Skip to main content
Erschienen in: The International Journal of Cardiovascular Imaging 8/2012

Open Access 01.12.2012 | Original Paper

Non-invasive assessment of atherosclerotic coronary lesion length using multidetector computed tomography angiography: comparison to quantitative coronary angiography

verfasst von: J. E. van Velzen, M. A. de Graaf, A. Ciarka, F. R. de Graaf, M. J. Schalij, L. J. Kroft, A. de Roos, J. W. Jukema, J. H. C. Reiber, J. D. Schuijf, J. J. Bax, E. E. van der Wall

Erschienen in: The International Journal of Cardiovascular Imaging | Ausgabe 8/2012

Abstract

Multidetector computed tomography angiography (CTA) provides information on plaque extent and stenosis in the coronary wall. More accurate lesion assessment may be feasible with CTA as compared to invasive coronary angiography (ICA). Accordingly, lesion length assessment was compared between ICA and CTA in patients referred for CTA who underwent subsequent percutaneous coronary intervention (PCI). 89 patients clinically referred for CTA were subsequently referred for ICA and PCI. On CTA, lesion length was measured from the proximal to the distal shoulder of the plaque. Quantitative coronary angiography (QCA) was performed to analyze lesion length. Stent length was recorded for each lesion. In total, 119 lesions were retrospectively identified. Mean lesion length on CTA was 21.4 ± 8.4 mm and on QCA 12.6 ± 6.1 mm. Mean stent length deployed was 17.4 ± 5.3 mm. Lesion length on CTA was significantly longer than on QCA (difference 8.8 ± 6.7 mm, P < 0.001). Moreover, lesion length visualized on CTA was also significantly longer than mean stent length (CTA lesion length-stent length was 4.2 ± 8.7 mm, P < 0.001). Lesion length assessed by CTA is longer than that assessed by ICA. Possibly, CTA provides more accurate lesion length assessment than ICA and may facilitate improved guidance of percutaneous treatment of coronary lesions.

Introduction

Invasive coronary angiography (ICA) has been traditionally used for evaluation of the presence and severity of coronary artery disease (CAD). Accordingly, the technique has been extensively utilized to guide further treatment strategies, such as percutaneous coronary intervention (PCI) with stent placement. In particular, the choice for stent length and diameter is frequently decided on the basis of the 2-dimensional ICA images. However, although ICA has an excellent ability to visualize the lumen and severity of luminal narrowing, the presence of atherosclerotic plaque in the arterial wall cannot be accurately visualized [1]. The chosen stent length may not always match the true atherosclerotic plaque length and could potentially lead to insufficient stent coverage of the plaque and possible development of post-stent complications such as arterial dissection, in-stent restenosis and stent thrombosis [24].
Several studies comparing ICA to intravascular ultrasound (IVUS) have shown that ICA indeed underestimates plaque extent [1, 5, 6]. Multidetector computed tomography angiography (CTA) is increasingly used to non-invasively evaluate the presence of CAD [7, 8], and a growing number of patients referred for ICA will have previously undergone non-invasive evaluation by CTA. A particular strength of this modality is that it is able to not only visualize luminal narrowing but also the extent of atherosclerotic plaque in the arterial wall [9, 10]. Accordingly, in patients with previous CTA, who subsequently underwent ICA and PCI, lesion length on CTA was compared to length on ICA.

Methods

Patients

A total of 89 patients were retrospectively analyzed, who were clinically referred for CTA and had subsequent ICA and PCI with stent implantation. For this retrospective evaluation, consecutive patients were selected as part of an ongoing registry addressing the relative merits of CTA in relation to other imaging techniques [11]. All clinical data were retrieved from the departmental Cardiology Information System (EPD-Vision®, Leiden University Medical Center). In each patient, the presence of CAD risk factors such as diabetes, systemic hypertension, hypercholesterolemia, positive family history, smoking and obesity, were noted.

