Skip to main content
Erschienen in: European Spine Journal 8/2019

30.04.2019 | Original Article

Noise-optimised virtual monoenergetic imaging of dual-energy CT: effect on metal artefact reduction in patients with lumbar internal fixation

verfasst von: Yanwei Zeng, Kai Deng, Haitao Yang, Yi Tan, Jun Liu, Daoying Geng, Jun Zhang

Erschienen in: European Spine Journal | Ausgabe 8/2019

Einloggen, um Zugang zu erhalten

Abstract

Purpose

The purpose of this study was to evaluate the effects of noise-optimised virtual monoenergetic imaging (VMI+) reconstructions on reducing metal artefacts compared to traditional virtual monoenergetic imaging (VMI) and linearly blended (M_0.6) reconstructions in patients with lumbar metal internal fixation in dual-energy CT (DECT).

Methods

Forty patients who underwent DECT were evaluated in this retrospective study. Images were reconstructed with M_0.6 and with VMI+ and VMI at 10-keV intervals from 40 keV to 190 keV. Attenuation and noise were measured in the hyperdense artefacts, hypodense artefacts, spinal canal, abdominal aorta (AA), and inferior vena cava (IVC). An artefact index (AI) was calculated. A subjective evaluation of the metal–bone interface, surrounding soft tissue, spinal canal, AA, and IVC was conducted.

Results

The AI values for the hypodense artefacts, spinal canal, and IVC were lowest in the 130 keV VMI+ series, for the hyperdense artefacts in the 120 keV VMI+ series, and for the AA in the 190 keV VMI+ series. Except for the hypodense artefacts, the AI values were lower compared to the M_0.6 images and all the VMI series (all p < 0.05). The subjective image quality was highest at 130 keV VMI+ for the metal–bone interface, surrounding soft tissue, AA, and IVC, and at 120 keV VMI+ for the spinal canal. Except for the AA, these rating scores were higher compared to the M_0.6 images and the entire VMI series (all p < 0.05).

Conclusions

DECT with high-keV VMI+ efficiently reduces metal artefacts and shows superior image quality in patients with lumbar internal fixation.

