Skip to main content
Erschienen in: Cardiovascular Intervention and Therapeutics 4/2017

27.12.2016 | Case Report

Non-occlusive mesenteric ischemia accompanied by aortic regurgitation after transcatheter aortic valve implantation

verfasst von: Kentaro Meguro, Junro Ishizaki, Tomoyoshi Yanagisawa, Toshimi Koitabashi, Tadashi Kitamura, Junya Ako

Erschienen in: Cardiovascular Intervention and Therapeutics | Ausgabe 4/2017

Einloggen, um Zugang zu erhalten

Abstract

An 81-year-old male with severe symptomatic aortic stenosis with ventricular tachycardia was referred for treatment. Balloon aortic valvuloplasty was performed under cardiopulmonary resuscitation. Though transcatheter aortic valve implantation (TAVI) was considered high risk for annulus rupture and aortic regurgitation due to annular calcification, TAVI was performed because of extremely high surgical risk. Moderate-to-severe aortic regurgitation (AR) remained and progression of acidosis could not be managed with continuous hemodiafiltration. His autopsy revealed the development of non-occlusive mesenteric ischemia (NOMI) as the cause of progressive acidosis. AR and hemodynamic instability might contribute to the development and progression of NOMI after TAVI.
Literatur
1.
Zurück zum Zitat Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med. 2010;363(17):1597–607.CrossRefPubMed Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG, et al. Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med. 2010;363(17):1597–607.CrossRefPubMed
2.
Zurück zum Zitat Smith CR, Leon MB, Mack MJ, Miller DC, Moses JW, Svensson LG, et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med. 2011;364(23):2187–98.CrossRefPubMed Smith CR, Leon MB, Mack MJ, Miller DC, Moses JW, Svensson LG, et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med. 2011;364(23):2187–98.CrossRefPubMed
3.
Zurück zum Zitat Ussia GP, Mule M, Barbanti M, Cammalleri V, Scarabelli M, Imme S, et al. Quality of life assessment after percutaneous aortic valve implantation. Eur Heart J. 2009;30(14):1790–6.CrossRefPubMed Ussia GP, Mule M, Barbanti M, Cammalleri V, Scarabelli M, Imme S, et al. Quality of life assessment after percutaneous aortic valve implantation. Eur Heart J. 2009;30(14):1790–6.CrossRefPubMed
4.
Zurück zum Zitat Tamburino C, Capodanno D, Ramondo A, Petronio AS, Ettori F, Santoro G, et al. Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis. Circulation. 2011;123(3):299–308.CrossRefPubMed Tamburino C, Capodanno D, Ramondo A, Petronio AS, Ettori F, Santoro G, et al. Incidence and predictors of early and late mortality after transcatheter aortic valve implantation in 663 patients with severe aortic stenosis. Circulation. 2011;123(3):299–308.CrossRefPubMed
5.
Zurück zum Zitat Webb JG, Pasupati S, Humphries K, Thompson C, Altwegg L, Moss R, et al. Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis. Circulation. 2007;116(7):755–63.CrossRefPubMed Webb JG, Pasupati S, Humphries K, Thompson C, Altwegg L, Moss R, et al. Percutaneous transarterial aortic valve replacement in selected high-risk patients with aortic stenosis. Circulation. 2007;116(7):755–63.CrossRefPubMed
6.
Zurück zum Zitat Athappan G, Patvardhan E, Tuzcu EM, Svensson LG, Lemos PA, Fraccaro C, et al. Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol. 2013;61(15):1585–95.CrossRefPubMed Athappan G, Patvardhan E, Tuzcu EM, Svensson LG, Lemos PA, Fraccaro C, et al. Incidence, predictors, and outcomes of aortic regurgitation after transcatheter aortic valve replacement: meta-analysis and systematic review of literature. J Am Coll Cardiol. 2013;61(15):1585–95.CrossRefPubMed
7.