Multidetector computed tomography coronary angiography

Data acquisition

Contra-indications for CTA were (1) (supra) ventricular arrhythmias, (2) renal insufficiency (glomerular filtration rate < 30 ml/min), (3) known allergy to iodine contrast material, (4) severe claustrophobia, (5) pregnancy.
Patients received beta-blocking medication (50–100 mg metoprolol orally, or 5–10 mg intravenously) 1 h before CTA examination if the heart rate was above 65 beats per minute, unless contra-indicated. Forty-seven patients were scanned on a 64-detector row helical scanner (Aquilion 64, Toshiba Medical Systems, Otawara, Japan). Scan parameters were: 400 ms gantry rotation time, 100–135 kV tube voltage and a tube current of 250–350 mA, depending on body shape. Thirty-six patients were scanned on a 320-detector row volumetric scanner (Aquilion ONE, Toshiba Medical Systems, Otawara, Japan). The heart was imaged in a single heartbeat, using prospective triggering with exposure interval depending on the heart rate. Scan parameters were: 350 ms gantry rotation time, 100–135 kV tube voltage and a tube current of 400–580 mA, depending on body mass index. In total, 60–90 ml contrast material (Iomeron 400, Bracco, Milan, Italy) was administered with a rate of 5–6 ml/s followed by a saline flush. Subsequently, data sets were reconstructed in the best available phase and transferred to a remote workstation.

CTA lesion length assessment

Post-processing of the CTA scans was performed on a dedicated workstation (Vitrea FX 2.0.2, Vital images Minnetonka, MN, USA). Coronary anatomy was assessed in a standardized manner by dividing the coronary artery tree into 17 segments according to the modified American Heart Association classification. CTA lesion length was evaluated in consensus by 2 experienced readers who were blinded to quantitative coronary angiography (QCA) lesion length findings. Firstly, the location of lesions was identified on ICA. To match lesions identified on ICA with lesions on CTA, landmarks such as coronary ostia, side-branches and calcium deposits were used. A plaque on CTA was defined as a structure ≥1 mm2 in the coronary artery lumen [12]. Secondly, on CTA, lesion length was determined on curved multiplanar reconstructions (MPR’s) in two different angles for every lesion in which PCI was performed. Lesion length (mm) was measured on CTA from the proximal to distal shoulder of the plaque with a dedicated Vitrea software display tool (Vitrea FX 2.0.2, Minnetonka, MN, USA). A tandem lesion within 4 mm of the edge of lesion was considered as part of the lesion. The average of these two measurements was taken as the final CTA lesion length. An example of lesion length measurement on CTA is shown in Fig. 1. Radiation dose was quantified with a dose-length product conversion factor of 0.014 mSv/(mGy cm) [13]. For the 320-row CTA, patients with a low heart rate (<60 bpm) were scanned full dose at 70–80% of R-R interval and estimated mean radiation dose was 3.2 ± 1.1 mSv. Patients with a higher heart rate (60–65 bpm) were scanned full dose at 65–85% of R–R interval and estimated mean radiation dose was 7.1 ± 1.7 mSv. For the 64-row CTA, the estimated mean radiation dose was 18.1 ± 5.9 mSv, all performed with retrospective gating.

Quantitative coronary angiography

Quantitative coronary angiography analysis was performed by observer unaware of CTA findings with the use of QCA-CMS version 6.0 (Medis, Leiden, The Netherlands). Prior to measuring lesion length, images were calibrated with use of the contrast filled catheter. Subsequently, per lesion, the two best orthogonal projections were chosen on which measurements were performed to minimize foreshortening. Consequently, lesion length (mm) was measured from the proximal shoulder to the distal shoulder of the lesion. The longest length measured on QCA was used for further analysis. In addition, highest percent diameter stenosis as measured by QCA was reported for each lesion. The choice and size of stent used were left to the discretion of operator. Per lesion, stent diameter and length were reported. If more than one stent was planned, the total stent length of all combined stents deployed was used.

Statistical analysis

Continuous variables were expressed as mean and standard deviation, and categorical data were expressed in numbers and percentages. Paired variables were analyzed with Wilcoxon signed rank tests. Statistical analysis was performed using SPSS software (version 16.0, SPSS Inc., Chicago, IL, USA). A P value < 0.05 was considered statistically significant.

