 197 patients with type 1 diabetes. Diabetes 57:2480–2487CrossRefPubMed Mäkinen VP, Forsblom C, Thorn LM et al (2008) Metabolic phenotypes, vascular complications, and premature deaths in a population of 4, 197 patients with type 1 diabetes. Diabetes 57:2480–2487CrossRefPubMed
20.
Zurück zum Zitat Ziegler D, Laude D, Akila F, Elghozi JL (2001) Time- and frequency-domain estimation of early diabetic cardiovascular autonomic neuropathy. Clin Auton Res 11:369–376CrossRefPubMed Ziegler D, Laude D, Akila F, Elghozi JL (2001) Time- and frequency-domain estimation of early diabetic cardiovascular autonomic neuropathy. Clin Auton Res 11:369–376CrossRefPubMed
21.
Zurück zum Zitat Saul JP, Berger RD, Albrecht P, Stein SP, Chen MH, Cohen RJ (1991) Transfer function analysis of the circulation: unique insights into cardiovascular regulation. Am J Physiol 261:H1231–H1245PubMed Saul JP, Berger RD, Albrecht P, Stein SP, Chen MH, Cohen RJ (1991) Transfer function analysis of the circulation: unique insights into cardiovascular regulation. Am J Physiol 261:H1231–H1245PubMed
Metadaten
Titel
New method to measure and improve consistency of baroreflex sensitivity values
verfasst von
Luciano Bernardi
Giacomo De Barbieri
Milla Rosengård-Bärlund
Ville-Petteri Mäkinen
Cesare Porta
Per-Henrik Groop
Publikationsdatum
01.12.2010
Verlag
Springer-Verlag
Erschienen in
Clinical Autonomic Research / Ausgabe 6/2010
Print ISSN: 0959-9851
Elektronische ISSN: 1619-1560
DOI
https://doi.org/10.1007/s10286-010-0079-1

Weitere Artikel der Ausgabe 6/2010

Clinical Autonomic Research 6/2010 Zur Ausgabe

Review Article

Catecholamines 101