Graphical abstract

These slides can be retrieved from Electronic Supplementary Material.
Anhänge
Nur mit Berechtigung zugänglich
Literatur
6.
Zurück zum Zitat Rosenberg WS, Mummaneni PV (2001) Transforaminal lumbar interbody fusion: technique, complications, and early results. Neurosurgery 48:569–574; discussion 574–565 Rosenberg WS, Mummaneni PV (2001) Transforaminal lumbar interbody fusion: technique, complications, and early results. Neurosurgery 48:569–574; discussion 574–565
7.
Zurück zum Zitat Rajaraman V, Vingan R, Roth P, Heary RF, Conklin L, Jacobs GB (1999) Visceral and vascular complications resulting from anterior lumbar interbody fusion. J Neurosurg 91:60–64PubMed Rajaraman V, Vingan R, Roth P, Heary RF, Conklin L, Jacobs GB (1999) Visceral and vascular complications resulting from anterior lumbar interbody fusion. J Neurosurg 91:60–64PubMed
9.
Zurück zum Zitat Grosse Hokamp N, Neuhaus V, Abdullayev N, Laukamp K, Lennartz S, Mpotsaris A, Borggrefe J (2018) Reduction of artifacts caused by orthopedic hardware in the spine in spectral detector CT examinations using virtual monoenergetic image reconstructions and metal-artifact-reduction algorithms. Skeletal Radiol 47:195–201. https://doi.org/10.1007/s00256-017-2776-5 CrossRefPubMed Grosse Hokamp N, Neuhaus V, Abdullayev N, Laukamp K, Lennartz S, Mpotsaris A, Borggrefe J (2018) Reduction of artifacts caused by orthopedic hardware in the spine in spectral detector CT examinations using virtual monoenergetic image reconstructions and metal-artifact-reduction algorithms. Skeletal Radiol 47:195–201. https://​doi.​org/​10.​1007/​s00256-017-2776-5 CrossRefPubMed
18.
Zurück zum Zitat Frellesen C, Kaup M, Wichmann JL, Husers K, Scholtz JE, Albrecht MH, Metzger SC, Bauer RW, Kerl JM, Lehnert T, Vogl TJ, Bodelle B (2016) Noise-optimized advanced image-based virtual monoenergetic imaging for improved visualization of lung cancer: comparison with traditional virtual monoenergetic imaging. Eur J Radiol 85:665–672. https://doi.org/10.1016/j.ejrad.2015.12.022 CrossRefPubMed Frellesen C, Kaup M, Wichmann JL, Husers K, Scholtz JE, Albrecht MH, Metzger SC, Bauer RW, Kerl JM, Lehnert T, Vogl TJ, Bodelle B (2016) Noise-optimized advanced image-based virtual monoenergetic imaging for improved visualization of lung cancer: comparison with traditional virtual monoenergetic imaging. Eur J Radiol 85:665–672. https://​doi.​org/​10.​1016/​j.​ejrad.​2015.​12.​022 CrossRefPubMed
19.
Zurück zum Zitat Wichmann JL, Gillott MR, De Cecco CN, Mangold S, Varga-Szemes A, Yamada R, Otani K, Canstein C, Fuller SR, Vogl TJ, Todoran TM, Schoepf UJ (2016) Dual-energy computed tomography angiography of the lower extremity runoff: impact of noise-optimized virtual monochromatic imaging on image quality and diagnostic accuracy. Invest Radiol 51:139–146. https://doi.org/10.1097/rli.0000000000000216 CrossRef Wichmann JL, Gillott MR, De Cecco CN, Mangold S, Varga-Szemes A, Yamada R, Otani K, Canstein C, Fuller SR, Vogl TJ, Todoran TM, Schoepf UJ (2016) Dual-energy computed tomography angiography of the lower extremity runoff: impact of noise-optimized virtual monochromatic imaging on image quality and diagnostic accuracy. Invest Radiol 51:139–146. https://​doi.​org/​10.​1097/​rli.​0000000000000216​ CrossRef
20.
Zurück zum Zitat Martin SS, Pfeifer S, Wichmann JL, Albrecht MH, Leithner D, Lenga L, Scholtz JE, Vogl TJ, Bodelle B (2017) Noise-optimized virtual monoenergetic dual-energy computed tomography: optimization of kiloelectron volt settings in patients with gastrointestinal stromal tumors. Abdom Radiol (NY) 42:718–726. https://doi.org/10.1007/s00261-016-1011-5 CrossRef Martin SS, Pfeifer S, Wichmann JL, Albrecht MH, Leithner D, Lenga L, Scholtz JE, Vogl TJ, Bodelle B (2017) Noise-optimized virtual monoenergetic dual-energy computed tomography: optimization of kiloelectron volt settings in patients with gastrointestinal stromal tumors. Abdom Radiol (NY) 42:718–726. https://​doi.​org/​10.​1007/​s00261-016-1011-5 CrossRef
21.
Zurück zum Zitat Martin SS, Albrecht MH, Wichmann JL, Husers K, Scholtz JE, Booz C, Bodelle B, Bauer RW, Metzger SC, Vogl TJ, Lehnert T (2017) Value of a noise-optimized virtual monoenergetic reconstruction technique in dual-energy CT for planning of transcatheter aortic valve replacement. Eur Radiol 27:705–714. https://doi.org/10.1007/s00330-016-4422-3 CrossRef Martin SS, Albrecht MH, Wichmann JL, Husers K, Scholtz JE, Booz C, Bodelle B, Bauer RW, Metzger SC, Vogl TJ, Lehnert T (2017) Value of a noise-optimized virtual monoenergetic reconstruction technique in dual-energy CT for planning of transcatheter aortic valve replacement. Eur Radiol 27:705–714. https://​doi.​org/​10.​1007/​s00330-016-4422-3 CrossRef