Results

Of the 89 patients, 4 were excluded in which the target lesion length was not quantifiable on CTA. These lesions were either a total chronic occlusion (n = 2) or in-stent restenosis (n = 2). Furthermore 2 patients were excluded due to impaired CTA image quality. Consequently, 83 patients (59 males (71%), mean age 62 ± 10 years) and 119 lesions were included in the analysis. Baseline patient characteristics are described in Table 1. The average time interval between CTA and PCI was 63 ± 110 days. As determined by QCA, the mean percent stenosis of the lesions was 71 ± 11%. Overall, lesions were most often located in the left anterior descending coronary artery (56 lesions, 47%) followed by the left circumflex coronary artery (35 lesions, 29%) and the right coronary artery (28 lesions, 24%). Concerning plaque composition, 27 lesions (23%) were non-calcified, 72 lesions (60%) were mixed and 20 lesions (17%) were calcified.
Table 1
Patient characteristics (n = 83)
 
n (%)
Age (mean ± SD)
62 ± 10
Gender (male/female)
59/24
Obesity (BMI ≥ 30 kg/m2)
12 (14%)
Diabetes
18 (22%)
Hypertension
44 (53%)
Hypercholesterolemia
28 (34%)
Family history
37 (45%)
Smoking
33 (40%)
Previous stent (%)
18 (22%)
Complications during PCI
 Edge dissection
6 (7%)
 Stent thrombosisa
1 (1%)
BMI body mass index, PCI percutaneous coronary intervention
aDefined as definite, probable and possible stent thrombosis within 1 month

Lesion length

The mean lesion length measured on CTA was 21.4 ± 8.4 mm, as compared to a mean lesion length on QCA of 12.5 ± 6.1 mm resulting in a mean difference (CTA lesion length − QCA lesion length) of 8.8 ± 6.7 mm. Only 2 lesions were longer on QCA than on CTA, however the difference between these 2 lesions was only minor (13.2 mm on CTA vs. 14.3 mm on QCA and 5.7 mm on CTA vs. 6.7 mm on QCA). Overall, mean CTA lesion length was significantly longer than mean QCA lesion length (P < 0.001), as demonstrated in Fig. 2. At Bland–Altman analysis, mean differences (±SD) of 8.8 ± 6.7 mm were observed between CTA and ICA, with 95% limits of agreement ranging from −4.3 to 22.0 (Fig. 3). The mean diameter of stents deployed was 3.1 ± 0.3 mm, ranging from 3.0 to 4.0 mm. The length of stents deployed ranged from 8.0 to 33.0 mm (mean 17.5 ± 5.3 mm). Accordingly, lesion length on CTA was also significantly longer than mean stent length (CTA lesion length − stent length was 4.2 ± 8.7 mm, P < 0.001). Furthermore, mean stent length exceeded lesion length on QCA; stent length − QCA lesion length was 4.8 ± 6.2 mm (P < 0.001).