Zurück zum Zitat Barbanti M, Yang TH, Rodes Cabau J, Tamburino C, Wood DA, Jilaihawi H, et al. Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement. Circulation. 2013;128(3):244–53.CrossRefPubMed Barbanti M, Yang TH, Rodes Cabau J, Tamburino C, Wood DA, Jilaihawi H, et al. Anatomical and procedural features associated with aortic root rupture during balloon-expandable transcatheter aortic valve replacement. Circulation. 2013;128(3):244–53.CrossRefPubMed
8.
Zurück zum Zitat Meguro K, Lellouche N, Yamamoto M, Fougeres E, Monin JL, Lim P, et al. Prognostic value of QRS duration after transcatheter aortic valve implantation for aortic stenosis using the CoreValve. Am J Cardiol. 2013;111(12):1778–83.CrossRefPubMed Meguro K, Lellouche N, Yamamoto M, Fougeres E, Monin JL, Lim P, et al. Prognostic value of QRS duration after transcatheter aortic valve implantation for aortic stenosis using the CoreValve. Am J Cardiol. 2013;111(12):1778–83.CrossRefPubMed
9.
Zurück zum Zitat Nagasawa A, Shirai S, Hanyu M, Arai Y, Kamioka N, Hayashi M. Descending aortic dissection injured by tip of the sheath during transcatheter aortic valve implantation. Cardiovasc Interv Ther. 2016;31(2):122–7.CrossRefPubMed Nagasawa A, Shirai S, Hanyu M, Arai Y, Kamioka N, Hayashi M. Descending aortic dissection injured by tip of the sheath during transcatheter aortic valve implantation. Cardiovasc Interv Ther. 2016;31(2):122–7.CrossRefPubMed
10.
Zurück zum Zitat Boley SJ, Brandt LJ, Sammartano RJ. History of mesenteric ischemia. The evolution of a diagnosis and management. Surg Clin N Am. 1997;77(2):275–88.CrossRefPubMed Boley SJ, Brandt LJ, Sammartano RJ. History of mesenteric ischemia. The evolution of a diagnosis and management. Surg Clin N Am. 1997;77(2):275–88.CrossRefPubMed
11.
Zurück zum Zitat Mitsuyoshi A, Obama K, Shinkura N, Ito T, Zaima M. Survival in nonocclusive mesenteric ischemia: early diagnosis by multidetector row computed tomography and early treatment with continuous intravenous high-dose prostaglandin E(1). Ann Surg. 2007;246(2):229–35.CrossRefPubMedPubMedCentral Mitsuyoshi A, Obama K, Shinkura N, Ito T, Zaima M. Survival in nonocclusive mesenteric ischemia: early diagnosis by multidetector row computed tomography and early treatment with continuous intravenous high-dose prostaglandin E(1). Ann Surg. 2007;246(2):229–35.CrossRefPubMedPubMedCentral
12.
Zurück zum Zitat Schoots IG, Koffeman GI, Legemate DA, Levi M, van Gulik TM. Systematic review of survival after acute mesenteric ischaemia according to disease aetiology. Br J Surg. 2004;91(1):17–27.CrossRefPubMed Schoots IG, Koffeman GI, Legemate DA, Levi M, van Gulik TM. Systematic review of survival after acute mesenteric ischaemia according to disease aetiology. Br J Surg. 2004;91(1):17–27.CrossRefPubMed
13.
Zurück zum Zitat Groesdonk HV, Klingele M, Schlempp S, Bomberg H, Schmied W, Minko P, et al. Risk factors for nonocclusive mesenteric ischemia after elective cardiac surgery. J Thorac Cardiovasc Surg. 2013;145(6):1603–10.CrossRefPubMed Groesdonk HV, Klingele M, Schlempp S, Bomberg H, Schmied W, Minko P, et al. Risk factors for nonocclusive mesenteric ischemia after elective cardiac surgery. J Thorac Cardiovasc Surg. 2013;145(6):1603–10.CrossRefPubMed
14.
Zurück zum Zitat Quiroga B, Verde E, Abad S, Vega A, Goicoechea M, Reque J, et al. Detection of patients at high risk for non-occlusive mesenteric ischemia in hemodialysis. J Surg Res. 2013;180(1):51–5.CrossRefPubMed Quiroga B, Verde E, Abad S, Vega A, Goicoechea M, Reque J, et al. Detection of patients at high risk for non-occlusive mesenteric ischemia in hemodialysis. J Surg Res. 2013;180(1):51–5.CrossRefPubMed
15.