24.
Zurück zum Zitat Leithner D, Mahmoudi S, Wichmann JL, Martin SS, Lenga L, Albrecht MH, Booz C, Arendt CT, Beeres M, D’Angelo T, Bodelle B, Vogl TJ, Scholtz JE (2018) Evaluation of virtual monoenergetic imaging algorithms for dual-energy carotid and intracerebral CT angiography: effects on image quality, artefacts and diagnostic performance for the detection of stenosis. Eur J Radiol 99:111–117. https://doi.org/10.1016/j.ejrad.2017.12.024 CrossRefPubMed Leithner D, Mahmoudi S, Wichmann JL, Martin SS, Lenga L, Albrecht MH, Booz C, Arendt CT, Beeres M, D’Angelo T, Bodelle B, Vogl TJ, Scholtz JE (2018) Evaluation of virtual monoenergetic imaging algorithms for dual-energy carotid and intracerebral CT angiography: effects on image quality, artefacts and diagnostic performance for the detection of stenosis. Eur J Radiol 99:111–117. https://​doi.​org/​10.​1016/​j.​ejrad.​2017.​12.​024 CrossRefPubMed
25.
Zurück zum Zitat De Cecco CN, Caruso D, Schoepf UJ, De Santis D, Muscogiuri G, Albrecht MH, Meinel FG, Wichmann JL, Burchett PF, Varga-Szemes A, Sheafor DH, Hardie AD (2018) A noise-optimized virtual monoenergetic reconstruction algorithm improves the diagnostic accuracy of late hepatic arterial phase dual-energy CT for the detection of hypervascular liver lesions. Eur Radiol 28:3393–3404. https://doi.org/10.1007/s00330-018-5313-6 CrossRef De Cecco CN, Caruso D, Schoepf UJ, De Santis D, Muscogiuri G, Albrecht MH, Meinel FG, Wichmann JL, Burchett PF, Varga-Szemes A, Sheafor DH, Hardie AD (2018) A noise-optimized virtual monoenergetic reconstruction algorithm improves the diagnostic accuracy of late hepatic arterial phase dual-energy CT for the detection of hypervascular liver lesions. Eur Radiol 28:3393–3404. https://​doi.​org/​10.​1007/​s00330-018-5313-6 CrossRef
26.
Zurück zum Zitat Albrecht MH, Trommer J, Wichmann JL, Scholtz JE, Martin SS, Lehnert T, Vogl TJ, Bodelle B (2016) Comprehensive comparison of virtual monoenergetic and linearly blended reconstruction techniques in third-generation dual-source dual-energy computed tomography angiography of the thorax and abdomen. Invest Radiol 51:582–590. https://doi.org/10.1097/rli.0000000000000272 CrossRef Albrecht MH, Trommer J, Wichmann JL, Scholtz JE, Martin SS, Lehnert T, Vogl TJ, Bodelle B (2016) Comprehensive comparison of virtual monoenergetic and linearly blended reconstruction techniques in third-generation dual-source dual-energy computed tomography angiography of the thorax and abdomen. Invest Radiol 51:582–590. https://​doi.​org/​10.​1097/​rli.​0000000000000272​ CrossRef
30.
Zurück zum Zitat Grant KL, Flohr TG, Krauss B, Sedlmair M, Thomas C, Schmidt B (2014) Assessment of an advanced image-based technique to calculate virtual monoenergetic computed tomographic images from a dual-energy examination to improve contrast-to-noise ratio in examinations using iodinated contrast media. Invest Radiol 49:586–592. https://doi.org/10.1097/rli.0000000000000060 CrossRef Grant KL, Flohr TG, Krauss B, Sedlmair M, Thomas C, Schmidt B (2014) Assessment of an advanced image-based technique to calculate virtual monoenergetic computed tomographic images from a dual-energy examination to improve contrast-to-noise ratio in examinations using iodinated contrast media. Invest Radiol 49:586–592. https://​doi.​org/​10.​1097/​rli.​0000000000000060​ CrossRef
Metadaten
Titel
Noise-optimised virtual monoenergetic imaging of dual-energy CT: effect on metal artefact reduction in patients with lumbar internal fixation
verfasst von
Yanwei Zeng
Kai Deng
Haitao Yang
Yi Tan
Jun Liu
Daoying Geng
Jun Zhang
Publikationsdatum
30.04.2019
Verlag
Springer Berlin Heidelberg
Erschienen in
European Spine Journal / Ausgabe 8/2019
Print ISSN: 0940-6719
Elektronische ISSN: 1432-0932
DOI
https://doi.org/10.1007/s00586-019-05984-5

Weitere Artikel der Ausgabe 8/2019

European Spine Journal 8/2019 Zur Ausgabe

Arthropedia

Grundlagenwissen der Arthroskopie und Gelenkchirurgie. Erweitert durch Fallbeispiele, Videos und Abbildungen. 
» Jetzt entdecken

Update Orthopädie und Unfallchirurgie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.