Discussion

Comparison between ICA and non-invasive CTA demonstrated that lesion length measured by CTA was substantially longer than lesion length measured by ICA. In addition, lesion length on CTA was compared to the stent length selected for PCI. Interestingly, lesion length measured by CTA significantly exceeded the mean length over which the stent was deployed.
There are only very limited data regarding lesion length measurement with CTA. Soon et al. [14] compared atherosclerotic lesion length between ICA and CTA (16-slice) in 30 patients and 44 lesions and observed that lesion length was significantly longer on CTA than on ICA with a median difference of 9.8 mm (95% confidence interval of 7.3–13.3). Moreover, the finding that ICA significantly underestimates atherosclerotic lesion length has also been demonstrated by Yamagishi et al, who compared atherosclerotic lesion length on ICA to grayscale IVUS, the current gold standard for the evaluation of atherosclerosis [5]. The authors demonstrated that lesion length on ICA (mean lesion length of 12.4 ± 6.1 mm) was significantly shorter than lesion length measured by IVUS (mean lesion length of 16.3 ± 8.9 mm).
Although angiographically detected coronary atherosclerosis has been linked to outcome in several clinical trials [1518], it has been suggested that ICA considerably underestimates the overall extent of CAD [19]. Indeed, when compared to IVUS, the presence of angiographic disease did not reflect true atherosclerotic plaque burden [1]. Mintz et al. [1] compared the detection of atherosclerosis on ICA to IVUS and found that only 7% of segments described as normal on ICA were truly without any atherosclerotic plaque on IVUS. Conversely, non-invasive CTA has been shown to provide accurate evaluation of coronary plaque burden [9, 2022], with a good correlation for detecting and characterizing atherosclerotic plaque in comparison to histology [2325]. Moreover, Leber et al. [12] demonstrated a sensitivity and specificity of 16-slice CTA for the detection of coronary lesions as determined on IVUS of 85 and 92%, respectively. However, small plaques located in distal segments were more difficult to evaluate, particularly in CTA scans with reduced image quality [12].
The large difference between ICA and CTA lesion length assessment can be explained by the excellent ability of CTA to visualize plaque and vessel remodelling in the arterial wall, in contrast to ICA. Indeed, ICA only shows the contrast filled lumen and is unable to visualize the arterial wall (with the exception of large calcifications), and reference segments may not be optimally evaluated by ICA [26]. Indeed, with traditional invasive coronary angiography, lesions with outward (positive) remodeling are frequently underestimated or missed. Moreover, CTA is not hampered by limitations of angiographic projection such as foreshortening or difficulties in case of tortuous vessels. However, it is of importance to identify the presence of atherosclerosis even at sites without significant luminal narrowing, and some acute coronary syndromes may be triggered by sudden disruption of atherosclerotic plaques that caused neither significant luminal narrowing nor chest pain complaints before the event [27]. It has been suggested that the most rupture prone part of the plaque is not at the maximum point of luminal narrowing but actually located in the shoulders of the plaque [28]. Accordingly, it is important to assess the entire plaque length.
It has also been demonstrated that insufficient coverage of the target lesion increases the risk for in-stent restenosis and stent thrombosis. Fujii et al. retrospectively evaluated lesion characteristics using IVUS leading to stent thrombosis after PCI [2]. The authors observed that stent thrombosis occurred in stents with significantly more residual plaque upstream and downstream from the stent as compared to lesions without stent thrombosis. Okabe et al. [3] explored which IVUS related findings predicted the risk for the development of stent thrombosis. The authors observed that residual disease at the edge of the stent was associated with subsequent stent thrombosis. Of note, a higher residual plaque burden proximal from the stent has also been associated with increased rates of in-stent restenosis [4]. Accordingly, optimal assessment of the lesion length may improve success and outcome of interventional procedures [29].

Limitations

Several limitations need to be addressed. First, there was a time-interval between CTA and PCI during which atherosclerosis may have progressed. Second, only lesions subsequently treated by PCI were included in the study. Therefore, the current observations are only based on lesions with a high grade stenosis. Third, in the current study QCA was not part of the clinical routine of the laboratory and the difference between the CTA lesion length and the stent length chosen reflects the discrepancy between stent length driven by visual assessment. Furthermore, the attending interventional cardiologist did not incorporate lesion topography on CTA before performing PCI. However, future studies should be performed to evaluate the value and improved outcome of CTA lesion assessment prior to PCI.

Conclusion

Lesion length assessed by CTA is longer than lesion length assessed by ICA, which may facilitate improved guidance of percutaneous treatment of coronary lesions.

Acknowledgments

Dr. van Velzen is supported by the Dutch Heart Foundation (The Hague, The Netherlands), grant no. 2007B223. Dr. de Graaf is co-supported by the Dutch Technology Foundation STW (Utrecht, the Netherlands), applied science division of I and the Technology Program of the Ministry of Economic Affairs, grant no. 10084.

Conflict of interest

Dr. Bax has research grants from BMS medical imaging (New York, USA) and GE Healthcare (Chalfont St Giles, UK).