Zurück zum Zitat Sastry P, Hardman G, Page A, Parker R, Goddard M, Large S, et al. Mesenteric ischaemia following cardiac surgery: the influence of intraoperative perfusion parameters. Interact Cardiovasc Thorac Surg. 1992;19(3):419–24.CrossRef Sastry P, Hardman G, Page A, Parker R, Goddard M, Large S, et al. Mesenteric ischaemia following cardiac surgery: the influence of intraoperative perfusion parameters. Interact Cardiovasc Thorac Surg. 1992;19(3):419–24.CrossRef
16.
Zurück zum Zitat Klotz S, Vestring T, Rotker J, Schmidt C, Scheld HH, Schmid C. Diagnosis and treatment of nonocclusive mesenteric ischemia after open heart surgery. Ann Thorac Surg. 2001;72(5):1583–6.CrossRefPubMed Klotz S, Vestring T, Rotker J, Schmidt C, Scheld HH, Schmid C. Diagnosis and treatment of nonocclusive mesenteric ischemia after open heart surgery. Ann Thorac Surg. 2001;72(5):1583–6.CrossRefPubMed
17.
Zurück zum Zitat Trompeter M, Brazda T, Remy CT, Vestring T, Reimer P. Non-occlusive mesenteric ischemia: etiology, diagnosis, and interventional therapy. Eur Radiol. 2002;12(5):1179–87.CrossRefPubMed Trompeter M, Brazda T, Remy CT, Vestring T, Reimer P. Non-occlusive mesenteric ischemia: etiology, diagnosis, and interventional therapy. Eur Radiol. 2002;12(5):1179–87.CrossRefPubMed
18.
Zurück zum Zitat Sinning JM, Hammerstingl C, Vasa-Nicotera M, Adenauer V, Lema Cachiguango SJ, Scheer AC, et al. Aortic regurgitation index defines severity of peri-prosthetic regurgitation and predicts outcome in patients after transcatheter aortic valve implantation. J Am Coll Cardiol. 2012;59(13):1134–41.CrossRefPubMed Sinning JM, Hammerstingl C, Vasa-Nicotera M, Adenauer V, Lema Cachiguango SJ, Scheer AC, et al. Aortic regurgitation index defines severity of peri-prosthetic regurgitation and predicts outcome in patients after transcatheter aortic valve implantation. J Am Coll Cardiol. 2012;59(13):1134–41.CrossRefPubMed
19.
Zurück zum Zitat Watanabe Y, Lefevre T, Arai T, Hayashida K, Bouvier E, Hovasse T, et al. Can we predict postprocedural paravalvular leak after Edwards SAPIEN transcatheter aortic valve implantation? Catheter Cardiovasc Interv. 2015;86(1):144–51.CrossRefPubMed Watanabe Y, Lefevre T, Arai T, Hayashida K, Bouvier E, Hovasse T, et al. Can we predict postprocedural paravalvular leak after Edwards SAPIEN transcatheter aortic valve implantation? Catheter Cardiovasc Interv. 2015;86(1):144–51.CrossRefPubMed
20.
Zurück zum Zitat Cockburn J, Charlton T, Gomes A, Trivedi U, Hildick-Smith D. Transcatheter aortic valve implantation and simultaneous closure of associated paravalvular leak. Cardiovasc Interv Ther. 2015;31(1):56–60.CrossRefPubMed Cockburn J, Charlton T, Gomes A, Trivedi U, Hildick-Smith D. Transcatheter aortic valve implantation and simultaneous closure of associated paravalvular leak. Cardiovasc Interv Ther. 2015;31(1):56–60.CrossRefPubMed
21.
Zurück zum Zitat Webb J, Gerosa G, Lefevre T, Leipsic J, Spence M, Thomas M, et al. Multicenter evaluation of a next-generation balloon-expandable transcatheter aortic valve. J Am Coll Cardiol. 2014;64(21):2235–43.CrossRefPubMed Webb J, Gerosa G, Lefevre T, Leipsic J, Spence M, Thomas M, et al. Multicenter evaluation of a next-generation balloon-expandable transcatheter aortic valve. J Am Coll Cardiol. 2014;64(21):2235–43.CrossRefPubMed
Metadaten
Titel
Non-occlusive mesenteric ischemia accompanied by aortic regurgitation after transcatheter aortic valve implantation
verfasst von
Kentaro Meguro
Junro Ishizaki
Tomoyoshi Yanagisawa
Toshimi Koitabashi
Tadashi Kitamura
Junya Ako
Publikationsdatum
27.12.2016
Verlag
Springer Japan
Erschienen in
Cardiovascular Intervention and Therapeutics / Ausgabe 4/2017
Print ISSN: 1868-4300
Elektronische ISSN: 1868-4297
DOI
https://doi.org/10.1007/s12928-016-0450-9

Weitere Artikel der Ausgabe 4/2017

Cardiovascular Intervention and Therapeutics 4/2017 Zur Ausgabe

Update Kardiologie

Bestellen Sie unseren Fach-Newsletter und bleiben Sie gut informiert.