Open Access

This article is distributed under the terms of the Creative Commons Attribution License which permits any use, distribution, and reproduction in any medium, provided the original author(s) and the source are credited.
Open AccessThis is an open access article distributed under the terms of the Creative Commons Attribution Noncommercial License (https://​creativecommons.​org/​licenses/​by-nc/​2.​0), which permits any noncommercial use, distribution, and reproduction in any medium, provided the original author(s) and source are credited.

Unsere Produktempfehlungen

e.Med Interdisziplinär

Kombi-Abonnement

Für Ihren Erfolg in Klinik und Praxis - Die beste Hilfe in Ihrem Arbeitsalltag

Mit e.Med Interdisziplinär erhalten Sie Zugang zu allen CME-Fortbildungen und Fachzeitschriften auf SpringerMedizin.de.

e.Med Innere Medizin

Kombi-Abonnement

Mit e.Med Innere Medizin erhalten Sie Zugang zu CME-Fortbildungen des Fachgebietes Innere Medizin, den Premium-Inhalten der internistischen Fachzeitschriften, inklusive einer gedruckten internistischen Zeitschrift Ihrer Wahl.

Literatur
1.
Zurück zum Zitat Mintz GS, Painter JA, Pichard AD et al (1995) Atherosclerosis in angiographically “normal” coronary artery reference segments: an intravascular ultrasound study with clinical correlations. J Am Coll Cardiol 25(7):1479–1485PubMedCrossRef Mintz GS, Painter JA, Pichard AD et al (1995) Atherosclerosis in angiographically “normal” coronary artery reference segments: an intravascular ultrasound study with clinical correlations. J Am Coll Cardiol 25(7):1479–1485PubMedCrossRef
2.
Zurück zum Zitat Fujii K, Carlier SG, Mintz GS et al (2005) Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study. J Am Coll Cardiol 45(7):995–998PubMedCrossRef Fujii K, Carlier SG, Mintz GS et al (2005) Stent underexpansion and residual reference segment stenosis are related to stent thrombosis after sirolimus-eluting stent implantation: an intravascular ultrasound study. J Am Coll Cardiol 45(7):995–998PubMedCrossRef
3.
Zurück zum Zitat Okabe T, Mintz GS, Buch AN et al (2007) Intravascular ultrasound parameters associated with stent thrombosis after drug-eluting stent deployment. Am J Cardiol 100(4):615–620PubMedCrossRef Okabe T, Mintz GS, Buch AN et al (2007) Intravascular ultrasound parameters associated with stent thrombosis after drug-eluting stent deployment. Am J Cardiol 100(4):615–620PubMedCrossRef
4.
Zurück zum Zitat Liu XB, Qian JY, Zhang F et al (2009) Intravascular ultrasound assessment of sirolimus-eluting stent restenosis or thrombosis after stent implantation. Zhonghua Xin Xue Guan Bing Za Zhi 37(5):397–401PubMed Liu XB, Qian JY, Zhang F et al (2009) Intravascular ultrasound assessment of sirolimus-eluting stent restenosis or thrombosis after stent implantation. Zhonghua Xin Xue Guan Bing Za Zhi 37(5):397–401PubMed
5.
Zurück zum Zitat Yamagishi M, Hosokawa H, Saito S et al (2002) Coronary disease morphology and distribution determined by quantitative angiography and intravascular ultrasound—re-evaluation in a cooperative multicenter intravascular ultrasound study (COMIUS). Circ J 66(8):735–740PubMedCrossRef Yamagishi M, Hosokawa H, Saito S et al (2002) Coronary disease morphology and distribution determined by quantitative angiography and intravascular ultrasound—re-evaluation in a cooperative multicenter intravascular ultrasound study (COMIUS). Circ J 66(8):735–740PubMedCrossRef
6.
Zurück zum Zitat Porter TR, Sears T, Xie F et al (1993) Intravascular ultrasound study of angiographically mildly diseased coronary arteries. J Am Coll Cardiol 22(7):1858–1865PubMedCrossRef Porter TR, Sears T, Xie F et al (1993) Intravascular ultrasound study of angiographically mildly diseased coronary arteries. J Am Coll Cardiol 22(7):1858–1865PubMedCrossRef
7.
Zurück zum Zitat Meijboom WB, van Mieghem CA, Mollet NR et al (2007) 64-slice computed tomography coronary angiography in patients with high, intermediate, or low pretest probability of significant coronary artery disease. J Am Coll Cardiol 50(15):1469–1475PubMedCrossRef Meijboom WB, van Mieghem CA, Mollet NR et al (2007) 64-slice computed tomography coronary angiography in patients with high, intermediate, or low pretest probability of significant coronary artery disease. J Am Coll Cardiol 50(15):1469–1475PubMedCrossRef
8.
Zurück zum Zitat Meijboom WB, Meijs MF, Schuijf JD et al (2008) Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study. J Am Coll Cardiol 52(25):2135–2144PubMedCrossRef Meijboom WB, Meijs MF, Schuijf JD et al (2008) Diagnostic accuracy of 64-slice computed tomography coronary angiography: a prospective, multicenter, multivendor study. J Am Coll Cardiol 52(25):2135–2144PubMedCrossRef
9.
Zurück zum Zitat Achenbach S, Moselewski F, Ropers D et al (2004) Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography: a segment-based comparison with intravascular ultrasound. Circulation 109(1):14–17PubMedCrossRef Achenbach S, Moselewski F, Ropers D et al (2004) Detection of calcified and noncalcified coronary atherosclerotic plaque by contrast-enhanced, submillimeter multidetector spiral computed tomography: a segment-based comparison with intravascular ultrasound. Circulation 109(1):14–17PubMedCrossRef
10.
Zurück zum Zitat Kass M, Glover CA, Labinaz M et al (2010) Lesion characteristics and coronary stent selection with computed tomographic coronary angiography: a pilot investigation comparing CTA, QCA and IVUS. J Invasive Cardiol 22(7):328–334PubMed Kass M, Glover CA, Labinaz M et al (2010) Lesion characteristics and coronary stent selection with computed tomographic coronary angiography: a pilot investigation comparing CTA, QCA and IVUS. J Invasive Cardiol 22(7):328–334PubMed
11.
Zurück zum Zitat Van Velzen JE, Schuijf JD, De Graaf FR et al (2009) Plaque type and composition as evaluated non-invasively by MSCT angiography and invasively by VH IVUS in relation to the degree of stenosis. Heart 95(24):1990–1996PubMedCrossRef Van Velzen JE, Schuijf JD, De Graaf FR et al (2009) Plaque type and composition as evaluated non-invasively by MSCT angiography and invasively by VH IVUS in relation to the degree of stenosis. Heart 95(24):1990–1996PubMedCrossRef
12.
Zurück zum Zitat Leber AW, Knez A, Becker A et al (2004) Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound. J Am Coll Cardiol 43(7):1241–1247PubMedCrossRef Leber AW, Knez A, Becker A et al (2004) Accuracy of multidetector spiral computed tomography in identifying and differentiating the composition of coronary atherosclerotic plaques: a comparative study with intracoronary ultrasound. J Am Coll Cardiol 43(7):1241–1247PubMedCrossRef
13.
Zurück zum Zitat Hausleiter J, Meyer T, Hermann F et al (2009) Estimated radiation dose associated with cardiac CT angiography. JAMA 301(5):500–507PubMedCrossRef Hausleiter J, Meyer T, Hermann F et al (2009) Estimated radiation dose associated with cardiac CT angiography. JAMA 301(5):500–507PubMedCrossRef
14.
Zurück zum Zitat Soon KH, Farouque HM, Chaitowitz I et al (2007) Discrepancy between computed tomography coronary angiography and selective coronary angiography in the pre-stenting assessment of coronary lesion length. Australas Radiol 51(5):440–445PubMedCrossRef Soon KH, Farouque HM, Chaitowitz I et al (2007) Discrepancy between computed tomography coronary angiography and selective coronary angiography in the pre-stenting assessment of coronary lesion length. Australas Radiol 51(5):440–445PubMedCrossRef
15.
Zurück zum Zitat Bigi R, Cortigiani L, Colombo P et al (2003) Prognostic and clinical correlates of angiographically diffuse non-obstructive coronary lesions. Heart 89(9):1009–1013PubMedCrossRef Bigi R, Cortigiani L, Colombo P et al (2003) Prognostic and clinical correlates of angiographically diffuse non-obstructive coronary lesions. Heart 89(9):1009–1013PubMedCrossRef
16.
Zurück zum Zitat Califf RM, Phillips HR III, Hindman MC et al (1985) Prognostic value of a coronary artery jeopardy score. J Am Coll Cardiol 5(5):1055–1063PubMedCrossRef Califf RM, Phillips HR III, Hindman MC et al (1985) Prognostic value of a coronary artery jeopardy score. J Am Coll Cardiol 5(5):1055–1063PubMedCrossRef
17.
Zurück zum Zitat Cashin-Hemphill L, Mack WJ, Pogoda JM et al (1990) Beneficial effects of colestipol-niacin on coronary atherosclerosis. A 4-year follow-up. JAMA 264(23):3013–3017PubMedCrossRef Cashin-Hemphill L, Mack WJ, Pogoda JM et al (1990) Beneficial effects of colestipol-niacin on coronary atherosclerosis. A 4-year follow-up. JAMA 264(23):3013–3017PubMedCrossRef
18.
Zurück zum Zitat Schuler G, Hambrecht R, Schlierf G et al (1992) Regular physical exercise and low-fat diet. Effects on progression of coronary artery disease. Circulation 86(1):1–11PubMedCrossRef Schuler G, Hambrecht R, Schlierf G et al (1992) Regular physical exercise and low-fat diet. Effects on progression of coronary artery disease. Circulation 86(1):1–11PubMedCrossRef
19.
Zurück zum Zitat Butler J, Shapiro M, Reiber J et al (2007) Extent and distribution of coronary artery disease: a comparative study of invasive versus noninvasive angiography with computed angiography. Am Heart J 153(3):378–384PubMedCrossRef Butler J, Shapiro M, Reiber J et al (2007) Extent and distribution of coronary artery disease: a comparative study of invasive versus noninvasive angiography with computed angiography. Am Heart J 153(3):378–384PubMedCrossRef
20.
Zurück zum Zitat Becker CR, Nikolaou K, Muders M et al (2003) Ex vivo coronary atherosclerotic plaque characterization with multi-detector-row CT. Eur Radiol 13(9):2094–2098PubMedCrossRef Becker CR, Nikolaou K, Muders M et al (2003) Ex vivo coronary atherosclerotic plaque characterization with multi-detector-row CT. Eur Radiol 13(9):2094–2098PubMedCrossRef
21.
Zurück zum Zitat Petranovic M, Soni A, Bezzera H et al (2009) Assessment of nonstenotic coronary lesions by 64-slice multidetector computed tomography in comparison to intravascular ultrasound: evaluation of nonculprit coronary lesions. J Cardiovasc Comput Tomogr 3(1):24–31PubMedCrossRef Petranovic M, Soni A, Bezzera H et al (2009) Assessment of nonstenotic coronary lesions by 64-slice multidetector computed tomography in comparison to intravascular ultrasound: evaluation of nonculprit coronary lesions. J Cardiovasc Comput Tomogr 3(1):24–31PubMedCrossRef
22.
Zurück zum Zitat Schepis T, Marwan M, Pflederer T et al (2009) Quantification of noncalcified coronary atherosclerotic plaques with dual source computed tomography: comparison to intravascular ultrasound. Heart 96(8):610–615 Schepis T, Marwan M, Pflederer T et al (2009) Quantification of noncalcified coronary atherosclerotic plaques with dual source computed tomography: comparison to intravascular ultrasound. Heart 96(8):610–615
23.
Zurück zum Zitat Nikolaou K, Becker CR, Muders M et al (2004) Multidetector-row computed tomography and magnetic resonance imaging of atherosclerotic lesions in human ex vivo coronary arteries. Atherosclerosis 174(2):243–252PubMedCrossRef Nikolaou K, Becker CR, Muders M et al (2004) Multidetector-row computed tomography and magnetic resonance imaging of atherosclerotic lesions in human ex vivo coronary arteries. Atherosclerosis 174(2):243–252PubMedCrossRef
24.
Zurück zum Zitat Schroeder S, Kuettner A, Wojak T et al (2004) Non-invasive evaluation of atherosclerosis with contrast enhanced 16 slice spiral computed tomography: results of ex vivo investigations. Heart 90(12):1471–1475PubMedCrossRef Schroeder S, Kuettner A, Wojak T et al (2004) Non-invasive evaluation of atherosclerosis with contrast enhanced 16 slice spiral computed tomography: results of ex vivo investigations. Heart 90(12):1471–1475PubMedCrossRef
25.
Zurück zum Zitat Schroeder S, Kuettner A, Leitritz M et al (2004) Reliability of differentiating human coronary plaque morphology using contrast-enhanced multislice spiral computed tomography: a comparison with histology. J Comput Assist Tomogr 28(4):449–454PubMedCrossRef Schroeder S, Kuettner A, Leitritz M et al (2004) Reliability of differentiating human coronary plaque morphology using contrast-enhanced multislice spiral computed tomography: a comparison with histology. J Comput Assist Tomogr 28(4):449–454PubMedCrossRef
26.
Zurück zum Zitat Mintz GS, Pichard AD, Kent KM et al (1998) Interrelation of coronary angiographic reference lumen size and intravascular ultrasound target lesion calcium. Am J Cardiol 81(4):387–391PubMedCrossRef Mintz GS, Pichard AD, Kent KM et al (1998) Interrelation of coronary angiographic reference lumen size and intravascular ultrasound target lesion calcium. Am J Cardiol 81(4):387–391PubMedCrossRef
27.
Zurück zum Zitat Virmani R, Burke AP, Kolodgie FD et al (2003) Pathology of the thin-cap fibroatheroma: a type of vulnerable plaque. J Interv Cardiol 16(3):267–272PubMedCrossRef Virmani R, Burke AP, Kolodgie FD et al (2003) Pathology of the thin-cap fibroatheroma: a type of vulnerable plaque. J Interv Cardiol 16(3):267–272PubMedCrossRef
28.
Zurück zum Zitat Virmani R, Kolodgie FD, Burke AP et al (2000) Lessons from sudden coronary death: a comprehensive morphological classification scheme for atherosclerotic lesions. Arterioscler Thromb Vasc Biol 20(5):1262–1275PubMedCrossRef Virmani R, Kolodgie FD, Burke AP et al (2000) Lessons from sudden coronary death: a comprehensive morphological classification scheme for atherosclerotic lesions. Arterioscler Thromb Vasc Biol 20(5):1262–1275PubMedCrossRef
29.
Zurück zum Zitat Hecht HS (2008) Applications of multislice coronary computed tomographic angiography to percutaneous coronary intervention: how did we ever do without it? Catheter Cardiovasc Interv 71(4):490–503PubMedCrossRef Hecht HS (2008) Applications of multislice coronary computed tomographic angiography to percutaneous coronary intervention: how did we ever do without it? Catheter Cardiovasc Interv 71(4):490–503PubMedCrossRef
Metadaten
Titel
Non-invasive assessment of atherosclerotic coronary lesion length using multidetector computed tomography angiography: comparison to quantitative coronary angiography
verfasst von
J. E. van Velzen
M. A. de Graaf
A. Ciarka
F. R. de Graaf
M. J. Schalij
L. J. Kroft
A. de Roos
J. W. Jukema
J. H. C. Reiber
J. D. Schuijf
J. J. Bax
E. E. van der Wall
Publikationsdatum
01.12.2012
Verlag
Springer Netherlands
Erschienen in
The International Journal of Cardiovascular Imaging / Ausgabe 8/2012
Print ISSN: 1569-5794
Elektronische ISSN: 1875-8312
DOI
https://doi.org/10.1007/s10554-012-0015-7

Weitere Artikel der Ausgabe 8/2012

The International Journal of Cardiovascular Imaging 8/2012 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.